NanaWall FSW75 User manual

Owner’s Manual
NanaWall FSW75
Folding Frameless System
This Owner’s Manual contains instructions on the installation, operation, maintenance and warranty
of the NanaWall FSW75 Folding Frameless System. This manual is to be used by the installer
for installation and is to be kept by the Owner for reference. Replacement parts can be ordered
directly through NanaWall Systems.
Nana Wall Systems, Inc.
100 Meadowcreek Drive #250
Corte Madera, CA 94925
800 873 5673
415 383 3148
Fax 415 383 0312
nanawall.com
©2022 Nana Wall Systems, Inc.

NANAWALL FSW75 OWNER’S MANUAL
2
Installation Instructions
The installation of the FSW75 System requires a working
knowledge and experience in the use of tools, equipment
and methods necessary for the installation of aluminum
doors, storefronts, and/or partitions. This practice
assumes a familiarity with preparing a proper and
structurally sound opening, proper anchorage and
assumes an understanding of the fundamentals of
building construction that affect the installation of single
track folding systems. A crew of at least 2 persons is
needed. These systems can be heavy. Use safe lifting
techniques to avoid injury and product damage.
Highly recommended is using an independent NanaWall
Certified Installer, if available, or, at least, an installer
who has some experience in installing NanaWall
systems.
IMPORTANT: READ COMPLETE INSTRUCTIONS
BEFORE BEGINNING INSTALLATION. INSTALL AS
RECOMMENDED; OTHERWISE, THE UNIT MAY
NOT FUNCTION PROPERLY AND ANY WARRANTY,
WRITTEN OR IMPLIED, WILL BE VOID.
CAUTION:
As regulations governing the use of glazed windows,
doors, storefronts, and/or partitions vary widely, it is the
responsibility of the building owner, architect, contractor
or installer to insure that products selected conform to
all applicable codes and regulations, including federal,
state, and local. Nana Wall Systems, Inc. can assume no
obligation or responsibility whatsoever for failure of the
building owner, architect, contractor, or installer to
comply with all applicable laws and ordinances and
safety and building codes.
Please pay special attention to the thickness of the glass.
The NanaWall glass thickness for the panels
is based on the Glass Association of North America
(GANA) recommended minimum glass thickness for fully
tempered Interior butt glazed fixed glass panels.
The FSW75 system is shipped with all necessary
components. However, not included are screws, bolts,
shims, etc. to anchor the unit to the opening. The frame
is shipped knocked down and needs to be assembled.
Panels are usually pre-assembled with glass, ready to be
attached to the installed frame. In most cases, all rollers,
pivots, brushes, and lockings are pre-attached
to the panels.
DESCRIPTION OF SUPPLIED PARTS
First look for an envelope in the shipment, which contains
drawings of the elevation, the layout of the unit and an
Installation Manual. This information together with the
Custom Product Drawings provided by NanaWall at the
time of order will be needed for a successful installation.
As there is no “standard” configuration for FSW75 units,
see Diagram 1 which shows the elevation and layout of a
5 panel unit to illustrate the installation process. Some
items may not be applicable for your unit. Inspect the
custom product drawing, indicating size, configuration
and labeling of the unit ordered.
Check all parts carefully before assembly. Depending on
the unit ordered, some of these parts may already be
pre-installed on the panels. Check that the sizes of the
frame components and panels match with what was
ordered.
The elevation drawing shows the sequence and number
of panels, which depends on the model ordered.
The drawing is always viewed from the outside,
but the locking shown is what is on the inside.
The panels are usually pre-assembled with one upper
carrier for each folding panel and with one specified
locking. The sequence of labeling of panels starts from
the left looking from outside with the left most panel
labeled Panel #1.

NANAWALL FSW75 OWNER’S MANUAL
3
DIAGRAM 1: EXAMPLE OF A 5 PANEL UNIT
Panel #1: folding panel
Panel #2: folding panel
Panel #3: folding panel
Panel #4: folding panel
Panel #5: single/double action end panel with pivot box or
single/double action end panel with floor closer
OUTSIDE
INSIDE
#1 #2 #3 #4 #5

NANAWALL FSW75 OWNER’S MANUAL
4
Other components include:
• Push/pull handles, other handles, or other hardware,
as ordered may not be pre-attached to the panels
and will be in the hardware box or shipped
separately.
• The layout drawing of your unit shows the upper
track components consisting of the head track in the
opening, how they are labeled and how they have to
be connected. The joints for the transitions are
indicated and necessary connectors for connecting
different upper track pieces are provided.
• The location of the removable head track (RHT)
portion to insert the rollers on panels is indicated on
the layout drawing.
• If requested, an overhead door closer will be in the
hardware box and is not pre-attached to the top rail
and has to be installed in the field after final
adjustments were made.
• Specified floor sockets, pivot points and floor closers.
HANDLING OF COMPONENTS
1. Upon receipt, inspect the shipment to ensure it is in
good condition.
2. Make sure that all components and hardware, which
might be shipped separately does not get lost.
3. Store in a clean and dry location and protect against
defacement or damage, especially to the edges of
panels.
PREPARATION OF THE OPENING AND SUPPORT
STRUCTURE ABOVE
Make rough opening width at least 1/2"wider than the
outside unit frame width and rough opening height
about 3/4"taller than the total unit height depending
on how level the support structure above is. See Sheet
2 of the Installation Manual. It is important that the
opening be the correct size.
Product performance that includes operation, depends
on having the gap between the bottom of the panel and
the top of the finish floor be maintained at 7 mm (1/4")
and also the gap between the top of the panel and the
bottom of the head track to be maintained at a nominal
gap of 23 mm (7/8"). The running carriages can be
adjusted, if needed. The finish floor needs to be
absolutely level across the length of the opening.
The top and bottom track length and layout have been
supplied based on the configuration and sizes chosen
and approved. Please refer to the layout drawing of
your particular FSW75 project, to determine the correct
location of the support structure (by others) and for
the support of the head track in the plane of the
opening. It is important that the system is properly
supported at the top.
IMPORTANT: Any application should take into
consideration the following:
1. As the FSW75 system is a top-hung system, it is
essential that a proper substrate with the proper
size and thickness be used for the support structure
above in order to support the head track in the
opening.
2. The structural integrity of the support structure is
critical for proper operation. Vertical deflection of
the header under full live and dead loads should be
the lesser of L/720th of the span and 1/4". It should

