NEULOG ROTARY MOTION LOGGER SENSOR GUIDE
NeuLog rotary motion logger sensor
NUL-226
The NeuLog rotary motion sensor can be used for any science experiment which
involves rotary motion including angular velocity, angular acceleration and revolutions
per second such as in the fields of Mechanics, Physics, Biomechanics, etc.
The sensor comes pre-calibrated so you can start experimentation right out of the box
using this guide.
Among hundreds of possible experimental subjects that can be studied with the NUL-
226 sensor are: rotary motion studies, angular velocity, angular acceleration, sine
waves, torque, engine studies, and many more.
The rotary motion sensor's measurement units are:
Degrees (°): The standard unit for measuring angles
Radians per second (rad/s): The angular displacement’s rate of change
Radians per second squared (rad/s2): The angular velocity’s rate of change
Revolutions per second (rev/s): The total number of complete revolutions
per second.
Using the rotary motion sensor:
The rotary motion sensor can be set up in your classroom or lab in many different
configurations:
Connecting the revolving head to a conveyor system
Rolling the revolving head along a surface
Spinning the revolving head manually.
Quick start procedure:
PC or Mac Computer
Materials needed:
NUL-226 Rotary Motion Sensor
USB-200 USB Module
USB to mini USB cable (included with the USB-200 module)
Your rotary motion sensor needs to be connected to a USB-200 module. The USB-
200 module then connects to a computer via a USB to mini-USB cable. Please note
that you cannot plug the rotary motion sensor directly into the computer.
The browser based application can be downloaded for free at www.NeuLog.com as
well as a full application user guide.
Choose "Downloads" on the main menu and then choose "Software and Application".
Procedure:
1. Install the NeuLog application.
2. Connect the USB-200 module to the PC or Mac.
3. Connect the rotary motion sensor to the USB-200 module (they directly plug
together). Please note there is no calibration required for this sensor.
4. Open the NeuLog application by clicking on the shortcut on the screen.
5. Once a rotary motion sensor module box appears on the left side of the screen
the probe has been automatically identified and you can begin experimentation.
6. If the rotary motion sensor is not automatically identified, click the “Search for
sensors” icon to find the sensor.
7. Select the “On-line experiment” icon; this will open a graph below.
8. Click on the “Module setup” button located in the rotary motion sensor module
box to change the sensor's settings if need be.
9. Click on the "Experiment setup" icon to change the experiment settings if need
be (experiment duration for example).
10. The rotary motion sensor will give a live reading in the module box to the left of
the screen while plugged in.
11. To run an experiment and collect data click the “Run experiment” icon.
12. To end data collection early, click the “Stop experiment” icon.
Tablet, smart phone device
Materials needed:
NUL-226 Rotary Motion Sensor
WIFI-201 WIFI module
BAT-200 Battery Module
Your rotary motion sensor needs to be connected to a WIFI-201 module. The WIFI-
201 module will create a closed NeuLog WiFi network which will stream the NeuLog
data to a device of your choosing. Once your device is wirelessly connected to the
NeuLog network, you can run experiments and collect data through a browser of your
choosing.
Procedure:
NEULOG ROTARY MOTION LOGGER SENSOR GUIDE
1. Connect the rotary motion sensor directly to the left side of a WIFI-201 (no wires
required).
2. Connect a BAT-200 module to the right side of the WIFI-201 module.
3. Although not required, we recommend plugging the BAT-200 to an outlet using a
USB to mini USB charger (such as a typical cell phone charger). The WIFI-201
module will run for 60-90 minutes (depending on the sensor) without being
plugged in.
4. The WIFI-201 can be powered directly using a mini to USB cord and plugging it
into your computer or a wall charger. Please note this function is only available
on WIFI-201 modules with the USB icon on the cover.
5. For further WIFI-201 instructions or the WIFI-201 quick start guide please visit:
www.NeuLog.com; Choose "Products" on the main menu,
then choose "WiFi Communication module".
6. The WIFI-201 indicator lights will flash; take no action until the LED to the far left
turns blue; this can take up to one minute.
7. Take your tablet or smart phone, go to the WiFi settings and select the NeuLog
network (NeuLog0184 for example) which matches the ID found on the back of
the WIFI-201 module (0184 for example).
8. Give your device about 20 seconds to connect to the WIFI-201.
9. Once the device is connected, go to your browser and type the website
wifi201.com into the URL bar, then wait for 30-60 seconds.
10. You will see a “Control mode” icon in the application, click on it.
11. The application will then load a new screen and begin to auto detect the
sensor(s); this can take a minute. (You can stop the search when the sensor is
found.)
12. If the browser does not auto detect the sensor(s), select “Search for sensors”.
13. Once the sensor is found you will see a module box on the left side of the screen
for the rotary motion sensor. In this box, real time data will be displayed.
14. Click on the “Module setup” button located in the rotary motion sensor module
box to change the rotary motion probe settings if need be.
15. Click on the “Experiment setup” icon to change the experiment settings if need
be (Experiment duration for example).
16. To run an experiment and collect data, click the “On-Line experiment” icon, then
click the "Run experiment" icon.
17. If you have a newer generation WIFI-201 (with the USB icon on the cover) this
