nodon SIN-2-2-01 User manual

N L
USER GUIDEEN APPROVALS AND CERTIFICATIONS
INSTALLATION
*
Or
Or
Reference: SIN-2-2-01
Power supply: 230V AC ~ 50Hz
Switching capabilities: 230V AC - 2 x 5A
Consumption: <1W
Maximum output power: 2 x 1150W (Resistive load)
List of compatible loads available on nodon.fr/loads
Radio frequency range: 868.0 to 868.6 Mhz
RF power max: +3dBm
Range: up to 30m indoor
Operational temperature: -10°C to 40°C
Protection rating: IP 30
Pairing: up to 22 controllers
EEP (EnOcean Prole): D2-01-12
Dimensions: 40 mm (l) x 44 mm (L) x 16.9 mm (h)
Weight: 34 g
Warranty: 2 years
ON/OFF LIGHTING
RELAY SWITCH
CONTACT AFTER SALES SERVICE
USE CAUTIONS
• Never use the device if it is not correctly installed and
placed inside a connecting box in conformity with the
current norms.
• Keep the product far away from liquids.
nodon.fr/en/“support” section
NodOn SAS
121 rue des Hêtres
45590 St CYR EN VAL
(FRANCE)
This product is conform to EnOcean radio protocol.
This product must be used indoor only.
The presence of this symbol on a product indicates
that this one is conform to the European directive
2012/19/UE. Find out more about the provisions in
force in your region regarding the separate collection
of electrical and electronical devices. Respect the local rules and
do not throw out the product with common domestic wastes.
The correct rejection of ancient products allows to preserve the
environment and health.
Hereby, NodOn SAS declares that this radio equipment
is conform to the RED directive 2014/53/UE. The
integral text of the EU declaration of conformity
is available at the following online address: nodon.fr/en/
”support” section.
DANGER OF ELECTROCUTION
BEFORE ANY INSTALLATION MAKE SURE
THE POWER SUPPLY IS DISCONNECTED
TO AVOID ANY RISK OF ELECTROCUTION.
Directly cut the power supply from the breaker box to avoid
any risk of electrocution. This relay switch is designed to
be used power up, a wrong installation can create a re or
an electric shock. If you are not condent about electrical
installation, please ask a professional.
The relay switch must be installed and connected carefully
following the instructions of this user guide. We will not be
responsible for any loss or damage resulting from a non-
respect of the instructions of this user guide. Cut the power
supply before any operation and don’t do any modication
if the LED is still ON.
Thanks to its small size, the ON/OFF Lighting
Relay Switch can be installed anywhere in the
wall or the ceiling (behind an existing wall
switch, in a false ceiling, etc…).
Add the ON/OFF Lighting Relay Switch to the
electric panel with NodOn DIN Rail Box*.
*Optional accessory
RELAY SWITCH INPUT/OUTPUT
Each terminal can accept a cable of 2.5mm² maximum, stripped
of 8mm.
NTerminal for the Neutral
LTerminal for the Line
Input terminal
for the wired switch 1*
Input terminal
for the wired switch 2*
Output 1 (controlled by )
Output 2 (controlled by )
*Wired switch optional (see the installation diagrams section)
INSTALLATION DIAGRAM FOR ONE
OR TWO LIGHTS
Wiring with one or two ways
*Wired switch optional (see the installation diagrams section)
After turning the power supply ON, do a single push on the wired
wall switch. The relay switch has an auto-detection system to
automatically detect the type of wired wall switch (rocker or
push-button) wired at the input.
Note: The same configuration is applied for both inputs
( and ). It is not possible to combine a rocker switch
with a push-button. To perform a new auto-detection,
the ON/OFF Lighting Relay Switch must be manually reset
(see reset procedure).
AUTO-DETECTION OF SWITCH TYPE
PAIRING PROCEDURE
Note: if the LED blinks orange during the pairing procedure, it
means that more than 22 controllers are paired and that no more
controller can be paired. You must remove one controller to add
a new one.
Continue with steps 2 and 3a/3b to pair your controller.
USE OF YOUR SOFT BUTTON
The Soft Button will work as follows:
For more details on how to pair
a home automation gateway or
other compatible products, please
consult the “Support” section on
nodon.fr/en/
PAIRING
WITH A HOME AUTOMATION GATEWAY
UNPAIRING PROCEDURE
RESET PROCEDURE
DETAILED
USER GUIDE
Directly access the detailed user
guide on the Support section
on nodon.fr/en/technical-
support/
N L
N L
N L
N L N L
Types of press Action
Single press Reversal
Double press ON
Long press OFF
1 Cut the power supply
2 Dismantle the wired switch
controlling the light(s) you want
to connect.
3 Install the ON/OFF Lighting Relay
Switch according to diagram gure 1.
4 Reinstall the wired switch.
5 Turn the power supply back ON.
Figure 1
To add a remote or a wall switch or the Soft Button (EnOcean
compatible) you must enter the pairing mode, your light must be
switched OFF.
Relay switch must be power supplied.
Launch the pairing by doing 3 consecutive presses on
the relay switch button. The LED blinks red.
FOR CHANNEL 1 ( / )
Two modes:
1. From the module
You have now 30
seconds to pair your Soft
Button by doing 5 brief
consecutive presses on
the button.
You have 30 seconds to
pair your controller by briefly
pressing (in less than a second)
on the button of your choice,
this one will turn the light ON
for the channel 1, the opposite
button will turn it OFF.
Action the wired wall switch 3 times (in less than a
second). The lighting connected in blinks, meaning that
the channel 1 ( / ) is in “pairing/unpairing mode”.
2. From the wired wall switch
The LED of the relay
switch will blink green twice,
conrming the pairing of the
two devices.
The light stops to blink,
conrming the pairing of the
two devices.
Launch the pairing by doing 3 consecutive presses on the
relay switch button. The LED blinks red. Wait 1 second and do
a new press on the relay switch button.
FOR THE CHANNEL 2 ( / )
Two modes
1. From the relay switch
Press the wall switch 3 times (in less than a second).
Wait 1 second and do a new press on the wall switch. The light
connected in blinks, meaning that the channel 2 ( / )
is in “Pairing/Unpairing” mode.
2. From the wired wall switch
Do the same procedure as pairing (see “pairing procedure”) and
takes care of pressing the button chosen to control your gate/
garage door/electric latch or your electrical outlet.
Relay switch must be power supplied.
1 Press more than 5 seconds on your module’s button.
The LED blinks orange.
2 Press once again the button (short press) to conrm the
reset. If the reset is correct, the LED blinks alternatively in red
and green and stays green. Start again if necessary.
3 Your module has now its original settings.
TIP
N L
USER GUIDEEN APPROVALS AND CERTIFICATIONS
INSTALLATION
*
Or
Or
Reference: SIN-2-2-01
Power supply: 230V AC ~ 50Hz
Switching capabilities: 230V AC - 2 x 5A
Consumption: <1W
Maximum output power: 2 x 1150W (Resistive load)
List of compatible loads available on nodon.fr/loads
Radio frequency range: 868.0 to 868.6 Mhz
RF power max: +3dBm
Range: up to 30m indoor
Operational temperature: -10°C to 40°C
Protection rating: IP 30
Pairing: up to 22 controllers
EEP (EnOcean Prole): D2-01-12
Dimensions: 40 mm (l) x 44 mm (L) x 16.9 mm (h)
Weight: 34 g
Warranty: 2 years
ON/OFF LIGHTING
RELAY SWITCH
CONTACT AFTER SALES SERVICE
USE CAUTIONS
• Never use the device if it is not correctly installed and
placed inside a connecting box in conformity with the
current norms.
• Keep the product far away from liquids.
nodon.fr/en/“support” section
NodOn SAS
121 rue des Hêtres
45590 St CYR EN VAL
(FRANCE)
This product is conform to EnOcean radio protocol.