NANAWALL FSW75 OWNER’S MANUAL
5
be designed to accommodate the total weight of the
panels (i.e. system weight with 12 mm (1/2") tempered
glass app. 8lb/ft²) in the opening and in the stacking
(unit in open position).
3. Structural support for lateral loads (both windload, if
any, and other lateral force) must also be provided.
4. A qualified engineer or architect should be used to
determine the proper construction details and
support structure to be used in your particular
application.
5. The rough opening should be reasonably level,
plumb and square at all points. There should be no
unevenness or bowing. Make sure that the header is
not tilted or twisted. There should be no bumps on
the floor. The sides should be in the same vertical
plane and not offset of each other. A transit/laser
and other similar precise measuring equipment
should be used. YOU NEED TO ADJUST THE
FLOOR AT THE OPENING TO MAKE IT
ABSOLUTELY LEVEL.
6. See Sheet 10 – 14 of the Installation Manual for
drawings of floor closer, pivot point and floor sockets
to determine sizes of holes or slots that need to be
made in the finish floor and substrate below. As there
are different size floor sockets available, please verify
the type of sockets for this order. If planning to cut
into a post tensioned concrete for the bottom track,
floor closers, pivot points and sockets, a structural
engineer and architect has to be consulted.
7. The finish floor will need to be perfectly level with no
unevenness in the opening area. For the installation
of floor closers, pivot points and floor sockets in
concrete slabs and wood, the substrate should be a
minimum of 4" thick, these components should be
fully embedded into the concrete or wood and the
clear edge distance in concrete or wood should be a
minimum of 2".
8. Floor sockets, pivot points, and floor closers will need
to be installed at precise locations after all panels are
installed and final adjustments are made.
9. For installations into heavy gage, all metal studs must
have wood backing.
10. For better performance it is strongly recommended
that all dead loads such as upper levels, roof, etc. be
constructed and reasonable time for it has been
allowed to settle before a unit is installed.
To avoid future problems, do not install your unit until
the rough opening and the support structure have been
correctly prepared.
UNIT INSTALLATION
The Installation of the unit is described
in the FSW75c Installation Manual:
Sheet 1. Required Tools
Sheet 2. Rough Opening and Unit Dimensions
Sheet 3. Head Track in “kd” (knocked down) Condition
Sheet 4. Assembly of Head Track
Sheet 5. Head Track Shimming
Sheet 6. Recessing Floor Track and Drilling Holes
for Floor Sockets
Sheet 7. Installation Sequence of Panels
Sheet 8. Installation Sequence of Panels
Sheet 9. Panel Alignment and Height Adjustment
Sheet 10. Centered Pivot Point and Bottom Door
Closer Installation
Sheet 11. Pivot Point Top Track for Single/Double Action
End Panel Installation
Sheet 12. Single/Double Action End Panel Installation
Sheet 13. Offset Pivot Point and Floor Closer Installation
Sheet 14. Offset Pivot Point Top Track for Single Action
End Panel
Sheet 15. Installation of Profile Cylinder

NANAWALL FSW75 OWNER’S MANUAL
6
A. FRAME ASSEMBLY AND INSTALLATION
Since there can be an infinite number of variations and
configurations, it is not possible to have step by step
specific instructions that will apply to all units installed.
Below are general instructions that focus on the
installation of a 5 panel unit as shown in Diagram 1. This
may not exactly apply to your particular unit. Please refer
to the Custom Product Drawings for your specific project.
The key to having a properly installed and
operating FSW75 system is to install a perfectly
level upper track at the correct height from the
finish floor level.
Step A1
Look for the labels on the different upper track segments
and set them on the floor as per the layout of the head
track on the custom product drawings.
Step A2
Attach as many of the upper track pieces together that
could be supported and installed easily as one piece. Use
the connectors and set screws provided. See Sheet 4 of
the Installation Manual. Make sure that the transitions
between the track segments are perfectly aligned and
smooth.
Step A3
The roller access head track section is a removable
section in the head track (RHT). This section will need to
be later removed when the panels are installed.
Step A4
The head track is pre-drilled in the factory with anchorage
holes at spacing’s of about 10" (250 mm) for 5/16" (8 mm)
diameter screws or bolts. See Sheet 3 of the Installation
Manual.
The correct fastener spacing in the support structure
within the opening depends on substrate material, design
windload pressures (if exterior) of project, panel height
and other requirements of the project. All anchoring
details and requirements should be determined and
verified by the project structural engineer.
Please pre-drill any additional anchorage holes as needed.
Use appropriate anchorage devices depending on the
project lateral load requirements and adjacent substrate
material and construction. If the factory pre-drilled holes
are sufficient, then 8 mm (5/16") diameter screws can be
used. Make sure they are corrosion resistant and that the
screw head is small enough to fit inside the slot in the
middle of the head track, otherwise it will interfere with
the running carriages. Anchorage devices should
penetrate (embedment) or hold sufficiently to the
opening to withstand necessary lateral loading. Attention
should also be made to the minimum edge distance that
must be maintained for different substrates. Generally, for
wood frame, minimum embedment is 2 1/2" and minimum
edge distance is 3/4", for concrete minimum embedment
is 1 1/4" min. and minimum edge distance is 2".
Step A5
For all anchorage options, set the assembled part of the
upper track into the rough opening at the proper position
relative to the support structure and the finish floor.
Step A6
Support the upper track temporarily in a safe manner.
Step A7
Place hard plastic horseshoe shims tightly at every fixing
point between the upper track and the header. Anchor
the head track with appropriate screws through the pre-
drilled holes or as needed. See Sheet 5 of the Installation
Manual.