can be used as a USB-200, meaning you can tether the probes directly to the
computer using the WIFI-201. To engage operation in this fashion, press 3 times
on the panel button. Repeating this operation will return the module to WiFi
mode.
Operation with NeuLog Graphic Display Module (viewer)
Materials needed:
NUL-226 Rotary Motion Sensor
VIEW-101 Graphic Display Module
BAT-200 Battery Module
Procedure:
1. Connect the rotary motion sensor to the left side of the viewer.
2. Connect the BAT-200 module to the right side of the viewer.
3. The VIEW-101 will auto detect the sensor and you will see it appear on the left
side of the screen.
4. Once the sensor appears it will be monitoring data in real time.
5. To run an experiment and collect data press the run icon (little green person).
Off-line experiments
(Off-line experiments are when you do not have a sensor connected directly to a
computer, tablet, smartphone, or NeuLog viewer).
Materials needed:
NUL-226 Rotary Motion Sensor
BAT-200 Battery Module
Materials needed to configure your offline experiment:
USB-200 Module, WIFI-201 module or VIEW-101 Module
USB to mini USB cable (included with the USB-200 module).
Procedure:
1. To determine the experiment settings, first connect to your chosen device (PC,
Mac, tablet, smart device) and click on the “Off-line experiment” icon after the
sensor search has ended. (For more information on how to change the
experiment settings, view the quick start procedure section for your chosen
device in this document.)
2. Connect the rotary motion sensor directly to the left side of a charged BAT-200
module.
3. When ready to collect data press the “Start/Stop” button on the rotary motion
sensor, a red light will turn on for the duration of the experiment.
NEULOG ROTARY MOTION LOGGER SENSOR GUIDE
4. After the experiment has concluded (the “Start/Stop” button is pressed again or
the data collection period ends) connect the sensor to your chosen device (you
can find full instructions in each device’s quick start procedure section).
5. Open the NeuLog application.
6. Click the “Off-line experiment” icon.
7. Click the “Load data from sensors” icon.
8. Select which experimental data to upload (5 experimental runs can be stored at
one time on the NUL-226 rotary motion sensor).
Restoring sensor’s factory default settings:
Procedure:
1. Connect the USB-200 to a PC, Mac, tablet, or smart device.
2. Connect the rotary motion sensor to a USB-200 module (they directly plug
together).
3. Open the NeuLog application.
4. Click the “Tools” icon.
5. Click the “Restore sensor’s factory defaults” on the menu.
Included with the sensor:
NeuLog NUL-226 Rotary Motion Sensor Guide (this document).
Rotary motion revolving head piece attached directly to the sensor's body by a
durable rubber-coated wire.
Sensor's specifications
Range and
operation modes
ADC
resolution
Resolution
Max
sample
rate
(S/sec)
°
0 to 360
16 bit
0.09
100
Rad/s
±345
0.6
Rad/s2
±32,222
14
Rev/s
±55
0.03
Experiment Duration: 1 second to 31 days.
Sensor's features:
Fully digital data
Rugged plastic ergonomic case
Rotary motion rotating head piece attached directly to the sensor's body by a
durable rubber-coated wire
Push button switch for Start/Stop experiments in off line mode
LED indicator of experiment status (blinks while collecting data)
Pre-calibrated sensing equipment
Note: NeuLog products are intended for educational use.
Videos and experiment examples:
Videos, literature and other probes can be found at www.NeuLog.com.
In order to access the rotary motion sensor's page, choose "Products" on the
main menu and then "Rotary motion logger sensor".
In order to find the science experiments, choose "Experiments" on the main
menu of the NeuLog website, then choose "Physics", "Chemistry", "Biology" or
"Environmental Science".
Physics Experiment:
oSimple Pendulum (P-46)
Technical background:
The philosophy behind NeuLog’s plug and play technology is based on each sensor’s
ability to store its own data due to an internal flash memory chip and micro-controller
in each plastic NeuLog body. This technology allows the sensor to collect and then
store the digital data in the correct scientific units (oC, oF, Lux, %, ppm, for example).
The sensor is pre-calibrated at the factory. The built-in software in the logger can be
upgraded for free at any time using the provided firmware update.
NEULOG ROTARY MOTION LOGGER SENSOR GUIDE
The probe shaft is installed in a bearing and has a magnet at its end. A digital sensor
based on The Hall Effect sensor, an analog circuit and a very sophisticated digital
processor are located near the rotating magnet.
The analog and digital circuits analyze the rotating magnetic field and calculate the
angle, rotation speed, acceleration and revolutions, transferring this data to the
sensor's controller, upon its request.
Maintenance and storage:
Never submerge the NeuLog plastic body in any liquid.
Do not allow liquid into the rotary motion sensor’s body.
After use, gently wipe away any foreign material from the rotary motion sensor.
Store in a box at room temperature out of direct sunlight.
Warranty:
We promise to deliver our sensor free of defects in materials and workmanship. The
warranty is for a period of 3 years from the date of purchase and does not cover
damage of the product caused by improper use, abuse, or incorrect storage. Sensors
with a shelf life such as ion selective probes have a warranty of 1 year. Should you
need to act upon the warranty, please contact your distributor. Your sensor will be
repaired or replaced.
Thank you for using NeuLog!
Flexible, simple, fast, forward thinking.
W: www.neulog.com
E: info@neulog.com
A: 850 St Paul Street, Suite 15, Rochester, NY 14605
P: 1.866.553.8536
V11042014

