Table of Contents
1. Introduction..................................................................................................................................... 2
2. ProductAppearance ....................................................................................................................... 3
3. Specification .................................................................................................................................... 4
4. Installation....................................................................................................................................... 4
5. Setting up ZL01E............................................................................................................................ 5
5-1. Join the ZigBee Network........................................................................................................ 5
5-2. Permit-Join ............................................................................................................................. 5
5-3. Switch Transmission Mode .................................................................................................... 5
5-4. Control and Management ....................................................................................................... 6
5-5. Restore to Factory Setting...................................................................................................... 6
6. Home Automation Clusters for ZL01E......................................................................................... 6
7. Important Maintenance Instructions............................................................................................ 8

2
1. Introduction
Netvox ZL01E, the ZigBee gateway, acts as a Coordinator or a Router Device in ZigBeenetwork. It is designed to
interface the USB terminals with ZigBee network. There are two transmission modes: the data-transmission mode
and the command-transmission mode. Any terminal is able to send data wirelessly via ZL01E under the
data-transmission mode. Under the command-transmission mode, it is able to collect network information using
ZigBee application.
What is ZigBee?
ZigBee is a short range wireless transmission technology based on IEEE802.15.4 standard and supports multiple
network topologies such as point-to-point, point-to-multipoint, and mesh networks. It is defined for a
general-purpose, cost-effective, low-power-consumption, low-data-rate, and easy-to-install wireless solution for
industrial control, embedded sensing, medical data collection, smoke and intruder warning, building automation
and home automation, etc.

3
2. Product Appearance
Network Indicator
USB Port
Permit-join Key

4
3. Specification
yFully IEEE 802.15.4 compliant
yUtilizes 2.4GHz ISM band; up to 16 channels
yPower supply: 5V DC
yUp to 150 meters wireless transmission range in non-obstacle space
yEasy installation and configuration
4. Installation
yThis device is NOT truly waterproof/ resistant and is for indoor use.
USB to ZL01E USB to computer

5
5. Setting up ZL01E
5-1. Join the ZigBee Network
A. When ZL01E is a Coordinator.
It will establish a ZigBee network after powering on. The indicator will stay ON after the network is created
successfully. Otherwise, the indicator will be OFF.
B. When ZL01E is a Router Device.
It will search for an existing ZigBee network and send a request to join the network automatically after
powering on. While ZL01E is under the coverage from a coordinator or a router whose permit-join feature is
enabled, ZL01E will be permitted to join the network. The indicator will stay ON after it is joined
successfully.
5-2. Permit-Join
ZL01E is designed to work as a coordinator or a router. To allow other devices to join the ZigBee network,
users could enable the Permit-Join feature using the tips:
A. Press the Permit-join Key once to enable the Permit-Join feature. The indicator will flash once per
second.
B. The default Permit-Join period of time is 60 seconds.
5-3. Switch Transmission Mode
ZL01E performs two transmission modes: the data-transmission mode (default) and the
command-transmission mode.
To switch the modes, please use this command format:
02 Cmd=0x0FFE Len=0x11 Data CRC
The command to switch to data-transmission mode
"020FFE117777772E6E6574766F782E636F6D2E636ECB"
It is actually "www.netvox.com.cn"
After it switches to data-transmission mode successfully, the stream "021FFE0100E0" is returned.
In data transmission, ZL01E broadcasts data wirelessly. Raw data ‘010203’, for example, can be entered and
transmitted directly. Raw data can also be received wirelessly without any need of conversion. The data
received can be ported to serial connection of, for example, a PC.
The command to switch to command-transmission mode
"020FFE115757572E4E4554564F582E434F4D2E434ECB"

6
It is actually "WWW.NETVOX.COM.CN"
After it switches command-transmission mode successfully, the stream "021FFE0100E0" is returned.
The module strictly follows Profile Command to sent and receive control commands.
5-4. Control and Management
Users could use ZiG-BUTLER to manage your ZigBee network. From ZiG-BUTLER, you are able to send
ON or OFF command to the ZigBee network. Follow the instructions bellow for control and management.
5-5. Restore to Factory Setting
To restore it to factory setting, please follow the steps:
Step1. Power off ZL01E.
Step2. Press and hold the Permit-join Key.
Step3. Do not release the key and power on ZL01E to complete the restore.
6. Home Automation Clusters for ZL01E
A cluster is a set of related attributes and commands which are grouped together to provide a specific function. A
simple example of a cluster would be the On/Off cluster which defines how an on/off switch behaves. This table
lists the clusters which are supported by ZL01E.
1.End Point(s):0x0A
2.Device ID:Combined Interface(0x0007)
3.EndPoint Cluster ID
Server side Client side
Mandatory
Basic(0x0000)
Identify(0x0003)
Commissioning(0x0015)
Diagnostics(0x0B05)
Optional
This lists the attributes of the basic information.

7
Identifier Name Type Range Access Default Mandatory
/ Optional
0x0000 ZCLVersion Unsigned
8-bit integer
0x00 –
0xff
Read only 0x03 M
0x0001 ApplicationVersion Unsigned
8-bit integer
0x00 –
0xff
Read only 0x28 O
0x0002 StackVersion Unsigned
8-bit integer
0x00 –
0xff
Read only 0x33 O
0x0003 HWVersion Unsigned
8-bit integer
0x00 –
0xff
Read only 0x0D O
0x0004 ManufacturerName Character
string
0 – 32
bytes
Read only netvox O
0x0005 ModelIdentifier Character
string
0 – 32
bytes
Read only ZL01EE3C
/ZL01EE3R
O
0x0006 DateCode Character
string
0 – 16
bytes
Read only 20131216 O
0x0007 PowerSource 8-bit
Enumeration
0x00 –
0xff
Read only 0x04 M
0x0010 LocationDescription Character
string
0 – 16
bytes
Read/write O
0x0011 PhysicalEnvironment 8-bit
Enumeration
0x00 –
0xff
Read/write 0x00 O
0x0012 DeviceEnabled Boolean 0x00 –
0x01
Read/write 0x01 M

8
7. Important Maintenance Instructions
•Please keep the device in a dry place. Precipitation, humidity, and all types of liquids or moisture can contain
minerals that corrode electronic circuits. In cases of accidental liquid spills to a device, please leave the device
dry properly before storing or using.
•Do not use or store the device in dusty or dirty areas.
•Do not use or store the device in extremely hot temperatures. High temperatures may damage the device or
battery.
•Do not use or store the device in extremely cold temperatures. When the device warms to its normal
temperature, moisture can form inside the device and damage the device or battery.
•Do not drop, knock, or shake the device. Rough handling would break it.
•Do not use strong chemicals or washing to clean the device.
•Do not paint the device. Paint would cause improper operation.
Handle your device, battery, and accessories with care. The suggestions above help you keep your device
operational. For damaged device, please contact the authorized service center in your area.
Table of contents
Other netvox Gateway manuals