NANAWALL FSW75 OWNER’S MANUAL
7
IMPORTANT: ADJUST EACH ANCHORAGE
POINT AS NEEDED TO MAKE THE UPPER
TRACK ABSOLUTELY LEVEL AND PLUMB. USE
A TRANSIT/LASER AND OTHER SIMILAR PRECISE
MEASURING EQUIPMENT TO MAKE THESE
DETERMINATIONS. MAKE SURE NO SHIMS ARE
FORCED TO ENSURE THAT THE UPPER TRACK
IS NOT BOWED OR TILTED.
Upper track segments must be joined such that they
are even, tight and aligned perfectly. Otherwise, the
running carriages may wear out prematurely, which will
then not be covered by warranty. Placing shims at the
meeting points of track segments may help in keeping
the transition points even, even though there may not
be anchorage holes at this point. See Sheet 5 of the
Installation Manual.
Make sure that all surfaces of the upper track are clean
and free of any debris, especially cuttings from drilled
holes.
Do not attach anything from the side against the head
track.
Do not drill any holes for sockets, pivot points,
and floor closers, yet!
B. PANEL AND BOTTOM TRACK INSTALLATION
FOR ALL FOLDING PANELS
As there can be many possible configurations, panel
installation will vary with each unit. Below are guidelines
for a 5 panel unit shown in Diagram 1. Determine the
interior/exterior side of the panels and install them such
that they are facing the correct direction. Please also refer
to D. PANEL INSTALLATION OF A SINGLE/DOUBLE
ACTION END PANEL after following the instructions in C.
Step B1
Check all the carriers on all the folding panels. Make sure
all the locking nuts are securely tight. Do not make any
adjustments on the carriers, yet.
Step B2
Find the center line of the head track with a laser on the
floor along the length of the opening, and mark it with a
chalk line. This is now your centerline for the bottom
track (U-channel 13/16" x 13/16"). Then mark the
dimensions of the U-channel on the floor and if concrete,
cut and chisel out the concrete to recess the bottom
track into the floor. Make sure that the full underside of
the U-channel rests on a flush and level surface and fix it
temporarily into place. Before you use suitable material to
finally anchor the U-channel into the floor, install all
folding panels and single/double action doors. After
everything is installed and adjusted including the floor
socket for the locking point of the pivot panel, use
suitable material to finally fix the bottom track in place.
Step B3
Before inserting the panels, remove the roller access head
track section (RHT). See Step 0 on Sheet 7 of the
Installation Manual. Hang 1st folding panel (Panel #4) by
inserting the carrier of this panel into the opening in the
head track. Secure and support panel from underneath
with i.e. wedges or similar before you proceed with the
2nd panel (Panel #3). Then install 2nd panel the same
way and line up the hinges with the 1st panel.
Add the hinge pins to the hinges at the bottom and
top. Secure hinge pin with the set screws from the
side. Tighten set screws and then back it off a ¼ turn.
Afterwards add cover on top of hinge pin.
See also Sheet 7 of the Installation Manual.
Step B4
Install additional folding panels in the same manner.

NANAWALL FSW75 OWNER’S MANUAL
8
Step B5
After you inserted all folding panels, secure them in the
opening. Before you reinstall the removable head track,
take the top pivot point for the 1st panel (Panel #1) from
the hardware box and slide it inside the top track. Now
put the RHT back on and make sure that the joints are
aligned perfectly.
Step B6
To install the 1st panel at the side (Panel #1), slide the top
pivot point over to the side of the RHT. Check, that the
dimension from the edge of the top track to the center
point of the axle Is 44 mm (1 3/4"). Fix the pivot point in
position. Line up the pivot point at the bottom inside the
U-channel with the pivot point at the top by using a
transit/laser or other similar precise measuring
equipment. See also Sheet 8 of the Installation Manual.
Step B7
Install the 1st panel by setting it on top of the bottom
pivot point first and then attach it to the top pivot point
by pushing up the bolt of the top pivot point and screwing
it onto the shoe inside the top clamping profile. Before
you tighten the bolt and nut, measure the horizontal
reveal at the bottom and top and keep it consistent with
the rest of the panels.
Step B8
Now you can attach the 1st panel (Panel #1) to the
adjacent folding panel (Panel #2) by adding the hinge pin
as described under Step B2.
IMPORTANT: DO NOT USE EXPANDING
MATERIAL TO FIX THE BOTTOM TRACK IN
PLACE. MAKE SURE THAT THE INSIDE
DIMENSION OF THE U-CHANNEL STAYS AT 16
MM (5/8") OVER THE FULL LENGTH OF THE
TRACK TO ALLOW THE BOTTOM GUIDING
ROLLERS OF THE FOLDING PANELS TO RUN
SMOOTHLY THROUGH THE TRACK.
The bottom track will be supplied in full length. In the
area of the single/double action end panel (panel #5)
you have the option of cutting the bottom track short
(width of panel #5) and instead use a floor socket to
lock the panel in place. See Sheet 6 of the Installation
Manual.
Do not install any single/double action end panels, yet.
Do not drill any additional holes for sockets,
pivot points and floor closers, yet!
C. GAPS AND ADJUSTMENT
After inserting all the folding panels, operate the unit
and check the vertical and horizontal reveals. Check if
all panels are vertically straight and if you left enough
space for the single/double action end panel. See Sheet 9
of the Installation Manual. Between the folding panels
there should be an even gap of 2 mm (about 1/16"). Any
problems may be due to the head track not being
absolutely level.
The horizontal spacing between the bottom of a panel
and finish floor should be 7 mm (about 1/4") consistently
across the width of the opening and 23 mm (7/8")
at the top.
If the gaps are not correct, then adjust the upper track
by removing or adding shims above the head track as
needed. The upper track has to be perfectly level.
If there are still issues on the gap between panels and the
gap at the bottom not being correct, then the running
carriages can be adjusted. The carriages on the panels
are normally set from the factory to have a gap of 23 mm
(7/8") from the bottom of the head track to the top of the
top rail.
To adjust the height of the panels, use a 19 mm open jaw
wrench from the side. Clamp on the flat part of the bolt
that is located near the bottom of the roller with the

