1. Product Features
Name: Wireless Door & Window Alarm
Working voltage: 3V
Standby current: 100uA
Working current: 50mA
Power: 0.15w
1. Type: magnetic induction
2. Sounds an alarm when somebody opens the door or window illegally.
3. Can be free controlled by the wireless remote control.
4. A password of 3 digits can be set, and it won't be lost even if power off.
5. Zone control function. Multiple devices can be controlled by the remote
control at different zones
6. Siren on/off setting
7. Setting of reminder sound when door not closed
8. Setting of reminder sound when door not locked
9. "DING DONG" sound when linked with MH101 Door Phone for use.
10. Triggers MH102 Video Camera to take videos when linked with it for use.
11. RF on/off setting
12. Lock the keypad automatically when entering wrong password 5 times.
13. Sounds an alarm after 4 seconds when triggered.
14. LED indicator when battery low
15. Still sounds an alarm even in the environment of strong magnetism.

2. Installation and Use
1.Take out the insulating piece, and you will hear one "bi", which means correct
insert of the battery.
2.Tear off the protection paper of 3M adhesive tape on the back of MH107, and
stick the magnet part parallel to the alarm, ensuring the gap to be less than
1cm.
3. Function setting
Password setting
Password setting n
* Default password is "1 2 3" d when door not closed
1) . ARM
Press "3" on the keypad and we will hear one beep. 20 seconds later it
is ARMED
2) .DISARM
Enter the correct password and press "3".After one beep it is DISARMED.
(default password is "1 2 3" if it's not revised)
3) .Revise password
In the status of "DISARMED", enter the current password "1 2 3" and press "3", red
light stays on for 3 seconds. Enter the new password "xxx" and enter "1 2 3" again
and press "3", the red light flashes 3 times. New password is successfully set.
("xxx" stands for new password; default password is "1 2 3" if it's not revised)
RF on/off
1) .ON
Enter the password "xxx" and enter "2111" to turn the RF function on. Red light

flashes 3 times. In this case, MH107 can work with other wireless units.
2) .OFF
Enter the password "xxx" and enter "2112" to turn the RF function off. Red light
flashes 3 times. In this case, MH107 can't work with other wireless units and it
will work individually
Siren on/off
1 ).ON
Enter the password "xxx" and enter "2121" to turn the siren on. Red light flashes
3 times. When MH107 is triggered, the siren will sound.
2) .OFF
Enter the password "xxx" and enter "2122" to turn the siren off. Red light
flashes 3 times. When MH107 is triggered, the siren will not sound
Reminder sound when door not closed
1) .ON
Enter the password "xxx" and enter "2211" to turn the sound on. Red light
flashes 3 times.
2) .OFF
Enter the password "xxx" and enter "2212" to turn the sound off. Red light
flashes 3 times.
Reminder sound when door not locked
1) .ON
Enter the password "xxx" and enter "2221" to turn the sound on. Red light
flashes 3 times.
2) .OFF
Enter the password "xxx" and enter "2222" to turn the sound off. Red light
flashes 3 times

4. Reset to default factory
Open the battery cover and take out the battery. After 3 seconds, press and
hold the learn code key, and insert the battery. When you hear three beeps,
it has been reset to default factory. Default password is "1 2 3"
5. Pairing two MH107, Divide into different zones
With the help of the remote control, you can pair two units to be divided into
different zones and managed separately by the same remote.
a. Zone “1”: Open the battery cover of unit "1", press the code button
continuously, at same time press the "1 " button (represent zone 1) of the
remote control for 3 seconds, the red light of the remote control will flash
and beeps twice. Zone "1" is set successfully. The button “1” can
arm/disarm alarm unit "1" installed at Zone 1.
b. Zone “2”:Open the battery cover of unit "2", press the code button
continuously, at same time press the "2 " button (represent zone 2) of the

remote control for 3 seconds, the red light of the remote control will flash and
beeps twice. Zone "2" is set successfully. The button “2 ” can arm/disarm alarm
unit "2" installed at Zone 2.
6. Remark
1).Every step of button operation must be completed within 5 seconds.
2 ).When you enter the password wrongly for 5 times, MH107 sounds a
2-second beep and 10 beeps, and the keypad will be locked for 5 minutes.
After that time, you can use the remote control to unlock the keypad and
re-enter the password.
FCC Statement:
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation.
CAUTION:
Changes or Modifications not expressly approved by the party responsible
could void the user’s authority to operate this device.
NOTE: This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not
occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which
the receiver is
connected.
-- Consult the dealer or an experienced radio/TV technician for help.

Examples of RF Exposure statement:
This equipment complies with the FCC RF radiation exposure limits set forth
for an uncontrolled
environment.This equipment should be installed and operated with a minimum
distance of 20 centimeters between the radiator and your body.
FCC ID: ZAX5E-MH107
This device complies with part 15 of the FCC rules. Operation is subject to the
following two conditions: (1) This device may not cause to harmful interference,
and (2) This device must accept any interference received, including
interference that may cause undesired operation.
After-sale service
Please don't hesitate to call the service hotline, contact the online customer
service or visit Mosaic website.
Hotline: 0769-8544 9889
Email: sales01@mosaichk.net
Website: www.mosaichk.net
Table of contents
Other Mosaic Security System manuals