Other NeuLog Data Logger manuals

NeuLog NUL-226 User manual

NeuLog

NeuLog NUL-226 User manual

NeuLog NUL-208 User manual

NeuLog

NeuLog NUL-208 User manual

NeuLog NUL-204 User manual

NeuLog

NeuLog NUL-204 User manual

NeuLog NUL-201 User manual

NeuLog

NeuLog NUL-201 User manual

NeuLog NUL-217 User manual

NeuLog

NeuLog NUL-217 User manual

NeuLog NUL-233 User manual

NeuLog

NeuLog NUL-233 User manual

Popular Data Logger manuals by other brands

ST HT22IoT user manual

ST

ST HT22IoT user manual

ELPRO LIBERO CE Operation manual

ELPRO

ELPRO LIBERO CE Operation manual

T&D TR41 user manual

T&D

T&D TR41 user manual

Elitech RC-5+ user manual

Elitech

Elitech RC-5+ user manual

globalwater GL500-7-2 manual

globalwater

globalwater GL500-7-2 manual

GFZ DiGOS Omnirecs DATA-CUBE3 Series user manual

GFZ

GFZ DiGOS Omnirecs DATA-CUBE3 Series user manual

Rotronic RMS-LOG-915 Short instruction manual

Rotronic

Rotronic RMS-LOG-915 Short instruction manual

Dahua EEC300D8-N1 quick start guide

Dahua

Dahua EEC300D8-N1 quick start guide

Clarke CIXTLI1 User instructions

Clarke

Clarke CIXTLI1 User instructions

Eagle Tree Systems eLogger V4 instruction manual

Eagle Tree Systems

Eagle Tree Systems eLogger V4 instruction manual

Sungrow Logger3000 user manual

Sungrow

Sungrow Logger3000 user manual

MadgeTech pHTemp2000 Product user guide

MadgeTech

MadgeTech pHTemp2000 Product user guide

Lascar EL-PDF-1 Series quick start guide

Lascar

Lascar EL-PDF-1 Series quick start guide

Gallagher HR5 instructions

Gallagher

Gallagher HR5 instructions

Hioki LR8432-20 instruction manual

Hioki

Hioki LR8432-20 instruction manual

Dynojet POWER VISION PV3-29-01 installation guide

Dynojet

Dynojet POWER VISION PV3-29-01 installation guide

Dostmann Electronic LOG40 operating instructions

Dostmann Electronic

Dostmann Electronic LOG40 operating instructions

AEMC Simple Logger II user manual

AEMC

AEMC Simple Logger II user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.