MOTECK SW200 Series User manual

USER'SMANUAL
SWING
GATEOPENER
SW2OOSERIES
1.50mmax
'l00kg
max 1.50mmax
100k9
max.

lmportantSafety
Advice:
1.Knowledge
oftherelevantelectrotechnical
regulationsisrequired.
2.Training
in
use
andmaintenanceofsafetyequipments
is
necessary.
3.Always
laymainsandconJrolcablesseparately.
4.Testeveryequipment
beforeinitialoperation.
5.
Makefamiliarwiththeuse
ofthesystembeforeinitialoperation.
Contentofthe
Kit:
Part A
Actuator
x2
'- PartB
'1,",.
{:-. *z
(The shorter one
/ on the gate )
't., .
I
:3
,ii,,
pu.t
c
;]'x2
(The lohger one
/ on the pillars)
control Box
\\\ \, \3
Battery Wire
Ix2
Remote Control
WarningLight
xl ft
v.2

Wiring Diagram:
WarninoLiqht
ControlBox
1Scm
Garden
Lamp
Photocell
lnstruction of lnstallation!
1.Keep
aspace
ofsmm
(default
setting
from
factory)betweenthedrivingboltandthe
metalcoverofthemotor.
2.MeasureoutthelengthofEonthe
figurelas36cmor37.5cm.Usethis
point
asacenter
point
forfixingthe
Tformmetal
(Part
B)onthe
gate.
Drilltwoholesonthe
gate
to
fix
the
PartB(the
shorterTformmetal).
-l-
"/\
Photocell
&*
i"
SW2OO Version 1.O Page -l Copyright@

Recommended
Installation
Distances:
ODen RaDge E
90" 15.5cm 36.0cm
100' 14.0cm 37.5cm
3.
Assemblythe
Axis
for
the
motorend,
Part
and
thebolttogether
4.PuttheActuator
onto
PartBonthe
gate.
lvlove
PartCtogether
withthe
Actuator
onto
pillarto
makesure
the
"late iscomplete
closed.
5.Drawahorizontal
linefromthe
center
point
ofthePart
B.Stickthe
PartConthe
pillar
anddrilllhe
twosupposed
holes.Fix
the
PartConthe
pillar.
6.1Fittheactuator
ontothe
PartBandC.
6.2Fitthe
releasescrew
oftheactuator
into
the
sthholeon
PartBandC.
._
n
sw 20o vercion {.o Page -2 -

Connection
Diagram
To
transformer ToBacku Batte
ThermalFuse
230VACin
(12v
DC) DipSwitches
12VDCinputfrommain
PCB
230VAC
out
for GardenLamp
Coloriru[ggtlgl for
motorwire!
Black wire for '
Red wire for +
t2v Dc
E
s
LL
12VAC
oa
Antenna
Gfound
Toexternalopen/close
switch
To
externalGardenLamp
switch
For
externalLEDdisDla
GardenLamDlvlanualButton
n/closel\4anualButton
12VDCoutouttosmallPCB
PHOTOCELL
SENDER
@Q\
PHOIOCELL
RECEIVER o
z
N
sw 200 Version 't,O Page -3-

Transformer
ACWiring :
lnsideofthe
controlbox,thewiring
should
belikethe
photo
ontheleft.
Opening/ClosingLearning:
Please
proceed
thisfunctionbeforeusingthis
product,
otherwisethesystemwill
drive
the
gates
improperly.E.g.:The
gate
can'tclosecompletelyorcan't
opentotheintended
degree
withsomestrokelengthleftunused,
Toactivatethisfunction,
press
"
Auto"buttononthePCBfor3secondswhile
the
PCB
ison.
After
releasethe
'Auto"
button,itwillentertheopening/closinglearning
modeasbelow:
1.
Thesystem
willclose
the
gates
first.
Pleaseremoveanyobstaclecould
possibly
blockthe
gate.
Befo!'etheactuatorsstatl,thewarninglightwillblinkfor3seconds.
ThenActuator2willclosefirst,andthenActuatorclose1secondlater.
2.After3seconds,
Actuator1willopenthe
gate
1fully,
waitingfor3seconds,Actuaior2
will
opentheothef
gate
2fully.
3.After3secondsActuator2willclosefulyfirct,waitingfor3
seconds,Actuatof1willclosefully.
4.Systemrepeatstheactionsof
point
2and3onemoretime.
5.
Afler3seconds,systemchecksoperaiionofActuator1andActuator2together.
6.
Afierlearning
process
succeeded.thesystemisreadyforuse.
lfthesystemblinksafterthislearningmode,whichmeanslearninginvain,
please
makesurethatthere'snoobstacleontheway,
thentryagainto
Vigger
thelearningmode.
Auto
SW2O0 Version l.O Page -4 - copyright@