This product must be used indoor only.
The presence of this symbol on a product indicates
that this one is conform to the European directive
2012/19/UE. Find out more about the provisions in
force in your region regarding the separate collection
of electrical and electronical devices. Respect the local rules and
do not throw out the product with common domestic wastes.
The correct rejection of ancient products allows to preserve the
environment and health.
Hereby, NodOn SAS declares that this radio equipment
is conform to the RED directive 2014/53/UE. The
integral text of the EU declaration of conformity
is available at the following online address: nodon.fr/en/
”support” section.
DANGER OF ELECTROCUTION
BEFORE ANY INSTALLATION MAKE SURE
THE POWER SUPPLY IS DISCONNECTED
TO AVOID ANY RISK OF ELECTROCUTION.
Directly cut the power supply from the breaker box to avoid
any risk of electrocution. This relay switch is designed to
be used power up, a wrong installation can create a re or
an electric shock. If you are not condent about electrical
installation, please ask a professional.
The relay switch must be installed and connected carefully
following the instructions of this user guide. We will not be
responsible for any loss or damage resulting from a non-
respect of the instructions of this user guide. Cut the power
supply before any operation and don’t do any modication
if the LED is still ON.
Thanks to its small size, the ON/OFF Lighting
Relay Switch can be installed anywhere in the
wall or the ceiling (behind an existing wall
switch, in a false ceiling, etc…).
Add the ON/OFF Lighting Relay Switch to the
electric panel with NodOn DIN Rail Box*.
*Optional accessory
RELAY SWITCH INPUT/OUTPUT
Each terminal can accept a cable of 2.5mm² maximum, stripped
of 8mm.
NTerminal for the Neutral
LTerminal for the Line
Input terminal
for the wired switch 1*
Input terminal
for the wired switch 2*
Output 1 (controlled by )
Output 2 (controlled by )
*Wired switch optional (see the installation diagrams section)
INSTALLATION DIAGRAM FOR ONE
OR TWO LIGHTS
Wiring with one or two ways
*Wired switch optional (see the installation diagrams section)
After turning the power supply ON, do a single push on the wired
wall switch. The relay switch has an auto-detection system to
automatically detect the type of wired wall switch (rocker or
push-button) wired at the input.
Note: The same configuration is applied for both inputs
( and ). It is not possible to combine a rocker switch
with a push-button. To perform a new auto-detection,
the ON/OFF Lighting Relay Switch must be manually reset
(see reset procedure).
AUTO-DETECTION OF SWITCH TYPE
PAIRING PROCEDURE
Note: if the LED blinks orange during the pairing procedure, it
means that more than 22 controllers are paired and that no more
controller can be paired. You must remove one controller to add
a new one.
Continue with steps 2 and 3a/3b to pair your controller.
USE OF YOUR SOFT BUTTON
The Soft Button will work as follows:
For more details on how to pair
a home automation gateway or
other compatible products, please
consult the “Support” section on
nodon.fr/en/
PAIRING
WITH A HOME AUTOMATION GATEWAY
UNPAIRING PROCEDURE
RESET PROCEDURE
DETAILED
USER GUIDE
Directly access the detailed user
guide on the Support section
on nodon.fr/en/technical-
support/
N L
N L
N L
N L N L
Types of press Action
Single press Reversal
Double press ON
Long press OFF
1 Cut the power supply
2 Dismantle the wired switch
controlling the light(s) you want
to connect.
3 Install the ON/OFF Lighting Relay
Switch according to diagram gure 1.
4 Reinstall the wired switch.
5 Turn the power supply back ON.
Figure 1
To add a remote or a wall switch or the Soft Button (EnOcean
compatible) you must enter the pairing mode, your light must be
switched OFF.
Relay switch must be power supplied.
Launch the pairing by doing 3 consecutive presses on
the relay switch button. The LED blinks red.
FOR CHANNEL 1 ( / )
Two modes:
1. From the module
You have now 30
seconds to pair your Soft
Button by doing 5 brief
consecutive presses on
the button.
You have 30 seconds to
pair your controller by briefly
pressing (in less than a second)
on the button of your choice,
this one will turn the light ON
for the channel 1, the opposite
button will turn it OFF.
Action the wired wall switch 3 times (in less than a
second). The lighting connected in blinks, meaning that
the channel 1 ( / ) is in “pairing/unpairing mode”.
2. From the wired wall switch
The LED of the relay
switch will blink green twice,
conrming the pairing of the
two devices.
The light stops to blink,
conrming the pairing of the
two devices.
Launch the pairing by doing 3 consecutive presses on the
relay switch button. The LED blinks red. Wait 1 second and do
a new press on the relay switch button.
FOR THE CHANNEL 2 ( / )
Two modes
1. From the relay switch
Press the wall switch 3 times (in less than a second).
Wait 1 second and do a new press on the wall switch. The light
connected in blinks, meaning that the channel 2 ( / )
is in “Pairing/Unpairing” mode.
2. From the wired wall switch
Do the same procedure as pairing (see “pairing procedure”) and
takes care of pressing the button chosen to control your gate/
garage door/electric latch or your electrical outlet.
Relay switch must be power supplied.
1 Press more than 5 seconds on your module’s button.
The LED blinks orange.
2 Press once again the button (short press) to conrm the
reset. If the reset is correct, the LED blinks alternatively in red
and green and stays green. Start again if necessary.
3 Your module has now its original settings.
TIP

N L
USER GUIDEEN APPROVALS AND CERTIFICATIONS
INSTALLATION
*
Or
Or
Reference: SIN-2-2-01
Power supply: 230V AC ~ 50Hz
Switching capabilities: 230V AC - 2 x 5A
Consumption: <1W
Maximum output power: 2 x 1150W (Resistive load)
List of compatible loads available on nodon.fr/loads
Radio frequency range: 868.0 to 868.6 Mhz
RF power max: +3dBm
Range: up to 30m indoor
Operational temperature: -10°C to 40°C
Protection rating: IP 30
Pairing: up to 22 controllers
EEP (EnOcean Prole): D2-01-12
Dimensions: 40 mm (l) x 44 mm (L) x 16.9 mm (h)
Weight: 34 g
Warranty: 2 years
ON/OFF LIGHTING
RELAY SWITCH
CONTACT AFTER SALES SERVICE
USE CAUTIONS
• Never use the device if it is not correctly installed and
placed inside a connecting box in conformity with the
current norms.
• Keep the product far away from liquids.
nodon.fr/en/“support” section
NodOn SAS
121 rue des Hêtres
45590 St CYR EN VAL
(FRANCE)
This product is conform to EnOcean radio protocol.
This product must be used indoor only.
The presence of this symbol on a product indicates
that this one is conform to the European directive
2012/19/UE. Find out more about the provisions in
force in your region regarding the separate collection
of electrical and electronical devices. Respect the local rules and
do not throw out the product with common domestic wastes.
The correct rejection of ancient products allows to preserve the
environment and health.
Hereby, NodOn SAS declares that this radio equipment
is conform to the RED directive 2014/53/UE. The
integral text of the EU declaration of conformity
is available at the following online address: nodon.fr/en/
”support” section.
DANGER OF ELECTROCUTION
BEFORE ANY INSTALLATION MAKE SURE
THE POWER SUPPLY IS DISCONNECTED
TO AVOID ANY RISK OF ELECTROCUTION.
Directly cut the power supply from the breaker box to avoid
any risk of electrocution. This relay switch is designed to
be used power up, a wrong installation can create a re or
an electric shock. If you are not condent about electrical
installation, please ask a professional.
The relay switch must be installed and connected carefully
following the instructions of this user guide. We will not be
responsible for any loss or damage resulting from a non-
respect of the instructions of this user guide. Cut the power
supply before any operation and don’t do any modication
if the LED is still ON.
