PN 30018 REV 1 NimbeLink Corp All Rights Reserved. 1
Skywire™ RL78/Kurumi Adapter
User Manual
NimbeLink Corp
Published: September 2014
2 / 12
2 / 12

Distributor of NimbeLink, LLC: Excellent Integrated System Limited
Datasheet of NL-AB-PMOD - DEV ADAPTER KIT RENESAS RL78
PN 30018 REV 1 NimbeLink Corp All Rights Reserved. 2
Contents
1. INTRODUCTION........................................................................................................................................ 3
1.1 PRODUCT OVERVIEW ............................................................................................................................................3
1.2 ORDERABLE PARTS ...............................................................................................................................................3
1.3 ADDITIONAL RESOURCES........................................................................................................................................3
1.4 DEVICE OVERVIEW ...............................................................................................................................................4
2. DEVICE DESCRIPTION ............................................................................................................................... 5
2.1 TECHNICAL SPECIFICATIONS....................................................................................................................................5
2.1.1 Operating Parameters ...........................................................................................................................5
2.1.2 Power .....................................................................................................................................................5
2.1.3 Connection Descriptions ........................................................................................................................6
3. OPERATING MODES ................................................................................................................................. 7
3.1 RL78/G13 DEMONSTRATION KIT PMOD ADAPTER...................................................................................................7
3.1.1 About .....................................................................................................................................................7
3.1.2 Block Diagram........................................................................................................................................7
3.1.3 Switch configuration ..............................................................................................................................8
3.1.4 Connections............................................................................................................................................8
3.1.5 SPI to UART Chip Configuration .............................................................................................................8
3.1.6 Board Orientation ..................................................................................................................................9
3.2 RENESAS KURUMI ADAPTER .................................................................................................................................10
3.2.1 About ...................................................................................................................................................10
3.2.2 Block Diagram......................................................................................................................................10
3.2.3 Switch configuration ............................................................................................................................10
3.2.4 Connections..........................................................................................................................................11
3.2.5 Board Orientation ................................................................................................................................11
3 / 12
3 / 12

Distributor of NimbeLink, LLC: Excellent Integrated System Limited
Datasheet of NL-AB-PMOD - DEV ADAPTER KIT RENESAS RL78
PN 30018 REV 1 NimbeLink Corp All Rights Reserved. 3
1. Introduction
1.1 Product Overview
This document is the Hardware Reference Manual for the Skywire™ RL78/Kurumi
Adapter. The Skywire™ RL78/Kurumi Adapter is designed to provide robust
cellular connectivity for the Renesas RL78/G13 Demonstration Kit and the
Renesas Kurumi.
The Skywire Cellular Modem at the heart of this adapter connects your M2M
device to the Internet of things without the costs, delays, and hassles of federal
and carrier certifications.
The NimbeLink Skywire™ modem is available with bundled data plans from
leading cellular carriers.
1.2 Orderable Parts
Orderable Part
Number
Description
Manufacturer
Carrier
Network
Type
NL-AB-RL78
Skywire RL78/Kurumi Adapter Board
Nimbelink
NL-SW-1XRTT-V
Skywire 1xRTT Cellular Modem without
data plan. 2G Modem.
Nimbelink
Verizon
CDMA
1xRTT
TG.30.8113
Primary & Diversity Cellular Antenna
Taoglas
NL-SW-EVDO-V
Skywire EVDO Cellular Modem without
Data plan. 3G Modem.
Nimbelink
Verizon
CDMA
EVDO
MA.301.A.AB.001
3G Primary Antenna. GPS/GLONASS
Antenna for Skywire EVDO*
Taoglas
*Antenna is a dual cellular & GPS antenna
1.3 Additional Resources
Nimbelink's Skywire2G 1xRTT Product Page
Nimbelink's Skywire 3G CDMA/EVDO Product Page
Telit’s CE910 Hardware User Guide
Telit’s DE910 Hardware User Guide
4 / 12
4 / 12

Distributor of NimbeLink, LLC: Excellent Integrated System Limited
Datasheet of NL-AB-PMOD - DEV ADAPTER KIT RENESAS RL78
PN 30018 REV 1 NimbeLink Corp All Rights Reserved. 4
1.4 Device Overview
Top Side
Bottom Side
5 / 12
5 / 12

