Next TurboTAC Compact User manual

Installation, Operation
and Maintenance Manual
TurboTAC Salt-Free Limescale Prevention
and Water Filtration
Model: Compact
Installation, Operation
and Maintenance Manual
OneFlow+ Salt-Free Scale Prevention
and Water Filtration
Model OFPSYS
IOM-WQ-OneFlow+
OFPSYS
WARNING
!
Please read carefully before proceeding with
installation. Your failure to follow any attached
instructions or operating parameters may lead to the
product’s failure.
Keep this Manual for future reference.
If you are unsure about installing your WATTS water filter, contact
a WATTS representative or consult a professional plumber.
Test the water periodically to verify that the system is performing
satisfactorily. Discard small parts remaining after the installation.
Failure to install the system correctly voids the warranty.
Handle all components of the system with care. Do not drop,
drag or turn components upside down.
Be sure the floor under the water filter system is clean, level
and strong enough to support the unit.
IMPORTANT
CAUTION
!
NOTICE
WARNING
!
Untreated private well water may contain contaminants
with levels outside of the operating guidelines. Do not use
with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the
system.
OFPSYS OneFlow+™ system is certified
by the Water Quality Association (WQA) to
NSF/ANSI Standard 372 for lead free.
IOM-WQ-OneFlow+.indd 1 10/15/2015 11:22:12 PM
BS6920
CERTIFIED Certified to
NSF/ANSI 42/61
TurboTACCompact
Next Filtration / www.abtapdirect.com
IMPORTANT
If you are unsure about installing the lter, contact your supplier or consult a professional plumber.
NOTICE
Failure to install the system correctly voids the warranty. Handle all components of the system with care.
Do not drop, drag or turn components upside down. Use wall mounting bracket provided and x securely.
If installed on the oor, be sure the oor under the water lter system is clean, level and strong enough to
support the unit.
hard water, easy solution.

Introduction
Thank you for your purchase of the TurboTAC salt-
free limescale prevention and water ltration system.
This water treatment system has been designed and
tested to provide you with high quality drinking water
and limescale prevention for years to come.
System Parts
Installation Instructions
OneFlow+ Housing
Outlet Connector
OneFlow+ Head Assembly
1 MPT Threaded Inlet /
Outlet Adapters (x2)
Pressure Relief Valve
Inlet / Outlet red Adapter
Locking Pins (x2)
Sediment / Carbon Filter
Cartridge (20 microns)
OneFlow+ Scale Reduction
(TAC) Cartridge Multifunction Tool
Mounting Bracket
2
Introduction
Thank you for your purchase of Watts OneFlow+ salt-free scale
prevention and water ltration system. This Watts water treatment
system has been designed and tested to provide you with high qual-
ity drinking water fand scale prevention for years to come.
Installation Instructions
New systems come with the cartridges and outlet connector pre-installed. Installer
should verify this during installation.
1. Please confirm that all items required are included in the kit ready for assembly
and remove from carton.
2. Find a suitable location for the OneFlow+ system keeping in mind access to the
water supply and delivery to the home, restaurant or foodservice equipment.
3. The system can stand upright in the desired location without the need to affix
to a wall with a mounting bracket. However, a mounting bracket is available as a
separate part (Item 10)
4. Take the two 1”MPT Threaded Adapters (Item 5) and insert them into the inlet and
outlet of the OneFlow+ Housing (Item 1) as shown in Diagram A.
5. Secure these adapters with the two red adapter Locking Pins (Item 6) as shown in
Diagram A.
6. Take the Sediment/Carbon Filter cartridge (Item 7) and place it within the One-
Flow+ Housing (Item 1) as shown in Diagram B.
7. Take the OneFlow+ Scale reduction cartridge (Item 8) and secure it within the
centre of the Sediment/Carbon Filter cartridge (Item 7) as shown in Diagram C.
8. Take the Outlet Connector (Item 4) and install it as shown in Diagram D.
9. Take the OneFlow+ Head Assembly (Item 2) and screw this onto the OneFlow+
Housing (Item 1) as shown in Diagram E.
NOTICE
10. To tighten take the Multifunction Tool (Item 9] and tighten the Head Assembly as
shown in Diagram E by tightening in a clockwise direction – DO NOT OVER TI GHTEN
11. Using plumbing tape connect water supply to the inlet of the OneFlow+ system
and connect to the outlet of the OneFlow+ System as required.