Thanks to its small size, the ON/OFF Lighting
Relay Switch can be installed anywhere in the
wall or the ceiling (behind an existing wall
switch, in a false ceiling, etc…).
Add the ON/OFF Lighting Relay Switch to the
electric panel with NodOn DIN Rail Box*.
*Optional accessory
RELAY SWITCH INPUT/OUTPUT
Each terminal can accept a cable of 2.5mm² maximum, stripped
of 8mm.
NTerminal for the Neutral
LTerminal for the Line
Input terminal
for the wired switch 1*
Input terminal
for the wired switch 2*
Output 1 (controlled by )
Output 2 (controlled by )
*Wired switch optional (see the installation diagrams section)
INSTALLATION DIAGRAM FOR ONE
OR TWO LIGHTS
Wiring with one or two ways
*Wired switch optional (see the installation diagrams section)
After turning the power supply ON, do a single push on the wired
wall switch. The relay switch has an auto-detection system to
automatically detect the type of wired wall switch (rocker or
push-button) wired at the input.
Note: The same configuration is applied for both inputs
( and ). It is not possible to combine a rocker switch
with a push-button. To perform a new auto-detection,
the ON/OFF Lighting Relay Switch must be manually reset
(see reset procedure).
AUTO-DETECTION OF SWITCH TYPE
PAIRING PROCEDURE
Note: if the LED blinks orange during the pairing procedure, it
means that more than 22 controllers are paired and that no more
controller can be paired. You must remove one controller to add
a new one.
Continue with steps 2 and 3a/3b to pair your controller.
USE OF YOUR SOFT BUTTON
The Soft Button will work as follows:
For more details on how to pair
a home automation gateway or
other compatible products, please
consult the “Support” section on
nodon.fr/en/
PAIRING
WITH A HOME AUTOMATION GATEWAY
UNPAIRING PROCEDURE
RESET PROCEDURE
DETAILED
USER GUIDE
Directly access the detailed user
guide on the Support section
on nodon.fr/en/technical-
support/
N L
N L
N L
N L N L
Types of press Action
Single press Reversal
Double press ON
Long press OFF
1 Cut the power supply
2 Dismantle the wired switch
controlling the light(s) you want
to connect.
3 Install the ON/OFF Lighting Relay
Switch according to diagram gure 1.
4 Reinstall the wired switch.
5 Turn the power supply back ON.
Figure 1
To add a remote or a wall switch or the Soft Button (EnOcean
compatible) you must enter the pairing mode, your light must be
switched OFF.
Relay switch must be power supplied.
Launch the pairing by doing 3 consecutive presses on
the relay switch button. The LED blinks red.
FOR CHANNEL 1 ( / )
Two modes:
1. From the module
You have now 30
seconds to pair your Soft
Button by doing 5 brief
consecutive presses on
the button.
You have 30 seconds to
pair your controller by briefly
pressing (in less than a second)
on the button of your choice,
this one will turn the light ON
for the channel 1, the opposite
button will turn it OFF.
Action the wired wall switch 3 times (in less than a
second). The lighting connected in blinks, meaning that
the channel 1 ( / ) is in “pairing/unpairing mode”.
2. From the wired wall switch
The LED of the relay
switch will blink green twice,
conrming the pairing of the
two devices.
The light stops to blink,
conrming the pairing of the
two devices.
Launch the pairing by doing 3 consecutive presses on the
relay switch button. The LED blinks red. Wait 1 second and do
a new press on the relay switch button.
FOR THE CHANNEL 2 ( / )
Two modes
1. From the relay switch
Press the wall switch 3 times (in less than a second).
Wait 1 second and do a new press on the wall switch. The light
connected in blinks, meaning that the channel 2 ( / )
is in “Pairing/Unpairing” mode.
2. From the wired wall switch
Do the same procedure as pairing (see “pairing procedure”) and
takes care of pressing the button chosen to control your gate/
garage door/electric latch or your electrical outlet.
Relay switch must be power supplied.
1 Press more than 5 seconds on your module’s button.
The LED blinks orange.
2 Press once again the button (short press) to conrm the
reset. If the reset is correct, the LED blinks alternatively in red
and green and stays green. Start again if necessary.
3 Your module has now its original settings.
TIP
N L
USER GUIDEEN APPROVALS AND CERTIFICATIONS
INSTALLATION
*
Or
Or
Reference: SIN-2-2-01
Power supply: 230V AC ~ 50Hz
Switching capabilities: 230V AC - 2 x 5A
Consumption: <1W
Maximum output power: 2 x 1150W (Resistive load)
List of compatible loads available on nodon.fr/loads
Radio frequency range: 868.0 to 868.6 Mhz
RF power max: +3dBm
Range: up to 30m indoor
Operational temperature: -10°C to 40°C
Protection rating: IP 30
Pairing: up to 22 controllers
EEP (EnOcean Prole): D2-01-12
Dimensions: 40 mm (l) x 44 mm (L) x 16.9 mm (h)
Weight: 34 g
Warranty: 2 years
ON/OFF LIGHTING
RELAY SWITCH
CONTACT AFTER SALES SERVICE
USE CAUTIONS
• Never use the device if it is not correctly installed and
placed inside a connecting box in conformity with the
current norms.
• Keep the product far away from liquids.
nodon.fr/en/“support” section
NodOn SAS
121 rue des Hêtres
45590 St CYR EN VAL
(FRANCE)
This product is conform to EnOcean radio protocol.
This product must be used indoor only.
The presence of this symbol on a product indicates
that this one is conform to the European directive
2012/19/UE. Find out more about the provisions in
force in your region regarding the separate collection
of electrical and electronical devices. Respect the local rules and
do not throw out the product with common domestic wastes.
The correct rejection of ancient products allows to preserve the
environment and health.
Hereby, NodOn SAS declares that this radio equipment
is conform to the RED directive 2014/53/UE. The
integral text of the EU declaration of conformity
is available at the following online address: nodon.fr/en/
”support” section.
DANGER OF ELECTROCUTION
BEFORE ANY INSTALLATION MAKE SURE
THE POWER SUPPLY IS DISCONNECTED
TO AVOID ANY RISK OF ELECTROCUTION.
Directly cut the power supply from the breaker box to avoid
any risk of electrocution. This relay switch is designed to
be used power up, a wrong installation can create a re or
an electric shock. If you are not condent about electrical
installation, please ask a professional.
The relay switch must be installed and connected carefully
following the instructions of this user guide. We will not be
responsible for any loss or damage resulting from a non-
respect of the instructions of this user guide. Cut the power
supply before any operation and don’t do any modication
if the LED is still ON.
Thanks to its small size, the ON/OFF Lighting
Relay Switch can be installed anywhere in the
wall or the ceiling (behind an existing wall
switch, in a false ceiling, etc…).
Add the ON/OFF Lighting Relay Switch to the
electric panel with NodOn DIN Rail Box*.
*Optional accessory
RELAY SWITCH INPUT/OUTPUT
Each terminal can accept a cable of 2.5mm² maximum, stripped
of 8mm.
NTerminal for the Neutral
LTerminal for the Line
Input terminal
for the wired switch 1*
Input terminal
for the wired switch 2*
Output 1 (controlled by )
Output 2 (controlled by )
*Wired switch optional (see the installation diagrams section)
INSTALLATION DIAGRAM FOR ONE
OR TWO LIGHTS
Wiring with one or two ways
*Wired switch optional (see the installation diagrams section)
After turning the power supply ON, do a single push on the wired
wall switch. The relay switch has an auto-detection system to
automatically detect the type of wired wall switch (rocker or
push-button) wired at the input.
Note: The same configuration is applied for both inputs
( and ). It is not possible to combine a rocker switch
with a push-button. To perform a new auto-detection,
the ON/OFF Lighting Relay Switch must be manually reset
(see reset procedure).