Distributor of NimbeLink, LLC: Excellent Integrated System Limited
Datasheet of NL-AB-PMOD - DEV ADAPTER KIT RENESAS RL78
PN 30018 REV 1 NimbeLink Corp All Rights Reserved. 5
2. Device Description
2.1 Technical Specifications
2.1.1 Operating Parameters
2.1.2 Power
The Skywire RL78/Kurumi Adapter requires 5V and 3.3V inputs. Connector J1
accepts 5V input voltage and is used to supply power to the Skywire 4V Power
Supply. The acceptable input Voltage range for J1 is 4.8-5.2V. Do not exceed
5.5V.
The Skywire Cellular Modem will regularly consume high amounts of current
(~750 mA) from the adapters power supply. It is recommended to have 1A of
available source current available for the adapter board.
Operating Parameters
Skywire UART Baud Rate
115200 bps
Skywire I/O Voltage
1.65V-5.5V
Skywire Power Consumption
Active Call
750 mA
Normal
29 mA
Power
Saving
1.1 mA
Skywire Input Voltage
4V
J1 Input Voltage
5V
PMOD Input Voltage
3.3V
PMOD I/O Voltage
3.3V
Kurumi Input Voltage
4V
Kurumi I/O Voltage
4V
Temperature Range
-40 to 85C
Dimensions
47mm x 82mm x 25mm
6 / 12
6 / 12

Distributor of NimbeLink, LLC: Excellent Integrated System Limited
Datasheet of NL-AB-PMOD - DEV ADAPTER KIT RENESAS RL78
PN 30018 REV 1 NimbeLink Corp All Rights Reserved. 6
2.1.3 Connection Descriptions
Connection Descriptions
Designator
Description
SW1
Mode Selection Switch
J1
5V Power IN, Barrel Jack
J2
Skywire Breakout Header
J3
Skywire Breakout Header
J4
PMOD Connector
J5
Current Test Point
J6
Skywire Breakout Header
J7
Renesas Kurumi Breakout Header
J8
Renesas Kurumi Breakout Header
J9
Renesas Kurumi Programming Header
U4
Renesas Kurumi Socket
7 / 12
7 / 12

Distributor of NimbeLink, LLC: Excellent Integrated System Limited
Datasheet of NL-AB-PMOD - DEV ADAPTER KIT RENESAS RL78
PN 30018 REV 1 NimbeLink Corp All Rights Reserved. 7
3. Operating Modes
3.1 RL78/G13 Demonstration Kit PMOD Adapter
3.1.1 About
The PMOD interface on the Skywire RL78-Kurumi Adapter adheres to the Digilent
PMOD specifications for Type 2A (Expanded SPI) PMOD Interface with a standard
twelve-pin connector.
The PMOD interface connects to the Renesas Demonstration Kit for the
RL78/G13 (YRDKRL78G13) through the PMOD2 connector. The adapter’s
onboard SPI to UART converter provides protocol translation allowing for the
demonstrations kits Type 2A (Expanded SPI) PMOD Interface to communicate
with the Skywire module.
3.1.2 Block Diagram
8 / 12
8 / 12

Distributor of NimbeLink, LLC: Excellent Integrated System Limited
Datasheet of NL-AB-PMOD - DEV ADAPTER KIT RENESAS RL78
PN 30018 REV 1 NimbeLink Corp All Rights Reserved. 8
3.1.3 Switch configuration
SW1 is used to control the configuration mode of the adapter. To configure the
adapter for use with the PMOD connection do the following:
1. Remove power from J1 and the PMOD connection.
2. Place SW1.1-SW1.5 in the on position.
3. Place SW1.6 in the off position.
4. Configuration complete.
3.1.4 Connections
The Skywire RL78-Kurumi Adapter connects to the RL78/G13 through a Type 2A
(Expanded SPI) PMOD Interface. The table below describes the connections.
PMOD Connections
PIN
Signal
Description
1
SS
Slave Select. Active low to enable slave device
2
MOSI
Master Out Slave In. Data from master to slave
3
MISO
Master In Slave Out. Data from slave to master
4
SCK
Serial clock. Master provides the clock to shift the data
5
GND
6
VCC
7
INT
Interrupt signal from slave to master, connected to the
SPI to UART converter chip
8
RESET
Reset signal for master to reset SPI to UART converter
9
Skywire On
Off
Skywire On Off control line
10
Skywire DTR
Skywire DTR signal
11
GND
12
VCC
3.1.5 SPI to UART Chip Configuration
To configure the XR20M1170 SPI to UART interface for communication between
the PMOD interface (SPI) and the Skywire Cellular Modem (UART, 115200 bps)
use the configuration sequence in the table below. The SPI interface from the
host processor should be configured to SPI MODE0, most Significant bit first, and
the clocking rate must be 16 MHz or lower.
9 / 12
9 / 12

