nabaidun PD30-WAE-F User manual

USER’S MANUAL
Product name:Dehumidifier
Model: PD30-WAE-F

1
SAFETY INFORMATION
1. Please read the operating instructions carefully
beforeusing your dehumidifier for the first time and
keepthem in a safe place.
2. Never immerse the appliance in water or other liquids.
3. Never operate the appliance if a cable or connectorhas
been damaged, after appliance malfunction or ifthe
appliance was dropped or is otherwise damaged.
4. Please ask a professional service agent to repair
theproduct. Improper repair may cause danger to users.
5. Never allow children to operate the appliance.
6. Disconnect the appliance from mains power
wheneverit is not in use, before relocating it, and
beforecleaning.
7. Operate the appliance only at the voltage specified
onthe rating label.
8. This appliance is designed for household purposes(not
commercial) only.
9. DO NOT COVER. Never cover or obstruct in any
waythe outlet at the top of the dehumidifier or the air
inletslots at the rear of the dehumidifier.
10. To prevent spillage, empty the water tank
beforerelocating the appliance.
11. Do not tip the appliance to any side as escaping
watercould damage the appliance. Only operate
theproduct at ground level on an even surface at
anupright position with adequate clearance from

2
fixturesand fittings to maximize airflow and
dehumidificationefficiency
12. This appliance is not intended for use by
persons(including children) with reduced physical,
sensory ormental capabilities, or lack of experience
andknowledge, unless they have been given
supervisionor instruction concerning use of the appliance
by aperson responsible for their safety. Children should
besupervised to ensure that they do not play with
theappliance.
13. When the supply cord is damaged, it must
bereplaced by the manufacturer, or a professionalservice
agent only.
14. Only operate this appliance with a minimum of
50cmclearance all around i.e. away from walls,
furnitureand overhanging objects such as curtains or a
shelf.
15. When the unit stops, you have to wait for 3minutes
before you can restart the unit to protectthe compressor
from damage
16. Air inlet filter must be cleaned regularly to
ensurecorrect operation and to avoid damage to
theappliance.

3
OPERATING INSTRUCTION
1.Control panel
2.Air outlet
3.Top panel
4.Handle
5. Front panel
6.Air inlet /back panel
7.Continuously drainage hole
8.Tank handle
9. Water tank

4
CONTROL PANEL DESCRIPTION
OPERATION INSTRUCTION
Starting the unit
Allow the unit to stand upright for 24hrs to let the compressor stabilizebefore
first use or when transported.
1. Plug in the dehumidifier.
2. Turn on the unit by push power button.
3. Push the set button to set the humidity rate at the desiredhumidity
level.

5
1. POWER
Press this key to set “POWER ON, POWER OFF”. The light
is on when” POWER ON”, and glimmer when” POWER OFF”.
2. FAN SPEED
Push this key to choose fan speed:
This fan light on is high fan speed;
This fan light on is low fan speed;
3. TIMER、
a. under running mode, push this keep to set “ TIMER OFF”.
b. Timer Choice:1,2,4,8hours,The desired time will be chosen when the
light is on.
c.The timer time (1H,2H,4H or 8H light) will be on if the TIMER OFF was
set.
4.HUMIDITY SET
Push this key to set the desired humidity rate. Optional humidity rate: 30%
→35%→40%→45%……→90%→30%as a cycle。The default humidity rate
is 40%”.
Even jump will be get by long time push this key for 1s.
The compressor will stop and just fan is running, if the room
humidity is 3% less than set humidity. The compressor only work
again when room humidity is 3% high than set humidity.
5,. SLEEPING MODE
Push this key to turn on the sleeping mode. Under this mode, the fan
speed default low speed without change; all other lights will be turn off only
push button light is on.
Under SLEEPING MODE, wake up the control panel by push any
button, then push again the “ sleeping model” button to leave this mode.
6.MODE KEY
Push this key to choose

6
AUTO MODE
LAUNDRY MODE
It will be chosen by the relative light is on.
7.WIFICONNECTION
1) Turn on the unit, the WIFI light will be sparkled for 30s, and the equipment
will receive the WIFI signal.After connection the WIFI light will be on.
2) Long time push WIFI button for 3s, WIFI will do re-connection. The
light will be on for successful connection, otherwise this light will be shiny.
8.CHILD LOCK +
Push this 2 key at the same for 3s, the CHILD LOCK will be on,
FUNCTION DESCRIPTION
Product auto shut off protection
The unit will be automatically shut off when running for 24 hours.
AUTO MODE
a. when ambient temperature<41°F, the compressor will stop running.
b.when 68°F≥ambient temperature ≥41°F,it will automatically set RH
60%.
c. when 80.6°F≥ambient temperature>68°F,it will automatically set 55%.
d. when ambient temperature>80.6°F,it will automatically set50%.
LAUNDRY MODE
The unit will keep on running when “ LAUNDRY MODE” is set, no matter
what ambient humidity rate.

