Motroline MC101 Instruction Manual

CONTROL BOARD
MC101
USER / INSTALLER MANUAL
ÍNDEX
00. CONTENT
01. SAFETY INSTRUCTIONS
standards to follow | page 01.B
02. THE CONTROL BOARD
technical specifications | page 01.B
dippers function | page 01.B
connectors | page 02.A
03. CONFIGURATION
transmmiter’s configuration | page 02.B
functionalities | page 03.A
instalation process | page 03.B
04. DIAGNOSIS
failures diagnosis | page 04.A
motor diagnosis | page 04.A
05. CONNECTION SCHEME
component connection to the control board | page 04.B
v1.0
REV. 05/2014
1
ON
2 3 4

01. SAFETY INSTRUCTIONS
STANDARDS TO FOLLOW TECHNICAL SPECIFICATIONS
DIPPERS FUNCTION
02. THE CONTROL BOARD
ATTENTION:
To ensure the safety of people, it is important that you read all the following
instructions.Incorrect installation or incorrect use of the product can cause physical
injury and material damage.
Keep these instructions in a safe place for future reference.
This product was designed and produced strictly for the use indicated in this
manual. Any other use, not expressly indicated here, could compromise the good
condition/operation of the product and/or be a source of danger.
ELECTROCELOS SA is not responsible for the improper use of the product,
or other use than that for which it was designed.
ELECTROCELOS SA is not responsible if safety standards were not taken
into account when installing the equipment, or for any deformation that may occur to
it.
ELECTROCELOS SA is not responsible for the safety and proper operation
when using components not sold by them.
Do not make any modifications to the operator components and / or their
accessories.
Beore installation unplug the automatism from the source of power.
The installer must inform the client how to handle the product in case of
emergency and provide this manual to user.
Keep remote controls away from children, to prevent the automated
system from being activated involuntarily.
The customer shall not, under any circumstances, attempt to repair or tune
the automatism. Must call qualified technician only.
Connect the automatism to a 230V plug with ground wire.
Control board for indoor use.
01.A 01.B
Power supply AC V /Hz
Motor output
OP Transmitters
Maximum memory capacity
Working temperature
Incorporated Radio Receptor
Auxiliary accessories output
W máx.
bits or Rolling Code
Codes
Input Fuse standard Øxmm FALV
°C to °C
, Mhz
VDC W mA máx.
ON
OFF
1 2 3 4
Dip
Dip
LEGEND: Central
Dippers Scheme in
standard mode.
Enables automatic closing after
pause time.
Disables the automatic closing.
Enables the use/programming of
buttons either in transmitters as in
push buttons.
button opens and the other closes.
Enables the use/programming of
only button in transmitters and
push buttons with the function
openstopclosestop ....
Dip
Disables the PRESENT MAN
function in closing maneuvers.
Enables the PRESENT MAN function
in closing maneuvers.
it’s necessary to keep the key
pressed down to close.
Dip Disables the photocells use
CN.
Enables the photocells use
CN.
ON (up) OFF (down)

