1.Purpose
The executive device Radio 8113 IP65 is designed to control
roller shutters, roller blinds, gate and barrier control units, sun
blinds, as well as lighting devices and with any other electric
load with a current consumption of up to 3 A using the
remote controls of the Radio series.
187-253/50
20
3 (at cos=1)
1
433.05-434.79
1000
80x80x50
from -30 to +50
0,75
IP65
2.Specifications
Supply voltage range, V~/Hz
Consumption current, mA, not more than
Maximum allowable switching current, A
Number of controlled electric drives
Operating frequency range, MHz
Number of recordable codes of remote controls
Overall dimensions, mm
Operation temperature range, °С
Section of interconnecting wires, mm2
Degree of enclosure protection
Protection class against electric shock II
The product is not intended for installation and operating in explosion hazard and fire
hazardous zones and does not require the protective earth.
3. Peculiarities
- availability of potential-free contact for connection to automation of other manufacturers;
- control using the remote controls of the Radio series;
- retransmission of commands from dynamic remote controls;
- auto closing timer for rolling gates;
- emergency control of roller shutters, rolling gates.
4. Connection
Use wires with a cross-section of at least 0.75 mm2in double insulation to connect the device
to the network and to the electric drive.
It is prohibited to use mounting wires and cables with polyethylene insulation or sheath.
It is prohibited to install the device at a distance less than 1 m from heating devices.
The holes in feedthrough plate should be punctured using a tool of smaller diameter than the
input cable.
It is prohibited to supply 220-230 V~ voltage to the terminals 8-15.
To consider 220 V~ as the nominal network voltage when delivered to Ukraine.
It is allowed to change the safeguard on the 5A rating when connecting the drives
with a current consumption more than 3 A.
5.Programming of remote controls
Action
Indication
1. Input the device in programming mode of remote controls (PM of remote controls)
Press and hold the programming button for more than 4 sec.Visual indicator blinks red.
2. Record the remote control channel in the memory of the device (PM of remote
controls)
Radio
8101-1M
a) in dynamic mode: press and hold the
remote control button for more than 2 sec.;
b) in static mode: press short the remote
control button (less than 1 sec.)
When recording the visual
indicator blinks short-long-
short green light.
If the remote control is
already recorded, the
indicator will flash green
shortly.
Radio
8101-2M
8101-4M
a) in dynamic mode: press and hold the
recordable remote control button, and press
short any other;
b) in static mode: press short the recordable
button.
Antenna
Safeguard
Power supply
220-230 V~
Fig. 1 Drive connection
Electric drive
Jumper 220-230 V~
Visual
indicator
Two-button
switch
“Programming” button
General/ground
Safety inputs
General/ground
Power supply + 12 V/200 mA

Radio
8101-5
1) choose the recordable channel by
pressing short the CH button. The channels
are switched circle-wise each time you
press;
2) record the channel by pressing short the
“STOP” button.
If the memory is full, the
indicator blinks yellow for
3 sec.
Radio
8152-50
Press short the programming button.
3. Delete the remote control channel from the memory of the device (PM of remote
controls)
Radio
8101-1M
a) in dynamic mode:
1) input the remote control in programming
mode: press the button 3 times in a row, and
hold it for more than 4 sec. when pressing
for the fourth time. The pressing interval
should not exceed 1 sec.;
2) delete the remote control: press and hold
the remote control button for more than
1 sec.
b) in static mode: press and hold the remote
control button for more than 1 sec.
The visual indicator of the
remote control blinks red in
programming mode.
When deleting the visual
indicator will flash long-
term and then will continue
to blink red.
Radio
8101-2M
8101-4M
a) in dynamic mode: press and hold the
button of erasable channel, and press any
other for more than 1 sec.;
b) in static mode: press and hold the button
of erasable channel for more than 1 sec.
The visual indicator will
flash long-term and then
will continue to blink red.
Radio
8101-5
1) choose the erasable channel by pressing
short the CH button. The channels are
switched circle-wise each time you press;
2) delete the selected channel: press and
hold the “STOP” button for more than 1sec.
Radio
8152-50
Press and hold the programming button for
more than 1 sec.
4. Delete channels of all remote controls from the memory of the device (PM of
remote controls)
Press and hold the programming button for more than
4 sec.
The visual indicator will
flash red for a long time
twice.
5. Output the device from the PM of remote controls
Press short the programming button.
The visual indication stops.
The device is automatically removed from the programming mode, if no
actions are performed with it during 32 sec.
6.Operation modes
The device has 4 operation modes:
Short command mode is used to connect the external automatics (fig. 2 and fig. 3). Command
time is 1,5 sec.
Roller shutter mode is used to control electric drives of roller shutters, roller blinds, sun
blinds. Command time can be installed up to 180 sec. Factory setting is 60 sec. (fig. 1).
