MULTIQUIP MQ600TD80 Guide

OPERATION AND PARTS MANUAL
Revision #8 (11/13/09)
THIS MANUAL MUST ACCOMPANY
THE EQUIPMENT AT ALLTIMES.
MODEL MQ600TD80
TRASH PUMP
(DIESEL ENGINE)

PAGE 2 —MQ600TD80 TRASH PUMP — OPERATION AND PARTS MANUAL — REV. #8 (11/13/09)
Diesel engine exhaust and some of
PROPOSITION 65 WARNING

MQ600TD80 TRASH PUMP — OPERATION AND PARTS MANUAL — REV. #8 (11/13/09) — PAGE 3
NOTES

PAGE 4 —MQ600TD80 TRASH PUMP — OPERATION AND PARTS MANUAL — REV. #8 (11/13/09)
TABLE OF CONTENTS
Specification and part number
are subject to change without
notice.
Pump Impeller, Cleanout Discharge Assy. ......... 46-47
Pump Suction Side Assy. ................................... 48-49
Intermediate Plate Assy. .................................... 50-51
Trailer Assy. ........................................................ 52-53
Battery/Fuel Assy ............................................... 54-55
Hydraulic Brake Line Assy. ................................ 56-57
Control Box Assy. (Deutz F4L913) ..................... 58-59
Control Box Assy. (Deutz F4L914) ..................... 60-61
Documentation Box ............................................ 62-63
Terms and Conditions Of Sale — Parts .................. 64
Multiquip MQ600TD80 —
Diesel Powered Trash Pump
Proposition 65 Warning ............................................. 2
Table Of Contents ..................................................... 4
Training Checklist ...................................................... 5
Daily Pre-Operation Checklist ................................... 6
Parts Ordering Procedures ....................................... 7
Safety Message Alert Symbols .............................. 8-9
Rules For Safe Operation .................................. 10-11
Operation and Safety Decals ............................. 12-13
Specifications .......................................................... 14
Pump Dimensions ................................................... 16
Trailer Dimensions .................................................. 17
Components....................................................... 18-19
General Information ................................................ 20
Application ............................................................... 21
Pre-Setup (Pump) ................................................... 22
Initial Start-Up (Engine) ..................................... 23-25
Towing Guidelines ................................................... 26
Trailer Safety Guidelines .................................... 27-30
Trailer Wiring Diagram............................................. 31
Maintenance ...................................................... 32-35
Preparation For Long Term Storage ....................... 36
Troubleshooting (Pump).......................................... 37
Troubleshooting (Engine) ................................... 38-39
Trailer Brakes (Hydraulic) ....................................... 40
Explanation Of Codes In Remarks Column ............ 42
Suggested Spare Parts ........................................... 43
Name Plate And Decals ..................................... 44-45
NOTE

MQ600TD80 TRASH PUMP — OPERATION AND PARTS MANUAL — REV. #8 (11/13/09) — PAGE 5
PARTS ORDERING PROCEDURES
www.multiquip.com
Ordering parts has never been easier!
Choose from three easy options:
WE ACCEPT ALL MAJOR CREDIT CARDS!
When ordering parts, please supply:
RDealer Account Number
RDealer Name and Address
RShipping Address (if different than billing address)
RReturn Fax Number
RApplicable Model Number
RQuantity, Part Number and Description of Each Part
RSpecify Preferred Method of Shipment:
UPS/Fed ExDHL
NPriority OneTr u c k
NGround
NNext Day
NSecond/Third Day
If you have an MQ Account, to obtain a Username
and Password, E-mail us at: parts@multiquip.
com.
To obtain an MQ Account, contact you
r
District Sales Manager for more information.
Order via Internet (Dealers Only):
Order parts on-line using Multiquip’s SmartEquip website!
NView Parts Diagrams
NOrder Parts
NPrint Specification Information
Note: Discounts Are Subject To Change
Goto www.multiquip.com and click on
Order Parts to log in and save!
Use the internet and qualify for a 5% Discount
on Standard orders for all orders which include
complete part numbers.*
Order via Fax (Dealers Only):
All customers are welcome to order parts via Fax.
Domestic (US) Customers dial:
1-800-6-PARTS-7 (800-672-7877)
Fax your order in and qualify for a 2% Discount
on Standard orders for all orders which include
complete part numbers.*
Order via Phone: Domestic (US) Dealers Call:
1-800-427-1244
Best Deal!
International Customers should contact
their local Multiquip Representatives for
Parts Ordering information.
Non-Dealer Customers:
Contact your local Multiquip Dealer for
parts or call 800-427-1244 for help in
locating a dealer near you.
Note: Discounts Are Subject To Change
Effective:
January 1st, 2006
NOTICE
All orders are treated as Standard Orders and will
ship the same day if received prior to 3PM PST.

