MC112FL User Manual ML47766, Rev. 02 July 2007
Safety Requirements
Caution!
To reduce risk of electrical shock and fire and to maintain proper operation,
ensure that the safety requirements stated hereunder are met!
Before Installing
Power Ensure that all power to the MC112FL is cut off. Specifically, disconnect the
MC112FL power cord from the power source (line/mains).
Inspection Ensure by visual inspection that no part of the MC112FL is damaged.
Covers The optical connectors of the MC112FL must be covered with dust caps at all
times until they are about to be connected.
Site Reserve one of the following sites for the MC112FL:
– 443 mm x 44 mm x 179 mm (19 in x 1U1x 7 in) space in a 19-inch rack
or
– Flat, stable, non-conductive, static-free surface (e.g., desktop or shelf).
Before Powering On
Temperature Operate the MC112FL only at a location where the ambient temperature is in
the range 0 to 40 oC (32 to 104 oF).
Humidity Operate MC112FL only at a location where the ambient humidity is non-
condensing and in the range 5 to 90 %.
Cooling Air Ensure that the air-flow around the MC112FL and through the air vents is not
obstructed. In addition, ensure that there is a clearance of at least 25 mm (1
inch) between the air vents and nearby objects.
Power Source Ensure that the power source (line/mains) can supply:
100 to 240 Vac, 0.8 A at 60/50 Hz
Power Cord The ac power cord of the MC112FL must have the following specification:
In the USA and Canada
UL approved and CSA certified flexible 3-conductor power cord having
individual conductor wire of gauge #18 AWG and length not exceeding 4.5 m
(15 ft). The power cord terminations should be NEMA Type 5-15P (3-prong,
one prong for earthing) at one end and an IEC appliance inlet coupler at the
other end.
Any of the following types of power cords are acceptable:
G, S, SE, SJ, SJE, SJO, SJOO, SJT, SJTOO, SO, SOO, SP-3, SPE-3, SPT-3,
ST, STO, STOO, SV, SVE, SVO, SVT, SVTO, SVTOO, W.
In all other countries
Flexible 3-conductor power cord approved by the cognizant safety
organization of the country. The power cord must be Type HAR (harmonized),
with individual conductor wire having cross-sectional area 0.75 sq. mm. The
power cord terminations should be a suitably rated earthing-type plug at one
end and an IEC appliance inlet coupler at the other end. Both of the power
cord terminations must carry the certification label of the cognizant safety
organization of the country.
11U = 1¾ inch or 44.45 mm
URL: http://www.mrv.com 6