AUTO-DETECTION OF SWITCH TYPE
PAIRING PROCEDURE
Note: if the LED blinks orange during the pairing procedure, it
means that more than 22 controllers are paired and that no more
controller can be paired. You must remove one controller to add
a new one.
Continue with steps 2 and 3a/3b to pair your controller.
USE OF YOUR SOFT BUTTON
The Soft Button will work as follows:
For more details on how to pair
a home automation gateway or
other compatible products, please
consult the “Support” section on
nodon.fr/en/
PAIRING
WITH A HOME AUTOMATION GATEWAY
UNPAIRING PROCEDURE
RESET PROCEDURE
DETAILED
USER GUIDE
Directly access the detailed user
guide on the Support section
on nodon.fr/en/technical-
support/
N L
N L
N L
N L N L
Types of press Action
Single press Reversal
Double press ON
Long press OFF
1 Cut the power supply
2 Dismantle the wired switch
controlling the light(s) you want
to connect.
3 Install the ON/OFF Lighting Relay
Switch according to diagram gure 1.
4 Reinstall the wired switch.
5 Turn the power supply back ON.
Figure 1
To add a remote or a wall switch or the Soft Button (EnOcean
compatible) you must enter the pairing mode, your light must be
switched OFF.
Relay switch must be power supplied.
Launch the pairing by doing 3 consecutive presses on
the relay switch button. The LED blinks red.
FOR CHANNEL 1 ( / )
Two modes:
1. From the module
You have now 30
seconds to pair your Soft
Button by doing 5 brief
consecutive presses on
the button.
You have 30 seconds to
pair your controller by briefly
pressing (in less than a second)
on the button of your choice,
this one will turn the light ON
for the channel 1, the opposite
button will turn it OFF.
Action the wired wall switch 3 times (in less than a
second). The lighting connected in blinks, meaning that
the channel 1 ( / ) is in “pairing/unpairing mode”.
2. From the wired wall switch
The LED of the relay
switch will blink green twice,
conrming the pairing of the
two devices.
The light stops to blink,
conrming the pairing of the
two devices.
Launch the pairing by doing 3 consecutive presses on the
relay switch button. The LED blinks red. Wait 1 second and do
a new press on the relay switch button.
FOR THE CHANNEL 2 ( / )
Two modes
1. From the relay switch
Press the wall switch 3 times (in less than a second).
Wait 1 second and do a new press on the wall switch. The light
connected in blinks, meaning that the channel 2 ( / )
is in “Pairing/Unpairing” mode.
2. From the wired wall switch
Do the same procedure as pairing (see “pairing procedure”) and
takes care of pressing the button chosen to control your gate/
garage door/electric latch or your electrical outlet.
Relay switch must be power supplied.
1 Press more than 5 seconds on your module’s button.
The LED blinks orange.
2 Press once again the button (short press) to conrm the
reset. If the reset is correct, the LED blinks alternatively in red
and green and stays green. Start again if necessary.
3 Your module has now its original settings.
TIP

N L
USER GUIDEEN APPROVALS AND CERTIFICATIONS
INSTALLATION
*
Or
Or
Reference: SIN-2-2-01
Power supply: 230V AC ~ 50Hz
Switching capabilities: 230V AC - 2 x 5A
Consumption: <1W
Maximum output power: 2 x 1150W (Resistive load)
List of compatible loads available on nodon.fr/loads
Radio frequency range: 868.0 to 868.6 Mhz
RF power max: +3dBm
Range: up to 30m indoor
Operational temperature: -10°C to 40°C
Protection rating: IP 30
Pairing: up to 22 controllers
EEP (EnOcean Prole): D2-01-12
Dimensions: 40 mm (l) x 44 mm (L) x 16.9 mm (h)
Weight: 34 g
Warranty: 2 years
ON/OFF LIGHTING
RELAY SWITCH
CONTACT AFTER SALES SERVICE
USE CAUTIONS
• Never use the device if it is not correctly installed and
placed inside a connecting box in conformity with the
current norms.
• Keep the product far away from liquids.
nodon.fr/en/“support” section
NodOn SAS
121 rue des Hêtres
45590 St CYR EN VAL
(FRANCE)
This product is conform to EnOcean radio protocol.
This product must be used indoor only.
The presence of this symbol on a product indicates
that this one is conform to the European directive
2012/19/UE. Find out more about the provisions in
force in your region regarding the separate collection
of electrical and electronical devices. Respect the local rules and
do not throw out the product with common domestic wastes.
The correct rejection of ancient products allows to preserve the
environment and health.
Hereby, NodOn SAS declares that this radio equipment
is conform to the RED directive 2014/53/UE. The
integral text of the EU declaration of conformity
is available at the following online address: nodon.fr/en/
”support” section.
DANGER OF ELECTROCUTION
BEFORE ANY INSTALLATION MAKE SURE
THE POWER SUPPLY IS DISCONNECTED
TO AVOID ANY RISK OF ELECTROCUTION.
Directly cut the power supply from the breaker box to avoid
any risk of electrocution. This relay switch is designed to
be used power up, a wrong installation can create a re or
an electric shock. If you are not condent about electrical
installation, please ask a professional.
The relay switch must be installed and connected carefully
following the instructions of this user guide. We will not be
responsible for any loss or damage resulting from a non-
respect of the instructions of this user guide. Cut the power
supply before any operation and don’t do any modication
if the LED is still ON.
Thanks to its small size, the ON/OFF Lighting
Relay Switch can be installed anywhere in the
wall or the ceiling (behind an existing wall
switch, in a false ceiling, etc…).
Add the ON/OFF Lighting Relay Switch to the
electric panel with NodOn DIN Rail Box*.
*Optional accessory
RELAY SWITCH INPUT/OUTPUT
Each terminal can accept a cable of 2.5mm² maximum, stripped
of 8mm.
NTerminal for the Neutral
LTerminal for the Line
Input terminal
for the wired switch 1*
Input terminal
for the wired switch 2*
Output 1 (controlled by )
Output 2 (controlled by )
*Wired switch optional (see the installation diagrams section)
INSTALLATION DIAGRAM FOR ONE
OR TWO LIGHTS
Wiring with one or two ways
*Wired switch optional (see the installation diagrams section)
After turning the power supply ON, do a single push on the wired
wall switch. The relay switch has an auto-detection system to
automatically detect the type of wired wall switch (rocker or
push-button) wired at the input.
Note: The same configuration is applied for both inputs
( and ). It is not possible to combine a rocker switch
with a push-button. To perform a new auto-detection,
the ON/OFF Lighting Relay Switch must be manually reset
(see reset procedure).
AUTO-DETECTION OF SWITCH TYPE
PAIRING PROCEDURE
Note: if the LED blinks orange during the pairing procedure, it
means that more than 22 controllers are paired and that no more
controller can be paired. You must remove one controller to add
a new one.
Continue with steps 2 and 3a/3b to pair your controller.
USE OF YOUR SOFT BUTTON
The Soft Button will work as follows:
For more details on how to pair
a home automation gateway or
other compatible products, please
consult the “Support” section on
nodon.fr/en/
PAIRING
WITH A HOME AUTOMATION GATEWAY
UNPAIRING PROCEDURE
RESET PROCEDURE
DETAILED
USER GUIDE
Directly access the detailed user
guide on the Support section
on nodon.fr/en/technical-
support/
N L
N L
N L
N L N L
Types of press Action
Single press Reversal
Double press ON
Long press OFF
1 Cut the power supply
2 Dismantle the wired switch
controlling the light(s) you want
to connect.
3 Install the ON/OFF Lighting Relay
Switch according to diagram gure 1.
4 Reinstall the wired switch.
5 Turn the power supply back ON.
Figure 1
To add a remote or a wall switch or the Soft Button (EnOcean
compatible) you must enter the pairing mode, your light must be
switched OFF.
Relay switch must be power supplied.