PAGE 6 —MQ600TD80 TRASH PUMP — OPERATION AND PARTS MANUAL — REV. #8 (11/13/09)
TRAINING CHECKLIST
This checklist will lists some of the minimum requirements for machine maintenance and operation. Please feel free to detach it and
make copies. Use this checklist whenever a new operator is to be trained or it can be used as a review for more experienced
operator’s.
Operator _________________________________________ Trainee __________________________________________
COMMENTS:
TRAINING CHECKLIST
TSILKCEHCGNINIART
.ON NOITPIRCSED ?KO ETAD
1 .yletelpmoclaunaMs’rotarepOdaeR
2liodnaenignefognikcehc,stnenopmocfonoitacol,tuoyalenihcaM
.slevel
3 .erudecorpgnileufer,metsysleuF
4 .erudecorpgnimirppmuP
5 .serudecorppotsycnegremE
6 .erudecorppu-tratsenignE
7 )liabgnitfil(enihcamfognitfiL
8 ).ctesesu,tfil(snoitacilppapmuP
9 .tnemecalpreniartsnoitcuS
01 .snoitcennocesoH
11 .tnemecalppmuP
21 .senilediugytefasreliarT
31 .senilediuggnihtolcevitcetorP
41 .erudecorptsetmuucaV
51 .egarotsdnatropsnartenihcaM
61 .erudecorpytivacpmuptuonaelC

MQ600TD80 TRASH PUMP — OPERATION AND PARTS MANUAL — REV. #8 (11/13/09) — PAGE 7
DAILY PRE-OPERATION CHECKLIST
COMMENTS:
DAILY PRE-OPERATION CHECKLIST
SILKCEHCNOITAREPO-ERPYLIAD T
1 .levellioenignekcehC
2 .)leufnaelcrofdna(levelleufkcehC
3 .wolfriagniloocdnasnifgniloockcehC
4 .renaelcriaenignekcehC
5 .snoitcennocelbacdnayrettabenignekcehC
6 .)etulovdnarellepmi(roiretnipmupkcehC
7 .laespmupkcehC
8 .skcarcrofgnisacpmupkcehC
9 .ssenthgitrofstungulleehwreliartkcehC
01 .sgniraebleehwreliartkcehC
11 .llabdnahctihreliartkcehC
21 .)dnatskcaj(erawdrahdnasgnirpsreliartkcehC
31 .erusserperitreliartkcehC
41 .sthgilreliartkcehC

