Nero Radio 8117 micro User manual

Radio card
Radio 8117 micro
Рassport
2. Specifications
Supply voltage range AC/DC, V............................................................................................................................~9-24/=12-30
Consumed current, mA ...................................................................................................................................................NMT 100
Maximum permissible switching current, A...............................................................................................................5 (at cos=1)
Number ochannels.........................................................................................................................................................................2
Command duration (for each channel), s..................................................................................................................................1,5
Operating frequency range, MHZ.................................................... .. -.................................................................. 433,05 434,79
Number of recorded remote control codes .............................................................................................................................500
Overall dimensions,mm.................................................................................................................................................98×32×22
Operating temperature range, °C........................................................................................................................from -30 to +50
2
Connector wires section.....................................................................................................................................................0,5 mm
Degree of case protection ......................................................................................................................................................IP55
- control using the Radío series remote controls;
3. Special features
- supporting a new improved dynamic radio protocol with high range and noise immunity;
- 2 channels to control other manufacturers automation;
The product is not intended to be installed and operated in explosive and fire hazardous areas and does not require
protective grounding.
- supporting remote controls with feedback (see remote control instructions);
- retransmission the dynamic code of the Radio series remotes.
4. Connection
Connecting wires and cables with polyethylene insulation or sheath are not allowed.
It is not allowed to install the device at a distance of less than 1 m from heating appliances.
The holes in the cable glands must be made with a tool of a smaller diameter than the inserted cable.
5. Remote control programming
The radio card Radio 8117 micro is designated to control the automation
units of sliding, swinging, sectional doors and barriers.
1. Designation
Channel 1
Channel 2
Antenna
Programming button
(light indicator)
~ 9–24 В
= 12–30 В
Power supply
General/com
Figure 1 — Radio card connection
Action
Indication
1. Enter the device into remote control programming mode (remote control PM)
Press and hold the Programming button for more than 4 s.
Indicator lamp is red.
2. Select a channel for remote control record
Press and hold the Programming button for more than 1 s (channels change
circle-wise).
2 – 2nd channel.
The number of red blinking
1 – 1st channel;
3. Record remote control channel to the device memory
One channel of the remote control can be recorded in only one of the two channels of the device, i.e., two
channels cannot be recorded in one channel of the remote control.
Since 2019, most remote controls are available with a dynamic code as the factory setting. See the instructions
for the remote control for details.
Radio
8101-1M
b) in static mode: press briefly the remote control button
(less than 1 s).
a) in dynamic mode: press the remote control button and hold
it for more than 2 s;
- the channel is recorded: 1 beep l and
1 diode blink for the recorded channel;
During recording, the device indicator
light flashes green short-long-short.
If the remote control is already
recorded, the indicator flashes green
briefly.
Remote control indication in dynamic
mode with feedback:
If the memory is full, the indicator
flashes yellow for 3 s.
- the channel is not recorded: 3 beeps
and 3 diode blinks for the recorded
channel (see the instructions for the
remote control).
Radio
8101-2M
8101-4M
b) in static mode: press briefly the recordable button.
a) in dynamic mode: press the recordable remote control
button and, while holding it, briefly press any other one;
Radio
8101-5
8101-15
2) press briefly the «STOP» button.
c) in dynamic mode with feedback:
1) select a recordable channel;
2) record the channel:
-press simultaneously the «STOP» and «UP» buttons;
a) in dynamic mode:
b) in static mode:
1) select a recordable channel;
1) select a recordable channel;
2) record the channel: press the «STOP» button and,
without releasing it, briefly press the «UP» button, then
release both buttons.
- receive the remote control signal about successful
recording to the device (for more details, see the
instructions for the remote).
-release the UP button, without releasing «STOP»
Action
Indication
3. Delete remote control channel from device memory (remote control PM)
8101-1M
Radio
2) remove the remote control: press the remote control
button and hold it for more than 1 s.
b) in static mode: press the remote control button and hold it
for more than 1 s.
1) enter the remote control into programming mode: press
the button 3 times in a row, and for the fourth one - hold
the button for 4 s. The pressing interval should not exceed
1 s;
a) in dynamic mode:
Upon removal, the device light
indicator will flash for a long time and
continue to flash in red.
In PM, the remote control light
indicator flashes red.
8101-2M
8101-4M
Radio
a) in dynamic mode: press the button of the deleted channel
and, holding it, press any other and hold it for more than 1 s,
then release both buttons;
b) in static mode: press and hold the button of the deleted
channel for more than 1 s.
Remote control indication in dynamic
mode with feedback:
-channel deleted: 2 beeps and 2
diode blinks for the deleted channel;
-channel has not been deleted: 3
beeps and 3 diode blinks of the
deleted channel (see instructions for
the remote control) in red.
The device light indicator will flash for
a long time and continue to flash.
Radio
8101-15
8101-5
a) in dynamic mode:
1) select the deleted channel;
2) record the channel, press the «STOP» button and
without releasing press briefly the «DOWN» button, release
both buttons.
b) in dynamic mode:
1) select the deleted channel;
c) in dynamic mode with feedback:
1) select the deleted channel;
2) record the channel,
-press simultaneously the «STOP» and «DOWN» buttons;
-release the «DOWN» button without releasing the «STOP»
button (to receive the remote control signal about
successful removal from the device, see the instructions for
the remote control for more details).
2) press briefly the «STOP» button.
4. Delete channels of all remote controls from the device memory (remote controls PM)
Press and hold the Programming button for more than 8 s.
The light indicator flashes red twice
for a long time.
5. Remove the device from the programming mode of the remote controls
Press briefly the Programming button.
Light indication stops.
In case of inactivity, the device will automatically exit programming mode after 32 s
The device can operate in one of three modes.
6. Mode of operation
Single-channel mode (command duration is 1.5 s) is used to control a single object. For example, a barrier: 1st channel
is responsible for the UP direction, and the second – DOWN direction. In this case, control is performed by all remote
controls recorded in both channels of the device (see Figure 2).
Two-channel mode (factory setting). Command duration is 1.5 s. It is used to control two automation objects. However,
it should be taken into account that the radio card has one common input (3 “com” terminal), and it is not possible to
connect it to different potentials at the same time (see Figure 3)
Continuous command mode (command duration is infinite). It is used to control automation objects in which a
continuous command is required, for example, a command to block the doors or gates automation. However, it should be
taken into account that the radio card has one common input (3 “com” terminal), and it is not possible to connect it to
different potentials at the same time (see Figure 4).
Barrier/door
control unit
Figure 2 — Single-channel mode
Figure 3 — Two-channel mode
1
1
-
+
Сh
Сh
1
2
3
4
5
Barrier/door
control unit
Barrier/door
control unit
com
-
+
Сh
Сh
1
2
3
4
5
com
-
+
Сh
Сh
com
1
2
3
4
5
Figure 4 — Continuous command mode
Sliding door
control unit
-
+
Сh
Сh
com
1
2
3
4
5
lock
P