CN2 CN1
CONNECTOR’S DESCRIPTION
01 230V Line Input (phase) - PH
02 230V Line Input (neutral) - NEUT
03 Motor’s Output - Common - COM MOT
04 Motor’s Output - Closing - CLOS
05 Motor’s Output - Opening - OPEN
06 Photocells power supply output - 12VDC
07 Common output - COM
08 Opening push-button input (NO) - UP
09 Closing push-button input (NO) - DOWN
10 Photocells input (NC) - PHOTO
02. CONTROL BOARD
CONNECTORS TRANSMITTERS CONFIGURATION
03. CONFIGURATION
02.A 02.B
CN CN
Motor:
04 and 05 The motor phases must be connected in these two terminals. If
the motor direction is the opposite to the desired simply switch the two
wires to reverse direction.
Security circuit - Photocells:
07 (COM) and 10 This circuit allows connection of all photocells types.
This device intervenes only during the pause time and during closure. In
pause time it keeps the automatism opened. When it is activated during
closing maneuvers, it stops and starts a complete automatism opening.
Mecanic push-button:
07 (COM), 08 e 09 This circuit allows the connection of mechanical
push-buttons with two button for opening and closing.
NOTA You can, with a one button’s push-button , control the opening and
closing of the automation in step mode (open-stop-close-stop (...) always
with the same button. To enable this feature, you must put the DIP2 to OFF
and connect the push-button only at terminal 08 - UP and terminal
07-COM.
Before proceeding to the control board configuration, please note the following
points listed in the table below in order to better understand the control board
function:
Button 1
Button 2
Button 3
Button 4
[MX4SP]
Button 1
Button 2
Button 3
Button 4
[MXS4SP]
New transmitters configuration keys DIP ON
Press the P button once and the LED CODE will light during sec.
While the CODE LED is light up, press the opening desired transmiter key during
sec and CODE LED will blink twice.
The CODE LED will be light up again and you must now press the transmitter key
for closing during sec and CODE LED will blink twice.
Let the CODE LED go off and the transmitter is now configured.
New transmitters configuration key DIP OFF
Press the P button once and the LED CODE will light up during sec.
While the CODE LED is light up, press the desired transmiter key during sec and
CODE LED will blink twice.
Let the CODE LED go off and the transmitter is now configured.
NOTE: After you program the first transmitter, the control board will only accept new
transmitters of the same type. For example, if the first programmed transmitter is set
for rolling code, the central will only accept more rolling code transmitters until a
maximum of transmitters.
Programming remote controls without access to the control
board
• Using an already configured TRANSMITTER:
Press transmitter’s and keys simultaneously for sec.
Press the new transmitter’s desired opening key for sec.
Wait sec and press the desired closure key for sec.
Wait sec and can now use the new device.
•Using one PUSHBUTTON connected to the control board:
Press for seconds simultaneously the opening and closing buttons.
Press the new transmitter’s desired opening key for sec.
Wait sec and press the desired closure key for sec.
Wait sec and can now use the new device.
Erase all configured transmitters
Press and hold the P key for sec. The CODE LED will remain light up the entire
time and will start to blink at the end of sec.
Release the P key and LED CODE will stop flashing and remain lit for sec so that
you configure a new transmitter note the DIP position.
If you do not want to configure new transmitter, let the CODE LED go off without
pressing any key.

03. CONFIGURATION
TRANSMITTERS CONFIGURATION
FEATURES
FEATURES
INSTALLATION PROCESS
03.CONFIGURATION
03.A 03.B
New transmitters configuration keys DIP ON
Press the P button once and the LED CODE will light during sec.
While the CODE LED is light up, press the opening desired transmiter key during
sec and CODE LED will blink twice.
The CODE LED will be light up again and you must now press the transmitter key
for closing during sec and CODE LED will blink twice.
Let the CODE LED go off and the transmitter is now configured.
New transmitters configuration key DIP OFF
Press the P button once and the LED CODE will light up during sec.
While the CODE LED is light up, press the desired transmiter key during sec and
CODE LED will blink twice.
Let the CODE LED go off and the transmitter is now configured.
NOTE: After you program the first transmitter, the control board will only accept new
transmitters of the same type. For example, if the first programmed transmitter is set
for rolling code, the central will only accept more rolling code transmitters until a
maximum of transmitters.
Programming remote controls without access to the control
board
• Using an already configured TRANSMITTER:
Press transmitter’s and keys simultaneously for sec.
Press the new transmitter’s desired opening key for sec.
Wait sec and press the desired closure key for sec.
Wait sec and can now use the new device.
•Using one PUSHBUTTON connected to the control board:
Press for seconds simultaneously the opening and closing buttons.
Press the new transmitter’s desired opening key for sec.
Wait sec and press the desired closure key for sec.
Wait sec and can now use the new device.
Erase all configured transmitters
Press and hold the P key for sec. The CODE LED will remain light up the entire
time and will start to blink at the end of sec.
Release the P key and LED CODE will stop flashing and remain lit for sec so that
you configure a new transmitter note the DIP position.
If you do not want to configure new transmitter, let the CODE LED go off without
pressing any key.
Adjusting the Working Time and the Pause Time
The Working Time can be set to sec ,sec and sec .
To set any of these values, press the P button as many times as needed until the
desired option is defined while the engine is running.
For each pulse in the P button with the motor running, the CODE LED will flash
once for sec, twice for sec and thrice to sec.
The Pause Time can be set to sec, sec and sec.
To set any of these values, press the P button repeatedly until the desired option is
defined while the engine is paused must enable autolocking by putting DIPON.
For each pulse in the P button with the motor opened in pause time, the CODE LED
will flash one time for sec, two times for sec and three times to sec.
NOTE:
The Working Time should be set to a value above the actual required working time.
For example, if the automatism needs sec to go all the course, you must set the
Working Time for sec.
Setting the motor working direction
To verify that the operating direction is correct, proceed as follows:
With a configured transmittergive order with the key that you have programmed in
the first place and the automatism must begin to open. If it starts to close, swap the
motor wires at terminals and from the CN connector.
Safety photocells NC
To enable the use of photocells, place the Dipper to OFF.
Safety photocells act as follows:
In opening maneuvers, has no action.
When opened, the photocells cause the gate to remain open if there is an obstacle in
front of them.
In closing maneuvers, the gate stops and starts to open immediately, stopping at the
end of the working time or at the end of the opening limitswitch.
Connect the control board to a Vpower supply terminals and CN.
Configure the Dippers according to the used devices and the desired type of
operation.
Configure transmitter.
NOTE: Be aware of any component connected to the control board as the motor or
photocells.
This control board can operate all types of motor which doesn’t exceed W of
power and photocells which doesn’t exceed a consumption over mA.