PAGE 8 —MQ600TD80 TRASH PUMP — OPERATION AND PARTS MANUAL — REV. #8 (11/13/09)
MQ600TD80 — SAFETY MESSAGE ALERT SYMBOLS
Safety precautions should be followed at all times when
operating this equipment. Failure to read and understand the
Safety Messages and Operating Instructions could result in
injury to yourself and others.
FOR YOUR SAFETY AND THE SAFETY OF OTHERS!
This Owner's Manual has been developed to provide
complete instructions for the safe and efficient operation
of the Multiquip Model
MQ600TD80 Trash Pump
. Refer
to the engine manufacturers instructions for data relative
to its safe operations.
Before using this centrifugal trash pump, ensure
that the operating individual has read and
understands all instructions in this manual.
NOTE
SAFETY MESSAGE ALERT SYMBOLS
The three (3) Safety Messages shown below will inform you
about potential hazards that could injure you or others. The
Safety Messages specifically address the level of exposure to
the operator, and are preceded by one of three words: DANGER,
WARNING, or CAUTION.
HAZARD SYMBOLS
Engine exhaust gases contain poisonous
carbon monoxide. This gas is colorless and
odorless, and can cause death if inhaled.
NEVER operate this equipment in a confined
area or enclosed structure that does not
provide ample free flow air.
Potential hazards associated with
MQ600TD80 Trash Pump
operation will be referenced with Hazard Symbols which appear
throughout this manual, and will be referenced in conjunction
with Safety Message Alert Symbols.
DIESEL fuel is extremely flammable, and its
vapors can cause an explosion if ignited. DO
NOT start the engine near spilled fuel or
combustible fluids. DO NOT fill the fuel tank
while the engine is running or hot. DO NOT
overfill tank, since spilled fuel could ignite if it
comes into contact with hot engine parts or
sparks from the ignition system. Store fuel in
approved containers, in well-ventilated areas
and away from sparks and flames. NEVER
use fuel as a cleaning agent.
Explosive Fuel
Lethal Exhaust Gases
Burn Hazards
Engine components can generate extreme heat.
To prevent burns, DO NOT touch these areas
while the engine is running or immediately after
operations. Never operate the engine with heat
shields or heat guards removed.
Rotating Parts
NEVER operate equipment with covers, or
guards removed. Keep fingers, hands, hair and
clothing away from all moving parts to prevent
injury.
You WILL be
KILLED
or
SERIOUSLY
injured if you DO
NOT follow directions.
You CAN be
KILLED
or
SERIOUSLY
injured if you DO
NOT follow directions.
You CAN be
INJURED
if you DO NOT follow directions.
CAUTION
DANGERDANGER
DANGERDANGER
DANGER
WARNINGWARNING
WARNINGWARNING
WARNING
CAUTIONCAUTION
CAUTIONCAUTION
CAUTION

MQ600TD80 TRASH PUMP — OPERATION AND PARTS MANUAL — REV. #8 (11/13/09) — PAGE 9
Accidental Starting
MQ600TD80 — SAFETY MESSAGE ALERT SYMBOLS
ALWAYS place the engine ON/OFF switch in
the OFF position, and remove the ignition key
when the machine is not in use.
Respiratory Hazard
ALWAYS wear approved respiratory
protection.
Equipment Damage Messages
Other important messages are provided throughout this manual
to help prevent damage to your trash pump, other property, or
the surrounding environment.
This trash pump, other property, or
the surrounding environment could
be damaged if you do not follow
instructions.
ALWAYS wear approved eye and hearing
protection.
Sight and Hearing hazard
NOTE

PAGE 10 —MQ600TD80 TRASH PUMP — OPERATION AND PARTS MANUAL — REV. #8 (11/13/09)
RULES FOR SAFE OPERATION
The following safety guidelines should always be used when
operating the
MQ600TD80Trash Pump
:
GENERAL SAFETY
■
DO NOT operate or service this
equipment before reading this entire
manual.
■
This equipment should not be operated by persons under
18 years of age.
■
NEVER operate this equipment without proper protective
clothing, shatterproof glasses, steel-toed boots and other
protective devices required by the job.
■
High Temperatures – Allow the
engine to cool before adding fuel or
performing service and maintenance
functions. Contact with
hot!
components can cause serious
burns.
■
The air-cooled diesel engine
of this pump requires an
adequate free flow of cooling
air.
NEVER
operate the
pump in any enclosed or
narrow area where free flow
of the air is restricted. If the
air flow is restricted it will
cause serious damage to the pump or engine and may
cause injury to people. Remember the mixer's engine gives
off
DEADLY
carbon monoxide gas.
■
ALWAYS refuel in a well-ventilated area, away from
sparks and open flames.
■
ALWAYS use extreme caution when
working with flammable liquids. When
refueling, stop the engine and allow it to
cool. DO NOT
smoke
around or near the
machine. Fire or explosion could result
from fuel vapors, or if fuel is spilled on a
hot engine.
DANGERDANGER
DANGERDANGER
DANGER
Failure to follow instructions in this manual may lead to
serious injury or even death! This equipment is to be
operated by trained and qualified personnel only! This
equipment is for industrial use only.
■
NEVER operate this equipment under the influence of
drugs
or
alcohol
.
Read this manual!
■
NEVER touch the hot exhaust
manifold, muffler or cylinder. Allow
these parts to cool before servicing
engine or mixer.
■
ALWAYS wear proper respiratory (mask),
hearing and eye protection equipment when
operating the mixer.
■
NEVER place hands inside the drum while the blades are
rotating.
■
Whenever necessary, replace nameplate, operation and
safety decals when they become difficult read.
■
Manufacture does not assume responsibility for any
accident due to equipment modifications.
■
NEVER use accessories or attachments, which are not
recommended by Multiquip for this equipment. Damage
to the equipment and/or injury to user may result.
■
NEVER operate this equipment when not
feeling well due to fatigue, llness or taking
medicine.
■
Topping-off to filler port is dangerous, as it tends to spill
fuel.
■
Stop the engine when leaving the pump unattended.
■
Block the unit when leaving or when using on a slope.
■
Maintain this equipment in a safe operating condition at
■
NEVER use accessories or attachments, which are not
recommended by Multiquip for this equipment. Damage to
the equipment and/or injury to user may result. all times.
■
NEVER operate the pump in an
explosive atmosphere or near
combustible materials. An explosion or
fire could result causing severe
bodily
harm or even death.