Made in Belarus
2
Action
Indication
1. Enter the device into the repeater PM from standby mode
Press and hold the Programming button for more than 8 s.
The light indicator flashes green a certain
number of times.
2. Change repeater mode
The retransmission function changes each time you press and hold the
Programming button for more than 1 s (until the yellow flash).
3 - retransmission of commands of the new
improved dynamic protocol is enabled (see
Figure 5).
1 - command retransmission is off (factory
setting);
Number of flashes:
2 - retransmission of dynamic protocol
commands is enabled (see Figure 5);
3. Remove the device from programming mode
Press briefly the Programming button (less than 1 s).
The light indication stops.
In case of inactivity, the device will automatically exit programming mode after 32 s.
7.1. Enable or disable the retransmission function
The retransmission of the remote control sending is carried out only in combination with the control of power
relays.
Do not enable retransmission unless absolutely necessary.
Do not retransmission relay on devices nearby.
Do not enable retransmission on a large number of devices. This may interfere with sending the second remote
command, following after a short period of time (1-2 s).
The device feeds short pulses (1.5 s) when the relay closes.
In single-channel mode, Channel 1 is responsible for the UP direction, Channel 2 is responsible for the DOWN direction
(when controlling from remote controls with unambiguous commands: Radio 8101-2M, Radio 8101-5, Radio 8152-50).
In dual-channel mode, each channel operates in a step-by-step mode.
8. Device operation
Products must be transported in package in containers, closed railway cars, heated sealed compartments of aircraft and
holds, as well as automobile transport with protection against precipitation at any distance at temperatures from -50°С
to + 50°С, and with relative humidity up to 100% - at 25°С.When transporting products, protection from dust and
atmospherical condensation should be provided.
At the end of its service life, the product must be disposed of in accordance with the laws of the host country. The
product is not dangerous for human life and health, as well as for the environment. The product does not contain non-
ferrous and precious metals.
12. Manufacturer's warranties
9. Routine maintenance
Radio card Radio 8117 micro.................................................................................................................................................1pc.
Data sheet................................................................................................................................................................................1pc.
Individual package....................................................................................................................................................................1pc.
The radio card Radio 8117 micro (see the serial number on the first page) is made in accordance with the requirements of
TR BY 808001034.009-2018, accepted by the Quality Control Department and recognized as serviceable.
10. Storage, transportation, service life
13. Scope of supply
Products should be stored in packaging at temperatures from + 5°С to + 40°С and relative air humidity of no more than
80% in heated and naturally ventilated warehouses, in air-conditioned warehouses in the absence of aggressive
impurities, conductive dust, acid fumes and alkalis, as well as gases that cause corrosion and destroy insulation. During
storage, sharp fluctuations in temperature (more than 3°C/min) and air humidity (more than 5%/min) are not allowed.
If a malfunction is detected during operation, immediately disconnect the device from the mains and call service
personnel. Repair of the product during the warranty period and service is performed by the manufacturer's dealer.
The warranty period is 24 months from the date of sale.
11.Disposal
15. Potential problems
The average product life is at least 5 years.
In the absence of a mark on the sale - from the date of manufacture.
Warranty obligations do not apply to the product in case of mechanical damage, as well as in case of non-compliance with
