7
W415-0547 / G / 12.15.10
2.4 RATING PLATE INFORMATION
A4"
B2"
C2"
W385-0330 / E
NOT FOR USE WITH SOLID FUEL
GDS/CDVS25
GDS25N
MODEL
CERTIFIED UNDER / HOMOLOGUE SELON LES NORMES: CSA2.33-2009, ANSI Z21.88-2009 VENTED GAS FIREPLACE HEATER / FOYER DE CHAUFFAGEAU GAZ AVEC EVACUATION.
APPROVED FOR BEDROOM, BATHROOM & BEDSITTING ROOM INSTALLATION. SUITABLE
FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITHTHE CURRENT
STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADAOR IN
THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND SAFETY
STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE
USE THE STANDARD FOR FIRE SAFETY CRITERIAFOR MANUFACTURED HOME
INSTALLATIONS, SITESAND COMMUNITIES,ANSI / NFPA 501A.
HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBREACOUCHER, UNE SALLE
DE BAIN ET UN STUDIO.APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI
SON INSTALLATION CONFORMEAUX EXIGENCES DE LANORME CAN/CSAZ240MH SERIE
DE MAISONS MOBILES EQUIPEESAU GAZ, EN VIGUEUR AU CANADAOUAUX ETATS-UNIS
DE LANORME DE SECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREES,
TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS
NE PEUT ETREAPPLIQUEE, SE REFERERA LANORME RELATIVE AU CRITERE
DE MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS
LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES,ANSI/NFPA 501A.
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG)
PRESSION AU COLLECTEUR: 3.5" D'UNE
COLONNE D'EAU(GN)
MIN SUPPLY PRESSURE: 4.5" W.C.(NG)
PRESSION D'ALIMENTATION MIN: 4.5" D'UNE
COLONNE D'EAU (GN)
MAX. SUPPLY PRESSURE: 7" W.C. (NG)
PRESSION D'ALIMENTATION MAX: 7" D'UNE
COLONNE D'EAU (GN)
MANIFOLD PRESSURE: 10 INCHES W.C.(LP)
PRESSION AU COLLECTEUR: 10" D'UNE
COLONNE D'EAU (P)
MIN SUPPLY PRESSURE: 11" W.C. (LP)
PRESSION D'ALIMENTATION MIN: 11" D'UNE
COLONNE D'EAU (P)
MAX. SUPPLY PRESSURE: 13" W.C. (LP)
PRESSION D'ALIMENTATION MAX: 13" D'UNE
COLONNE D'EAU (P)
AFUE: 64%
2000-4500ft
22,000 BTU/h
16,000 BTU/h
GDS25P
MODEL
0-2000ft
23,000 BTU/h
16,000 BTU/h
ALTITUDE / ELEVATION
INPUT / ALIMENTATION
REDUCED INPUT /
ALIMENTATION REDUITE
FOR USE WITH GLASS DOORS CERTIFIED WITH
THIS UNIT ONLY.
WARNING: DO NOTADDANY MATERIAL TO THE
APPLIANCE, WHICH WILL COME IN CONTACT
WITH THE FLAMES, OTHER THANTHAT SUPPLIED
BY THE MANUFACTURER WITH THE APPLIANCE.
ELECTRICAL RATING: 115V 1.5AMP 60HZ
THEAPPLIANCE MUST BE VENTED USING THE
APPROPRIATE WOLF STEEL VENT KITS. SEE
OWNERS INSTALLATION MANUALFOR VENTING
SPECIFICS. MINIMUM AND MAXIMUM VERTICAL
VENT LENGTHSARE 3 FEETAND 40 FEET
RESPECTIVELY.
MINIMUMAND MAXIMUM HORIZONTAL VENT
LENGTHSARE 10 INCHES AND 20 FEET
RESPECTIVELY. PROPER REINSTALLATIONAND
RESEALING IS NECESSARYAFTER SERVICING
THE VENT-AIR INTAKE SYSTEM.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL:
VENT TOP 2" TO CEILING FROM
VENT BOTTOM 1" STOVE TOP 48”
VENT SIDES 1"
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE. ONTARIO L4M 4Y8 CANADA
UTILISERAVEC LES PORTES VITREES
HOMOLOGUEES SEULEMENTAVEC CETTE
UNITE.
AVERTISSEMENT: N'AJOUTEZ PAS ACET
APPAREIL AUCUN MATERIAU DEVANT
ENTRER EN CONTACT AVEC LES FLAMMES
AUTRE QUE CELUI QUI EST FOURNIAVEC
CETAPPAREIL PAR LE FABRICANT.
CLASS.: 115V 1.5AMP 60HZ L'APPAREIL
DOIT EVACUER SES GAZ EN UTILISANT
L'ENSEMBLE D'EVACUATION PROPREA
WOLF STEEL. REFERERAU MANUEL
D'INSTALLATION DE PROPRIETAIRE POUR
L'EVACUATION PRECISE. LES LONGUEURS
VERTICALES MINIMALES ET MAXIMALES
SONT3 PIEDS ET 40 PIEDS
RESPECTIVEMENT.
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILSE AVEC CET APPAREIL
EVENT SUPERIEUR 2" ENTRE LE DESSUS
DU FOYER
EVENT INFERIEUR 1" ET LE PLAFOND 48”
COTES DE L'EVENT 1"
A4"
B2"
C2"
LES LONGUEURS HORIZONTALES MINIMALES ET
MAXIMALES SONT 10 POUCES ET 20 PIEDS
RESPECTIVEMENT.
IL ESTIMPORTANT DE BIEN REINSTALLER ET
RESCELLER L'EVENTAPRESAVOIRASSURE LE
MAINTIEN DU SYSTEME DE PRISE D'AIR.
DEGAGEMENTS MINIMAUX DES MATERIAUX
COMBUSTIBLES:
SERIAL NUMBER / NO. DESERIE
0-2000ft
24,500 BTU/h
19,000 BTU/h
2000-4500ft
20,000 BTU/h
14,000 BTU/h
AFUE: 64%
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to the
model, venting and gas type of the unit.
For rating plate location, see “INSTALLATION OVERVIEW” section.
This illustration is for referece only. Refer to the rating plate on the appliance for accurate information.
MOBILES EQUIPEESAU GAZ, E
ARANCE TO COMBUSTIBLE MATER