Pen depot calibration –Adjusting height
Switch on plotter and put pens in all four pen stations. Switch off plotter.
Hold down arrow keys ▲▼and press ON. Arm/pen will move to first
cartridge of pen depot.
Now height of cartridge can be adjusted with arrow keys ▲▼. Yellow
ring of plot pen must exactly fit in pen holder of pen unit.
If position is correct press PEN/UP DOWN key. Pen will move in
cartridge. Press PEN/UP DOWN to move pen back from cartridge.
Move pen to other cartridges by pressing arrow keys ◄or ►. Adjust as
described.
Press STOP to save settings.
Pen depot calibration –Adjusting X/Y position
Switch from height to X/Y adjusting by pressing the CLEAR BUFFER
key.
There must be no pen in the pen depot's cartridges. But a pen is placed
manually in the pen holder.
Press PENSTATION OPEN/CLOSE to lower the penstation.
Press PEN UP/DOWN and the pen will move in the center of the
cartridge.
If the pen is not centered correctly use the ◄►arrow keys to adjust the
correct position.
Press PENSTATION OPEN/CLOSE to check if the pen will be correctly
placed in the middle of the cartridge.
Press STOP to save settings and the plotter will be in operational mode.