Roller shutter mode with auto closing is used to control roller gates. Auto closing time can
be installed up to 240 sec. Factory setting is 20 sec.
Continuous command mode is used to control lightning and another load up to 3 A/690 W.
It is recommended to connect incandescent lamps not more than 220 W.
The command and auto closing time settings allow you to optimize the control of the roller
shutters. The command time is set in accordance with the size of the roller shutter curtain. The
auto closing timer is set according to the required waiting time for closing in the open position.
Auto closing timer is turned on after:
a) the time expiration of the “UP” command;
b) the stopping in an intermediate position upon a command from a remote control or a key
switch;
c) the unlocking the device using a safety sensor.
Power supply
220-230 V~
To install
the jumper
To delete
the jumper
Fig. 2 Connection to step-by-
step input
Fig. 3 Connection to separate
“OPEN” and “CLOSE” inputs
Gate and
barrier control
unit
Power supply
220-230 V~
Gate and barrier
control unit
To
delete
the
jumper

6.1. Change of operation mode, command time and auto closing time
Action
Indication
1. Input the device in programming mode of operation modes
1) input in the PM of remote controls: press and hold the
programming button for more than 4 sec.;
2) input in PM of operation modes: press and hold the
programming button for more than 1 sec. (up to yellow
flash).
1) visual indicator blinks
red;
2) visual indicator blinks
green for certain times.
2. Change the device operation mode
The modes are switched circle-wise each time you press
and hold the programming button for more than 1 sec. (up
to yellow flash).
Number of flashes:
1- short command mode;
2- roller shutter mode
(factory setting);
3- roller shutter mode with
auto closing;
4- continuous command
mode.
3. Change the command time (in the PM of operation mode)
The time setting is carried out only using connected key switch without the
fixation of pressed position.
1) to input repeatedly the device in the PM of operation
mode, if it is necessary;
2) to set the 2nd operation mode;
3) to install the roller shutter in the lowermost position by
pressing the “DOWN” button;
4) to start the time countdown by pressing shortly the “UP”
button;
5) to wait for 3-5 sec. and press the “DOWN” button when
the roller shutter is stopped in uppermost position. New
time will be recorded in the device memory.
The visual indication of the
second operation mode –
double green flashes.
4. Change the time of auto closing timer (in the PM of operation mode)
1) to input repeatedly the device in the PM of operation
mode, if it is necessary;
2) to set the 3rd operation mode;
3) to start the time countdown by pressing shortly the “UP”
button;
4) to press the “DOWN” button when the necessary time is
expired. New time will be recorded in the device memory.
The visual indication of the
third operation mode –
triple green flashes.
5. Reset to the factory setting (in the PM of operation mode)
1) to input repeatedly the device in the PM of operation
mode, if it is necessary;
2) press and hold the programming button for more than 4
sec.
The visual indicator will
flash yellow after 1 and 4
sec., and then it will
continue to blink double
green light.
6. Output the device from the programming mode
Press twice shortly the programming button.
The visual indication stops.
The device is automatically removed from the programming mode, if no
actions are performed with it during 32 sec.
7.Safety inputs
7.1. Connection of safety devices
The device can operate with the following safety devices:
- reed switch (fig. 4);
- optical sensors SIGNAL12 (fig. 5);
- infrared barrier with NO and NC contacts (fig. 6);
- device for group opening of roller shutters with NO and NC contacts (clause 6.2).
When the device is blocked by the sensor, the red visual indicator will flash continuously. The
device will be unavailable to control. In this situation, it is necessary to eliminate the obstacle
in the operation area of the sensor or to change the operation mode in accordance with the
connected sensor.
The device has 5 operation modes of safety inputs (PM of safety inputs) for the organization
of work with the safety elements.
Modes 1-4 determine the contact type of the infrared barrier (reed switch) and the response of
the device when sensors are blocked during the movement:
1. NO-sensor: when the device is closed, it will execute the “STOP” command.
2. NO-sensor (factory setting): when the device is closed, it will execute the “STOP”
and “UP” commands.
3. NC-sensor: when the device is opened, it will execute the “STOP” command.
4. NC-sensor: when the device is opened, it will execute the “STOP” and “UP”
commands.
When the IS15 insertion is deformed, the optical beam of the optical sensors SIGNAL12 is
interrupted, and the device always executes the “STOP” and “UP” commands. The response
does not depend on the selected mode (1-4). The “UP” command is executed only when the
sensor is blocked during the “DOWN” movement.
The fifth mode allows you to control groups of devices Radio 8113 IР65 through one dry
contact by applying / dumping power supply +12 V (cl. 6.2).

7.2. Group control of devices
You can use NO or NC contact type to control the devices.
A jumper between the contacts 13-15 allows you to invert the effect of the device on the roller
shutter.
Device Radio 8113 IР65 or another power supply can serve as a 12 V power supply.