Launch the pairing by doing 3 consecutive presses on
the relay switch button. The LED blinks red.
FOR CHANNEL 1 ( / )
Two modes:
1. From the module
You have now 30
seconds to pair your Soft
Button by doing 5 brief
consecutive presses on
the button.
You have 30 seconds to
pair your controller by briefly
pressing (in less than a second)
on the button of your choice,
this one will turn the light ON
for the channel 1, the opposite
button will turn it OFF.
Action the wired wall switch 3 times (in less than a
second). The lighting connected in blinks, meaning that
the channel 1 ( / ) is in “pairing/unpairing mode”.
2. From the wired wall switch
The LED of the relay
switch will blink green twice,
conrming the pairing of the
two devices.
The light stops to blink,
conrming the pairing of the
two devices.
Launch the pairing by doing 3 consecutive presses on the
relay switch button. The LED blinks red. Wait 1 second and do
a new press on the relay switch button.
FOR THE CHANNEL 2 ( / )
Two modes
1. From the relay switch
Press the wall switch 3 times (in less than a second).
Wait 1 second and do a new press on the wall switch. The light
connected in blinks, meaning that the channel 2 ( / )
is in “Pairing/Unpairing” mode.
2. From the wired wall switch
Do the same procedure as pairing (see “pairing procedure”) and
takes care of pressing the button chosen to control your gate/
garage door/electric latch or your electrical outlet.
Relay switch must be power supplied.
1 Press more than 5 seconds on your module’s button.
The LED blinks orange.
2 Press once again the button (short press) to conrm the
reset. If the reset is correct, the LED blinks alternatively in red
and green and stays green. Start again if necessary.
3 Your module has now its original settings.
TIP
N L
USER GUIDEEN APPROVALS AND CERTIFICATIONS
INSTALLATION
*
Or
Or
Reference: SIN-2-2-01
Power supply: 230V AC ~ 50Hz
Switching capabilities: 230V AC - 2 x 5A
Consumption: <1W
Maximum output power: 2 x 1150W (Resistive load)
List of compatible loads available on nodon.fr/loads
Radio frequency range: 868.0 to 868.6 Mhz
RF power max: +3dBm
Range: up to 30m indoor
Operational temperature: -10°C to 40°C
Protection rating: IP 30
Pairing: up to 22 controllers
EEP (EnOcean Prole): D2-01-12
Dimensions: 40 mm (l) x 44 mm (L) x 16.9 mm (h)
Weight: 34 g
Warranty: 2 years
ON/OFF LIGHTING
RELAY SWITCH
CONTACT AFTER SALES SERVICE
USE CAUTIONS
• Never use the device if it is not correctly installed and
placed inside a connecting box in conformity with the
current norms.
• Keep the product far away from liquids.
nodon.fr/en/“support” section
NodOn SAS
121 rue des Hêtres
45590 St CYR EN VAL
(FRANCE)
This product is conform to EnOcean radio protocol.
This product must be used indoor only.
The presence of this symbol on a product indicates
that this one is conform to the European directive
2012/19/UE. Find out more about the provisions in
force in your region regarding the separate collection
of electrical and electronical devices. Respect the local rules and
do not throw out the product with common domestic wastes.
The correct rejection of ancient products allows to preserve the
environment and health.
Hereby, NodOn SAS declares that this radio equipment
is conform to the RED directive 2014/53/UE. The
integral text of the EU declaration of conformity
is available at the following online address: nodon.fr/en/
”support” section.
DANGER OF ELECTROCUTION
BEFORE ANY INSTALLATION MAKE SURE
THE POWER SUPPLY IS DISCONNECTED
TO AVOID ANY RISK OF ELECTROCUTION.
Directly cut the power supply from the breaker box to avoid
any risk of electrocution. This relay switch is designed to
be used power up, a wrong installation can create a re or
an electric shock. If you are not condent about electrical
installation, please ask a professional.
The relay switch must be installed and connected carefully
following the instructions of this user guide. We will not be
responsible for any loss or damage resulting from a non-
respect of the instructions of this user guide. Cut the power
supply before any operation and don’t do any modication
if the LED is still ON.
Thanks to its small size, the ON/OFF Lighting
Relay Switch can be installed anywhere in the
wall or the ceiling (behind an existing wall
switch, in a false ceiling, etc…).
Add the ON/OFF Lighting Relay Switch to the
electric panel with NodOn DIN Rail Box*.
*Optional accessory
RELAY SWITCH INPUT/OUTPUT
Each terminal can accept a cable of 2.5mm² maximum, stripped
of 8mm.
NTerminal for the Neutral
LTerminal for the Line
Input terminal
for the wired switch 1*
Input terminal
for the wired switch 2*
Output 1 (controlled by )
Output 2 (controlled by )
*Wired switch optional (see the installation diagrams section)
INSTALLATION DIAGRAM FOR ONE
OR TWO LIGHTS
Wiring with one or two ways
*Wired switch optional (see the installation diagrams section)
After turning the power supply ON, do a single push on the wired
wall switch. The relay switch has an auto-detection system to
automatically detect the type of wired wall switch (rocker or
push-button) wired at the input.
Note: The same configuration is applied for both inputs
( and ). It is not possible to combine a rocker switch
with a push-button. To perform a new auto-detection,
the ON/OFF Lighting Relay Switch must be manually reset
(see reset procedure).
AUTO-DETECTION OF SWITCH TYPE
PAIRING PROCEDURE
Note: if the LED blinks orange during the pairing procedure, it
means that more than 22 controllers are paired and that no more
controller can be paired. You must remove one controller to add
a new one.
Continue with steps 2 and 3a/3b to pair your controller.
USE OF YOUR SOFT BUTTON
The Soft Button will work as follows:
For more details on how to pair
a home automation gateway or
other compatible products, please
consult the “Support” section on
nodon.fr/en/
PAIRING
WITH A HOME AUTOMATION GATEWAY
UNPAIRING PROCEDURE
RESET PROCEDURE
DETAILED
USER GUIDE
Directly access the detailed user
guide on the Support section
on nodon.fr/en/technical-
support/
N L
N L
N L
N L N L
Types of press Action
Single press Reversal
Double press ON
Long press OFF
1 Cut the power supply
2 Dismantle the wired switch
controlling the light(s) you want
to connect.
3 Install the ON/OFF Lighting Relay
Switch according to diagram gure 1.
4 Reinstall the wired switch.
5 Turn the power supply back ON.
Figure 1
To add a remote or a wall switch or the Soft Button (EnOcean
compatible) you must enter the pairing mode, your light must be
switched OFF.
Relay switch must be power supplied.
Launch the pairing by doing 3 consecutive presses on
the relay switch button. The LED blinks red.
FOR CHANNEL 1 ( / )
Two modes:
1. From the module
You have now 30
seconds to pair your Soft
Button by doing 5 brief
consecutive presses on
the button.
You have 30 seconds to
pair your controller by briefly
pressing (in less than a second)
on the button of your choice,
this one will turn the light ON
for the channel 1, the opposite
button will turn it OFF.
Action the wired wall switch 3 times (in less than a
second). The lighting connected in blinks, meaning that
the channel 1 ( / ) is in “pairing/unpairing mode”.
2. From the wired wall switch
The LED of the relay
switch will blink green twice,
conrming the pairing of the
two devices.
The light stops to blink,
conrming the pairing of the
two devices.
Launch the pairing by doing 3 consecutive presses on the
relay switch button. The LED blinks red. Wait 1 second and do
a new press on the relay switch button.
FOR THE CHANNEL 2 ( / )
Two modes
1. From the relay switch
Press the wall switch 3 times (in less than a second).
Wait 1 second and do a new press on the wall switch. The light
connected in blinks, meaning that the channel 2 ( / )
is in “Pairing/Unpairing” mode.