NANAWALL FSW75 OWNER’S MANUAL
9
11 mm open jaw wrench and adjust the height. Counter-
clockwise rotation = less floor clearance; clockwise
rotation = more floor clearance. See Sheet 9 of the
Installation Manual.
After final adjustments make sure to really tighten down
the nut.
After you adjusted all folding panels, measure the width
for the single action end panel (non-sliding) again and
make sure it fits into the opening.
D. PANEL INSTALLATION FOR SINGLE/
DOUBLE ACTION END PANELS (NON-SLIDING)
CENTERED AND OFFSET INCLUDING PIVOT
POINT AND FLOOR CLOSER INSTALLATION
Holes and slots in the floor for the pivot points and floor
closers have to be made at exact precise spots. There is
no second chance if the hole/slot location is off. See Sheet
10-14 of the Installation Manual.
Step D1
Start at the bottom and use the chalk line as a reference
line. Measure the overall width of the panel and compare it
with the dimension on the custom product drawing. To
this dimension add 3/16" (4 mm) at each end to make sure
the correct 3/16" (4 mm) gap between the panels and
between the panel to the wall is maintained. Then the
panel has to fit in the remaining opening.
Step D2
For the center pivot end panel (non-sliding) with pivot
point, the dimension for the center of the pivot axle to the
adjacent edge of the panel (end cap) should be 1
11/16" (43 mm) plus the additional 3/16" (4 mm) for the gap
to the wall. Please check custom product drawing for
swing direction (inside/outside). See Sheet 10 of the
Installation Manual. This means a total of 1 7/8" (47 mm)
to the edge
of wall. Mark this dimension on the chalk line. If concrete,
use a diamond core drill bit with 1 1/4" diameter. Install the
pivot point and if necessary, use suitable material to fix it
in place. Then install the top pivot axle into the top track.
Start inserting the upper flush part into the top track, turn
it a ¼ counter clock wise, push it up higher and turn it
another ¼ clock wise. Before you fix the axle with the 2
set screws in place, please use a transit/laser or other
similar precise measuring equipment to line up the center
of the bottom pivot point with the center of the top axle.
See Sheet 11 of the Installation Manual.
In preparation for the installation of this panel, take off the
end cap and top cover on the inside. Screw the adjustable
bracket onto the threaded bolt of the top axle and make
sure that the set screw at the side is lose. Now you can
install the panel by lifting the pivot axle, that is installed
underneath the bottom of the panel, on top of the bottom
pivot point. Line the top axle with bracket up with the
shoe that is inserted into the top profile and connect both
parts with one another. See Sheet 12 of the Installation
Manual.
Before you finally tighten down all screws, make sure that
all dimensions are set correct, the panel can be opened
and closed with the right clearance and check if the
panel is plumb and level. Then fix all screws in place and
secure the top axle by fixing the set screw from the side.
Afterwards put the top cover with end cap back on.
Step D3
For the offset pivot end panel (non-sliding) with pivot
point, the dimension for the center of the pivot axle to the
adjacent edge of the wall should be 1/16" (2 mm) and it
should be offset to the chalk line by 2 1/16" (52 mm).
Please check custom product drawing for swing direction
(inside/outside). See Sheet 13 and 14 of the Installation
Manual. Mark this point and if concrete, use a diamond
core drill bit with 1 1/4" diameter. Install the bottom pivot
point and if necessary, use suitable material to fix it in

NANAWALL FSW75 OWNER’S MANUAL
10
place. Then install the receiver box for the top axle by
hanging it off on the side of the top track and fix it slightly
with the 2 set screws. Use a transit/laser or other similar
precise measuring equipment to line up the center of the
bottom pivot point with the center of the top receiver box.
The 2 offset pivot brackets are installed on panel #5
already. When you start installing this panel, set the
bottom pivot axle on top of the pivot point and line up the
top bracket with the receiver box at the top. Take the top
axle out of the accessory box and connect the bracket
and the receiver box by sliding it in from underneath. Fix
the top axle with the set screw from the side and add the
cover on top of the hinge pin. Before you finally tighten
down all screws, make sure that all dimensions are set
correct, the panel can be opened and closed with the
right clearance and check if the panel is plumb and level.
Step D4
For the center pivot end panel (non-sliding) with floor
closer, the dimension for the center of the pivot axle of
the floor closer to the adjacent wall should be 2 1/2" (64
mm). Please check custom product drawing for swing
direction (inside/outside). See Sheet 10 of the Installation
Manual. Mark this dimension on the chalk line. Then mark
the dimensions of the box on the floor and if concrete, cut
and chisel out the concrete to recess the floor closer into
the floor.
Make sure that the full underside of the box rests on a
flush and level surface and fix it temporarily into place.
Then install the top pivot axle into the top track. Start
inserting the upper flush part into the top track, turn it a ¼
counter clock wise, push it up higher and turn it another
¼ clock wise. Before you fix the axle with the 2 set screws
in place, please use a transit/laser or other similar precise
measuring equipment to line up the center of the axle of
the floor closer with the center of the top axle. See Sheet
11 of the Installation Manual.
In preparation for the installation of this panel, take off
the end cap and top cover on the inside. Screw the
adjustable bracket onto the threaded bolt of the top axle
and make sure that the set screw at the side is lose. Now
you can install the panel by lifting the receiver shoe that
is installed underneath the bottom of the panel, on top of
the axle of the floor closer. Line the top axle with bracket
up with the shoe that is inserted into the top profile and
connect both parts with one another. See Sheet 12 of the
Installation Manual.
Before you finally tighten down all screws, make sure that
all dimensions are set correct, the panel can be opened
and closed with the right clearance and check if the
panel is plumb and level. Then fix all screws in place and
secure the top axle by fixing the set screw from the side.
Afterwards put the top cover with end cap back on.
After everything is installed and adjusted including the
floor socket for the locking point of the pivot panel, use
suitable material to fix the floor closer in place.
Step D5
For the offset pivot end panel (non-sliding) with floor
closer, the dimension for the center of the pivot axle of
the floor closer to the chalk line (CL of track) should be 2
1/16" (52 mm). The center point is then offset to the wall
by 1/16" (2 mm). Please check custom product drawing for
swing direction (inside/outside). See Sheet 13 and 14 of
the Installation Manual. Mark this dimension on the floor.
Then mark the dimensions of the box on the floor, too
and if concrete, cut and chisel out the concrete to recess
the floor closer into the floor. Position the box at the right
location in relationship to the edge of the wall. Make sure
that the full underside of the box rests on a flush and level
surface and fix it temporarily into place. Then install the
receiver box for the top axle by hanging it off on the side
of the top track and fix it slightly with the 2 set screws.
Use a transit/laser or other similar precise measuring
equipment to line up the center of the bottom axle of the
floor closer with the center of the top receiver box.