12. Turn on water supply and check for leaks.
Diagram A
Diagram B
Diagram C
Diagram D
CLOSE
Diagram E
Diagram F
OPEN
Diagram G
Diagram H
OneFlow+ System Parts
NOTICE
IOM-WQ-OneFlow+.indd 2 10/15/2015 11:22:12 PM
Housing Head Assembly Pressure Relief Value
Outlet Connector Threaded Inlet / Outlet
Adapters (x2)
Inlet / Outlet Red Adapter
Looking Pins (x2)
Sediment / Carbon Filter
Cartridge (20 micorns)
Scale Reduction
(TAC) Cartridge Multifunction Tool
Mounting Bracket
New systems come with the cartridges and outlet connector pre-installed. Installer
should verify this during installation. When changing cartridges reverse installation
procedure and note items 6 & 7.
1. Please conrm that all items required are included in the kit ready for assembly and
remove from carton.
2. Find a suitable location for the installation keeping in mind access to the incoming
water supply and the treated supply to the home, restaurant or foodservice
equipment.
3. The system must stand upright in the desired location and secured using the wall
mounting bracket provided where possible.
4. Take the two threaded Adapters (Item 5) and insert them into the inlet and outlet of
the TurboTAC Housing (Item 1) as shown in Diagram A.
5. Secure these adapters with the two red adapter Locking Pins (Item 6) as shown in
Diagram A.
6. Take the Sediment/Carbon Filter cartridge (Item 7) and place it within the TurboTAC
Housing (Item 1) as shown in Diagram B.
7. Take the Next TAC Scale reduction cartridge (Item 8) and secure it within the centre
of the Sediment/Carbon Filter cartridge (Item 7) as shown in Diagram C.
8. Take the Outlet Connector (Item 4) and install it as shown in Diagram D.
9. Take the Head Assembly (Item 2) and screw this onto the Housing (Item 1) as
shown in Diagram E.
10. To tighten take the Multifunction Tool (Item 9] and tighten the Head Assembly as
shown in Diagram E by tightening in a clockwise direction – DO NOT OVER TIGHTEN
11. Using PTFE tape connect incoming water supply to the inlet of the TurboTAC
system and connect to the outlet as required to service the property.
12. Turn on water supply and check for leaks. Open rst cold water tap on the system
to release any air, and run the system for 5 minutes before putting into service.
OneFlow+ Housing
Outlet Connector
OneFlow+ Head Assembly
1 MPT Threaded Inlet /
Outlet Adapters (x2)
Pressure Relief Valve
Inlet / Outlet red Adapter
Locking Pins (x2)
Sediment / Carbon Filter
Cartridge (20 microns)
OneFlow+ Scale Reduction
(TAC) Cartridge Multifunction Tool
Mounting Bracket
2
Introduction
Thank you for your purchase of Watts OneFlow+ salt-free scale
prevention and water ltration system. This Watts water treatment
system has been designed and tested to provide you with high qual-
ity drinking water fand scale prevention for years to come.
Installation Instructions
New systems come with the cartridges and outlet connector pre-installed. Installer
should verify this during installation.
1. Please confirm that all items required are included in the kit ready for assembly
and remove from carton.
2. Find a suitable location for the OneFlow+ system keeping in mind access to the
water supply and delivery to the home, restaurant or foodservice equipment.
3. The system can stand upright in the desired location without the need to affix
to a wall with a mounting bracket. However, a mounting bracket is available as a
separate part (Item 10)
4. Take the two 1”MPT Threaded Adapters (Item 5) and insert them into the inlet and
outlet of the OneFlow+ Housing (Item 1) as shown in Diagram A.
5. Secure these adapters with the two red adapter Locking Pins (Item 6) as shown in
Diagram A.
6. Take the Sediment/Carbon Filter cartridge (Item 7) and place it within the One-
Flow+ Housing (Item 1) as shown in Diagram B.
7. Take the OneFlow+ Scale reduction cartridge (Item 8) and secure it within the
centre of the Sediment/Carbon Filter cartridge (Item 7) as shown in Diagram C.
8. Take the Outlet Connector (Item 4) and install it as shown in Diagram D.
9. Take the OneFlow+ Head Assembly (Item 2) and screw this onto the OneFlow+
Housing (Item 1) as shown in Diagram E.
NOTICE
10. To tighten take the Multifunction Tool (Item 9] and tighten the Head Assembly as
shown in Diagram E by tightening in a clockwise direction – DO NOT OVER TI GHTEN
11. Using plumbing tape connect water supply to the inlet of the OneFlow+ system
and connect to the outlet of the OneFlow+ System as required.
