User Guidelines –VNC Quick Guide 09-10-2020 Version 001
_____________________________________________________________
User Guide
Flosense 3.0 & 4.0 VNC Quick Guide
P a g e | 1
User Guidelines –VNC Quick Guide 09-10-2020 Version 001
1. Introduction
This Quick Guide serves as an easy-to-use guide to help make your VNC connection to the
Flosense Manifold system as simple as possible. However, beware that the Quick Guide is
a supplement to the full VNC guide and for that reason cannot stand alone. So please ensure
that you have read the relevant User guide thoroughly before connecting your Flosense
system to your Machine UI or PC with VNC.
Disclaimer
Costs connected to any damages to the products, PC or Machine UI caused by lack of
following the instruction manuals, will be at the customers own expense.
P a g e | 2
User Guidelines –VNC Quick Guide 09-10-2020 Version 001
2. Connecting locally to PC or Machine UI
For connecting through a common router, go to page 8
•Connect the Flosense display to your unit with an ethernet cable.
The Flosense display needs to be Turned OFF, before connecting the display to the Machine
UI or PC as seen on the picture below. Once they are connected you can turn on the
Flosense display.
•Open “Network and Internet” in Windows.
P a g e | 3
User Guidelines –VNC Quick Guide 09-10-2020 Version 001
•Open “Network and Sharing Center”
•Press “Ethernet” (or Local Area Connection) as shown below.
P a g e | 4
User Guidelines –VNC Quick Guide 09-10-2020 Version 001
•Press “Properties” as seen below.
•Select “TCP/IPv4 (Internet Protocol Version 4) and click “Properties” as seen below.
P a g e | 5
User Guidelines –VNC Quick Guide 09-10-2020 Version 001
•Enter the network data as seen below
For the subnet mask, it is highly recommended to input 255.255.0.0 as seen above.
When entering the IP-address, if you have input the recommended subnet mask, the first 6
digits of the IP address will be assigned to your PC/Unit by your network and you can select
the remaining digits yourself.
The first 6 digits will almost always be 192.168 as shown above, but the remaining digits
may be any number you choose between 1 and 255.
After entering the data above, click OK and your network should be ready to connect.
P a g e | 6
User Guidelines –VNC Quick Guide 09-10-2020 Version 001
•Open the Global settings menu on your Flosense unit
•Open the Network settings menu as seen below (red circle)
•Set IP ALLOCATION to STATIC and Enable VNC
•Enter the same Subnet mask as previously.
•Enter a different IP-Address than previously.
•Do not enter anything in gateway
•Exit settings on your Flosense unit
P a g e | 7
User Guidelines –VNC Quick Guide 09-10-2020 Version 001
IMPORTANT!
The Flosense display need to have 12 digits in the IP-address field in order to successfully
register the IP-address. This means that if you wish to use the IP-address 192.168.4.5, you
will need to enter 192.168.004.005 in the Flosense software.
•Connect the Flosense display to your unit with VNC software (Here shown with
TightVNC)
Make sure that you have connected your manifolds to your Flosense display before
connecting the units with VNC, as the VNC connection is lost if the Flosense display is
turned off or rebooted.
P a g e | 8
User Guidelines –VNC Quick Guide 09-10-2020 Version 001
3. Connecting through a common router
If you are connecting your Flosense display locally to a PC or the Machine UI, ignore this
part and go back to page 1.
In order to be able to connect the Flosense unit to your system using a router, the router
needs to have DHCP, for it to be able to designate an IP-address to the Flosense display.
•Connect the Flosense display to your router with an ethernet cable.
The Flosense display needs to be Turned OFF, before connecting the display to the router
as seen on the picture below. Once they are connected you can turn on the Flosense
display.
P a g e | 9
User Guidelines –VNC Quick Guide 09-10-2020 Version 001
•Open the Global settings menu on your Flosense display
•Open the Network settings menu as seen below (red circle)
•Toggle IP ALLOCATION to DYNAMIC and Enable VNC.
•Exit and enter the Network settings. The IP-Address should now appear.
•Connect the Flosense display to your unit with VNC software (Here shown with
TightVNC)
P a g e | 10
User Guidelines –VNC Quick Guide 09-10-2020 Version 001
Make sure that you have connected your manifolds to your Flosense display before
connecting the units with VNC, as the VNC connection is lost if the Flosense display is
turned off or rebooted.
P a g e | 11
User Guidelines –VNC Quick Guide 09-10-2020 Version 001
Change log
Date of change
Change
Version
09-10-2020
VNC Functionality implemented on Flosense
systems
001

Other manuals for Flosense 3.0

3

This manual suits for next models

1

Other MOULDPRO Controllers manuals

MOULDPRO Flosense 3.0 User manual

MOULDPRO

MOULDPRO Flosense 3.0 User manual

MOULDPRO Flosense 3.0 User manual

MOULDPRO

MOULDPRO Flosense 3.0 User manual

Popular Controllers manuals by other brands

Grozone Control Dual Zone CO2 Controller manual

Grozone Control

Grozone Control Dual Zone CO2 Controller manual

FUTABA GYC440 instruction manual

FUTABA

FUTABA GYC440 instruction manual

HYDRO-RAIN HRC 100-C user manual

HYDRO-RAIN

HYDRO-RAIN HRC 100-C user manual

Allen-Bradley SoftLogix 5800 user manual

Allen-Bradley

Allen-Bradley SoftLogix 5800 user manual

EUCHIPS DMX801 manual

EUCHIPS

EUCHIPS DMX801 manual

Woodward 505 Installation and operation manual

Woodward

Woodward 505 Installation and operation manual

Datakom DKG-108 user manual

Datakom

Datakom DKG-108 user manual

Swagelok RHPS Series user manual

Swagelok

Swagelok RHPS Series user manual

Ruida Technology RDC6332G user manual

Ruida Technology

Ruida Technology RDC6332G user manual

LOVATO ELECTRIC ATL600 instruction manual

LOVATO ELECTRIC

LOVATO ELECTRIC ATL600 instruction manual

MKS 653B manual

MKS

MKS 653B manual

Embedded Artists LPCXpresso user guide

Embedded Artists

Embedded Artists LPCXpresso user guide

Montalvo Z4-UD Technical manual

Montalvo

Montalvo Z4-UD Technical manual

Motoman XRC 2001 instructions

Motoman

Motoman XRC 2001 instructions

Mercoid Series MPC Specifications-installation and operating instructions

Mercoid

Mercoid Series MPC Specifications-installation and operating instructions

AC STAG 400 installation manual

AC

AC STAG 400 installation manual

BobsCNC KL7 Series Assembly manual

BobsCNC

BobsCNC KL7 Series Assembly manual

Minarik MAC Series user manual

Minarik

Minarik MAC Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.