Nederman Airflow Alarm EX 40 User manual

Airow monitoring and measuring
Airow Alarm Kit
2130059(05)2018-11-27
www.nederman.com
ALARM ON
POWER
FAILURE
User manual
Original user manual
EN USER MANUAL
Translaon of original user manual
DA BETJENINGSVEJLEDNING
DE BEDIENUNGSANLEITUNG
ES MANUAL DE INSTRUCCIONES
PL INSTRUKCJA UŻYTKOWANIA
SV ANVÄNDARMANUAL


Airow Alarm Kit
3
Declaraon of conformity ................................................................................................ 4
Figures .................................................................................................................................................................. 6
English ...............................................................................................................................................................11
Dansk ..................................................................................................................................................................21
Deutsch ...........................................................................................................................................................31
Español ............................................................................................................................................................41
Polski ................................................................................................................................................................... 51
Svenska ...........................................................................................................................................................61

Airow Alarm Kit
4
Declaraon of conformity
Declaraon of conformity
We, AB Ph. Nederman & Co., declare under our sole responsibility that the
Nederman product:
Airow Alarm Kit (Part No. **, and stated versions of **) to which this
declaraon relates, is in conformity with all the relevant provisions of the
following direcves and standards:
Direcves
2014/35/EU, 2014/30/EU, 2011/65/EU.
Standards
EN 60730-1:2012, EN 61000-6-3:2007, EN 61000-6-1:2007.
The name and signature at the end of this document, is the person responsible
for both the declaraon of conformity and the technical le.
English
EN
Konformitätserklärung
Wir, AB Ph. Nederman & Co., erklären in alleiniger Verantwortung, dass das
Nederman Produkt
Airow Alarm Kit (Art.-Nr. **, und bauartgleiche Versionen **), auf welches sich
diese Erklärung bezieht, mit allen einschlägigen Besmmungen der folgenden
Richtlinien und Normen übereinsmmt:
Richtlinien
2014/35/EU, 2014/30/EU, 2011/65/EU.
Normen
EN 60730-1:2012, EN 61000-6-3:2007, EN 61000-6-1:2007.
Name und Unterschri am Dokumentende geben diejenige Person an, die für
die Konformitätserklärung und die technische Dokumentaon verantwortlich ist.
Deutsch
DE
Overensstemmelseserklæring
AB Ph. Nederman & Co. erklærer som eneansvarlige, at følgende produkt fra
Nederman:
Airow Alarm Kit (Arkel nr. **, og erklærede versioner af **), som denne
erklæring vedrører, er i overensstemmelse med alle de relevante bestemmelser
i de følgende direkver og standarder:
Direkver
2014/35/EU, 2014/30/EU, 2011/65/EU.
Standarder
EN 60730-1:2012, EN 61000-6-3:2007, EN 61000-6-1:2007.
Navnet og underskrien sidst i dee dokument lhører den person, der
er ansvarlig for såvel overensstemmelseserklæringen som den tekniske
dokumentaon.
Dansk
DA
Declaración de Conformidad
Nosotros, AB Ph. Nederman & Co., declaramos bajo nuestra única
responsabilidad que el producto Nederman:
El producto, Airow Alarm Kit (Ref. nº **, y las versiones basadas **),, al que
hace referencia esta declaración, cumple con todas las disposiciones aplicables
de las Direcvas y normas que se indican a connuación:
Direcvas
2014/35/EU, 2014/30/EU, 2011/65/EU.
Normas
EN 60730-1:2012, EN 61000-6-3:2007, EN 61000-6-1:2007.
El nombre y rma que guran al nal de este documento corresponden a la
persona responsable, tanto de la declaración como de la cha técnica.
Español
ES
Deklaracja zgodności
Firma AB Ph. Nederman & Co. niniejszym deklaruje z pełną odpowiedzialnością,
że oferowany przez nią produkt FilterBox (nr części ** i oznaczenie wersji **),
do którego odnosi się ta deklaracja, spełnia wszystkie odpowiednie wymagania
poniższych dyrektyw i norm:
Dyrektywy
2014/35/EU, 2014/30/EU, 2011/65/EU.
Normy
EN 60730-1:2012, EN 61000-6-3:2007, EN 61000-6-1:2007.
Na końcu niniejszego dokumentu znajdują się imię, nazwisko oraz podpis osoby
odpowiedzialnej za deklarację zgodności oraz dokumentację techniczną.
Polski
PL
Försäkran om överensstämmelse
Vi, AB Ph. Nederman & Co., försäkrar under eget ansvar a Nederman-
produkten:
Airow Alarm Kit (arkelnr **, och fastställda versioner av **.), som denna
försäkran avser, överensstämmer med alla llämpliga bestämmelser i följande
direkv och standarder:
Direkv
2014/35/EU, 2014/30/EU, 2011/65/EU.
Standarder
EN 60730-1:2012, EN 61000-6-3:2007, EN 61000-6-1:2007.
Namn och namnteckningen i slutet av dea dokument är den person som
ansvarar både för försäkran om överensstämmelse och för den tekniska
dokumentaonen.
Svenska
SE
**
40780434, 40780435, 40780436, 40780437, 40780438, 40780439, 40780440, 40780441
AB Ph. Nederman & Co.
P.O. Box 602
SE-251 06 Helsingborg
Sweden
Frank Christensen
VP Operaons EMEA
2018-11-27