2. From the wired wall switch
Do the same procedure as pairing (see “pairing procedure”) and
takes care of pressing the button chosen to control your gate/
garage door/electric latch or your electrical outlet.
Relay switch must be power supplied.
1 Press more than 5 seconds on your module’s button.
The LED blinks orange.
2 Press once again the button (short press) to conrm the
reset. If the reset is correct, the LED blinks alternatively in red
and green and stays green. Start again if necessary.
3 Your module has now its original settings.
TIP

N L
USER GUIDEEN APPROVALS AND CERTIFICATIONS
INSTALLATION
*
Or
Or
Reference: SIN-2-2-01
Power supply: 230V AC ~ 50Hz
Switching capabilities: 230V AC - 2 x 5A
Consumption: <1W
Maximum output power: 2 x 1150W (Resistive load)
List of compatible loads available on nodon.fr/loads
Radio frequency range: 868.0 to 868.6 Mhz
RF power max: +3dBm
Range: up to 30m indoor
Operational temperature: -10°C to 40°C
Protection rating: IP 30
Pairing: up to 22 controllers
EEP (EnOcean Prole): D2-01-12
Dimensions: 40 mm (l) x 44 mm (L) x 16.9 mm (h)
Weight: 34 g
Warranty: 2 years
ON/OFF LIGHTING
RELAY SWITCH
CONTACT AFTER SALES SERVICE
USE CAUTIONS
• Never use the device if it is not correctly installed and
placed inside a connecting box in conformity with the
current norms.
• Keep the product far away from liquids.
nodon.fr/en/“support” section
NodOn SAS
121 rue des Hêtres
45590 St CYR EN VAL
(FRANCE)
This product is conform to EnOcean radio protocol.
This product must be used indoor only.
The presence of this symbol on a product indicates
that this one is conform to the European directive
2012/19/UE. Find out more about the provisions in
force in your region regarding the separate collection
of electrical and electronical devices. Respect the local rules and
do not throw out the product with common domestic wastes.
The correct rejection of ancient products allows to preserve the
environment and health.
Hereby, NodOn SAS declares that this radio equipment
is conform to the RED directive 2014/53/UE. The
integral text of the EU declaration of conformity
is available at the following online address: nodon.fr/en/
”support” section.
DANGER OF ELECTROCUTION
BEFORE ANY INSTALLATION MAKE SURE
THE POWER SUPPLY IS DISCONNECTED
TO AVOID ANY RISK OF ELECTROCUTION.
Directly cut the power supply from the breaker box to avoid
any risk of electrocution. This relay switch is designed to
be used power up, a wrong installation can create a re or
an electric shock. If you are not condent about electrical
installation, please ask a professional.
The relay switch must be installed and connected carefully
following the instructions of this user guide. We will not be
responsible for any loss or damage resulting from a non-
respect of the instructions of this user guide. Cut the power
supply before any operation and don’t do any modication
if the LED is still ON.
Thanks to its small size, the ON/OFF Lighting
Relay Switch can be installed anywhere in the
wall or the ceiling (behind an existing wall
switch, in a false ceiling, etc…).
Add the ON/OFF Lighting Relay Switch to the
electric panel with NodOn DIN Rail Box*.
*Optional accessory
RELAY SWITCH INPUT/OUTPUT
Each terminal can accept a cable of 2.5mm² maximum, stripped
of 8mm.
NTerminal for the Neutral
LTerminal for the Line
Input terminal
for the wired switch 1*
Input terminal
for the wired switch 2*
Output 1 (controlled by )
Output 2 (controlled by )
*Wired switch optional (see the installation diagrams section)
INSTALLATION DIAGRAM FOR ONE
OR TWO LIGHTS
Wiring with one or two ways
*Wired switch optional (see the installation diagrams section)
After turning the power supply ON, do a single push on the wired
wall switch. The relay switch has an auto-detection system to
automatically detect the type of wired wall switch (rocker or
push-button) wired at the input.
Note: The same configuration is applied for both inputs
( and ). It is not possible to combine a rocker switch
with a push-button. To perform a new auto-detection,
the ON/OFF Lighting Relay Switch must be manually reset
(see reset procedure).
AUTO-DETECTION OF SWITCH TYPE
PAIRING PROCEDURE
Note: if the LED blinks orange during the pairing procedure, it
means that more than 22 controllers are paired and that no more
controller can be paired. You must remove one controller to add
a new one.
Continue with steps 2 and 3a/3b to pair your controller.
USE OF YOUR SOFT BUTTON
The Soft Button will work as follows:
For more details on how to pair
a home automation gateway or
other compatible products, please
consult the “Support” section on
nodon.fr/en/
PAIRING
WITH A HOME AUTOMATION GATEWAY
UNPAIRING PROCEDURE
RESET PROCEDURE
DETAILED
USER GUIDE
Directly access the detailed user
guide on the Support section
on nodon.fr/en/technical-
support/
N L
N L
N L
N L N L
Types of press Action
Single press Reversal
Double press ON
Long press OFF
1 Cut the power supply
2 Dismantle the wired switch
controlling the light(s) you want
to connect.
3 Install the ON/OFF Lighting Relay
Switch according to diagram gure 1.
4 Reinstall the wired switch.
5 Turn the power supply back ON.
Figure 1
To add a remote or a wall switch or the Soft Button (EnOcean
compatible) you must enter the pairing mode, your light must be
switched OFF.
Relay switch must be power supplied.
Launch the pairing by doing 3 consecutive presses on
the relay switch button. The LED blinks red.
FOR CHANNEL 1 ( / )
Two modes:
1. From the module
You have now 30
seconds to pair your Soft
Button by doing 5 brief
consecutive presses on
the button.
You have 30 seconds to
pair your controller by briefly
pressing (in less than a second)
on the button of your choice,
this one will turn the light ON
for the channel 1, the opposite
button will turn it OFF.
Action the wired wall switch 3 times (in less than a
second). The lighting connected in blinks, meaning that
the channel 1 ( / ) is in “pairing/unpairing mode”.
2. From the wired wall switch
The LED of the relay
switch will blink green twice,
conrming the pairing of the
two devices.
The light stops to blink,
conrming the pairing of the
two devices.
Launch the pairing by doing 3 consecutive presses on the
relay switch button. The LED blinks red. Wait 1 second and do
a new press on the relay switch button.
FOR THE CHANNEL 2 ( / )
Two modes
1. From the relay switch
Press the wall switch 3 times (in less than a second).
Wait 1 second and do a new press on the wall switch. The light
connected in blinks, meaning that the channel 2 ( / )
is in “Pairing/Unpairing” mode.
2. From the wired wall switch
Do the same procedure as pairing (see “pairing procedure”) and
takes care of pressing the button chosen to control your gate/
garage door/electric latch or your electrical outlet.
Relay switch must be power supplied.
1 Press more than 5 seconds on your module’s button.
The LED blinks orange.
2 Press once again the button (short press) to conrm the
reset. If the reset is correct, the LED blinks alternatively in red
and green and stays green. Start again if necessary.
3 Your module has now its original settings.
TIP
N L
USER GUIDEEN APPROVALS AND CERTIFICATIONS
INSTALLATION
*
Or
Or
Reference: SIN-2-2-01
Power supply: 230V AC ~ 50Hz
Switching capabilities: 230V AC - 2 x 5A
Consumption: <1W
Maximum output power: 2 x 1150W (Resistive load)
List of compatible loads available on nodon.fr/loads
Radio frequency range: 868.0 to 868.6 Mhz
RF power max: +3dBm
Range: up to 30m indoor
Operational temperature: -10°C to 40°C
Protection rating: IP 30
Pairing: up to 22 controllers
EEP (EnOcean Prole): D2-01-12
Dimensions: 40 mm (l) x 44 mm (L) x 16.9 mm (h)
Weight: 34 g
Warranty: 2 years
ON/OFF LIGHTING
RELAY SWITCH
CONTACT AFTER SALES SERVICE
USE CAUTIONS
• Never use the device if it is not correctly installed and
placed inside a connecting box in conformity with the
current norms.
