FORM NO. 56041556 - Retriever™6250 / SR 1800 - A-19
ENGLISH / A-19
TROUBLESHOOTING
If the possible causes listed below are not the source of trouble, it is a symptom
of something more serious. Contact your Nilfisk-Advance Service Center
immediately for service.
TRIPPING THE CIRCUIT BREAKERS
The circuit breakers are located on the Circuit Breaker Panel (33), they protect
electricalcircuits and motors from damageduetooverload conditions. If a circuit
breaker trips, try to determine the cause.
Shaker Motor Circuit Breaker (8 Amp) Possible causes may be:
1Electrical short circuit (have your Nilfisk-Advance Service Center or
qualified electrician check the machine)
2Overloaded or jammed shaker motor (check shaker motor)
Accessory Circuit 1 Circuit Breaker (15 Amp) Possible cause may be:
1Electrical short circuit (have your Nilfisk-Advance Service Center or
qualified electrician check the machine)
Ignition Circuit Circuit Breaker (15 Amp) Possible cause may be:
1Electrical short circuit (have your Nilfisk-Advance Service Center or
qualified electrician check the machine)
Horn Circuit Breaker (10 Amp) Possible cause may be:
1Electrical short circuit (have your Nilfisk-Advance Service Center or
qualified electrician check the machine)
Headlight / Tail Light Circuit Breaker (20 Amp) Possible cause may be:
1Electrical short circuit (have your Nilfisk-Advance Service Center or
qualified electrician check the machine)
Main Circuit Breaker (40 Amp) Possible cause may be:
1Electrical short circuit (have your Nilfisk-Advance Service Center or
qualified electrician check the machine)
Once the problem has been corrected, push the button in to reset the circuit
breaker. If the button does not stay in, wait 5 minutes and try again. If the circuit
breaker trips repeatedly, call your Nilfisk-Advance Service Center for service.
TROUBLESHOOTING
If the possible causes listed below are not the source of trouble, it is a symptom
of something more serious. Contact your Nilfisk-Advance Service Center
immediately for service.
MACHINE WILL NOT MOVE
Possible causes may be:
1Parking Brake (3) set (release parking brake)
2Towing Valve in wrong position (set correctly)
3Tripped circuit breaker(s) (reset any tripped circuit breakers)
MAIN BROOM WILL NOT RUN
Possible causes may be:
1Hopper door is not open (open hopper door)
2Debris wrapped around the broom drive (remove debris)
3Hopper is not completely down (lower hopper completely)
4Tripped circuit breaker(s) (reset any tripped circuit breakers)
SIDE BROOM WILL NOT RUN
Possible causes may be:
1Hopper door is not open (open hopper door)
2Debris wrapped around the broom drive (remove debris)
3Hopper is not completely down (lower hopper completely)
4Tripped circuit breaker(s) (reset any tripped circuit breakers)
HOPPER WILL NOT RAISE
Possible causes may be:
1Tripped circuit breaker(s) (reset any tripped circuit breakers)
HOPPER DUMP DOOR WILL NOT OPEN
Possible causes may be:
1Dump door jammed by debris (remove debris and clean edges of dirt
chamber)
2Tripped circuit breaker(s) (reset any tripped circuit breakers)
SHAKER MOTOR WILL NOT RUN
Possible causes may be:
1Tripped circuit breaker(s) (reset any tripped circuit breakers)
DUST CONTROL SYSTEM (IMPELLER) WILL
NOT RUN
Possible causes may be:
1Tripped circuit breaker(s) (reset any tripped circuit breakers)
TECHNICAL SPECIFICATIONS (as installed and tested on the unit)
Model SR 1800(DU) Retriever™6250 / SR 1800(G) Retriever™6250 / SR 1800(P)Retriever™6250 / SR 1800(D)
Model No. 56418006 56419421 / 56418005 56419420 / 56418004 56419422 / 56418007
Sound Power Level (ISO 3744) dB(A)/20µPa 85 85 85 85
Total Weight lbs/kg 4,201 / 1,905 4,201 / 1,905 4,201 / 1,905 4,201 / 1,905
Tire Pressure psi 90 90 90 90
Vibrations at the Hand Controls m/s2<2.5 m/s2<2.5 m/s2<2.5 m/s2<2.5 m/s2
Vibrations at the Seat m/s2<0.5 m/s2<0.5 m/s2<0.5 m/s2<0.5 m/s2
Gradeability 26.8% (150)26.8% (150)26.8% (150)26.8% (150)