Nice QUICK START INSTALLATION GUIDE Instruction Manual

1
MX4816-01 Rev. B ©2020 hysecurity.com • 800-321-9947
TITAN12L, 912L (w/936)
Swing Gate System
QUICK START
INSTALLATION
GUIDE
GATE
6”
11”
Weld or clamp pivot arm on gate hinge post for Pull-to-Open (left) or Push-to-Open (right).
Attach Actuator
to Pivot Arm Attach Actuator to
Gate Bracket
WASHERS
FIGURE 1: INSTALLATION OF ACTUATOR TO PIVOT ARM AND GATE BRACKET
GATE
BRACKET
912L ACTUATOR
ENSURE
LEVEL
PIVOT ARM
6”
13”
PIVOT ARM
PIVOT ARM
GATE
GATE
PIVOT ARM: Push-To-Open
PIVOT ARM: Pull-To-Open
ACTUATOR AND CONTROL BOX INSTALLATION:
HINGE
POST HINGE
POST
HINGE
HINGE
GATE BRACKET CENTERLINE
GATE BRACKET CENTERLINE
Pivot Arm
Top of Pivot Arm
TOP VIEW
TOP VIEW
FRONT VIEW
FRONT VIEW
1/2”
1/2”
Pivot
Arm
1B
1A
2
4
PULL-TO-OPEN:
Fully open gate,
then locate bracket
on gate support.
PUSH-TO-OPEN:
Fully close gate, then
locate bracket on
gate support.
Pull-To-Open
Push-To-Open
Bracket Position
Bracket Position
GATE OPEN
Ensure actuator arm is fully retracted, then position gate
bracket on gate structural support as shown below:
GATE CLOSED
TOP OF
PIVOT ARM
Afx Gate
Bracket to
gate struc-
tural support
by welding
or using
bolt/nut.
5
7 8
9
10
ical release open, manually
push gate to desired close
limit, then push to desired
open limit, and then push
to halfway open position.
Close mechanical release,
but do not lock.
actuator and minimum six feet
away from pivot arm (See FIG-
URE 2).
cable through rubber grom-
mets in bottom of control
box and wire per diagram
at right.
For dual gate, dig trench
across drive and run 2nd
actuator cable through con-
duit.
Open mechanical release on actuator.
2 31
6
3
CAUTION! Do NOT weld while control board is powered!
1/2”x
2-7/8”
PIVOT
BOLT
1/2”x3.5”
BOLT
LOCK NUT
LOCK
NUT
Manually Set Limits:
With actuator mechan-
Mount Control Box
same side as primary
Wire actuator to
control board: Pass
NOTE: Dual gate: wire Motor 1 and Motor 2 the same way.
EXTREMELY
IMPORTANT!
Read entire
manual before
attempting the
installation.
This is NOT a
“do-it-yourself”
project. Use a
qualied con-
tractor to install
this system.
Read all safety
information!
Place Battery inside
control box with ter-
minals facing toward the front.
CAUTION! Do not mount the control box where the person using
the push button on box can come in contact with the gate!
Push-To-OpenPull-To-Open
Orange
Orange
White
White
Green
Green
Blue
Blue
Yellow
Yellow
RedRed BlackBlack