7
TANK FULL
When the light is on, it means the tank is full then the unit will stop
working.
To empty the tank and press the power button, the unit will run again.
DEFROST
When this light is on, the unit is in defrosting. At this time, the
compressor is stop running, but the fan is working.
WARNING
1. When operating the dehumidifier, please do not set the humidity higher
than ambient humidity.
2. When tank full indicating light illuminates, please pour the water out of
the tank and put it back. Push the power button and the product will
resume working.
3. When the product shut down, please wait at least 3 minutes before
restarting the unit to prevent damaging the compressor.
4. The applicable operating temperature range for this unit is 5-32℃.
5. If the dehumidifier can’t start (the indicating light does not illuminate) or
the dehumidifier shut down unreasonably, please make sure whether
the plug is connected firmly to power supply. If the plug and power
supply are in normal condition, please wait for 10 minutes before restart
the unit (because it takes 10 minutes to reposition).If the unit still does

8
not start after 10 minutes, please ask your local distributor service
station to repair.
6. When the dehumidifier is operating, it’s a normal situation that the
working compressor may cause some heat and bring the ambient
temperature up.
7. When the product is defrosting, the related indicating light will
illuminate.
8. The unit shows the ambient humidity when it’s operating. If the ambient
humidity is higher than RH95%, the display shows “HI”; if the ambient
humidity is lower than RH35%, the display shows “LO”
DRAINAGE
The removed water can be stored by water tank, or do continuously
drainage by connect a PVC hose. (The hose is not included in the unit)
USAGE OF WATER TANK
After dehumidifying, the tank will be filled with water, under this case,
the unit will stop working with LED light,
Please pour out the water in time.
1. Take out the water tank as Fig 01and pour
out the water.
2. Put the water tank back.
3. Press power key to turn on the unit.

9
CONTINUOUS DRAINAGE
1. Before continuous draining water, please take out the water tank and
plug a draining tube to draining hole(See Fig 02.) Then put the water
tank back.
2. Draining tube should place lower than the draining hole to let water flow
out.
FILTER REMOVAL
1. Take out the water tank before remove the
filter.
2. Pulling out the filter with handles of filter.
3. Wash the filter with cool water(cooler than
40℃) every two weeks, and put filter back
after it air-dried naturally.
MAINTENANCE INSTRUCTION
Fig 02
Fig 01

10
1. The unit is not allowed to be placed on surface which is soft ornot flat
to avoid the unit cause noise, vibration, and water or electricity
leakage when operating.
2. Never insert any slim rod or hard stuff into the unit to avoid the
damage of the unit.
3. Please disconnect the power cord to the power supply when you turn
off the unit or intend to stop using for long time.
4. In order to improve the performance of dehumidifier, please keep the
unit in open place awayfrom barriers which may block the air.
5. Please wash the filter with cool water(cooler than 40℃) but
notgasoline or alcohol every two weeks, and put filter back after it
air-dried naturally.
Error code
Error code
cause
solution
E1
Room humidity and
temperature sensor damaged
Ask professionalservice agent for
help

11
SPEC
IFICA
TION
S
(CE) N 842/2006:
R410A is a kind of fluorinated greenhouse gases covered by
the Kyoto Protocol.
E2
Copper tube sensor damaged
Ask professionalservice agent for
help
Model
PD30-WAE-F
Power Source
120V~60Hz
Rated Power (104℉,35%RH)
490W
Rated Current (104℉,35%RH)
4A
Rated Capacity (65℉,60%RH)
30 Pints/Day(16.5L/Day)
Input Power (65℉,60%RH)
340W
IEF(65℉,60%RH)
1.60 Liters/kWh
Motor FLA
0.43A
Motor Compressor
RLA:3.3A LRA:19.4A
Refrigerant
R410A / 124g(4.34ozs)
Maximum Allowable Pressure
5.5MPa
Maximum Operating Pressure High
3.5MPa
Maximum Operating Pressure Low
2.3MPa
Dimension (mm)
408W×268D×574H
Water Tank Capacity
4.8L

12
Its total global warming potential (GWP) is 2088.
This marking indicates that this product should not be
disposed with other household wastes throughout the EU.
To prevent possible hazards to the environment or human
health from uncontrolled waste disposal, please recycle it to
prove the sustainable reuse of material resources. Please
ask return and collection systems or contact the retailer
where the product was purchased to return your used
device, they can recycle products safely.

FCC Warning
This device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any inte rference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates
uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interferenceto radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20cm
between the radiator and your body.
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
Table of contents