• Keep the product far away from liquids.
nodon.fr/en/“support” section
NodOn SAS
121 rue des Hêtres
45590 St CYR EN VAL
(FRANCE)
This product is conform to EnOcean radio protocol.
This product must be used indoor only.
The presence of this symbol on a product indicates
that this one is conform to the European directive
2012/19/UE. Find out more about the provisions in
force in your region regarding the separate collection
of electrical and electronical devices. Respect the local rules and
do not throw out the product with common domestic wastes.
The correct rejection of ancient products allows to preserve the
environment and health.
Hereby, NodOn SAS declares that this radio equipment
is conform to the RED directive 2014/53/UE. The
integral text of the EU declaration of conformity
is available at the following online address: nodon.fr/en/
”support” section.
DANGER OF ELECTROCUTION
BEFORE ANY INSTALLATION MAKE SURE
THE POWER SUPPLY IS DISCONNECTED
TO AVOID ANY RISK OF ELECTROCUTION.
Directly cut the power supply from the breaker box to avoid
any risk of electrocution. This relay switch is designed to
be used power up, a wrong installation can create a re or
an electric shock. If you are not condent about electrical
installation, please ask a professional.
The relay switch must be installed and connected carefully
following the instructions of this user guide. We will not be
responsible for any loss or damage resulting from a non-
respect of the instructions of this user guide. Cut the power
supply before any operation and don’t do any modication
if the LED is still ON.
Thanks to its small size, the ON/OFF Lighting
Relay Switch can be installed anywhere in the
wall or the ceiling (behind an existing wall
switch, in a false ceiling, etc…).
Add the ON/OFF Lighting Relay Switch to the
electric panel with NodOn DIN Rail Box*.
*Optional accessory
RELAY SWITCH INPUT/OUTPUT
Each terminal can accept a cable of 2.5mm² maximum, stripped
of 8mm.
NTerminal for the Neutral
LTerminal for the Line
Input terminal
for the wired switch 1*
Input terminal
for the wired switch 2*
Output 1 (controlled by )
Output 2 (controlled by )
*Wired switch optional (see the installation diagrams section)
INSTALLATION DIAGRAM FOR ONE
OR TWO LIGHTS
Wiring with one or two ways
*Wired switch optional (see the installation diagrams section)
After turning the power supply ON, do a single push on the wired
wall switch. The relay switch has an auto-detection system to
automatically detect the type of wired wall switch (rocker or
push-button) wired at the input.
Note: The same configuration is applied for both inputs
( and ). It is not possible to combine a rocker switch
with a push-button. To perform a new auto-detection,
the ON/OFF Lighting Relay Switch must be manually reset
(see reset procedure).
AUTO-DETECTION OF SWITCH TYPE
PAIRING PROCEDURE
Note: if the LED blinks orange during the pairing procedure, it
means that more than 22 controllers are paired and that no more
controller can be paired. You must remove one controller to add
a new one.
Continue with steps 2 and 3a/3b to pair your controller.
USE OF YOUR SOFT BUTTON
The Soft Button will work as follows:
For more details on how to pair
a home automation gateway or
other compatible products, please
consult the “Support” section on
nodon.fr/en/
PAIRING
WITH A HOME AUTOMATION GATEWAY
UNPAIRING PROCEDURE
RESET PROCEDURE
DETAILED
USER GUIDE
Directly access the detailed user
guide on the Support section
on nodon.fr/en/technical-
support/
N L
N L
N L
N L N L
Types of press Action
Single press Reversal
Double press ON
Long press OFF
1 Cut the power supply
2 Dismantle the wired switch
controlling the light(s) you want
to connect.
3 Install the ON/OFF Lighting Relay
Switch according to diagram gure 1.
4 Reinstall the wired switch.
5 Turn the power supply back ON.
Figure 1
To add a remote or a wall switch or the Soft Button (EnOcean
compatible) you must enter the pairing mode, your light must be
switched OFF.
Relay switch must be power supplied.
Launch the pairing by doing 3 consecutive presses on
the relay switch button. The LED blinks red.
FOR CHANNEL 1 ( / )
Two modes:
1. From the module
You have now 30
seconds to pair your Soft
Button by doing 5 brief
consecutive presses on
the button.
You have 30 seconds to
pair your controller by briefly
pressing (in less than a second)
on the button of your choice,
this one will turn the light ON
for the channel 1, the opposite
button will turn it OFF.
Action the wired wall switch 3 times (in less than a
second). The lighting connected in blinks, meaning that
the channel 1 ( / ) is in “pairing/unpairing mode”.
2. From the wired wall switch
The LED of the relay
switch will blink green twice,
conrming the pairing of the
two devices.
The light stops to blink,
conrming the pairing of the
two devices.
Launch the pairing by doing 3 consecutive presses on the
relay switch button. The LED blinks red. Wait 1 second and do
a new press on the relay switch button.
FOR THE CHANNEL 2 ( / )
Two modes
1. From the relay switch
Press the wall switch 3 times (in less than a second).
Wait 1 second and do a new press on the wall switch. The light
connected in blinks, meaning that the channel 2 ( / )
is in “Pairing/Unpairing” mode.
2. From the wired wall switch
Do the same procedure as pairing (see “pairing procedure”) and
takes care of pressing the button chosen to control your gate/
garage door/electric latch or your electrical outlet.
Relay switch must be power supplied.
1 Press more than 5 seconds on your module’s button.
The LED blinks orange.
2 Press once again the button (short press) to conrm the
reset. If the reset is correct, the LED blinks alternatively in red
and green and stays green. Start again if necessary.
3 Your module has now its original settings.
TIP

N L
USER GUIDEEN APPROVALS AND CERTIFICATIONS
INSTALLATION
*
Or
Or
Reference: SIN-2-2-01
Power supply: 230V AC ~ 50Hz
Switching capabilities: 230V AC - 2 x 5A
Consumption: <1W
Maximum output power: 2 x 1150W (Resistive load)
List of compatible loads available on nodon.fr/loads
Radio frequency range: 868.0 to 868.6 Mhz
RF power max: +3dBm
Range: up to 30m indoor
Operational temperature: -10°C to 40°C
Protection rating: IP 30
Pairing: up to 22 controllers
EEP (EnOcean Prole): D2-01-12
Dimensions: 40 mm (l) x 44 mm (L) x 16.9 mm (h)
Weight: 34 g
Warranty: 2 years
ON/OFF LIGHTING
RELAY SWITCH
CONTACT AFTER SALES SERVICE
USE CAUTIONS
• Never use the device if it is not correctly installed and
placed inside a connecting box in conformity with the
current norms.
• Keep the product far away from liquids.
nodon.fr/en/“support” section
NodOn SAS
121 rue des Hêtres
45590 St CYR EN VAL
(FRANCE)
This product is conform to EnOcean radio protocol.
This product must be used indoor only.
The presence of this symbol on a product indicates
that this one is conform to the European directive
2012/19/UE. Find out more about the provisions in
force in your region regarding the separate collection
of electrical and electronical devices. Respect the local rules and
do not throw out the product with common domestic wastes.
The correct rejection of ancient products allows to preserve the
environment and health.
Hereby, NodOn SAS declares that this radio equipment
is conform to the RED directive 2014/53/UE. The
integral text of the EU declaration of conformity
is available at the following online address: nodon.fr/en/
”support” section.
DANGER OF ELECTROCUTION
BEFORE ANY INSTALLATION MAKE SURE
THE POWER SUPPLY IS DISCONNECTED
TO AVOID ANY RISK OF ELECTROCUTION.
Directly cut the power supply from the breaker box to avoid
any risk of electrocution. This relay switch is designed to
be used power up, a wrong installation can create a re or
an electric shock. If you are not condent about electrical
installation, please ask a professional.
