CONNECTION NOTES
• Ensure that the grid mains connection is not connected until all connections are complete and the Pump
Controller casing is tted and locked closed.
• The Alarm Float is the smaller Reed Pivot Switch and the Pump Switches are the larger Vertical Action Float
Switches. The Alarm Float should be installed so that the switch is always closed and only opens when lifted
upwards by rising water.
• The three oats each have two wires. The connection of these wires is not dependent on polarity and can be
tted to either of the terminals for each connection.
• The three switches should be tted to the two pump vertical discharge pipes in order to give a switching
order of: PUMP 1; ALARM; PUMP 2
• Ensure that the switches are set at the correct levels so the pumps operate correctly. If the switch is too
high, the switch may not operate until the water level in the sump is at its peak. If the switch is too low, it is
possible that the pump removes all the water before the switch has turned off. It is vitally important to test
the pump switching to ensure the pumps operate correctly.
ALARM SET - Attach the battery with the alarm oat in the closed position.
The alarm will continue to sound and the Alarm Warning LED will ash until the client manually resets the alarm.
Pressing the mute button once mutes the buzzer and a second press will reset the alarm and cancel the ashing
LED light. This means that the client will be aware of an alarm condition, even when the second pump has
lowered the water in the sump.
CONNECTION TO NEWTON DIALER - PA5
The Newton Dialer can receive a signal from the alarm of the Pump Controller, allowing notice of the alarm
condition to be received as a voice message to landline phones and as a text message to mobile phones. Up to
8 separate numbers can receive the voice or text message.
The terminals for the connection to the Dialer are at the top of the inside circuit board of the Pump Controller.
Use normal two-core bell wire and make a connection with one of the two coloured wires between the NO
(Normally Open) terminal of the Alarm and Trigger Input 1 of the Dialer, with the other wire connecting the C
(Common) terminal of the Alarm with the OV Trigger Input of the Dialer.
The NC and C terminals in the Alarm (Labelled Dialer) can also be used to send a zero-voltage signal to home
alarm and BMS (Building Management System).
DISPLAY INFORMATION
The Pump Controller fascia is tted with LED lights which indicate the following:
• OPERATING - Blue LED lit steadily with option to reduce brightness via “Set” button (see Controls section on
page 9)
• PUMP 1 - Green LED lit steadily while Pump 1 is running on test
• PUMP 2 - Green LED lit steadily while Pump 2 is running on test (Pump 1 will also be running indicating high
water ingress). If Pump 1 is not running, this indicates that Pump 1 did not start. Contact service engineer.
NOTE: Alarm should have sounded also
• WARNING - Blue LED shows fault on High Water Alarm unit
• WATER HIGH - Blue LED shows High Water Alarm
INTERNAL INFORMATION
COUNTER - A 6-digit counter will count the number of times the output to Pump 1 operates. This count includes
the weekly pump test and pump operations activated by the oat switch. The counter is not enabled by default.
To enable the counter, move the J2 jumper on the PCB from both contact pins to just one contact pin. The
counter can be reset by shorting jumper J2.
CONTROLS
Pump Controller
When the Pump Test button is pressed for three seconds, initially Pump 1 will run for 5 seconds and then stop.
After a 5 second delay, Pump 2 will run for 5 seconds and then stop.
When the Set button is pressed briey, (for 1 second or less) the brightness of the “Operating” LED will be
reduced to half normal brightness. Pressing briey when at reduced brightness will return to default full
brightness setting.
When the Set button is pressed for more than 3 seconds, it will reset the weekly test operation timer so that the
next test will be at the same time the following week from when the button was pressed. The “Operating” LED
indicator will ash 3 times to conrm that the timer has been reset.
High Water Alarm
When the Alarm Test button is pressed, both the alarm indicators will light and the internal buzzer will sound.
When the Alarm Mute button is pressed, the internal buzzer will be silenced.
OPERATION
After installation and power up, the weekly timer will start and the blue Operating LED shall light at full
brightness.
After one week from initial power up (or after a 3 second press of the Set Button as described above), a test
will take place of the two pumps. During the test, both pumps will be separately tested with a 5 second period
between the two pump starts. Pump LED lights will show the test occurring.
The test process will repeat each week.
OPERATION OPERATION
SETUP SELECT
+
victron energy
BLU E PO W E R
BMV-600S
BATTERYMONITOR
BB5 Battery Monitor
18
victron energy
BL U E PO W E R
AC1
output
AC1
input
--
Pumps compatible with
MultiPlus 12/1200/50
CP400/NP400/NP400W
For Battery dimensions
please see drawings
prefixed Batt
Pump controller CP-9
JOHN NEWTON
&COMPANY LIMITED (EST. 1848)
High Water Alarm
WARNING
SHOCKHAZARD ISOLATE BOTH POWER SUPPLIES,
GRIDMAINS AND BATTERY BACK-UP POWER SUPPLY
BEFOREOPENING
Mute Test Test Set
Newton Pump Controller and High Water Alarm - PC9
Warning(See Manual)
HighWater Alarm
Operating
Pump1 On
Pump2 On
Pump Control
Pumps
High Water Alarm
Mains float
BMV shunt
500A/50mV
Pumps compatible with
MultiPlus 12/800/35
CP250
Multiplus Invertor
12/3000/120
12/1200/50
12/800/35
Pressure rated pipe. 50mm
internal including one way
valve and release
couplings - 50mm external.
Newton Titan-Pro
pumping system with
2 x NP400
fuse fuse
Main Earth
Section
NOTE: This is a waterproofing detail. For the design of the structure, please use a professional designer. We strongly recommend that Newton waterproofing systems are installed by our NSBC registered contractors who will guarantee,
insure and accept liability for both the design and the installation of our systems. Please refer to product data sheets before installation of our products. Newton Waterproofing Systems reserves the right to update drawings.
DO NOT SCALE
Checked by
Designed by
Date
Scale Drawing Reference
Drawn by
Original Reference Drawing Revision
17 - 20 Sovereign Way, Tonbridge, TN9 1RH
Tel: 01732 360095 Fax: 01732 359033
Notes
To access the details mentioned above,relevant NBS
Clauses, product data and MSDS sheets, please visit
Technical resources via
www.newtonwaterproofing.co.uk
®NEWTON
WATERPROOFING AJG AJG
AJG
P-07
28/06/17
Not to scale b
This drawings shows a Victron battery
back up system used in conjunction with
Newton System 500 Waterproofing
system incorporating titan pro white and
PC9 Control panel.
The Victron Inverter/Charger ensures
that water is still removed during power
outage until the battery is discharged.
Protection can be increased with
additional batteries.
For unlimited protection use the Quattro
12/3000/120 Generator system, this
recharges the battery(s) to give
unlimited protection if the fuel is
replenished.
For pump system specification please
contact out technical team or a Newton
specialist contractor.
Newton Dialler also available providing
warnings via a standard BT Telephone
line.
Newton System 500
Titan-Pro White pumping System with
battery back up.