WARNING--ACTIVATION OF THIS ALARM INDICATES THE PRESENCE OF DANGEROUS
LEVELS OF GASOLINE /PROPANE VAPORS OR HEAT THAT COULD CAUSE AN EXPLOSION OR
FIRE. IT ALSO INDICATES THE PRESENCE OF RISING WATER IN YOUR BOAT.
TAKE THESE STEPS IF AN ALARM SOUNDS:
If the Fume Alarm Sounds:
Turn off all electrical equipment, generators; extinguish all open flames (oven, cook top, smoking materials, etc.).
Turn off the engine(s) if safe navigation conditions exist. Open the engine compartment, ports, hatches and doors and
ventilate the area. If you are ashore, evacuate the boat. Do not return until the area is ventilated and the detector has
returned to normal standby condition. Proceed with caution and locate and repair the cause of the leak. Seek a
qualified technician if necessary. Do not start or use the boat until all the necessary repairs are made.
If the Heat Alarm Sounds:
Check the engine(s) temperature. If there is smoke coming from the engine room/compartment and there is no automatic
fire suppression system in the engine room/compartment; put on your life jackets, radio the Coast Guard and leave the boat
if necessary. Get as far away from the boat as possible. DO NOT OPEN THE ENGINE ROOM DOOR OR HATCH.
If the Water AlarmSounds:
Put on your life jackets. Check the bilge pump water outlet to determine that the pump is running. If it is not running,
manually start bilge pump. Open the hatch or compartment and try to determine the cause of the water leak. If more water
is entering the boat then the pump can handle, radio the Coast Guard for assistance.
SPECIFICATIONS
Power Supply - 12 VDC Operational Voltage - 7 to 15 VDC Power Draw - .200 amps @ 14 VDC
Operating Temp -220F - 1600F Fume Alarm Threshold - <20% LEL of Gasoline and Propane
Other gases detected but not listed; Alcohol, Acetone, Hydrogen and most other flammable gases.
Heat Sensor –Rate of Rise auto reset 1940F
LIMITED PRODUCTS WARRANTY
MTI INDUSTRIES, INC. warrants to the original retail purchaser that its products will be free from defects of material or workmanship
for a period of Two (2) years from the date of retail purchase. If proven to have been defective in original materials or workmanship and
returned, delivery costs prepaid, MTI INDUSTRIES, INC. will replace this product free of charge.
LIMITS OF WARRANTY
Replacement is your exclusive remedy under this limited warranty or any other warranty (including any implied warranty of merchantability
for a particular purpose). Any and all implied warranties or merchantability or fitness for a particular purpose shall be limited to the
warranty period from the original date of retail purchase. MTI INDUSTRIES, INC., its dealers and distributors shall in no case be
responsible or in any way liable for any incidental or consequential damages for any reason. Some states do not allow the limitation or
exclusion of incidental or consequential damages, or allow limitations on how long an implied warranty lasts, so the above limitations may
not apply to you. This warranty gives you specific rights, and you may also have other rights, which may vary, from state to state.
PRODUCT NOT WARRANTED
NOTE- There are no user serviceable parts inside the case. Opening any SAFE-T-ALERTTM product for any reason voids the
warranty. This warranty does not cover damage or failure resulting from acts of God, abuse, misuse, neglect, or faulty installation.
WARRANTY RETURN PROCEDURES
It is MTI’s experience that an alarm is sounding for a reason. Call, ask your dealer to call, or e-mail our Customer Service Department (as
listed below) to trouble shoot the situation.
Customer Service Phone No. - 800-383-0269
Fax No. 847-546-9007
Web Site: www.mtiindustries.com If Customer Service determines that the unit is defective, a Replacement Authorization (RA) number will
be issued. No product will be accepted for service or replacement without first obtaining a RA number.
©2018 MTI Industries, Inc. ALL RIGHTS RESERVED MTI FORM NO: SA10-297-2
MARINE TECHNOLOGIES, INC.
SAFE-T-ALERT™ SA-10XL MARINE
GASOLINE/PROPANE, BILGE WATER AND FIRE DETECTORS
USER’S MANUAL
IMPORTANT
PLEASE READ CAREFULLY AND SAVE
ATTENTION: This user’s manual contains important detector installation, operation, trouble shooting
and warranty information. Read, follow, and keep this manual for future reference.
NOTE: If you install or purchase this detector for another person, give this manual to that person.
WARNING
LIMITATIONS OF COMBINATION DETECTORS
Detectors will not work without power. Some reasons your detector may not have power include an open circuit
breaker, a blown or missing fuse, a broken wire or improper wire crimp connection.
This detector may not be heard. The detector’s loudness is designed to meet or exceed regulatory standards;
however, the alarm may not be heard if units are remotely located. Individuals who are hard-of-hearing, have
consumed alcoholic beverages, have taken prescription, non-prescription or illegal drugs may not hear the alarm. If
your boat has any sleeping areas, consider installing additional detectors in that area.
This detector will only indicate the presence of gasoline fumes or heat at the sensor. The sensor cannot monitor a
compartment that is separated by a bulkhead. Gasoline fumes and heat may be present in other areas. MTI
recommends that sensors be installed in ALL compartments containing fuel tanks and/or engine(s) and compartments
where gasoline or propane fumes or heat may accumulate.
INSTALLATION INSTRUCTIONS
Assemble the following supplies: An 3/8” (9.525 mm) electric drill, ¼” (6.35 mm) and 7/64” (2.77812 mm)
drill bits, 2-1/8” (53.975mm) hole saw, electric jigsaw, screwdrivers (Phillips and slotted), stainless-steel pan
head screws, washers bolts, nuts, locking nuts, silicone sealant, 18-gauge wire, 14-gauge wire, inline fuse holder,
1A fuse, wire stripper, crimping tool, crimp connectors, adhesive-lined heat shrink tubing, split loom wire wrap,
heat gun, wire supports, and cable ties.
When you have the supplies on hand, take the following steps:
Installing the Control Panel
1. Locate the control panel at the helm where it can be easily seen and heard. Check first to be sure that there is
at least 3 inches (76.2 mm) of clearance behind the location to allow for mounting and wiring. Drill a 2 1/8