MQ600TD80 TRASH PUMP — OPERATION AND PARTS MANUAL — REV. #8 (11/13/09) — PAGE 11
Maintenance Safety
■
NEVER lubricate components or attempt service on a running
machine.
■
ALWAYS allow the machine a proper amount of time to cool
before servicing.
■
Keep the machinery in proper running condition.
■
Fix damage to the machine immediately and always replace
broken parts.
■
Dispose of hazardous waste properly. Examples of potentially
hazardous waste are used motor oil, fuel and fuel filters.
■
DO NOT use food or plastic containers to dispose of
hazardous waste.
■
DO NOT pour waste, oil or fuel directly onto the ground,
down a drain or into any water source.
RULES FOR SAFE OPERATION
■
NEVER pump volatile, flammable or low flash point fluids.
These fluids could ignite or explode.
■
NEVER pump corrosive chemicals or water containing toxic
substances. These fluids could create serious health and
environmental hazards. Contact local authorities for
assistance.
■
NEVER open the priming plug when pump is hot. Hot water
inside could be pressurized much like the radiator of an
automobile. Allow pump to cool to the touch before loosening
plug.
■
NEVER open the pump housing during operation or start the
pump with the cover off. The rotating impeller inside the pump
can cut or sever objects caught in it.
■
NEVER block or restrict flow from discharge hose. Remove
kinks from discharge line before starting pump. Operation
with a blocked discharge line can cause water inside pump to
overheat.
■
NEVER Run engine without air cleaner. Severe engine
damage may occur.
■
ALWAYS read, understand, and follow procedures in
Operator’s Manual before attempting to operate equipment.
■
ALWAYS be sure the operator is familiar with proper safety
precautions and operations techniques before using pump.
■
ALWAYS store equipment properly when it is not being used.
Equipment should be stored in a clean, dry location out of the
reach of children.
■
Refer to the
Engine Owner's Manual
for engine technical
questions or information.
■
ALWAYS fill the pump casing with water before starting the
engine. Failure to maintain water inside the pump housing
will cause severe damage to the pump.
■
In winter drain water from pump housing to prevent freezing.
■
ALWAYS make sure pump is correctly secured to the trailer.
Check all supports attaching the pump to the trailer and make
sure they are tight.
■
ALWAYS make sure that the pump's trailer is placed on solid
level ground so that it cannot slide or shift around, endangering
workers. Place blocks under the trailer's bumper to make it
level (prevents tipping), and use a chocked block underneath
the wheels to prevents rolling. Also keep the immediate area
free of bystanders.
■
HighTemperatures – Allow the engine to cool before adding
fuel or performing service and maintenance functions. Contact
with
hot
components can cause serious burns.
Weight does not include trailer
or other accessories.
NOTE
■
In emergencies
always
know the location of the
nearest phone or
keep a phone on the job site
.
Also know the phone numbers of the nearest
ambulance
,
doctor
and
fire department
. This
information will be invaluable in the case of an
emergency.
Lifting
■
The Pump has an operating weight of 2,800 lbs. (1,270 KG).
Use lifting equipment with a rated capacity of at least 14,000
lbs (6,350 KG). Remove suction & discharge hoses/pipes
before lifting.
EMERGENCIES
■
ALWAYS know the location of the nearest
fire
extinguisher
and first aid kit.

PAGE 12 —MQ600TD80 TRASH PUMP — OPERATION AND PARTS MANUAL — REV. #8 (11/13/09)
OPERATION AND SAFETY DECALS
Machine Safety Decals
The MQ600TD80 Centrifugal Trash pump is equipped with a number of safety decals.These decals are provided for operator safety
and maintenance information.The illustration below and on the next page shows these decals as they appear on the machine.
Should any of these decals become unreadable, replacements can be obtained from your dealer.