2hysecurity.com • 800-321-9947 MX4816-01 Rev. B ©2020
TITAN12L, 912L (w/936)
Swing Gate System
QUICK START
INSTALLATION
GUIDE
CAUTION!
AC POWER
Actuator Cable
BlueBUS Wiring
Loop Wiring
Solar Panel Wiring
AC Power Wiring
6 foot min.
from pivot
install
Conduit for BlueBUS
and actuator cable
BlueBUS
Photo Eye
Open
Limit Safety
Loop
Open
Limit
Close
Limit
8
16
9
10
3
4
5
15
11 11
12
1
7
7
7
2
6
FIGURE 2: TYPICAL TITAN GATE SYSTEM (PULL-TO-OPEN, DUAL-GATE SHOWN)
FIGURE 3:
936 CON-
TROL BOARD
Button
OXI/A RX
Green LED
POWER
INPUTS
11
12
13 16
15
14
Install, and connect to con-
trol board, 100 feet max.
See 936 diagram below.
solar panel(s) to board. See 936
diagram below. If using option-
al AC-to-DC battery charger,
run AC power to charger/bat-
tery, but do NOT connect AC
power directly to the control
board!
hold OXI/A RX button until
green LED lights solid, then
release. b) Within 10 seconds,
press/hold any key on Nice TX
until green LED blinks 3 times.
c) Wait 15 sec. then press TX
buttons to verify operation.
accessories, such as safety
loops, strobes, photo eyes,
or other safety devices. See
FIGURE 3 below.
Determine BlueBUS
photo eye locations:
Attach warning
signs to gate.
To power 936 board,
connect battery and/or Program receiver and
transmitters: a) Press/
Connect audio alarm,
then connect other
Perform limit learn
procedure (below).
15
13
13
Antenna
Receiver
Close
GRD
OK
Open
Stop
Close
Open
+12V
Reset
BlueBus
GRD
+24V
N/C
COM
N/O
N/C
COM
N/O
GRD
GRD
12V
Alarm
Sol. Lock
Main Fuse
Limit 2
Encoder 2
Limit 1
Encoder 1
Motor 2Motor 1
3A
GRD
Reset
Edge
Safety
Shadow
Exit
UL
Fire
Input
GRD
GRD
GRD
GRD
GRD
GRD
GRD
GRD
GRD
+12V
Open
Input
USB
F/W Jumper
Learn
Input +12V a
Options
AutoClose
SlowDown
Force
Close
Stop
+12V
c
3A
b
c
Bypass 15A Fuse
A
A B
A
BA B
A B
B
Close
Close
Open
OpenOpen
COM
COM
Battery
Solar
3A
c
b
OPEN
DOWN
OK
UP
Display
MOTOR 1
MOTOR 1
Encoder LED
Open Limit LED
Close Limit LED
MOTOR 2
Encoder LED
Open Limit LED
Close Limit LED
MOTOR 2
STOP
CLOSE
RESET Button
Exit
Edge
Entrap
Shadow
Safety
OXI/A Plugin
Radio Receiver
BlueBUS Connector
Press &
hold Learn
button 8-10s
Release
when ash-
ing stops.
...Then stops
ashing after
8-10s.
Display ashes
“Lr” while
pressing...
“Lr”glows solid.
See Step 3 in
Limit Learn pro-
cedure at right.
GATE LIMIT LEARN PROCEDURE:
1. Test Gate Conditions: Mechanically disengage actuator(s)
from gate and move to open/close positions and check for
free travel without binding, then reconnect actuator(s) to
gate.
2. Connect Power: See INSTRUCTION 13, above.
3. Enter Learn Mode (see FIGURE 4): NOTE: When in Learn
Mode, “OPEN” and “CLOSE” buttons must be held down
to operate gate. Complete Step 4 (below) for each actu-
ator/gate individually (disconnect cable for actuator NOT
being adjusted). Reconnect both actuators prior to Step 5.
4. Adjust Limit Location: a) Hold down “OPEN” button until
desired open position reached (If motion is opposite than
desired, switch RED and BLACK wires at motor input). b)
Adjust open limit until Open Limit LED lights. If Close Limit
LED lights, switch ORANGE & WHITEWHITE wires at terminal
block. c) Hold down “CLOSE” button until desired close
position. d) Adjust close limit until Close Limit LED lights. e)
Hold down “OPEN” until gate at middle of travel. Connect
both actuator cables to control board if dual gate system.
5. Commence Limit Learn: In Learn Mode (with “Lr” still glow-
ing) press “OK” and the following events will occur: a) Par-
tial open. b) Slow travel in close direction. c) Slow travel in
open direction. d) Full speed in close direction.
Basic limit programming is complete. See the manual for ad-
ditional programming.
Safety
Device
Connect Audio
Alarm
+
FIGURE 3: 936
Control Board
Antenna
Receiver
Close
GRD
OK
Open
Stop
Close
Open
+12V
Reset
BlueBus
GRD
+24V
N/C
COM
N/O
N/C
COM
N/O
GRD
GRD
12V
Alarm
Sol. Lock
Main Fuse
Limit 2
Encoder 2
Limit 1
Encoder 1
Motor 2Motor 1
3A
GRD
Reset
Edge
Safety
Shadow
Exit
UL
Fire
Input
GRD
GRD
GRD
GRD
GRD
GRD
GRD
GRD
GRD
+12V
Open
Input
USB
F/W Jumper
Learn
Input +12V a
Options
AutoClose
SlowDown
Force
Close
Stop
+12V
c
3A
b
c
Bypass 15A Fuse
A
A B
A
BA B
A B
B
Close
Close
Open
OpenOpen
COM
COM
Battery
Solar
3A
c
b
Antenna
Receiver
Close
GRD
OK
Open
Stop
Close
Open
+12V
Reset
BlueBus
GRD
+24V
N/C
COM
N/O
N/C
COM
N/O
GRD
GRD
12V
Alarm
Sol. Lock
Main Fuse
Limit 2
Encoder 2
Limit 1
Encoder 1
Motor 2Motor 1
3A
GRD
Reset
Edge
Safety
Shadow
Exit
UL
Fire
Input
GRD
GRD
GRD
GRD
GRD
GRD
GRD
GRD
GRD
+12V
Open
Input
USB
F/W Jumper
Learn
Input +12V a
Options
AutoClose
SlowDown
Force
Close
Stop
+12V
c
3A
b
c
Bypass 15A Fuse
A
A B
A
BA B
A B
B
Close
Close
Open
OpenOpen
COM
COM
Battery
Solar
3A
c
b
LEARN
FORCE
SLOWDOWN
AUTOCLOSE
OPTIONS
Solar
Panel
12VDC
Battery
FIGURE 4: ENTERING LEARN MODE (936 BOARD)
Other Nice Fencing & Gate manuals
Popular Fencing & Gate manuals by other brands

Motorline
Motorline FLAMA User's and installer's manual

Barrette
Barrette HEAVY-DUTY DROP ROD installation instructions

Summer Fun
Summer Fun 2700600 Directions for use

PERCo
PERCo WMD-06 Assembly and operation manual

RYTEC
RYTEC Turbo-Seal installation manual

Casanoov
Casanoov KIT-000082 Assembly instructions