Airow Alarm Kit
5

Airow Alarm Kit
6
www.nederman.com
ALARM ON
POWER
FAILURE
1
Figures
5
2
3
4
1
6

Airow Alarm Kit
7
PSU2L
PSU2N
PSU1L
PSU1N
Alarm NO
Alarm C
Alarm NC
1 5 6 7
Output
12 VDC
Fan Constant
85-230VAC Power
Input
85-230 VAC
2 3 4
P-SW
P-SW
GND Out Alarm
+12V Out Alarm
8
3 2
OPS Alarm Flash
Open = Alarm
9 10 11
Output
12 VDC
Input
85-230 VAC
Relay in alarm
state GND_DC +12V
Black
Red
+
−
85- 230 VAC
fan on 85- 230 VAC
Power
Central
surveillance
COM
2 NO
1 NC
P
3
1 2 3 4 5
2

Airow Alarm Kit
8
Airflow Alarm
Pressure switch
Airflow alarm and pressure switch mounted
3
P
V
PS
V
-10%
Alarm limit setting
PS
90%-95%
4

Airow Alarm Kit
9
NO
5 6 7
Not
used
Not
used
Not
used
Not
used
Not
used
OFF ON
Open/
Closed
OFF
Fan OFF
NO
5 6 7
ON OFF
ON ON (Closed)
Normal
operating
mode
Flow = OK
NC
5 6 7
ON ON
(Open)
ON
OFF
Low flow
NC
5 6 7
ON OFF ON
ON
(Closed)
Power failure
NC
5 6 7
NC
5 6 7
OFF
Battery
used
OFF OFF OFF
OFF
ON ON
OFF
(Open)
Low flow
power failure
Power OFF
PSU2
Fan
PSU1
Constant
P-SW Alarm OutAlarm LEDs Alarm Status Relay
Internal
battery
5

Airow Alarm Kit
10

Airow Alarm Kit
11
EN
English
1 Preface ..............................................................................................................................................................................12
2 Safety .................................................................................................................................................................................12
3 Descripon .....................................................................................................................................................................12
3.1 Intended use ..................................................................................................................................................12
3.2 Funcon ............................................................................................................................................................12
3.3 Main parts .......................................................................................................................................................13
3.3.1 Airow Alarm - Control box .......................................................................................................13
3.4 Technical data ................................................................................................................................................13
4 Installaon ......................................................................................................................................................................14
4.1 Control box......................................................................................................................................................14
4.2 Electrical connecons ...............................................................................................................................14
4.3 Monitoring point .........................................................................................................................................14
4.4 Startup ...............................................................................................................................................................15
4.4.1 Adjustment .........................................................................................................................................15
5 Use ......................................................................................................................................................................................16
5.1 Airow Alarm - Control box LEDs .......................................................................................................16
6 Maintenance .................................................................................................................................................................17
6.1 Spare parts ......................................................................................................................................................17
7 Recycling ..........................................................................................................................................................................17
8 Troubleshoong Assistance ..................................................................................................................................18
9 Control protocol for Airow Alarm ...................................................................................................................19
Figures ................................................................................................................................................................................. 6
Table of contents