RemoteLearning
(activation
ofremotecontrolfor
gate
andlampoperation):
Toaciivatetheremotecontrolservice,
pleaseproceed
the
following
steps:
A.RF
gate
learning:
(for
Open/Closethecales)
'1.
Press
"RF"
key
onthe
PCBfor
over
2
seconds
whilethePCBison.
2.You'llseetheLEDlighton
(leafning
modeentered)
pleasepress
anykeyontheremoiecontrol,
LEDwillnowblinkfor3iimes
(learning
succeeded)
orlightoffafter10seconds
without
blinking
(learning
failed,
please
tryagainthewhole
process).
3.Please
re0eat
thesteD
1and2
toactivateanother
remote
control.
otherwisetheunlearnt
remote
controlwon't
berecognizedbythesystem.
B.RFlamplearning;(forTurningOn/OfftheGardenLamp)
Proce€d
wilh
"RF
lamp"
keyon
the
PCB
andanotherkeyontheremoteconirol
asstep
1-3
above.
Note:UptoI differentRFremotecontrolkeyscan
belearntforeachfunction
bythissystem
(gates
&GardenLamp).
RemoteControl:
Choose
two
of
the
fourkeys
toproceed
RFlearning.
Therestofthekeysareavailablefor
other
purposes
suchas
GarageDoorOpener.
Theremotecontrolhas4keysonit,andchoosetwoof
themto
proceed
RFlearningfor
one-key
gate
control
andlamp
controlseparately.
Operation
(open,
closeand
stop)by
remote
control:
Therenroteoperation
isvery
simple;onekey
press
willopenthe
gate,
next
press
tostop,nextto
closethe
gate.
nexttostop...andsoon.
Whenopeningthe
gates:
1.
Warninglightwill
blink
for
3seconds,thenActuator1opens,4secondslatertheActuator
2opens.
2.lfthe
gate
hitssomething,Actuatorsrevefsefor3secondswarning
Jighl
blinksuntilnextcommand
recetved.
Whenclosingthe
gates:
1.Warning
lightwillblinkfor3seconds,
then
Actuator
2closes,4secondslatertheActuator1
closes.
2.lfthe
gate
hits
something,
Actuators
reversefor3secondswarninglightblinks
untilnextcommand
recetved.
Lampcontrol
(on
andoff)by
remote
control:
Simplyswitchonandoffthelampbythekeywhichhad
proceeded
the
"RF
lamp"
learning.
Remark:The
gate
operationworks
properly
onlyafter
sucessfulOpening/ClosingLearning,
sW20o Version1.0 Page.5. copyright@

Photocell
(Optional):
'1.
DuringOpening:
Whentheloopof
photocells
hasbeen
intercepted,systemwill;
A.
ignore,iftheActuator
2hasbeenactivated.
OR
B.halt,
iftheActuator
2hasn'tbeenactivated
yel.
2.
DuringClosing;
Whenthe
loopof
photocells
hasbeenintefcepted,
systemwillstopclosingthe
gates
andthen
openboth
gates
simultaneously
untiltheset
posilion.
Autoclose:
30seconds
or60seconds
later
(only
whenthis
functionisenabled,dependson
your
settingof
key1ofdipswitch),
warning
light\^/illblinkfof3secondsthen
Actuator2closes,4secondslater
Actuator
'1
closes.
Whenthe
process
finished,warninglightwillbeswiiched
off.
Manual
gates
controlon
thePCB:
1.Theoperation
isthesameas
remote:onekey
press
willopenthe
gate,
next
press
tostop,nextto
close
the
gate,
nextiostop...andso
on.
2.Optional
handsetorexternal
wallbuttonisavailable.(Connected
toO/C&GNDterminals)
Manual
lampon:
Simplyswitch
onandoffthelamp
bythe
"[,4anual
lampon"key.
ClearRF
memory:
Press
"Clear"
keyonthe
PCBfofover2seconds
while
the
PCBison.
You'llseethe
LEDblinking
for2.5secondsthentheRFmemory
hasbeencleared.
Reset;
Press
"Clear"
keyonthePCB
andinputAC
power;
keep
pressing
"Cleai'
keyforover2seconds.
You'llseethe
LEDblinkfor2seconds
andlightonfor3secondsthen
light
off.
Oncethementioned
actionshavebeencarried
out,allRFdatawillbecleared.
Quick
release:
Loosenthe
releasescrew
SW200 Version
1.0 Pag6
'6 - copyright@