NANAWALL FSW75 OWNER’S MANUAL
11
The 2 offset pivot brackets are installed on panel #5
already. When you start installing this panel, set the
bottom pivot axle on top of the pivot axle of the floor
closer and line up the top bracket with the receiver box
at the top. Take the top axle out of the accessory box and
connect the bracket and the receiver box by sliding it in
from underneath. Fix the top axle with the set screw from
the side and add the cover with screw. Before you finally
tighten down all screws, make sure that all dimensions are
set correct, the panel can be opened and closed with the
right clearance and check if the panel is plumb and level.
After everything is installed and adjusted including the
floor socket for the locking point of the pivot panel, use
suitable material to finally fix the floor closer in place.
Before you put on the cover for the floor closer, make sure
to measure how much to cut off to make it fit with the
edge of the wall.
E. FINAL STEPS
Holes and slots in the floor for the pivot points and floor
closers have to be made at exact precise spots. There is
no second chance if the hole/slot location is off. See Sheet
10-14 of the Installation Manual.
Step E1
Close and lock all panels into position. For proper
operation, follow the instructions in the Operation section
of this manual. Check that the system operates and
functions properly
Step E2
Attach handles and other hardware that have not been
pre-attached. Attach the profile cylinder (if any) to
the locking gear by inserting it into the lock hole and
attaching the set screw through the screw hole on the
gear located at the edge of the panel. Cut the set screw,
if needed. See Sheet 15 of the Installation Manual.
Step E3
Correct any problems before you finish the trimming. Do
not attach any trimming directly to the top track. Be sure
that the removable head track piece can be accessed and
removed if needed. The head track should not be subject
to any loads from suspended ceilings, etc.
PROTECTION OF THE UNIT DURING
THE CONSTRUCTION PHASE
It is important that during the construction phase
the unit be kept closed, covered and protected from
damage. During this phase, a unit is often subject to the
most extreme conditions from all types of construction
operations that can permanently damage and destroy
it. A unit can be damaged by cement splatter, tar, paint,
weld splatter, falling objects, construction dust, sand
blasting, etc. All temptations to use the large opening
of an installed system for easy ingress and egress by
tradesmen should be resisted.

NANAWALL FSW75 OWNER’S MANUAL
12
Operation And Maintenance
Of Nanawall Products
OPERATION OF A NANAWALL FSW75 –
FOLDING FRAMELESS SYSTEM
For opening and closing the single track folding system,
please observe the special notes on the following pages in
as far as they relate to your unit.
When operating the system similar to any other
door, please do not place your fingers between
the panels/pivot points. Be very careful when
you operate the panels and avoid glass to glass
contact between the panels!!
Only properly trained personnel should operate the unit.
No children should operate the unit.
Do not force the system if not operating properly. If you
encounter any difficulties in operating the unit, please
have it inspected by a NanaWall Certified Installer as
soon as possible.
The correct sequence of opening and closing of panels is
dependent on the configuration ordered. Panels must be
opened and closed in the right order in a gentle manner.
Opening and Closing a Unit.
1. If available, please open the single/double action end
panels, first.
2. Disengage all of the locking points on each folding
panel. Operation of each type of lock as follows:
a. Profile Cylinder – turn with key or thumb turn.
b. Quick Release Lock – pull knob and lift up/down.
3. Now you can open the folding panels by slightly
pushing against 2 adjacent panels from the front,
where the hinge part with hinge pin is located in your
direction. The panels fold together and you can push
them gently from the side using both hands.
4. When you have a swing panel attached to a folding
panel with carrier, make sure that you open the swing
panel 180°, first and keep him in this position when
you fold the panels to the side.
5. If there are more panels stacking to one side or both
sides (left/right with up to 6 panels), please be sure to
handle the chain of panels with care and fold them to
the correct side. Do not force.
6. For closing, please proceed in reversed order as
described above. To pull the panels from the stacked
position, you will need to grasp the first panel by the
edges with both hands as high as possible. Move
evenly.
7. Make sure each folding panel is placed in its proper
position in the opening and engage the locking point
before moving the next panel. Do not place your
fingers between the panels/pivot points. Do not force
any locking point.
8. For units with multiple panels folding to one side
or both sides (left/right with up to 6 panels), make
sure that each chain of panels is placed in its proper
position in the opening and engage all locking points
before moving the next chain of panels.