Airow Alarm KitEN
12
1 Preface
Read this manual carefully before installaon, use and service of this product.
Replace the manual immediately if lost. Nederman reserves the right, without
previous noce, to modify and improve its products including documentaon.
This product is designed to meet the requirements of relevant EU direcves.
To maintain this status, all installaon, maintenance and repair is to be done
by qualied personnel using only original spare parts. Contact the nearest
authorized distributor or Nederman for advice on technical service and
obtaining spare parts. If there are any defecve or missing parts when the
product is delivered, nofy the carrier and the local Nederman representave
immediately.
2 Safety
This document contains important informaon that is presented either as a
warning, cauon or note:
WARNING! Risk of personal injury.
Warnings indicate a potenal hazard to the health and safety of personnel,
and how that hazard may be avoided.
CAUTION! Risk of equipment damage.
Cauons indicate a potenal hazard to the product but not to personnel, and
how that hazard may be avoided.
NOTE! Notes contain other informaon that is important for personnel.
3 Descripon
3.1 Intended use
The Airow Alarm monitors pressure condions in a suitable duct.
3.2 Funcon
The Airow Alarm is connected to a fan starter so that Airow Alarm starts to
monitor automacally and simultaneously with the fan. The alarm is acvated
when the stac pressure in the duct is outside preset limits.
The Airow Alarm can either monitor one parcular exhaust point at a
workplace, or a group of workplaces connected to a single air duct leading to
the fan.

Airow Alarm Kit
13
EN
3.3 Main parts
See gure 1. The Airow alarm kit consists of:
1. Airow Alarm - Control box.
2. Pressure switch. Available as a standard model, and an ATEX approved
model for zone 2/22.
3. Protecon lter.
4. Rubber ng.
5. Flashlight (oponal).
6. Cable gland (oponal).
3.3.1 Airow Alarm - Control box
See gure 2. The Airow Alarm contains a terminal block that includes
connecons to:
1. 85-230 VAC power supply (Phase 1). Signal in from fan to acvate
monitoring.
2. 85-230 VAC power supply (Phase 2). Power in to Airow Alarm.
3. External connecon to central surveillance (Oponal).
4. Pressure switch.
5. External Airow Alarm devices such as a ashlight.
NOTE! Drill an extra hole and install a cable gland if the Control box is to be
directly connected to both a ashlight and to central surveillance. See gure
1(6).
3.4 Technical data
Part Descripon
Supply PSU1 85 - 230V AC, 50-60Hz, max. 13AFuse
Supply PSU2 85 - 230V AC, 50-60Hz, max. 13AFuse
Pressure switch External contact must be below 100 Ohm
12 V DC out alarm 12 V DC maximum 200 mA
Alarm relay Maximum 8A AC1 250 VAC
9V baery 6LR61, non rechargeable
Fuse 5 x 20 T500mA
Dimensions 120 mm x 170 mm x 60 mm
Operang temperature 0 - 50 °C
IP Class Control box IP54
IP Class Pressure Switch Standard IP54
IP Class Pressure Switch ATEX IP65, ATEX model approved for zone 2/22.

Airow Alarm KitEN
14
4 Installaon
Installaon, repair and maintenance work is to be carried out by qualied
personnel using only original Nederman spare parts. Contact your nearest
authorized distributor or Nederman for advice on technical service.
4.1 Control box
NOTE!
• The Airow Alarm control box and ashlight must be installed outside the
ATEX classied zone.
• The oponal ashlight should be situated at a locaon visible from the
workplace(s) monitored. See gure 3.
Before starng installaon, an unused volts-free contact from the fan starter
should be wired through to the Fan ON posion.
The electrical enclosure should be mounted near the workplace so that the
alarm LEDs can be clearly seen noted from the operator’s working place. See
gure 3.
If the operator does not have a permanent place or where several working
places are supervised by one alarm, one ashlight should be installed so that
the alarm may be clearly seen from the operator’s working places.
4.2 Electrical connecons
WARNING! Risk of personal injury.
Work with electric equipment is to be carried out by a qualied electrician.
See gure 2 for the wiring diagram, and cabling for terminals for the Airow
Alarm.
Electrical connecons between components should comply with current
naonal regulaons.
4.3 Monitoring point
WARNING! Risk of personal injury.
• If the there is ammable dust or gas present, turn o the fan.
• Eliminate ignion sources such as heat or sparks.
• Wear a dust mask.
NOTE! A non ATEX approved pressure switch must be installed outside of an
ATEX classied zone.
NOTE! Any screws or other xings used into the air duct must not cause any
collecon of dust/chips. If the pressure switch housing is conducve, there
needs to be contact between the pressure switch housing and the metal duct
or ground.
The monitoring point is selected as follows:

