7
W415-0827 / D / 08.10.12
2.4 RATING PLATE INFORMATION
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the appliance.
The rating label is located behind the control door and is chained to the appliance. DO NOT REMOVE. For
rating plate location, see “INSTALLATION OVERVIEW” section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
A2"
B5"
C2"
W385-0373 / G
NOT FOR USE WITH SOLID FUEL
GDS26
GDS26N
CERTIFIED UNDER / HOMOLOGUE SELON LES NORMES: ANSI Z21.50b-2009&6$b-2009 VENTED GAS FIREPLACE / FOYERAU GAZ AVEC EVACUATION.
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG)
PRESSION AU COLLECTEUR: 3.5" D'UNE
COLONNE D'EAU(GN)
MIN SUPPLY PRESSURE: 4.5" W.C.(NG)
PRESSION D'ALIMENTATION MIN: 4.5" D'UNE
COLONNE D'EAU (GN)
MAX. SUPPLY PRESSURE: 7" W.C. (NG)
PRESSION D'ALIMENTATION MAX: 7" D'UNE
COLONNE D'EAU (GN)
MANIFOLD PRESSURE: 10 INCHES W.C.(LP)
PRESSION AU COLLECTEUR: 10" D'UNE
COLONNE D'EAU (P)
MIN SUPPLY PRESSURE: 11" W.C. (LP)
PRESSION D'ALIMENTATION MIN: 11" D'UNE
COLONNE D'EAU (P)
MAX. SUPPLY PRESSURE: 13" W.C. (LP)
PRESSION D'ALIMENTATION MAX: 13" D'UNE
COLONNE D'EAU (P)
0-4500ft
25,000 BTU/h
17,000 BTU/h
ALTITUDE / ELEVATION
INPUT / ALIMENTATION
REDUCED INPUT /
ALIMENTATION REDUITE
CAUTION: FOR USE WITH GLASS DOORS
CERTIFIED WITH THIS UNIT ONLY.
WARNING: DO NOTADDANY MATERIAL TO
THEAPPLIANCE, WHICH WILL COME IN CONTACT
WITH THE FLAMES, OTHER THAN THAT SUPPLIED
BY THE MANUFACTURER WITH THE APPLIANCE.
THIS VENTED GAS FIREPLACE HEATER IS NOT
FOR USE WITHAIR FILTERS.
ELECTRICAL RATING: BLOWER KIT GS67, 115V
0.5AMP 60HZ THEAPPLIANCE MUST BE VENTED
USING THEAPPROPRIATE WOLF STEEL VENT
KITS. SEE OWNERS INSTALLATION MANUALFOR
VENTING SPECIFICS. MINIMUM AND MAXIMUM
VERTICALVENT LENGTHSARE 3 FEETAND 40
FEET RESPECTIVELY.
MINIMUMAND MAXIMUM HORIZONTAL VENT
LENGTHS ARE 10 INCHESAND 20 FEET
RESPECTIVELY. PROPER REINSTALLATIONAND
RESEALING IS NECESSARYAFTER SERVICING
THE VENT-AIR INTAKE SYSTEM.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL:
VENT TOP 2" TO CEILING FROM
VENT BOTTOM 1" STOVE TOP 12”
VENT SIDES 1"
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILSE AVEC CET APPAREIL
EVENT SUPERIEUR 2" ENTRE LE DESSUS
DU FOYER
EVENT INFERIEUR 1" ET LE PLAFOND 12”
COTES DE L'EVENT 1"
A2”
B5”
C2"
LES LONGUEURS HORIZONTALES MINIMALES ET
MAXIMALES SONT 10 POUCES ET 20 PIEDS
RESPECTIVEMENT.
IL EST IMPORTANT DE BIEN REINSTALLER ET
RESCELLER L'EVENTAPRESAVOIR ASSURE LE
MAINTIEN DU SYSTEME DE PRISE D'AIR.
DEGAGEMENTS MINIMAUX DES MATERIAUX
COMBUSTIBLES:
SERIAL NUMBER / NO. DESERIE
0-4500ft
25,000 BTU/h
20,000 BTU/h
CDVS26N GDS26P CDVS26P
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
DIRECT VENT VENTED GAS FIREPLACE HEATER. APPROVED FOR BEDROOM, BATHROOM
& BEDSITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF
INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES
GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE
MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR,
PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD
FOR FIRE SAFETY CRITERIAFOR MANUFACTURED HOME INSTALLATIONS, SITES
AND COMMUNITIES, ANSI / NFPA 501A.
FOYER À GAZ VENTILÉS À ÉVACUATION DIRECTE. HOMOLOGUE POUR INSTALLATION
DANS UNE CHAMBRE A COUCHER, UNE SALLE DE BAIN ET UN STUDIO.APPROPRIE
POUR INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLATION CONFORME
AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE MAISONS MOBILES
EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME
DE SECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24
CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT
ETRE APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE DE
MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS
LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA
501A.
9700539 (WSL) 4001657 (NGZ)
4001658 (NAC) 4001659 (WUSA)
ATTENTION: UTILISER AVEC LES PORTES
VITREES HOMOLOGUEES SEULEMENTAVEC CETTE
UNITE.
AVERTISSEMENT: N'AJOUTEZ PASACET
APPAREIL AUCUN MATERIAU DEVANT ENTRER EN
CONTACT AVEC LES FLAMMES AUTRE QUE CELUI
QUI EST FOURNIAVEC CET APPAREIL PAR LE
FABRICANT.
CE FOYER À GAZ VENTILÉS NE DOIT PAS ÊTRE
UTILISÉ CONJOINTEMENTAVEC DES FILTRES ÀAIR.
CLASS.: SOUFFLERIE GS67, 115V 0.5AMP
60HZ L'APPAREIL DOIT EVACUER SES GAZ EN
UTILISANT L'ENSEMBLE D'EVACUATION PROPREA
WOLF STEEL. REFERERAU MANUEL
D'INSTALLATION DE PROPRIETAIRE POUR
L'EVACUATION PRECISE. LES LONGUEURS
VERTICALES MINIMALES ET MAXIMALES SONT 3
PIEDS ET 40 PIEDS RESPECTIVEMENT.
E APPLIQUEE, SE REFERER A L