NANAWALL FSW75 OWNER’S MANUAL
13
RECOMMENDED MAINTENANCE
OF NANAWALL PRODUCTS
Some General Considerations on all Projects:
1. It is important that the product is properly installed.
A poorly installed unit will not function properly. This
will cause more abnormal force or stress on the
components and will lead to premature failure. When
operating the unit, the panels should generally be
able to be moved easily by one person. When moving
across joint locations of head track transitions, there
should be no bumps, otherwise the carriers may
prematurely wear out. All locking points should
engage smoothly. There should be no rubbing on the
floor and no binding. When the unit is closed, the
horizontal reveal between panels and the head track
and between panels and the floor should be
consistent. Please have all problems corrected as
soon as possible by a qualified technician or a
NanaWall Certified Installer.
2. From time to time, due to building movement or
settlement, a unit may need to be adjusted by a
qualified technician or a NanaWall Certified Installer
to compensate for any building change.
3. It is important that a unit is operated properly.
Locking points should be gently opened and closed
and not forced. Panels should be opened and closed
in the proper manner and sequence. See the
Operation section for proper operation.
4. Periodically check for worn or damaged components
and replace as soon as possible. A unit with
nonworking components will subject the other
components to increased stress and lead to
premature failure. A unit with worn or damaged
components will compromise the performance level
expected.
5. Remove debris and other foreign bodies which
have accumulated in the head track and sockets
immediately to prevent damaging the carriers
and maintain proper locking. Clean and lubricate all
movable parts and components as needed.
Check brushes for proper seating and condition.
Remove dust and any deposits from these brushes.
6. The finished aluminum or stainless steel surface
needs periodic cleaning and maintenance. Its
appearance may be marred by harsh chemicals,
abuse or neglect. Frequency of cleaning depends
on exposure and needs. For aluminum surfaces,
generally warm soapy water should be sufficient.
Stubborn stains and deposits may be removed
with mineral spirits. Heavier accumulations can be
removed with a mild solution of household detergent.
For all surfaces, aggressive alkaline or acid cleaners
should not be used. Excessive abrasive rubbing
should be avoided. Sealants and weather stripping
may be affected by strong organic solvents.
7. All hardware, hinges and handles should
be periodically cleaned with a soft cloth
and mild cleanser. Excessive abrasive rubbing
should be avoided.
8. It is highly recommended that a maintenance/
service contract be entered with a NanaWall certified
installer, who can clean, lubricate and inspect
on a periodic basis.

NANAWALL FSW75 OWNER’S MANUAL
14
MAINTENANCE CHECK LIST
Following recommended check list of Maintenance Notes
to be carried out on a regular basis by a maintenance
person:
a. Clean upper track
b. Check height adjustment and setting
of each panel
c. Check if all panel end caps are in place
and fixed
d. Check if all carriages can be moved easily
e. Check if counter nuts on carriages are
adequately fastened
f. Check if hinges can be moved easily; lubricate
if necessary
g. Check if pin carriers in pivot panels are
in the right position
h. Ensure that the lower locks can be moved
easily; lubricate if necessary
i. Check if floor sockets, pivot points and door
closers are adequately fastened to the floor
j. Remove any dirt from the floor sockets, pivot
points and bottom door closers
k. Ensure that any lock and profile cylinder can be
moved easily
GLASS INSTALLATION AND GLAZING
This section applies only if you need to install glass for
any reason. Proper glass installation is critical, as, with the
NanaWall single track sliding system, glass is a structural
part of the panel.
Glass, with appropriate dimensions, thickness and
specifications will be needed. Depending on the model,
widths of all glass panels may not be equal. Ask NanaWall
for the glass dimensions. Please note that glass is
required to be safety glass – either fully tempered or
laminated as specified for a particular order. Check with
all applicable codes and regulations.
Glass shall meet the current requirements of ASTM C
1306 “Standard Specifications for Flat Glass” for quality,
thickness and dimensional tolerances. Tempered float
glass shall meet the current requirements of ASTM C
1048 “Standard Specifications for Heat-Treated Flat
Glass - Kind HS, Kind FT Coated and Uncoated Glass.”
All tempered glass shall have a permanent logo, which
signifies Safety Commission 16 CFR-1201 and the safety
glass test requirements of ANSI Z 97.1 (current editions)
or other equivalent safely standards.
Follow all proper applicable glass installation and glazing
techniques as recommended in the Flat Glass Marketing
Association (FGMA) “Glazing Manual” and “Sealant
Manual”. Always use suction cups to shift glass within
an opening. The panels would need to be removed
from the opening to install the glass. Panels can be laid
flat on sawhorses.
Please contact NanaWall before you replace a glass
pane in order to get the right material and instructions
to glaze the panel!

