symptom possible fault solution
DMX module is not
identified by the LFXHub
a connected lamp of a
DMX dimmer pack will
not come on
the software of the LFXHub is not upgraded to
DMX
check if the LFXHubs´ software is ready for
DMX > page 6
DMX dimmer pack is not powered
load latest software for the
LFXHub
> page 11
power up the DMX dimmer
pack
connected lamp is switched off
connected lamp is broken switch on lamp
exchange lamp
value of "Dimmer max." is too low
DMX-ID of the transmitter (LFXHub) is different
to DMX address of the dimmer pack
increase "Dimmer max."
set up DMX-ID
- at the LFXHub or
- at the dimmer pack
a connected lamp at the
dimmer pack is still on
when the DMX-TX mo-
dule is unplugged
the unit does not work
although all settings are
correct
specifications of the dimmer pack manufacturer
might prevent the connected lamps from swit-
ching off.
Partially lamps will be dimmed to 50%. This ef-
fect is not part of the DMX-512 specifications.
Did you use the device in wet environment?
Humidity might be to strong inside the DMX-TX
module.
prior unplugging the DMX mo-
dule turn "EFFECT" to position
"OFF/set-up"
Leave the device dehumidify at
a warm and dry place for at
least one hour.
2006-0410V1e http://www.movie-inter.com
Possible problems using the LFXHub might be solved here.
Basic conditions for operation
1. The DMX-TX module and the LFXHub, especially the power cord, have no damages.
2. The operation voltage of the LFXHub is 220 - 240 VAC /50 Hz.
3. The built-in main fuse is turn on.
4. The DMX-TX Modul is properly connected to the socket "DMX IN/OUT" of the LFXHub.
In case of a malfunction of the LFXHub the internal fuse of the power supply could have been triggered.
This internal fuse is self resetting. Please wait 10 minutes and try again. Do not open the the LFXHub, it is
not necessary.
If you have a problem which can not be solved by this manual, please disconnect the DMX-TX mod-
ule from the LFXHub / DMX line and contact movie-intercom.
cleaning the unit
ONLY clean the unit when disconnected completely from all cables!
Use a clean slightly wet cloth.
disposal
In order to avoid any possible effects resulting from the disposal of electrical an electronic equipment con-
taining substances damaging the environment and human health, the European Parliament and Council di-
rectives
2002/96/EC on waste electrical and electronic equipment (WEEE) and
2002/95/EC on the restriction of the use of certain hazardous substances in electrical and elec-
tronic equipment (RoHS) have been transferred into national law in all EU member states.
The product you have purchased was developed in line with the current state of the art in an
environmentally friendly manner and with the view of recycling.
The product is labelled with the symbol illustrated above. If you wish to dispose this product,
this symbol obliges you to do so separately from industrial sorted waste.
Waste equipment should be shipped to movie-intercom. We will dispose the waste for you.
Electrical equipment does not belong in regular waste.
user manual DMX-TX module for the LFXHub
9. Trouble shooting
page 12 of 16