MQ600TD80 TRASH PUMP — OPERATION AND PARTS MANUAL — REV. #8 (11/13/09) — PAGE 13
OPERATION AND SAFETY DECALS

PAGE 14 —MQ600TD80 TRASH PUMP — OPERATION AND PARTS MANUAL — REV. #8 (11/13/09)
MQ600TD80 — SPECIFICATIONS
SNOITACIFICEPSPMUP.2ELBAT
gnipmuPmumixaM yticapaC )mpl550,6(mpg0061
*tfiLnoitcuSmumixaM)sretem6.7(.TF52
dae
HlatoTmumixaM)sretem7.54(.TF051
erusserPmumixaMisp9.46
sdiloSmumixaM)mm67(.ni3
dnanoitcuS
retemaiDegrahcsiD )
mm251(.ni6
)HxWxL(snoisnemiD
detnuoMreliarT
.ni94x93x08
).mc421x99x302(
)leuFoN(thgieW).gk883,1(.sbl060,3
.sedutitlarehgihtasseleblliwtfilnoitcusmumixaM.levelaestagnitarepopmupnodesaB*
SOUND MEASUREMENTS
The required sound specifications, per Appendix 1, paragraph 1.7.4.f of the EC-Machine Regulations,
are defined as follows:
The sound pressure level at the operator's location (L) = 87 dB (A)
The sound power level (L) = 97 dB (A)
These sound values are determine according to ISO 3744 for the sound power level (L) and ISO
6081 for the sound pressure level (L) at the operator's location.
The sound measurements were obtained with the unit operation on pavement at nominal speed.
SNOITACIFICEPSENIGNE.1ELBAT
ekaMenignEztueD
ledoMenignE319l4F/319L4F
epyTenignEleseiDekortS-4delooCriA
sredn
ilyCfOrebmuN4
(ekortS/eroB)319L4Fmm521/201
(ekortS/eroB)419L4Fmm231/201
(PHenignEsuounitnoC)319L4F*MPR009,1@PH0
.06
(PHenignEsuounitnoC)419L4F*MPR009,1@PH3.86
dohteMnoitsubmoCnoitcejnIleuFtceriD
edarGliO02egap,2elbaTeeS
y
ticapaCliOsretil5.2/lag5.9
epyTleuFleseiD
yticapaCknaTleuFsretil0.15/lag04
dohteMgnitratStratScirtcelE
PH08=MPR005,2@)tnettimretni(PHenignEmumixaM*

MQ600TD80 TRASH PUMP — OPERATION AND PARTS MANUAL — REV. #8 (11/13/09) — PAGE 15
NOTES

PAGE 16 —MQ600TD80 TRASH PUMP — OPERATION AND PARTS MANUAL — REV. #8 (11/13/09)
MQ600TD80 — PUMP DIMENSIONS
SNOISNEMIDPMUP.3ELBAT
ECNEREFER
RETTEL NOITPIRCSED SNOISNEMID
)MM(SEHCNI
A
09FOPOTMORFDERUSAEM
GNITNUOMOTWOBL
EEERGED
.)THGIEH(TEEF
SEHCNI5.54
)MM651,1(
B
FOPITMORFDERUSAEM
PITOTGNISUOHETAIDEMRETNI
.)HTPED(ELDNAHGNIKCO
LFO
SEHCNI23
)MM318(
C-EDISPMUPMORFDERUSAEM
.)HTDIW(LLAW-EDISOTLLAW
SEHCNI5.42
)MM226(
Figure 1. Pump Dimensions

MQ600TD80 TRASH PUMP — OPERATION AND PARTS MANUAL — REV. #8 (11/13/09) — PAGE 17
MQ600TD80 —TRAILER DIMENSIONS
SNOISNEMIDRELIART.4ELBAT
ECNEREFER
RETTEL NOITPIRCSED SNOISNEMID
)MM(SEHCNI
A
FOPOTMORFDERUSAEM
FOMOTTOBOTELA
BGNITFIL
.)THGIEH(ERIT
SEHCNI5.56
)MM466,1(
B
FOPITMORFDERUSAEM
FORAEROTRELPUOCRELIART
.)HTGNEL(EMARFRELIART
SEHCNI511
)MM129,2(
COTREDNEFMORFDERUSAEM
.)HTDIW(REDNEF
SEHCNI46
)MM626,1(
Figure 2. Trailer Dimensions