NanaWall Limited Warranty
NanaWall is pleased to provide the following warranty to the owner of NanaWall products, including the initial purchaser
and all subsequent owners (“Owner”), subject to all terms and conditions stated herein. This Warranty supersedes all
previous product warranties and is the exclusive statement of all commitments and rights of NanaWall with respect to its
products sold on or after May 1, 2022, to be installed in the United States (excluding territories) or Canada.
NanaWall shall have no obligation to respond under this Warranty until receipt of proper notice of a claim and an
opportunity to respond. Upon notice and confirmation by NanaWall of a condition covered under this Warranty, NanaWall
will respond in good faith and in a timely manner as follows:
TEN YEAR COVERAGE.
For ten (10) years from the date of delivery by NanaWall (“Delivery”), NanaWall will respond as follows:
Insulated Glass. For an insulated glass unit with a permanent material obstruction of vision due to a premature failure of
the glass seal, NanaWall will ship a replacement glass unit or panel. Exception: insulated glass units for cero® are covered
for five (5) years from Delivery.
Powder Coat or Baked-on Fluoropolymer Surface Finish of Aluminum Profiles. For powder coat or baked-on
fluoropolymer surface finish not functioning as an Effective Surface Material (“ESM”*), NanaWall will, at its option,
(1) assume reasonable costs to restore the finish using standard commercial refinishing techniques or
(2) ship replacement parts. Uneven fading is not a covered condition due to environmental variables.
*An ESM is a finish without (1) substantial cracking, chipping, or peeling due to the deterioration of the finish (exclusive of
mechanical damage); (2) chalking in excess of a numerical rating of 8 as per ASTM D 659; or (3) fading or color changes
in excess of 5 NBS units as per ASTM D 2244.
Rollers. For a roller with material or workmanship issues that significantly impair proper operation and function,
NanaWall will ship a replacement roller.
Wood and Other Remaining Components (for product installed by an independent NanaWall Certified Installer or
Approved Installer**). For all remaining components of NanaWall products not otherwise addressed herein with a material
or workmanship issue that substantially impairs operation and function, NanaWall will, at its option, (1) ship a replacement
part or product or (2) ship any replacement part or replacement product in the same stage of fitting and/or finishing as
originally supplied by NanaWall. This includes wood frame components, hinges, handles, locking mechanisms, tracks,
beads, and weather-stripping.
FIVE YEAR COVERAGE.
For five (5) years from Delivery, NanaWall will respond as follows:
Laminated Glass. For a laminated glass unit with permanent material obstruction of vision due to premature delamination,
NanaWall will ship a replacement glass unit or panel.
Wood and Other Remaining Components (for product NOT installed by an independent NanaWall Certified Installer or
Approved Installer**). For all remaining components of NanaWall products not otherwise addressed herein with a material
or workmanship issue that substantially impairs operation and function, NanaWall will ship a replacement part or product
without charge in the same stage of fitting and/or finishing as originally supplied by NanaWall. This includes wood frame
components, hinges, handles, locking mechanisms, tracks, and weather-stripping.
PAGE 1 OF 4

THREE YEAR COVERAGE.
For three (3) years from Delivery, NanaWall will respond as follows:
Anodized Surface Finish of Aluminum Profiles. For anodized surface finish of aluminum profile not functioning as
an ESM,* NanaWall will, at its option, (1) assume reasonable costs to restore the finish on a non-compliant (non-ESM)
material using standard commercial refinishing techniques or (2) ship a replacement part.
ONE YEAR COVERAGE.
For one (1) year from Delivery, NanaWall will respond as follows:
Screens. For a screen part (excluding the screen mesh) with a material or workmanship issue that substantially impairs
the function of the screen, NanaWall will, at its option, (1) ship a replacement screen or (2) upon return by owner, repair
the screen without charge.
ADDITIONAL SERVICE INFORMATION
This Warranty does not cover labor costs to remove existing parts or products, install a replacement part or product, costs
to finish wood products, or the cost to repair or replace surrounding substrates, trim, or other work. Nor does it cover
costs incurred due to delays or other construction costs, costs for late or damaged delivery, loss of revenue, loss of time,
liquidated damages, inconvenience, or loss of use of the product or any parts or components. NanaWall reserves the right
to determine whether or not a covered condition exists. If the claim is not covered under this Warranty, NanaWall may
charge and collect a fee for on-site product inspections.
Any replacement part or product will be shipped to the location of original product delivery by NanaWall. Replacement
products will be the closest equivalent current product and may not be an exact match to the original. If providing a
replacement part or product is not commercially practicable, NanaWall may elect to refund the purchase price of the
affected product in full satisfaction of its obligations.
Wood. Wood components must be properly finished on all sides promptly after receipt of unit before installation of unit,
and prior to exposure to weather. Repair or replacement of a warped wood panel or frame can be delayed by up to 12
months from date of claim to allow the wood component to adjust to local environmental conditions.
Glass. Unloading the replacement glass/panel from the delivery truck is the responsibility of the owner. Due to the
weight of the product, appropriate manpower and/or equipment will be needed to unload and move the glass/panel to
the location for replacement. Depending on the size of the replacement part and interior building dimensions, it may not
be possible to transport the glass/panel through the interior of the building. NanaWall is not responsible for any costs
associated with moving the replacement glass/panel at the delivery location.
**Whether an installer is an independent NanaWall Certified Installer or Approved Installer is determined by the installer’s
status as of the date of delivery. NanaWall maintains information regarding the installers designated as Certified Installers
or Approved Installers.
NOTICE PROCESS
Written notice of any claim under this Warranty with supporting documents such as photos or videos must be given to
Nana Wall Systems, Inc. via email to [email protected]
or via mail to 100 Meadowcreek Drive, Corte Madera, CA
94925, promptly when discovered. A condition will not be covered under this Warranty if there is a failure to notify
NanaWall in writing (1) within 7 days of receipt of the product for any defect which an ordinary inspection would reveal,
(2) within a reasonable time during the warranty period after an impairment in operation and use is manifest or a hidden
defect is discovered, or (3) for claims first made after expiration of the coverage period outlined in this Warranty.
NANAWALL LIMITED WARRANTY
PAGE 2 OF 4