For example, if you use the NC-contact, then this connection scheme will support the
monitoring of control line integrity. When a wire breaks, all roller shutters will raise/lower as
if the control contact is opened. It is necessary to set the 5th operation mode of the safety inputs
to implement this functionality (cl. 6.3).
Inadvertent activation is possible with a large length of the control line and
significant settings to it. Division of the control line into two with coupling of 12
V intermediate relay can serve as the solution of a problem. You should use the
power supply from different devices Radio 8113 IP65 for each line.
7.2.1. Control of group of devices, a jumper is not installed (fig. 7)
- when the contact is closed, the device will execute the “DOWN” command, the control from
the remote controls and key switch will be blocked;
- when the contact is opened, the device will execute the “UP” command, the control from the
remote controls and key switch will be available;
- after power re-supplying when the contact is opened, the device will execute the “UP”
command;
- after power re-supplying when the contact is closed, the device will execute the “DOWN”
command.
7.2.2. Control of group of devices, a jumper 13-15 is installed
- when the contact is closed, the device will execute the “UP” command, the control from the
remote controls and key switch will be available;
- when the contact is opened, the device will execute the “DOWN” command, the control from
the remote controls and key switch will be blocked;
- after power re-supplying when the contact is opened, the device will execute the “DOWN”
command;
- after power re-supplying when the contact is closed, the device will execute the “UP”
command.
Fig. 6 Connection of infrared barrier
Fig. 5 Connection of optical sensor SIGNAL12
Fig. 4 Connection of reed switch
Fig. 7 Variant of control without a jumper
Fig. 8 Variant of control with a jumper
+12 V - brown;
output -green;
general - white
12 V 12 V

7.3. Installation of operation mode of safety inputs
Action
Indication
1. Input the device in programming mode of safety sensor
1) input in the PM of remote controls: press and hold
the programming button for more than 4 sec.;
2) input in PM of operation modes: press and hold
the programming button for more than 1 sec.;
3) input in PM of safety sensor: press short the
programming button.
1) visual indicator blinks red;
2) visual indicator blinks green.
3) visual indicator blinks red for
certain times (cl. 2).
2. Change the operation mode of safety inputs
The modes are switched circle-wise each time you
press and hold the programming mode for more than
1 sec. (up to yellow flash).
Number of flashes:
1- NO –“STOP” command
(factory setting);
2- NO –“STOP-UP” command;
3- NC –“STOP” command;
4- NC –“STOP-UP” command;
5- control of group of devices.
3. Reset the operation mode of safety inputs to the factory setting
Press and hold the programming button for more than
4 sec.
Single red flash.
4. Output the device from the programming mode
Press shortly the programming button.
The visual indication stops.
The device is automatically removed from the programming mode, if no
actions are performed with it during 32 sec.
8.Retransmission
The retransmission function is necessary to increase the transmission distance of a remote
control signal in difficult reception conditions. Difficult conditions can be strong interference,
long distance, the presence of a large number of obstacles. For example, to control a group of
devices located on an object with difficult reception conditions, you need to record the remote
control in all devices and turn on the retransmission function on one or more of them. Devices
intended for retransmission are selected based on the size and characteristics of an object. As
a rule, the repeater should be located in the middle of the distance, between the most remote
control points of the receiver.
Only the dynamic code is retransmitted!
Do not turn on the retransmission without extreme necessity.
Do not turn on the retransmission on devices located nearby.
Do not turn on the retransmission on many devices. This can disturb to transmit
the second command of the remote control coming after a short period of time
(1-2 sec.).
Retransmission of remote control marking is carried out only together with the
control of power relay.
8.1. Turning on/off the retransmission function
Action
Indication
1. Input the device in programming mode of repeater from the standby-mode
Press and hold the programming button for more
than 8 sec.
Visual indicator blinks green for
certain times.
2. Change the operation mode of repeater
Turning on/off the retransmission mode is carried
out circle-wise each time you press and hold the
programming mode for more than 1 sec. (up to
yellow flash).
Number of flashes:
1- retransmission of command is off
(factory setting);
2- retransmission of command is on.
3. Output the device from the programming mode
Press shortly the programming button.
The visual indication stops.
The device is automatically removed from the programming mode, if no
actions are performed with it during 32 sec.
9.Device operation
The device can execute the following commands:
1. “UP”, “DOWN”, “STOP” - when controlling from the Radio 8101-5 remote control. If
during the movement of the roller shutter you press the button of the opposite direction and
hold it for more than 1 sec, the roller shutter will stop for a while and start moving in the
opposite direction.
2. “UP”, “DOWN”, “STOP” - when controlling by using the Radio 8101-2M mini-remote
controls, as well as the Radio 8152-50 timer.
3. “Step-by-step control” - when controlling by using the Radio 8101-1M, Radio 8101-4M
mini-remote controls.
