MYLAPS X2 Decoder - Quick start guide
Installing the MYLAPS X2 Decoder
The detection loop: Connect here the coax cable coming from the
detection loop to the MYLAPS X2 decoder.
The auxiliary port: This port can be used to connect a photocell,
external start pulse or a sync pulse. For more information on how
to connect these devices, see appendix D of the MYLAPS X2 decoder
manual.
The GPS antenna: Connect the GPS antenna cable and place the
antenna where it has a clear view of the sky overhead to be able to
make connections to satellites in order to synchronize to the time of
day very accurately.
CAN connector: for future use
The network: Use a UTP cable to connect the MYLAPS X2 Decoder to the
MYLAPS X2 Server on the red port of the MYLAPS X2 Decoder. The LEDs
on the connector will show if a physical network connection is available.
Power: Connect the supplied VDC adapter to the decoder and mains.
It is recommended to connect the VDC adapter to mains through
an Uninterruptable Power Supply (UPS) to avoid any interruption of
power supply to the decoder.
Technical Specications of the MYLAPS X2 Decoder
Dimensions 220x180x60mm / 8.7x7x2.4inch•
Weight 1.5kg / 3.3lb•
Clock Stability 0.5PPM•
GPSReceiver quickx,-160dB,15nS•
GPS antenna connection SMA, active•
Timing Resolution 0,001s•
Loopconnection 1xBNC,max.20mloop•
Operatingtemperaturerange -20to50°C/-4to122°F•
Humidity range 10% to 90% relative•
Operating voltage range 10 to 14.4VDC, Typical 12VDC•
Power consumption Appr. 5W•
NetworkInterface 10-100BT(RJ45)•
Auxiliaryconnector DB15,Female•
Can connection Future use•
Specicationsaresubjecttochangewithoutnotice
12