PAGE 18 —MQ600TD80 TRASH PUMP — OPERATION AND PARTS MANUAL — REV. #8 (11/13/09)
Figure 3. Pump Components
MQ600TD80 — COMPONENTS

MQ600TD80 TRASH PUMP — OPERATION AND PARTS MANUAL — REV. #8 (11/13/09) — PAGE 19
MQ600TD80 — COMPONENTS
Figure 3 shows the location of the components and basic
components for the MQ600TD80 trash pump, The function
of each component or control is described below:
1. Pump End Jack Stand – Use this jack stand to level
and support the trash pump.
2. Pump Discharge Port – Discharges water and debris
from the pump.
3. Bearing Sight Glass – Use this sight glass to determine
if oil is present. Oil must be
visible
within the sight
glass at all times.
4. Mechanical Seal Sight Glass – Use this sight glass to
determine if oil is present. Oil must be
visible
within the
sight glass at all times.
5. Battery – +12 VDC battery compartment.
6. Control Box Panel – Monitors engine functions and
will shut down the engine for low oil pressure, high
coolant temperature, alternator charge and V-belt failure.
7. Muffler/Guard – DO NOT touch the muffler when
engine is running. The muffler can become extremely
hot, causing severe burns. NEVER run the pump with
the muffler guard removed.
8. Lifting Bail – When lifting of the trash pump by crane is
required, use this lifting bail. Note: this lifting bail is
balanced for a fully configured trash pump; removal of
any trash pump components will un-balance the lifting
bail.
9. Oil Bath Cleaner – Prevents dirt and any foreign debris
from entering the engine. Service this unit as
recommended in the maintenance section of this
manual.
10. Tow End Jack Stand – Use this jack stand to level and
support the trash pump.
11. Brake Coupler – This device will activate the hydraulic
braking system of the pump's trailer in the event the
pump's trailer becomes detached from the towing
vehicle.
12. Tow Hitch Coupler – Requires a 2-5/16 ball hitch or a
3-inch pintle.
13. Safety Chain – Always attach safety chain to the towing
vehicle. NEVER! tow the trash pump with the safety chain
unattached.
14. Documentation Box – Contains documentation for the
pump and engine.
15. Engine Throttle Lever – Controls the speed of the
engine. For load conditions (pumping water) ALWAYS
run the engine at
full speed
.
16. Oil Filler – Fill as recommended in the maintenance
section of this manual.
17. Engine (Diesel) – This pump uses a Deutz FL913 air-
cooled, 4-stroke diesel engine. See the Deutz Operation
manual supplied with the trash pump for additional
engine information.
18. Fuel Gauge/Filler Port – Read top of gauge to
determine fuel level. Re-fuel using only recommended
types of diesel fuels (see Deutz Operation Manual). DO
NOT top off fuel, wipe up any spilled fuel immediately.
19. Chock Blocks – Place these blocks (not included as
part of the trash pump package) under each trailer wheel
to prevent rolling.
20. Trailer Lights – Before towing trash pump, make sure
that both trailer lights are functioning correctly. NEVER
tow the trash pump if these lights are not working.
21. Pump Shaft Guards – To prevent injury to hands and
fingers these two guard covers (one each side of pump
housing) are to remain in place at all times when the
pump is in use.
22. Dipstick – Read this gauge to determine the level oil in
the engine crankcase. Fill with only recommended type
oil as referenced in the maintenance section of this
manual.
23. Fuel Filters – This pump design incorporates the use
of four fuel filters, maintain these filters as recommended
in the maintenance section of this manual.
24. Fuel Water Separator – Removes water from the fuel
system. Inspect and clean as recommended in the
maintenance section of this manual.
25. SupportTubes – These tubes protect the fuel tank from
being damaged when the pump frame is lying on a flat
surface.
26. Fuel Tank/Drain Plug – The fuel tank is part of the
frame (sides). It holds 40 gallons (51 liters) of diesel
fuel. Remove this drain plug to drain the fuel tank.
27. Pump Intake Port – Intakes water and debris from the
source.
28. Fill Cap – Remove this cap to prime the pump with water.
29. Clean-Out Cover – Remove this cover to clean and
remove foreign debris from the trash pump.
30. Accessories – Hoses, strainers and clamps are the
required accessory components for normal operation
of this trash pump.
Contact
your nearest Multiquip
dealer for information on the components.

