4JA52

WARNING : TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS,
PLEASE OBSERVE THE FOLLOWING :
READ AND SAVE THESE INSTRUCTIONS
1]. To ensure the success of the installation, be sure to read the instructions and review the diagrams
thoroughly before beginning.
2]. To avoid possible electric shock, be sure electricity is turned off at the main power box before wiring.
All electrical connections must be made in accordance with local codes, ordinances and/or the
National Electric Code. If you are unfamiliar with the methods of installing electrical wiring and
products, secure the services of a qualified and licensed electrician as well as someone who can
check the strength of the supportive ceiling members and make the proper installations and
connections.
3]. Make sure that your installation site will not allow rotating fan blades to come in contact with any
object. Blades should be at least 2.3 M from floor when fan is in operation.
4]. If possible, mount ceiling fan on a ceiling joist - the joist must be able to support the motion and weight
of the moving fan. If the fan will be mounted on a ceiling outlet box, a 4" x 2-1/8" deep METAL octagon
box is required ; one UL listed as " suitable for fan support ". The box and its supporting members must
not be able to twist or work loose. DO NOT USE PLASTIC BOXES. Installation on a concrete ceiling should
be performed by qualified personnel.
5]. Blades should be attached after motor housing is hung and in place. Fan motor housing should be
kept in carton until ready to be installed to protect its finish. If you are installing more than one ceiling
fan, make sure that you do not mix fan blade sets.
6]. After making electrical connections, spliced conductors should be turned upward and pushed
carefully up into outlet box. The wires should be spread apart with the grounded conductor and the
equipment - grounding conductor on one side of the outlet box and the " HOT " wires on the other side.
7]. Electrical diagrams are for reference only. Light kits that are not packed with the fan must be UL listed
and should be installed per the light kit's installation instructions.
8]. After fan is completely installed, check to make sure that all connections are secure to prevent fan
from falling and/or causing damage or injury.
9]. The fan can be made to work immediately after installation - the bearings are adequately charged
with grease. So that, under normal conditions, further lubrication should not be necessary
10]. The fan must be turned off and stopped before reversing fan direction.
11]. This fan is suitable for outdoor Damp.
P1

P2
OFF OFF OFF
Turn off power at breaker
box to avoid possible
electrical shock.
Use metal outlet box suitable for
fan support.
Secure outlet box directly to the
building structure using wood
screws (included).
Outlet box must support 40 lbs min.
Install mounting bracket
to Outlet box in ceiling
using washers and the
mounting screws
provided with the outlet
box.
2. 3.
4.
Do not use existing
mounting bracket,
replace it with new
mounting bracket from
box.
Do not use existing
mounting bracket,
replace it with new
mounting bracket from
box.
Outlet Box
Mounting
Bracket
1.Unpack and inspect fan carefully to be certain all contents are
included.
1.Unpack and inspect fan carefully to be certain all contents are
included.
Yoke cover
Mounting Bracket
Canopy
Downrod
Fan assembly
Blade holder
Mounting Screw 2pcs
Spring Washer 2pcs
Lock Washer 2pcs
Wood Screw 2pcs
Tooth Washer 2pcs
Blade Balance Kit 1pc
Blade Screw 13pcs
Paper Washer 13pcs
Wire nuts 3pcs
Pull Chain Knob 1pc
Motor screw 9pcs
Hardware bagHardware bag
Blade
5. Yoke & Downrod Assembly5. Yoke &Downrod Assembly
Yoke
Cotter Pin
Cross Pin
Downrod
Wires
Yoke cover
Canopy
Downrod Set Screw
Cross Pin
Yoke
Downrod
Cotter Pin
(1)
Take off cross pin and cotter pin from downrod.
(3)
Insert the cross pin through yoke & downrod
and secure with cotter pin.
(4)
Tighten both downrod set screws to further
secure downrod, then pull down the yoke
cover to cover yoke.
(2)
Feed motor lead wires through yoke cover,
canopy and downrod and insert downrod
into yoke.

P3
Lift fan assembly onto
mounting bracket.
Carefully lift fan assembly onto mounting bracket.
Rotate fan so that the groove on the ball engages
the ridge in the mounting bracket.
Ridge
Ball Groove
Mounting
Bracket
Mounting
Bracket
6. Hanging the fan6. Hanging the fan
4.Make Wire Connection4.Make Wire Connection
7. Making wire connection7. Making wire connection
Follow diagram below and make sure that all exposed wires are secured inside wire nuts.
Note : Wires from house may vary in color and may not include ground wire ( green ).
After wiring is completed, gently push wires into junction box with nuts pointing upward.
Secure with twist - lock wire nuts (Included).
From House From Fan
( from downrod )
( from mounting bracket )
( for ground wire )
( for light kit )
(AC-N)
(AC-L)
(motor-N)
(motor-L)
1.Push up the Canopy until the two screws on mounting bracket
are engaged with Key Holes in canopy.
2.Rotate the canopy slightly until the two screw heads are in the
small end of the Key Holes.
3.Tighten both screws.
8. Install the canopy8. Install the canopy
Key Holes
Canopy
Screw
Yellow
Green
Orange
Brown
Blue
Yellow
Green
Yellow
Green
Brown
Blue

P4
9. Blades installation9. Blades installation
Attach blade to blade holder with
blade screw & rubber washer provided.
Make sure that all screws are firmly tightened.
Mount blade assembly to motor
housing by motor screws provided.
NOTE: Do not bend blade holder to prevent wobble.
10. Blades assembly to motor10. Blades assembly to motor
Motor Screw
Blade Assembly
12. Turn the power on - your fan is ready for operation.12. Turn the power on -your fan is ready for operation.
Insert wires existing from Light Kit Fitter by passing through center hole and
attach Light Kit Fitter to Switch Housing Cover with threaded tube and /or
fasten with spring washer and hex nut.
11. Make wire connections for light kit if applicable11. Make wire connections for light kit if applicable
Screw
Blade
Paper Washer
( 1 ). Blue wire from Light Kit to blue wire
from fan and connect by wire nut.
( 2 ). Orange wire from Light Kit to orange wire
from fan and connect by wire nut.
Switch Housing
Screw
Wire Nut
Switch Housing
Cover
Orange Wire
Light Kit Fitter
Orange Wire
Blue Wire
Blue Wire
Attach switch housing cover and light kit assembly to switch housing by 3 original screws.
Table of contents
Other Mr.Ken Fan manuals
Popular Fan manuals by other brands

twin city
twin city ES-52 Installation, operation & maintenance manual

Impecca
Impecca FanFair FSF-1612 user guide

Envirovent
Envirovent PIV Installation and user guide

inVENTer
inVENTer Aviant installation instructions

Hunter
Hunter 22720 Parts guide

Kendal Lighting
Kendal Lighting AC-24246 installation instructions