Airow Alarm Kit
15
EN
When monitoring Locaon
One single workplace Between dust extracon point, such as a sucon hood, and a
connecon to the duct system.
A group of workplaces Close to the connecon point farthest away from the fan. See gure
3.
The pressure switch can be mounted on the air duct.
NOTE! When drilling in air ducts, safety regulaons must be kept in mind.
The hose is connected to the hose connecon on the pressure switch marked
with a minus (-) sign. Nothing is connected to the hose connecon marked
plus (+) atmospheric pressure.
4.4 Startup
When the fan starts, the alarm is acvated, and the ALARM LED remains lit
unl the required pressure is reached. The ON LED is also lit.
4.4.1 Adjustment
1. A suitable part of the duct is selected, and a hole for the protecon lter
is drilled close to the last connecon point. See secon 4.Installaon
above.
2. The maximum airow according to the order acknowledgement,
technical specicaons etc. must be determined and the corresponding
air velocity calculated.
3. The air velocity is measured with the planned number of extracon
points open. If the airow is larger than (V0), reduce the airow. For
example, this can be done by inserng a plate in front of the fan outlet
ange to reduce the airow unl the airow (V0) planned is reached.
4. At this airow, the stac pressure at the monitoring point (PS0) is
measured, and the pressure switch is set 10% lower, see gure 4.
If the pressure switch measuring range does not cover the seng
value required, the pressure switch is replaced by one with a relevant
measuring range.
5. The main airow is reduced slowly by inserng the plate in the fan outlet
ange unl the alarm is released.
6. The air velocity is measured and the airow is calculated. If it is between
90 and 95% of the airow specied, the adjustment has been completed.
7. If the airow is less than 90% of the airow specied, set pressure switch
5% higher, and repeat item 5.
8. If the airow is higher than 95% of the airow specied, set pressure
switch 5% lower, and repeat item 5. It might be necessary to remove the
plate in front of the fan outlet ange.

Airow Alarm KitEN
16
9. When the adjustment has been completed, note the following in the
control protocol, see secon 9.ControlprotocolforAirowAlarm:
–Monitoring point
–Workplaces covered by the monitoring
–Adjustment date
–Adjusted by
–Airow planned V0
–Stac pressure, PS0 at V0
–Alarm limit seng
Make and keep a copy of the control protocol for Nederman service
technician.
5 Use
WARNING! Risk of personal injury.
If there is work with hazardous substances that are assigned mandatory
exposure limits and there is a problem with the Airow alarm, stop work
immediately and x the problem.
The Airow alarm limit has been set according to the arrangement and
operang parameters of the parcular extracon system. Normally, the
Airow Alarm limit will be at 90% airow per workplace, 100% being the
airow specied. When monitoring a group of workplaces, the airow per
workplace is an average value. The Airow Alarm limit seng is found in the
control protocol for the exhaust alarm.
The Airow Alarm begins monitoring as soon as the fan starter is acvated,
and monitors pressure condions in a suitable duct. The alarm is acvated
when the stac pressure in the duct is outside the preset limits.
In the event of an alarm, the red ALARM LED on the Airow Alarm control box
will be lit, and any external connected alarm devices will be acvated. Stop
work at once, nd the cause of the alarm, and x the problem.
When the cause of the alarm has been xed, and the stac pressure in the
duct returns to within the normal range, the alarm will turn o automacally,
and the Airow Alarm will resume monitoring.
During normal operaon, the green ON LED should be lit, which indicates that
the 230 V source works. If the green ON LED is not lit during normal operaon,
one of the 230 V sources is defecve and the red POWER FAILURE LED will
also be ashing. The 230 V source must be xed and reconnected at once.
If changing a fuse cannot solve the problem, contact a Nederman service
technician for assistance. See also gure 5.
5.1 Airow Alarm - Control box LEDs
Below is a descripon of the top of the Airow Alarm. See gures 1 and 5:
Descripon
ALARM Red Too low airow in the system.
POWER FAILURE Red Problem with electrical supply to unit.

Airow Alarm Kit
17
EN
Descripon
ON Green Unit acve/standby. Airow Alarm is monitoring.
6 Maintenance
Installaon, repair and maintenance work is to be carried out by qualied
personnel using only original Nederman spare parts. Contact your nearest
authorized distributor or Nederman for advice on technical service.
WARNING! Risk of personal injury.
Before restarng, close and reconnect guards, doors/hatches, etc.
When any defecve components are found, they should be replaced, and
the unit re-adjusted by a Nederman service technician. If the Airow Alarm
Control box is defecve, it must be replaced.
Maintenance Monthly/Operang Hours Interval
Check that the green ON LED on the controller is lit
durning normal operaon.
Daily
Check correct startup sequence. Airow Alarm must be
released immediately and stay acve unl the fan has
reached normal speed and vacuum has been built up
in the system.
Daily
Check the hose and the protecon lter between the
pressure switch and the air duct for clogging. Blow air
to clean if necessary.
Every 3 months or 1,000 hours
Check the Airow Alarm limit seng (*) Every 12 months (annually)
(*) To be performed by qualied personnel.
6.1 Spare parts
Contact your nearest authorized distributor or Nederman for advice
on technical service or if you require help with spare parts. See also
www.nederman.com.
When ordering spare parts always state the following:
• Part number and control number (see the product idencaon plate).
• Detail number and name of the spare part (see www.nederman.com).
• Quanty of the parts required.
7 Recycling
The product has been designed for component materials to be recycled.
Its dierent material types must be handled according to relevant local
regulaons. Contact the distributor or Nederman if uncertaines arise when
scrapping the product at the end of its service life.
If the Airow Alarm needs to be removed, the sensor hole in the duct should
be sealed. If hazardous dust is likely to be present, suitable precauons must
be taken such as the use of goggles, dust mask and gloves.