PAGE 20 —MQ600TD80 TRASH PUMP — OPERATION AND PARTS MANUAL — REV. #8 (11/13/09)
MQ600TD80 — GENERAL INFORMATION
The MQ600TD80 Trash Pump is a self-priming centrifugal trash
pump powered by a 80 horsepower air-cooled four stroke Deutz
diesel engine. Both the intake (suction) and discharge ports on
the MQ600TD80 incorporate a 6-inch diameter opening, which
allows the pump to charge as needed at a rate of approximately
1,600 gpm or 6,055 lpm.
This is a self-priming pump design and the pump casing must
be filled with water before starting operation.The engine drives
a rotating disc with two ( or more vanes) called an impeller that
creates an area of low pressure inside the pump. Priming is
accomplished when all air is purged from the pump and suction
line allowing water to flow continuously into the pump.
Trash Pump
Trash pumps derive their name from their ability to handle a
greater amount of debris and solids than standard centrifugal
pumps.These pumps generally handle solids up to 1/2 the size
of the discharge opening making them less likely to clog. Also
trash pumps are capable of handling water with 25% solids by
weight.
The advantage of using a trash pump is that it can be quickly
and easily disassembled in the field to remove debris in the
event the pump becomes clogged.
Suction Lift
This pump has a maximum suction lifts up to 25 feet at sea level.
At elevations above sea level suction lift decreases at a
rate of 1 foot of suction lift per 1,000 feet of elevation.
Therefore, when this pump is being used at an elevation of 5,000
feet the maximum suction lift is reduced to 20 feet. It is
recommended that the pump be located as close to the source
as possible to minimize suction lift.
Pump Support
The pump should always be placed on solid stationary ground
in a level position.To prevent the trailer from tipping, place blocks
under the trailer's bumper. In addition, place chock blocks behind
each wheel to prevent the trailer from rolling.
NEVER place the pump on
soft soil
. The suction hose or pipe
connection should always be checked for tightness and leaks. A
small suction leak in the hose or fittings could prevent the pump
from priming.
.
Elevation
Elevations over 3,000 feet will effect the performance of the
pump. Due to less atmospheric pressure at higher altitudes,
pumps DO NOT have the priming ability that they have at sea
level.
A general rule of thumb is that for every 1,000 feet of elevation
above sea level a pump will lose one foot of priming ability.
For example, in Flagstaff, Arizona where the elevation is
approximately 7,000 feet, the pump would have a suction lift of
only 18 feet rather than the 25 feet at sea level.
Pump Clean-out
The clean-out cover on the MQ600TD80 has been design for
easy removal that allows for easy access to the wear plate and
impeller for cleaning and servicing.
In order to comply with local laws regarding spark arresters,
consult the engine distributor or the local Health and Safety
Administrator.
Mechanical Seal Lubrication
The pump uses a oil lubricated mechanical seal to prevent water
from seeping into the engine. The oil in the seal chamber
lubricates the seal and prevents it from overheating. Never
operate the pump without water in the casing as this may cause
the seal to fail. ( See section on seal maintenance).
Engine Safety
Internal combustion engines present special hazards during
operation and fueling! Failure to follow the safety guidelines
described in the Rules for Safe Operation section of this manual
and the Deutz Engine Operator's Manual could result in severe
injury or death.
Accessories
Multiquip offers a complete line of fittings, hoses, and clamps to
properly connect the pump to match various job conditions. Refer
to the part list in section 2 of this manual for a complete list of
accessories
Table of contents
Other MULTIQUIP Trash Compactor manuals
Popular Trash Compactor manuals by other brands

Electrolux
Electrolux EI15TC65HS - Undercounter Trash Compactor Technical & service manual

Wesco
Wesco Klassikline DT quick start guide

Whirlpool
Whirlpool GX900QPPB Use and care guide

Maytag
Maytag MTUC7000AW Product dimensions

Jenn-Air
Jenn-Air W10242571C Use and care guide

InSinkErator
InSinkErator Badger 700 manual