In the “Roller shutter mode with auto closing” operation mode, the device can be blocked for
3 hours from the previously recorded remote control. To do this, press and hold the remote
control button for more than 4 seconds. It can be unlocked by pressing any remote control
button from which the device was blocked, or by pressing a button on the connected key switch.
10. Current maintenance
If during operation the device fault is detected it is necessary to disconnect the device from the
supply mains immediately and call maintenance personnel. Within the warranty period
servicing and repair are provided by the manufacturer dealer.
11. Storage and transportation, service life
The devices should be stored in packing at temperatures from +5°C to +40°C and relative
humidity of not more than 80% in heated and vented warehouses, in air-conditioned depots
without corrosive contaminants, conductible dust, acid and alkali vapors and gases causing
corrosion and insulation breakdown.

The devices should be transported packaged, in containers, closed railway cars, heated and air-
tight compartments of aircraft and holds and by trucks with rain and snow protection for any
distances at temperatures from -50°C to +50°C and relative humidity of 100% at 25°C.
Average service life is 5 years min.
12. Disposal
At the end of the service life the device is subject to disposal. The device does not pose a hazard
to human health and environment. The device does not contain any non-ferrous and precious
metals.
13. Manufacturer’s warranty
Guaranteed storage life is 6 months from the manufacturing date (the last 6 figures in the
product serial number, for example: 191117 –November 19, 2017).
Guarantee service life is 24 months from the date of sale.
With the note of sale absent –from the manufacturing date.
Warranty obligations cease in case of non-observance of operating conditions established by
the manufacturer and mechanical damage during operation. Warranty obligations do not cover
the case of failure to present the device passport.
1 pc
1 pc
14.Completeness
Executive device Radio 8113 IP65
Passport
Individual packing 1 pc
15. Acceptance certificate
Executive device Radio 8113 IP65(see serial number on the first page) is manufactured in
conformance with RB TR 100376351.002-2003 and essential requirements of technological
regulations, is approved by QCD and is classified as fit for operation.
16. Potential problems
Problem
Probable reason
Fault elimination
The device does not
operate
a) there is no voltage;
b) the wires in terminals 1 and 2
are not clamped well.
a) apply the voltage supply
at terminals 1 and 2.
b) clamp the wires in the
terminals 1 and 2.
The curtain moves in an
opposite direction when it
is controlled by the
remote control button of
definite command.
The drive wires are connected
incorrectly.
To change the drive wires
connected to the terminals
4 and 5.
The device operates,
indicator blinks red or
green but the voltage is
not supplied on drive.
a) the jumper between terminals
6 and 7 is not installed;
b) the jumper between terminals
6 and 7 is not clamped well.
a) install the jumper
between terminals 6 and 7;
b) clamp the jumper
between terminals 6 and 7.
The device is not entered
in the programming mode
a) latching switch is connected,
and the button of one of
directions is pressed.
a) change the latching
switch on the switch
without fixation;
by pressing the
programming button.
b) switch cable is out of service;
c) the switch is out of service
b) check/change cable;
c) check/change switch.
The drive is turned on for
a short time, roller shutter
twitches and stops.
a) the short command mode is
installed;
b) a short command time is
installed, which is not
insufficient for the full closing of
roller shutter.
a) install the necessary
mode;
b) install the necessary
command time or reset to
factory setting.
The device is not
controlled using remote
control and key switch,
red visual indicator blinks
permanently.
a) incorrect operation mode of
safety inputs is installed;
b) there is an obstacle in area of
connected safety sensor;
c) cable leading to the safety
sensor is impaired.
a) install the mode of safety
inputs in accordance with
the sensor or reset to
factory setting.
b) remove an obstacle in
area of sensor;
c) check/change the cable.
Made in the Republic of Belarus
Manufacturer:
Nero Electronics LLC
Belarus, 223016, FEZ Minsk, Minsk district,
Novy Dvor rural council, 74
tel./fax: (+375 17) 388-53-00,
www.neroelectronics.by
Representative office in Belarus:
Sketch LLC
220073, Minsk, 2b Skryganova str,
office 306
tel./fax: (+375 17) 317-02-32,
Representative offices in Russia:
SketchNerogroup LLC
119361, Moscow, 15 Bolshaya Ochakovskaya Str.,
building 1
tel./ fax: (+7 495) 430-79-60, (+7 495) 735-64-47,
(+7 495) 735-66-58, [email protected]
Nero SPb LLC
136070, St. Petersburg, 14 Komsomol Str., building 2
tel.: (+7 812) 987-51-56, (+7 981) 757-90-45,
Representative office in Ukraine:
Umnyye resheniya LLC
03138, Kiev, Smolnaya Str., 9B
tel./fax: (+38 067) 679-51-22, (+38 044) 500-18-55,
Other Nero Control Unit manuals