storage, transportation and operation conditions. Warranty obligations do not apply if the passport is not submitted.
The warranty shelf life is 6 months from the date of manufacture (the last 6 digits in the serial number of the device, for
example: 191117 - November 19, 2017).
14. Acceptance certificate
Problem
Possible cause
Troubleshooting
Device does not function.
b) the wires in terminals 4 and 5 are
poorly clamped;
a) the supply voltage is not applied;
a) supply voltage;
b) clamp the wires in terminals
4 and 5.
Dynamic
protocol
Enhanced
dynamic
protocol
Radio
8117 micro
Retransmission
Dynamic
protocol
Enhanced
dynamic
protocol
Mode 2
Mode 3
Figure 5 – Retransmission modes
Version 1
7. Retransmission
Only dynamic code is retransmitted!
The retansmittion function is necessary to increase the transmission distance of the remote control signal due to the
repeater built into the radio card. This function is used in case of strong interference, large distances, and the presence of
a large number of obstacles. For example, to control a group of devices located at an object with difficult reception
conditions, it is necessary to record the remote control in all devices and enable the relay function on one or more of them.
Devices intended for retransmission are selected based on the size and characteristics of the object. As a rule, the
repeater should be in the middle of the distance, between the most remote control points of the remote control receiver.
3. Reset to factory settings
2) enter the device in the modes PM: press and hold the Programming button
for more than 1 s;
1) enter the device in the remote control PM: press and hold the Programming
button for more than 4 s;
3) being in modes PM: press and hold the Programming button for more than
4 s.
2) the light indicator flashes green
according to the selected mode;
3) the light indicator flashes long
yellow and continues to blink green.
1) the light indicator flashes red;
4. Remove the device from the programming mode
Press briefly the Programming button once.
The light indication stops.
In case of inactivity, the device will automatically exit programming mode after 32 s.
Action
Indication
1. Enter the device into the programming mode of operation modes (modes PM)
1) enter in the remote controls PM: press the Programming button and hold it
for more than 4 s;
2) enter in the operating modes PM: press briefly the Programming button.
2) the light indicator flashes green a
certain number of times.
1) the light indicator flashes red;
2. Change device operation mode
Modes are switched in a circle each time the Programming button is pressed
while holding it for 1 second (until the flash is yellow).
Number of flashes:
3 — continuous command mode.
1 — single-channel operation mode;
2 — two-channel operation mode
(factory setting);
6.1. Operation mode change
SketchNero Group LLC
Tel.: +7 495 430-79-60
+7 495 735-64-47
info@nerosk.ru
technical support:
Representative offices
in Russian Federation:
15, Bolshaya Ochakovskaya St.,
119361, Moscow.
8 800 5000-930
Manufacturer and representative
office in Belarus
+375 29 610-12-53
Tel.: +375 17 388-53-00
Nero Electronics LLC
by-order@neroelectronics.by
Minsk FEZ, 223016, Minsk district,
Novy Dvor Rural Council, 74
www.neroelectronics.by
+375 29 609-25-59
technical support:
Umnye resheniya LLC
Tel.: +38 067 679-51-22
+38 044 500-18-55
Representative office
in Ukraine:
ua-order@neroelectronics.by
+380 67 679-51-22
21, B. Khvoyki St., Office ,
03022, Kiev.
technical support:
Nero SPb LLC
technical support:
14, Komsomola St., Build. 2,
195009, St. Petersburg
Tel.: +7 812 987-51-56
+7 981 757-90-45
spb-order@neroelectronics.by
8 800 5000-930
Other Nero Control Unit manuals
Popular Control Unit manuals by other brands

Toro
Toro 53380 installation instructions

Emerson
Emerson Anderson Greenwood M4TL manual

Distech Controls
Distech Controls IO-R-16 manual

Combat HVAC
Combat HVAC NRG Control Installation, operation and service manual

Festo
Festo LFR-D Series operating instructions

Kessel
Kessel Staufix Installation and operating instructions