DISCLAIMERS & LIMITATIONS
Any responsibility of NanaWall is contingent upon owner fulfilling its notice obligations as stated in this Warranty.
The owner shall have no standing to assert a claim absent timely notice to NanaWall and an opportunity to cure.
The remedies prescribed in this Warranty are the exclusive and sole remedies available to the owner who hereby waives
any claim not encompassed herein. This exclusivity and waiver survive expiration of warranty coverages herein. In no
event shall the liability of NanaWall or any seller of NanaWall product exceed the price paid for the product.
This Warranty is the sole and exclusive warranty for NanaWall products. ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE
DISCLAIMED. NANAWALL SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES. Some state
and federal laws may not allow disclaimers of implied warranties or exclusions of incidental or consequential damages,
so these limitations or exclusions may not apply to you. Where federal law prohibits disclaimer of implied warranties,
the duration of any implied warranty is limited to the duration of the relevant coverage period, if less than the statutory
limitation period. This Warranty gives you specific legal rights, and you may also have other rights which vary from
state to state.
This Warranty may only be modified by a writing signed by an officer of NanaWall. Any action taken by NanaWall does not
create a new warranty or extend the duration of the original product warranty. A failure by NanaWall to enforce a warranty
provision shall not constitute a waiver barring subsequent enforcement.
EXCLUDED CONDITIONS.
This Warranty does not cover the following conditions, or any damage or issues caused in whole or part by the
following:
• Product selection, application, storage, handling, modification, or waterproofing; Movement of surrounding substrates,
including deflection of the header of more than ¼”, or any other stresses on product; Installation, flashing, or
integration into the structure; Failure to prevent the effects of sheeting rain or water; Failure to install proper weep
holes in sill where needed, and failure to properly drain water exiting weep holes in the sill; Failure to meet code or
specification requirements.
• Finishing by anyone other than NanaWall, including but not limited to, not properly finishing all sides of wood
products promptly after receipt of unit, before installation of unit and before exposure to weather, finishing exterior
wood in dark colors, or not refinishing periodically; Discoloration of finish; Failure to immediately repair any breaches
such as scratches, chips, or abrasions in any finish or aluminum profile.
• Condensation, frost, or mold caused by high interior relative humidity; Installation near swimming pools; Harsh
chemicals such as road salt, solvents, acid, brick or mortar wash, or cleaning chemicals; Corrosion or tarnish
on product installed within two (2) miles of any coastal area or body of salt water, or other harsh or corrosive
environments or chemicals.
• Normal weathering, wear and tear; Failure to follow the NanaWall operation and maintenance instructions; Failure to
operate the product for more than one month; Failure to clean and maintain aluminum surfaces in accordance with
AAMA 609 and 610 or not maintaining adequate cleaning records.
• Imperfections in glass that do not affect the product’s structural integrity or obscure vision and cannot be detected
from within 10 feet as per ASTM C 1036; Accidental or spontaneous glass breakage; Glass breakage due to thermal or
other stresses, or glass with film or other coatings applied to the surface; Industry accepted bow, warp or distortion in
glass, and minor variations in glass color; Glass not installed as per NanaWall’s instructions.
NANAWALL LIMITED WARRANTY
PAGE 3 OF 4

Nana Wall Systems, Inc.
100 Meadowcreek Drive #250
Corte Madera, CA 94925
800 873 5673
415 383 3148
Fax 415 383 0312
nanawall.com
©2022 Nana Wall Systems, Inc.
PAGE 4 OF 4
• Variations in wood grain or color; Warp within the allowable warp tolerance for wood panels per ANSI/WDMA I.S.
6A-01; Warpage on wood panels caused by leaving panels in the open position exposed to the elements or not
engaging the locking points properly when in the closed position; Resin or sap bleeding from wood panels.
• Panel shrinkage or expansion caused by change in weather; Expansion or bowing of aluminum units caused by
exposure to sunlight or caused by temperature difference between interior and exterior panel surfaces.
• Acts of God, falling objects, fire, accidents, external forces, or other conditions beyond NanaWall’s control.
• Gas fill or retention levels in insulated glass units.
• Field testing of Product; Performance of the Product in conformance to any published NanaWall testing results (e.g.
air infiltration, water infiltration, structural loading). Published test results measure the laboratory performance of a
single sample of the product of a certain size and configuration. Performance during testing may vary depending
upon handling, installation, use, maintenance, and testing.
• Products or components not supplied by NanaWall; Products that have not been paid for in full; Products ordered in
larger sizes or special configurations beyond NanaWall’s published specifications. Product with glass that is heavier
than NanaWall specifications; Product that has been modified or altered in any manner.
NANAWALL LIMITED WARRANTY

Nana Wall Systems, Inc.
100 Meadowcreek Drive #250
Corte Madera, CA 94925
800 873 5673
415 383 3148
Fax 415 383 0312
nanawall.com
©2022 Nana Wall Systems, Inc.
NanaWall Warranty Registration
Must be filled out and returned to Nana Wall Systems, Inc., 100 Meadowcreek Drive, Corte Madera, CA 94925
within 30 days from date of purchase of the NanaWall in order for the limited warranty to become effective.
NANAWALL ORDER # ________________________ PROJECT NAME _____________________________
Date of Purchase_____________________________ Purchaser Name ______________________________
PROPERTY OWNER
Name _____________________________________ Address ____________________________________
Telephone _________________________________ E-mail ______________________________________
Project Address (if different from above) ____________________________________________________________
INSTALLATION
Installer Name ______________________________ Address ____________________________________
Telephone _________________________________ E-mail ______________________________________
Type of project ■ new residential ■ restaurant ■ shopping mall
■ residential remodel ■ office building ■ other ___________________________
Architect Name _____________________________ Address ____________________________________
1. Is the installation complete? ■ yes If yes, date completed ________________
■ no If no, date scheduled _________________
2. Have you been shown how to ■ yes Is operation satisfying? ■ yes ■ no
operate your new NanaWall? ■ no If no, why not? ________________________________
Print Name _________________________________
Signature __________________________________ Date _______________________________________
Table of contents
Popular Indoor Furnishing manuals by other brands

Takara Belmont
Takara Belmont Manual Barber chairs Installation and operating instructions

Costway
Costway HU10407 manual

The Land of Nod
The Land of Nod Wrightwood Twin-over-Twin Bunk Bed Assembly instructions

Belnick
Belnick Parsons Assembly instructions

möbelando
möbelando Iwaniska I MEGV111R Assembling Instruction

Furniture of America
Furniture of America Sania CM3324PT-VN Assembly instructions