INSTALLATION
Vectaire gas convection ovens are
manufactured for use with the type of gas and
electric supply indicated on the nameplate
behind the fire box panel.
The Vectaire oven is produced with the best
possible material and workmanship.
Proper installation is essential for safe and
efficient trouble-free operation.
NOTE: The installation instructions
contained herein are for the use of qualified
installation and service personnel only.
Installation or service by other than qualified
personnel may result in damage to the oven
and/or injury to the operator.
Qualified installation personnel are individuals,
a firm, corporation or company which either in
person, or through a representative are
engaged in, and are responsible for:
1. The installation or replacement of gas
piping or the connection, installation, repair
or servicing of equipment, who is
experienced in such work, familiar with all
precautions required, and has complied
with all requirements of state or local
authorities having jurisdiction. Reference:
National Fuel Gas Code Z223.1-latest
addenda, Section 1.4.
2. The installation of electrical wiring from the
electric meter, main control box or service
outlet to the electric appliance. Qualified
personnel must be experienced in such
work, be familiar with all precautions
required and have complied with all
requirements of state and local authorities
having jurisdiction. Reference: National
Electric Code, N.F.P.A. No. 70– latest
addenda.
Read carefully and follow these
instructions.
The oven must be installed in accordance with
local codes, or in the absence of local codes,
with the national fuel code, ANSI Z223.1-latest
addenda, including:
1. The appliance and its individual shutoff
valve must be disconnected from the gas
supply piping system during any pressure
testing of that system at test pressures in
excess of 1/2 psig. (3.45kPa).
2. The appliance must be isolated from the
gas supply piping system by closing its
individual manual shutoff valve during any
pressure testing of the gas supply piping
system at test pressure equal to or less
than 1/2 psig. (3.45kPa).
This unit when installed must be electrically
grounded in accordance with local codes, or in
absence of local codes, with the national
electrical code, ANSI/NFPA No. 70–latest
addenda.
Provisions must be made for adequate air
supply to the unit.
CAUTION
DO NOT OBSTRUCT THE FLOW OF
COMBUSTION AND VENTILATION AIR TO
THE OVEN. KEEP THE APPLIANCE AREA
FREE AND CLEAR FROM COMBUSTIBLES.
Solid state components have a very short life
span when exposed to temperatures above
185°F (85°C), therefore, certain installation
precautions are necessary. The Vectaire SL
ovens have been designed to operate below
this temperature when properly installed. The
following precautions must be observed:
1. Do not obstruct the flow of air through the
vent openings at the top of the oven, or the
flow of room air to the oven bottom or
lower front portion of the burner access
panel.
2