1
New Comfort
SS-7000
Commercial Air Purifier
OWNER’S MANUAL
Please read all of the information provided in this owner’s
manual before operating your new Commercial Air purifier.
2
Features of the SS-7000 Air Purifier:
•
Designed for the toughest of jobs with all Stainless Steel
construction.
•
Hi / Low mode allows you to choose 12,000 mg/hr of
odor cleaning or 6,000 mg/hr. Depending on the size or
type of the job you can choose which mode is best for
you.
•
Indicator light tells you when unit is running.
•
Powerful Fan allows it to work on up to 3500 square feet
per treatment.
•
This commercial unit is designed to remove the most
powerful odors.
•
UV bulb cleans the air as the Air Purifier runs.
•
3 Year Factory warranty. Designed to last in the
toughest cleaning jobs.
3
CAUTION
RISK OF ELECTRICAL
SHOCK DO NOT OPEN
ATTENTION
CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO
NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVCE PERSONNEL.
4
NEVER PLUG UNIT INTO A POWER STRIP. ALWAYS
PLUG UNIT INTO A WALL OUTLET
Read ALL instructions carefully before using this product.
This “bolt of lightning” indicates that un-insulated material within
your unit may cause an electrical shock. For the safety of everyone,
do not remove product covering.
WARNING – Failure to properly clean (every 6 months) inspect,
maintain, and/or replace defective ozone plates may result in a fire
hazard.
5
Model:
SS-7000
Rated Voltage:
USA/Japan AC 100-120V/50-60Hz
Power Consumption:
100W
Ceramic Plate Size(2plate):
90X50MM
Air Volume:
Max 100 CFM(2.8 M
3
/min)
Active Oxygen(on) D
6000mg/hr -
12000mg/hr(Low/High)
Sound Level(DB):
45 Db.
Product size(mm):
W6xH9xD13 IN
Weight:
6.4 lbs
6
Operating the Commercial Purifier
(Front View)
Timer Control Knob
Turn clockwise to set the timer for timed
operation up to two hours.
Indicator Light
Illuminates when unit is in operation.
High-low Switch
Ozone high (12000 mg/hr) and low (6000
mg/hr) change-over switch
7
(Back View)
Fuse Holder
Houses removable fuse.
(Spare fuse included, 1 amp, 0.79
inch in length)
Power Cord
100~120 Volt grounded cord (unless
otherwise).
8
The Commercial Air Purifier is designed to remove odors in
unoccupied spaces. The unit has a timer that will enable it to run
for a maximum duration of 2 hours. The timer will then shut the
commercial air purifier off. You should allow 40 minutes before
returning to the treated area.
To operate the Commercial Air Purifier:

Close off the desired area to be treated.

Remove all occupants and pets.

Position the unit as close as possible to the odor source.

In such environments as motels that have individual heating
and cooling systems, turn the fan on and set on re-circulate.

Set timer to desired time and leave the room.

Allow 40 minutes before re-entering the treated space.

Return to space & ventilation area.
9
When the air purifier no longer produces enough ozone to be
effective, the ozone plate should be replaced. (Usually it should be
replaced after working 5000 hours)
WARNING –Failure to properly clean (every 6 months) inspect, maintain,
and/or replace defective ozone plates may result in a fire hazard.
How to replace a plate
:
1) Turn the unit off and unplug from outlet.
2) Use a screwdriver to unfasten cover screw and remove cover.
3) Pull ceramic plate out of ozone generator module.
4)
Install ceramic plate as shown in above figure (be careful not
to drop the plate).
If you suspect a problem with your unit check the following:
10
1) Unit is plugged in properly.
2) It’s important that the Commercial Air purifier be properly
grounded to avoid potential shock.
3)
Fuse is installed properly and in good condition. To replace
fuse, pull out the plastic fuse holder, remove old fuse and
insert new fuse. Replacement fuse must be 1 amp (0.79
inch). Refer to picture as follows:
11
The New Comfort SS 7000 commercial air purifier is
covered by a 3-Year Limited Factory Warranty. The
warranty covers the complete unit except for filters or Ozone
Plates. New Comfort or its authorized service centers shall pay
for all parts and labor for authorized warranty claims. The
customer is responsible to pay for all shipping costs associated
with the warranty. To receive a warranty claim simply contact
your local New Comfort dealer where you bought the unit or
send an email to service@newcomfortcleaners.com.
12

Other New Comfort Air Cleaner manuals

New Comfort Prolux Enfinity User manual

New Comfort

New Comfort Prolux Enfinity User manual

New Comfort O3-1000 User manual

New Comfort

New Comfort O3-1000 User manual

New Comfort HMA-700/O3 User manual

New Comfort

New Comfort HMA-700/O3 User manual

New Comfort CH3000 User manual

New Comfort

New Comfort CH3000 User manual

New Comfort BL3000 User manual

New Comfort

New Comfort BL3000 User manual

New Comfort CH3000 User manual

New Comfort

New Comfort CH3000 User manual

New Comfort CA3500 User manual

New Comfort

New Comfort CA3500 User manual

New Comfort BH3000 User manual

New Comfort

New Comfort BH3000 User manual

New Comfort H2O-5000 User manual

New Comfort

New Comfort H2O-5000 User manual

Popular Air Cleaner manuals by other brands

FALMEC Bellaria Instruction booklet

FALMEC

FALMEC Bellaria Instruction booklet

Seben JH-1702 specification

Seben

Seben JH-1702 specification

Philips AC4030/00 user manual

Philips

Philips AC4030/00 user manual

Lanaform LA120209 manual

Lanaform

Lanaform LA120209 manual

AirGorilla PCO/UV N-Duct owner's guide

AirGorilla

AirGorilla PCO/UV N-Duct owner's guide

Mini Gadgets Bush Baby BB4KNEAir user manual

Mini Gadgets

Mini Gadgets Bush Baby BB4KNEAir user manual

Zonair3D AIR PRO 500 user manual

Zonair3D

Zonair3D AIR PRO 500 user manual

Hoover Air Cleaner Operating, and servicing  instructions

Hoover

Hoover Air Cleaner Operating, and servicing instructions

LG AS401VSA0 owner's manual

LG

LG AS401VSA0 owner's manual

Philips AC1711/21 user manual

Philips

Philips AC1711/21 user manual

Philips AC6675 user manual

Philips

Philips AC6675 user manual

Holmes Aer1 user manual

Holmes

Holmes Aer1 user manual

Kenmore 850e Series user manual

Kenmore

Kenmore 850e Series user manual

Bionaire PERMAtech BAP1552-CN Instruction leaflet

Bionaire

Bionaire PERMAtech BAP1552-CN Instruction leaflet

Airthereal Glory Days AGH430 user manual

Airthereal

Airthereal Glory Days AGH430 user manual

Fellowes 9286201 instruction manual

Fellowes

Fellowes 9286201 instruction manual

Avalla R-2000 manual

Avalla

Avalla R-2000 manual

Dust Care AC0401 Operation instructions

Dust Care

Dust Care AC0401 Operation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.