Settings of DipSwitches:
Thedefault
settingofdipswitches.
Kev
No. Function ON OFF
1Auto-Close Yes No
2Auto-CloseTimer 60Sec 30Sec
3GateType HeavyGate Light
Gate
4-8 Current
Limit selected unselected
Approx.current
Iimitvaluesfordifferentdipswitchsetting:
srvitch
4 switch5 slvitch6 srvitch7 switch8 Alto{f
l.0A 2.04 3.0A 4.5A' 5.2A
l\,4aximum
Current
Limit
(means
also
theworst
sensibility,couldshortenthelifeofmotor,
please
trylowercurrentlimitfirst)
Second
HighestCurrentLimit
l/linimumCurfent
Limit
When,userswitchesseveralswitcheson,
forsafetyreason,systemwillchoosethelowest
(switch
4instead
ofswitch
6orB)currentlimit
setting
automatically.
ON
I
K=
K
n
2
NX
n
3
g
I!
€5l
K
!K
!1l
K
!8l
ON
E€€#€trNEi
€nEnnnEEl
r z r'"
i-'1.''6-'"i--ii
"
ON
[lt'ErE€Ei
tEE[[E[€i
L : : '.i--j--i--
i---s
-
ON
EX[[ttf;i
€Enixtrnq[j
r21156?8
ON
IKXU&EKE:
=EEI'X,UXEXXI
1214567E
sw 200 Version 1.O Page -7 .copyright@

I
6
I
o
o
I
o
tr
o
o
tt
E
OptionalAccessories:
I Set of Photocell
ODeration
ofPhotocell:
Seleci
a
proper
installationsite,
whefethesenderandreceivercanbealongthesameline :-:--==-:
andat
thesameheight.Connect
totheopeneisPCBaswiringdiagramabove.
Poweronthe
system,tryandseeif
itworks
pfoperly
byinterrupttingthelRbetween
thesender
andreceiverfortimes.Therelay
in
the
receivershouldrespondaccordingly
whileLEDswitchesON
andOFF.
\\'ith
photocell
wellinstalled,whileit'striggered
dudngopeningihe
gates,
the
gates
willignore
theinte|ruptionand
open.!\hileit'striggeredduringclosingthe
gales,
the
gates
willfevefse
fof
3secondsandstopand
warminglightwillkeepblinkinguntillnextcommandsent.
Specifications:
[/]odel ill OVVZUU
PowerSupply 230V
AC110%
50Hz:
'l
10VAC
60Hzavailable
Powerforl\,4otor 12
\/na
I\ilaximum
GateWejght 200KGS
(100+100KGS)
It4aximum
GateWdthl '1.slVI
- 1.5[I
{1oFeet)
Stroke
Length 330mm
(13in)
Dfive il.,'rl' E
90"Operating
Time around15Sec
Open
Range
DutyCycle 20"/"
Operation
Teml l,t -20-65"C
Ovefload
Protection Yes
.Backup
RechargingBatter)l.f.:9!rlldgJ!i Yes
(
NolIncludingBattery12V.7
AH)
AutoGateClose , Adjustable
timer
(off/
30/60sec)
...,::
,nal,,
.: 'arning
Light/Photocell/Back-upBattery
RFCariage 315lVHz/433.92N,4Hz
ControlRange 't,rl Approx.30-50l\leters
SW2O0 Version 1.0 Page -8- copyright@
Table of contents
Popular Gate Opener manuals by other brands

GiBiDi
GiBiDi FLOOR 830 manual

Power Master
Power Master rsw Installation and owner's manual

HySecurity
HySecurity Nice 1500 Series Installation & reference manual

ALLOMATIC
ALLOMATIC SW-350DC installation manual

ALLOMATIC
ALLOMATIC TORO 24 installation manual

Tecnoautomazione
Tecnoautomazione LIRA FTCLY5TN quick start guide