04. DIAGNOSIS
FAILURES DIAGNOSIS
MOTOR DIAGNOSIS
COMPONENT CONNECTION TO THE CONTROL BOARD
05. CONNECTION SCHEME
04.A 04.B
DOOR OPENS BUT DOESN’T CLOSE
Put the DIP ON to disable the photocells. Try to close the automatism.
If it closes, the problem is in photocells. If it doesn’t close, the problem is in the control
board or in the motor. Do the test below to diagnose.
MOTOR DOESN’T WORKING
Do the test below to diagnose if the failure is in the engine or in another
component. If the engine is running check the following:
Control board’s power supply and control board’s entrance fuse.
The control board comes from factory with a AV fuse. This can be changed
according to the motor consumption to a maximum of AV!
The test below serves only to identify if the problem is in the motor or in the control
board. If the engine is running connected to a power source, it means that the
problem is in another component, such as control board or power supplies.
All tests must be performed by professional technicians due to serious danger
associated with the misuse of electrical systems!
To detect which components
have problems in an installa-
tion, it is sometimes necessary
to perform a test with a direct
connection to a 230V power
supply.
NOTES:
The order to connect the
capacitator with the automa-
tism wires is not important as
long as you connect one with
the Brown wire and the other
with the Black wire;
The common should always
be connected to the power
supply.
POWER SUPPLY
230V
CAPACITATOR
Ground
wire
Common
Black
Brown
ROLLING
MOTOR
V
DV NCNA COM
12/24V
DV 12/24V
~ ~~ ~
Photocells
Push-Button 1 button
(DIP2 OFF)
Push-Button
2 buttons
(DIP2 ON)
1
ON
234
1 2 3 4 5
F N COM CH AP
V MOTOR
1 2 3 4 5
UP DOWN
BOTÃO FOTOCOM12V
RECEPTOR
FUSE ØX
FALV
LED CODE
P
CN
P
CN
MOTOR
Table of contents
Popular Control Unit manuals by other brands

Vega
Vega VEGADIF 65 operating instructions

DSEGenset
DSEGenset DSE7400 Operator's manual

SUNSCAN
SUNSCAN SR868C8 quick start guide

Emerson
Emerson Keystone EPI2 Installation, operation and maintenance manual

Midland
Midland A-1075 Installation, operation & maintenance manual

pizzato
pizzato CS AR-04 Series operating instructions

Danfoss
Danfoss PCV-VFGS 2 DN 150-250 installation guide

Maker Factory
Maker Factory MAKEVMA404 user manual

National Instruments
National Instruments NI 6520 user guide

Olfer
Olfer CAS-24V-ZHAGA-4P-40-DA instruction manual

HomeMatic
HomeMatic HM-PB-2-WM Installation and operating manual

Nortek
Nortek tvone CM-HDBT-2OUT-1ETH quick start guide