Distributor of NimbeLink, LLC: Excellent Integrated System Limited
Datasheet of NL-AB-PMOD - DEV ADAPTER KIT RENESAS RL78
PN 30018 REV 1 NimbeLink Corp All Rights Reserved. 9
For additional information on the XR20M1170 visit the XR20M1170 product
page.
3.1.6 Board Orientation
The adapter should be connected to the RL78/G13 Demonstration kit with the
Skywire modem facing towards the demonstration kit as shown below or with a
right angle adaptor with the Skywire Modem facing upwards.
XR20M1170 SPI to UART Register Configuration
Configuration
Step
Register
Register
Address
Value
Notes
1
LCR
0x03
0xBF
Configure LCR for EFR write
2
EFR
0x02
0x10
Configure EFR
3
LCR
0x03
0xB0
Configure LCR for Baud rate config
4
DLL
0x00
0x08
Configure baud rate for 115200 bps
5
DLM
0x01
0x00
Configure baud rate for 115200 bps
6
DLD
0x02
0x00
Configure baud rate for 115200 bps
7
MCR
0x04
0x03
Configure clock prescaler
8
LCR
0x03
0xBF
Write LCR for EFR write
9
EFR
0x02
0x00
Disable config mode
10
LCR
0x03
0x03
Reset LCR for operation mode
11
FCR
0x02
0x07
Enable and clear FIFOs
10 / 12
10 / 12

Distributor of NimbeLink, LLC: Excellent Integrated System Limited
Datasheet of NL-AB-PMOD - DEV ADAPTER KIT RENESAS RL78
PN 30018 REV 1 NimbeLink Corp All Rights Reserved. 10
3.2 Renesas Kurumi Adapter
3.2.1 About
The Renesas Kurumi interface on the Skywire RL78-Kurumi Adapter provides a
UART connection between the two boards.
3.2.2 Block Diagram
3.2.3 Switch configuration
SW1 is used to control the configuration mode of the adapter. To configure the
adapter for use with the Renesas Kurumi do the following:
1. Remove power from J1 and the PMOD connection.
2. Place SW1.1-SW1.5 in the off position.
3. Place SW1.6 in the on position.
4. Configuration complete.
11 / 12
11 / 12

Distributor of NimbeLink, LLC: Excellent Integrated System Limited
Datasheet of NL-AB-PMOD - DEV ADAPTER KIT RENESAS RL78
PN 30018 REV 1 NimbeLink Corp All Rights Reserved. 11
3.2.4 Connections
The following table shows the connections between the Nimbelink Skywire
Cellular Modem and the Renesas Kurumi.
Kurumi
Pin
Signal
Description
2
Skywire DTR
Skywire Data Terminal Ready Signal
4
Skywire On Off
Skywire On/Off control line
5
Skywire CTS
Skywire Clear to Send
6
Skywire RTS
Skywire Ready to Send
7
Skywire DIN
Skywire UART data in
8
Skywire DOUT
Skywire UART data out
3.2.5 Board Orientation
The Renesas Kurumi board should be attached with the programming header
aligned with the programming header breakout pins(J9) on the adapter board.
Powered by TCPDF (www.tcpdf.org)
Powered by TCPDF (www.tcpdf.org) 12 / 12
12 / 12
Table of contents
Other NimbeLink Adapter manuals
Popular Adapter manuals by other brands

AJA
AJA mini-connect Installation & operation guide

Lectrosonics
Lectrosonics Quadpack instruction manual

A.E.B.
A.E.B. Leonardo 175 Fitting Instructions and Guarantee workbook

KLINDEX
KLINDEX PLANETARI NEW Manual book

RaidSonic
RaidSonic IB-MP305A-B Brochure & specs

D-Link
D-Link DWL-P50 Quick installation guide