Airow Alarm KitEN
18
8 Troubleshoong Assistance
All troubleshoong and similar acvies should only be performed by skilled
personnel with knowledge of the plant funcon and construcon, and in
accordance with safety regulaons, maintenance instrucons, etc.
Fault Possible Cause Soluon
Alarm occurring briey at
startup
Fan starts slowly. Alarm is acvated for a maximum of 60 seconds during startup.
The alarm at startup may be considered as a daily funcon check.
Alarm occurring
periodically
• Extracon system overloaded by too many
exhaust points being opened at the same
me.
• Extracon system overloaded by a bad
connecon on one or more exhaust points.
• Protecon lter regeneraon occurs too
infrequently.
• Airow alarm limit set too high.
• Shut unused exhaust points.
• Limit the number of exhaust points to the capacity of the plant.
• Establish automac dampers and connect control with max.
limit.
• Extend extracon system capacity.
• Re-establish correct connecons such as smaller hose diameter,
longer hoses, hoses without holes, etc.
• For plants with lter regeneraon during operaon: Reduce
me interval between regeneraon / decrease cleaning start
level.
• For plants with regeneraon in breaks: Stop the plant more
frequently or establish regeneraon during operaon.
• Call Nederman service technician.
Alarm acvated
permanently or for
extended periods.
• Extracon system capacity less than before.
• Extracon system overloaded by having too
many exhaust points connected.
• Extracon system overloaded by defecve
connecon on one or more exhaust points.
• The hose assembly between air duct and
pressure switch clogged.
• Airow Alarm defecve.
• Clean or replace clogged protecon lter in the extracon
system.
• Clean clogged air ducts / fan.
• Replace exible connecons at the fan.
• Replace defecve V-belt drives / fan motor.
• Fix or replace defecve fan.
• Shut unused exhaust points.
• Limit number of exhaust points to plant capacity.
• Establish automac dampers and connect control with max.
limit.
• Extend extracon system capacity.
• Re-establish correct connecons, such as smaller hose
diameter, longer hoses, hoses without holes etc.
• Check the hose and the protecon lter between the pressure
switch and the air duct for clogging. Blow air to clean if
necessary.
• Call Nederman service technician.
Alarm is not acvated in
connecon with startup
or when it is supposed to
be acvated.
• No power supply.
• The hose/protecon lter is clogged.
• Hose assembly for the pressure switch
clogged.
• Pressure switch defecve.
• Change the defecve fuse.
• Have an electrician check the wiring system.
• Disconnect the pressure switch, and clean the hose and
protecon lter. Reconnect the pressure switch.
• Check the hose and the protecon lter between the pressure
switch and the air duct for clogging. Blow air to clean if
necessary.
• Call Nederman technician.
• See also gure 5.
The POWER FAILURE LED
is not lit.
• A connecon to the voltage supply has
been cut o.
• Baery backup is defecve.
• See gure 5.
• Change the fuse.
• Have an electrician check the voltage supply.
• Replace the baery.

Airow Alarm Kit
19
EN
9 Control protocol for Airow Alarm
Copy the control protocol, ll it in and save it as a service record.
NOTE! If a value is outside its accepted level, or a result is incorrect or missing,
x the problem before inial startup and normal operaon.
Monitoring point Workplaces
covered by the
monitoring
Adjustment date Adjusted by Airow planned
V0
Stac vacuum
at V0
Alarm limit seng

Airow Alarm KitEN
20
Monitoring point Workplaces
covered by the
monitoring
Adjustment date Adjusted by Airow planned
V0
Stac vacuum
at V0
Alarm limit seng
Company
Date Sign
This manual suits for next models