2.4 RATING PLATE INFORMATION
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the appliance.
For rating plate location, see “INSTALLATION OVERVIEW” section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
CERTIFIED UNDER/HOMOLOGUESELONLES NORMES: CSA2.33-2009,ANSI Z21.88-2009 VENTED GAS FIREPLACE HEATER / FOYER DE CHAUFFAGEAU GAZAVEC EVACUATION
W385-0278/ D
SERIALNUMBER/NO. DE SERIE: BGD/BCDV42
DIRECT VENT GAS FIREPLACE. APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING ROOM
INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE
WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES,
IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND
SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT
APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME
INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A.
FOYERAGAZ VENTILE DIRECT. HOMOLOGUEPOURINSTALLATION DANSUNECHAMBRE ACOUCHER,
UNE SALLEDE BAIN ETUN STUDIO.APPROPRIE POUR INSTALLATION DANS UNE MAISON
MOBILE SI SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORMECAN/CSA
Z240MHSERIEDEMAISONS MOBILESEQUIPEESAU GAZ, ENVIGUEUR AU CANADAOUAUX
ETATS-UNISDE LANORMEDE SECURITE ETDECONSTRUCTION DE MAISONS
MANUFACTUREES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME
D'ETATS-UNISNE PEUTETREAPPLIQUEE,SE REFERERALANORMERELATIVE AUCRITERE
DEMESURES DESECURITECONTRE L'INCENDIEPOURLES INSTALLATIONS DANS LES
MAISONS MANUFACTURES, LES SITES ETLES COMMUNAUTES, ANSI/NFPA 501A.
9700539 (WSL) 4001657 (NGZ)
4001658 (NAC) 4001659 (WUSA)
MANIFOLD PRESSURE: 3.5" WATER COLUMN MANIFOLD PRESSURE: 10" WATER COLUMN
PRESSION AU COLLECTEUR: 3.5" D'UNE COLONNE D'EAU PRESSION AU COLLECTEUR: 10" D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUMN MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE: 4.5" D'UNE COLONNE D'EAU PRESSION D'ALIMENTATION MINIMALE: 11" D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN
PRESSION D'ALIMENTATION MAXIMALE: 7.0" D'UNE COLONNE D'EAU PRESSION D'ALIMENTATION MAXIMALE: 13" D'UNE COLONNE D'EAU
BGD42N / BCDV42N MODEL BGD42P / BCDV42P
0-4500FT (0-1370m) ALTITUDE / ELEVATION 0-4500FT (0-1370m)
28,500 BTU/h INPUT / ALIMENTATION 24,000 BTU/h
20,000 BTU/h REDUCED INPUT /ALIMENTATION REDUITE 18,000 BTU/h
NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS
DOORS CERTIFIED WITH THIS UNIT ONLY.
WARNING:DO NOT ADDANY MATERIAL TO THEAPPLIANCE, WHICH WILL COME IN CONTACT
WITH THE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS /
DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
TOP/ DESSUS 0 RECESSED DEPTH / PROFONDEUR D'ENCASTRE 22”
FLOOR / PLANCHER 0 VENT SIDES / COTES DE L'EVENT 1"
SIDES / COTES 0 VENTTOP / EVENT SUPERIEUR 2"
BACK / ARRIERE 0 VENT BOTTOM / EVENT INFERIEUR 1"
MANTEL / MANTEAU 5" *
VENT HEAT SHIELD / PROTECTEUR DE CONDUIT D’ÉVACUATION
1”
* MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE: 5". SEE
INSTRUCTION MANUAL FOR GREATER EXTENSIONS. REFERER AU MANUEL D'INSTRUCTION POUR
DES EXTENSIONS PLUS GRANDES.
MINIMUMANDMAXIMUM HORIZONTALVENT LENGTHSARE 11INCHESAND20FEETRESPECTIVELY.
MINIMUMAND MAXIMUM VERTICAL VENTLENGTHS ARE 36 INCHESAND 40 FEET RESPECTIVELY.
LES LONGUEURS HORIZONTALES MINIMALE ET MAXIMALE SONT 11 POUCE ET 20 PIEDS
RESPECTIVEMENT.LESLONGUEURS VERTICALESMINIMALE ETMAXIMALE SONT 36POUCE
ET 40PIEDS RESPECTIVEMENT.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE
AVEC CET APPAREIL. UTILISER AVEC LES PORTES
VITREES HOMOLOGUEES SEULEMENT AVEC CETTE UNITE.
AVERTISSEMENT:
N'AJOUTEZ PAS A CET APPAREILAUCUN MATERIAU DEVANT ENTRER
EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR
LE FABRICANT.
THE APPLIANCE MUST BE VENTED USING THEAPPROPRIATE NAPOLEON VENT KITS. SEE
OWNERS INSTALLATION MANUALFOR VENTING SPECIFICS. PROPER REINSTALLATIONAND
RESEALING IS NECESSARYAFTER SERVICING THE VENT-AIR INTAKE SYSTEM. L'APPAREILDOIT
EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE ANAPOLEON. REFERER
AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE. IL EST
IMPORTANT DE BIEN REINSTALLER ET RESCELLER L'EVENT APRESAVOIRASSURE LE MAINTIEN
DU SYSTEME DE PRISE D'AIR.
ELECTRICAL RATING / CLASSIFICATION: 115V 0.82AMP, 60HZ
OPTIONAL FAN KIT / ENSEMBLE DE VENTILATEUR FACULTATIF: GZ550-1KT
T
DI
.
L
BILE
N
RM
D
E
RIT
TITR
24
FR
E
TI
P
E
APP
I
EE,
D
E
RIT
NTR
AN
FA
TURE
LE
ITE
001659
WUSA
ANIFOLD PRESSURE:
PRESSION AU COLLECTEPRESSION A
MINIMUM SUPPLY PREMINIMUM
PRESSION D'ALIMENPRESSION
0-4500FT (0-1370-4500FT (0-13
ALIMENTATION REDUITE 18,000 BTLIMENTATION REDUITE 18,000 BT
IN
NTA
T
RER WITH THE APPLIANCE.H THE APPLIANCE.
DEUR D'ENCASTRE 22”DEUR D'ENCASTRE 22”
1
2
ROTECTEUR DE CONDUIT D’ÉVACUATIONR DE CONDUIT D’ÉVACUATION
HORIZONTALE MAXIMALE: 5". SEEMAXIMALE: 5". SEE
S. REFERER AU MANUEL D'INSTRUCS. REFERER AU MANUEL D'INS
AR
IN
HE
AND
2
E
AR
IN
HE
AND
4
AXIMAL
V
INIMAL
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.