manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Newall
  6. •
  7. Controllers
  8. •
  9. Newall DP500 User manual

Newall DP500 User manual

Other manuals for DP500

2

Popular Controllers manuals by other brands

Digiplex DGP-848 Programming guide

Digiplex

Digiplex DGP-848 Programming guide

YASKAWA SGM series user manual

YASKAWA

YASKAWA SGM series user manual

Sinope Calypso RM3500ZB installation guide

Sinope

Sinope Calypso RM3500ZB installation guide

Isimet DLA Series Style 2 Installation, Operations, Start-up and Maintenance Instructions

Isimet

Isimet DLA Series Style 2 Installation, Operations, Start-up and Maintenance Instructions

LSIS sv-ip5a user manual

LSIS

LSIS sv-ip5a user manual

Airflow Uno hab Installation and operating instructions

Airflow

Airflow Uno hab Installation and operating instructions

ABB ACS580-01 drives Hardware manual

ABB

ABB ACS580-01 drives Hardware manual

Panasonic GM1 Series Reference manual

Panasonic

Panasonic GM1 Series Reference manual

Emerson SW93 owner's manual

Emerson

Emerson SW93 owner's manual

AutoAqua Smart ATO micro SATO-120P manual

AutoAqua

AutoAqua Smart ATO micro SATO-120P manual

Panasonic FP? Positioning Unit RTEX Technical manual

Panasonic

Panasonic FP? Positioning Unit RTEX Technical manual

Alpha IP MIOB 21001 manual

Alpha IP

Alpha IP MIOB 21001 manual

Siemens OpenAir GMA 1 Series Mounting instructions

Siemens

Siemens OpenAir GMA 1 Series Mounting instructions

Surecom SR-629 user manual

Surecom

Surecom SR-629 user manual

Regulus SRS1 T Installation and operation manual

Regulus

Regulus SRS1 T Installation and operation manual

3M MicroTouch EX113 reference guide

3M

3M MicroTouch EX113 reference guide

KUHN TKS user manual

KUHN

KUHN TKS user manual

S&C PMH Instructions for operation

S&C

S&C PMH Instructions for operation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

%12VJDL4UBSU(VJEF
4ECHNICAL3PECIFICATION
For the complete manual please download from:
http://newall.com , Click Technical Support to access the download page.
Environmental
Operating Temperature Storage Temperature
-10°C to 50°C -20 to 70°C
Environmental Conditions - IP40 (Stand Alone)
Relative Humidity - maximum 95% for temperature up to 31°C
Disposal
At the end of it’s life, you should dispose of the DP500 in a safe
manner applicable to electronic goods.
The case work is suitable for recycling. Please consult local
regulations on disposal.

023-82110-UK/0
#ONNECTIONS
Electrical
EU Directive 73/23/EEC (Low Voltage
Directive)
BS EN 55022:1998 Class B
BS EN 55024:1998
Input to Power Supply Unit (Supplied)
100-240V (47-63Hz)
External switch-mode
Output voltage 15VDC
Input Voltage to DP500
15-24VDC ±10%
Conforms to Low Voltage Directive
External PSU Input
Note: Newall Measurements Systems reserves the right to change specifications without notice.
7ARNINGS
The mains supply is connected into a switch mode power supply (separate from your DP500) via a
detachable supply cord supplied. If another supply cord is used, it must have fitted a C5, 10A, EARTHED
mains connector with a cord rated for at least 10A.
If a mains plug is not already fitted to the supply cord or is of the wrong type, then a suitable EARTHED plug
should be used which complies with the relevant specifications for plugs and socket-outlets.
You can only use the DP500 with Newall Spherosyn LT and Microsyn LT analogue encoders.
Unit only to be serviced by Newall qualified personnel or authorised alternatives.
If a Spherosyn LT encoder travels over 2.2m an error message will be displayed, see full manual for details.
Turn off the power by disconnecting the power supply connector before you connect the encoder(s)
Cabinet equipotential terminal
for grounding to machine
Cable Clamp
Encoder Input
Connection 2 or 3
According to Model
Technology Gateway, Cornwall Road South
Wigston, Leicester LE18 4XH
United Kingdom
Tel: +44 (0) 116 264 2730
[email protected].UK
www.newall.co.uk
USA
Tel: +1 614 771 0213
People's Republic of China
Tel: +86 212 2306 1500
Singapore
Tel: +65 647 86 867
Japan
Tel: +81 45 277 7120
&ORMOREINFORMATIONABOUTTHISORANYOFOURPRODUCTS
PLEASECONTACTUSATSALES NEWALLCOMORVISITWWWNEWALLCOM
3%44).' 50 4(% 5.)4
setup
language
5NDERSTANDINGTHE+EYPAD
Default Settings Optional Settings
Eng gb Eng US afr.
0RESETAN!XIS
=
Microsyn LT
Must be set to match encoders on the machine
*
*Lathe version, X axis set to DIA as default
Message
Display
Axis Selection Key
Numeric Keys
Enter Key
Clear Numeric Entry
Center Find
Undo Key
Digifind / Reference
Switches between Zero
and Axis Preset modes
Switches between Absolute
and Incremental modes
Information selection (scrolls
through options on Message
display)
Function Menu Key
Function Navigation Keys
Switches between Inch
and mm display
:EROAN!XISIN:ERO-ODE
Ensure DP500 is
in Zero Mode of Axis 1, 2 or 3
:EROAN!XISIN3ET-ODE
Ensure DP500 is
in Set Mode of Axis 1, 2 or 3
Ensure DP500 is
in Set Mode
Until display
shows
display
shows
Spherosyn LT
of axis 1
of axis 1, 2 or 3
See full manual on website for more details
user defined, use numeric keypad to enter value
(value is in whole minutes)
See full manual on website for more details to exit setup
of axis 1
cesky
DANSK deutsch espanol
francais italiano nederlan
pol
setup
TYPE GENERIC nnILL LATHE
setup
ENCODER S26-LT nn26-LT
setup
RES 0.005 0.01 0.02 0.05
setup
DIR ---| |---
setup
MEASURE RAD DIA
setup
ERR COMP
setup
PLANE
(----)
(----)
(----)
(----)
(----)
(----)
setup
funcs ON OFF
setup
bEEP on
setup
sleep
setup
COdE?
FUNCS
SETUP
-145.230
Note: values in mm
portugue russian
turkce
of axis 1, 2 or 3
of axis 1, 2 or 3
of axis 1, 2 or 3
of axis 1
%.4%2).' 3%450
set func
tools
of axis 1
to scroll through functions, to return to setup menu
OFF
of axis 1
0
setup
reset
Sleep key
Axis 1
Axis 2
Axis 3
Power
LED
T00l 01
950.355
100.2 5 0