12. Turn on water supply and check for leaks.
Diagram A
Diagram B
Diagram C
Diagram D
CLOSE
Diagram E
Diagram F
OPEN
Diagram G
Diagram H
OneFlow+ System Parts
NOTICE
IOM-WQ-OneFlow+.indd 2 10/15/2015 11:22:12 PM
TurboTACCompact

Changing the Filter Cartridges
1. Turn o water supply at either the isolation tap or mains stop tap.
2. Use the Multifunction Tool (Item 9) to release air from the system.
This is done by taking the tool and unscrewing the Pressure Relief
Valve (Item 3) refer Diagram F.
3. Use Multifunction Tool (Item 9) to unscrew Head Assembly (Item 2))
anticlockwise and remove from the Housing as shown in Diagram G.
4. Remove Outlet Connector (Item 4) from top of Next ScaleStop (TAC)
Cartridge and remove from outlet port – refer Diagram D.
5. Use Multifunction Tool (Item 9) to remove TAC cartridge (Item 8) from
the Sediment/Carbon Cartridge (item 7) as shown in Diagram H.
6. Remove the Sediment/Carbon (item 7) from the Housing by hand.
7. Remove new Sediment/Carbon cartridge from packaging and place
carefully inside the TurboTAC Housing as shown in Diagram B.
8. Insert TAC cartridge back into the centre of the Sediment/ Carbon
cartridge making sure that it is sealed correctly as shown in Diagram C.
9. Insert Outlet Connector (item 4) into outlet port and secure back on
top of the TAC cartridge as shown in Diagram D.
10. Place Head Assembly back onto TurboTAC Housing and using the
multifunction tool tighten by screwing the Head Assembly clockwise as
shown in Diagram E. DO NOT OVER TIGHTEN.
11. Close the pressure relief valve by tightening in an anticlockwise
direction as shown in Diagram F.
12. Turn water supply on and check for leaks.
NOTICE
1. This system must be installed in accordance with local plumbing
regulations.
2. Where incoming water pressure exceeds 4.8 bar (70 psi) a suitable
pressure limiting valve must be installed in front of the TurboTAC unit.
3. The TurboTAC Compact is designed for use on public mains water
supply. Do not use with bore hole or well water that is of an unknown
quality without adequate pre ltration and/or disinfection before or after
the system.
4. Product performance is dependent upon incoming water supply quality.
5. The system must be installed and maintained in accordance with the
manufacturer’s instructions including replacement of the lter cartridges.
6. Please ensure all o-rings are well lubricated and clean from foreign
particles.
7. Please use PTFE tape or similar for all threaded connections.
Specications
OPERATING CONDITIONS
Water Flow: 37.8 lpm maximum
Incoming Water Temp: 4 - 30°C
Working Pressure: 1 bar – 4.8 bar, a pressure limiting valve
must be installed when pressure exceeds
4.8 bar (70psi).
Working Conditions: For indoor use – protection required when
installed outdoors.
254 mm (10”) x 254mm (10”) x 457mm (18”)Size:
Min Net Weight: 7 kgs
CONDITIONS FOR USE
pH: 6.5 to 8.5
Hardness, max: 1300ppm CaCO3
Chlorine: < 3 ppm
Iron, Ferrous: < 0.3 mg/L
Manganese: < 0.5 mg/L
Copper: < 1.3 mg/L
Oil & Phosphates: Zero
Hydrogen Sulde (H2S): Zero
CONTAMINATION TREATMENT
Sediment / Particulates: 20 microns with a dirt holding capacity up
Chlorine Reduction:
Scale Prevention:
CERTIFICATIONS
Next Scalestop TAC:
Carbon Filter:
to 1 kg (2.2 lbs)
189,000 litres @ 11.34 lpm * according to
lab test of carbon block manufacturer.
Up to 3 years
NSF/ANSI Standard 61
BS6920
NSF/ANSI Standard 42
Ordering Information
Complete System
7100638 COMPACTSYS Scale Prevention and Water Filter System
Water Filter Replacements
7100639 COMPACTRFC Radial Flow Carbon Block Cartridge
7100640 COMPACTSP Scale Prevention Cartridge
7100641 COMPACTCOM Combo Pack
System Replacement Parts
7300759 COMPACTHSG Housing and Head Assembly
7300760 COMPACTAP Inlet / Outlet Red Adapter Locking Pin
7300761 COMPACTA Inlet / Outlet Adapters
7300762 COMPACTOC Outlet Connector
7300763 COMPACTTOOL Multifunction Tool
7300759 COMPACTMB System Mounting Bracket
TurboTACCompact
Other Next Water Filtration System manuals
Popular Water Filtration System manuals by other brands

Graf
Graf MINIMAX 340060 Installation and maintenance instructions