The relay switch must be installed and connected carefully
following the instructions of this user guide. We will not be
responsible for any loss or damage resulting from a non-
respect of the instructions of this user guide. Cut the power
supply before any operation and don’t do any modication
if the LED is still ON.
Thanks to its small size, the ON/OFF Lighting
Relay Switch can be installed anywhere in the
wall or the ceiling (behind an existing wall
switch, in a false ceiling, etc…).
Add the ON/OFF Lighting Relay Switch to the
electric panel with NodOn DIN Rail Box*.
*Optional accessory
RELAY SWITCH INPUT/OUTPUT
Each terminal can accept a cable of 2.5mm² maximum, stripped
of 8mm.
NTerminal for the Neutral
LTerminal for the Line
Input terminal
for the wired switch 1*
Input terminal
for the wired switch 2*
Output 1 (controlled by )
Output 2 (controlled by )
*Wired switch optional (see the installation diagrams section)
INSTALLATION DIAGRAM FOR ONE
OR TWO LIGHTS
Wiring with one or two ways
*Wired switch optional (see the installation diagrams section)
After turning the power supply ON, do a single push on the wired
wall switch. The relay switch has an auto-detection system to
automatically detect the type of wired wall switch (rocker or
push-button) wired at the input.
Note: The same configuration is applied for both inputs
( and ). It is not possible to combine a rocker switch
with a push-button. To perform a new auto-detection,
the ON/OFF Lighting Relay Switch must be manually reset
(see reset procedure).
AUTO-DETECTION OF SWITCH TYPE
PAIRING PROCEDURE
Note: if the LED blinks orange during the pairing procedure, it
means that more than 22 controllers are paired and that no more
controller can be paired. You must remove one controller to add
a new one.
Continue with steps 2 and 3a/3b to pair your controller.
USE OF YOUR SOFT BUTTON
The Soft Button will work as follows:
For more details on how to pair
a home automation gateway or
other compatible products, please
consult the “Support” section on
nodon.fr/en/
PAIRING
WITH A HOME AUTOMATION GATEWAY
UNPAIRING PROCEDURE
RESET PROCEDURE
DETAILED
USER GUIDE
Directly access the detailed user
guide on the Support section
on nodon.fr/en/technical-
support/
N L
N L
N L
N L N L
Types of press Action
Single press Reversal
Double press ON
Long press OFF
1 Cut the power supply
2 Dismantle the wired switch
controlling the light(s) you want
to connect.
3 Install the ON/OFF Lighting Relay
Switch according to diagram gure 1.
4 Reinstall the wired switch.
5 Turn the power supply back ON.
Figure 1
To add a remote or a wall switch or the Soft Button (EnOcean
compatible) you must enter the pairing mode, your light must be
switched OFF.
Relay switch must be power supplied.
Launch the pairing by doing 3 consecutive presses on
the relay switch button. The LED blinks red.
FOR CHANNEL 1 ( / )
Two modes:
1. From the module
You have now 30
seconds to pair your Soft
Button by doing 5 brief
consecutive presses on
the button.
You have 30 seconds to
pair your controller by briefly
pressing (in less than a second)
on the button of your choice,
this one will turn the light ON
for the channel 1, the opposite
button will turn it OFF.
Action the wired wall switch 3 times (in less than a
second). The lighting connected in blinks, meaning that
the channel 1 ( / ) is in “pairing/unpairing mode”.
2. From the wired wall switch
The LED of the relay
switch will blink green twice,
conrming the pairing of the
two devices.
The light stops to blink,
conrming the pairing of the
two devices.
Launch the pairing by doing 3 consecutive presses on the
relay switch button. The LED blinks red. Wait 1 second and do
a new press on the relay switch button.
FOR THE CHANNEL 2 ( / )
Two modes
1. From the relay switch
Press the wall switch 3 times (in less than a second).
Wait 1 second and do a new press on the wall switch. The light
connected in blinks, meaning that the channel 2 ( / )
is in “Pairing/Unpairing” mode.
2. From the wired wall switch
Do the same procedure as pairing (see “pairing procedure”) and
takes care of pressing the button chosen to control your gate/
garage door/electric latch or your electrical outlet.
Relay switch must be power supplied.
1 Press more than 5 seconds on your module’s button.
The LED blinks orange.
2 Press once again the button (short press) to conrm the
reset. If the reset is correct, the LED blinks alternatively in red
and green and stays green. Start again if necessary.
3 Your module has now its original settings.
TIP
N L
USER GUIDEEN APPROVALS AND CERTIFICATIONS
INSTALLATION
*
Or
Or
Reference: SIN-2-2-01
Power supply: 230V AC ~ 50Hz
Switching capabilities: 230V AC - 2 x 5A
Consumption: <1W
Maximum output power: 2 x 1150W (Resistive load)
List of compatible loads available on nodon.fr/loads
Radio frequency range: 868.0 to 868.6 Mhz
RF power max: +3dBm
Range: up to 30m indoor
Operational temperature: -10°C to 40°C
Protection rating: IP 30
Pairing: up to 22 controllers
EEP (EnOcean Prole): D2-01-12
Dimensions: 40 mm (l) x 44 mm (L) x 16.9 mm (h)
Weight: 34 g
Warranty: 2 years
ON/OFF LIGHTING
RELAY SWITCH
CONTACT AFTER SALES SERVICE
USE CAUTIONS
• Never use the device if it is not correctly installed and
placed inside a connecting box in conformity with the
current norms.
• Keep the product far away from liquids.
nodon.fr/en/“support” section
NodOn SAS
121 rue des Hêtres
45590 St CYR EN VAL
(FRANCE)
This product is conform to EnOcean radio protocol.
This product must be used indoor only.
The presence of this symbol on a product indicates
that this one is conform to the European directive
2012/19/UE. Find out more about the provisions in
force in your region regarding the separate collection
of electrical and electronical devices. Respect the local rules and
do not throw out the product with common domestic wastes.
The correct rejection of ancient products allows to preserve the
environment and health.
Hereby, NodOn SAS declares that this radio equipment
is conform to the RED directive 2014/53/UE. The
integral text of the EU declaration of conformity
is available at the following online address: nodon.fr/en/
”support” section.
DANGER OF ELECTROCUTION
BEFORE ANY INSTALLATION MAKE SURE
THE POWER SUPPLY IS DISCONNECTED
TO AVOID ANY RISK OF ELECTROCUTION.
Directly cut the power supply from the breaker box to avoid
any risk of electrocution. This relay switch is designed to
be used power up, a wrong installation can create a re or
an electric shock. If you are not condent about electrical
installation, please ask a professional.
The relay switch must be installed and connected carefully
following the instructions of this user guide. We will not be
responsible for any loss or damage resulting from a non-
respect of the instructions of this user guide. Cut the power
supply before any operation and don’t do any modication
if the LED is still ON.
Thanks to its small size, the ON/OFF Lighting
Relay Switch can be installed anywhere in the
wall or the ceiling (behind an existing wall
switch, in a false ceiling, etc…).
Add the ON/OFF Lighting Relay Switch to the
electric panel with NodOn DIN Rail Box*.
*Optional accessory
RELAY SWITCH INPUT/OUTPUT
Each terminal can accept a cable of 2.5mm² maximum, stripped
of 8mm.
NTerminal for the Neutral
LTerminal for the Line
Input terminal
for the wired switch 1*
Input terminal
for the wired switch 2*
Output 1 (controlled by )
Output 2 (controlled by )
*Wired switch optional (see the installation diagrams section)
INSTALLATION DIAGRAM FOR ONE
OR TWO LIGHTS
Wiring with one or two ways
*Wired switch optional (see the installation diagrams section)
After turning the power supply ON, do a single push on the wired
wall switch. The relay switch has an auto-detection system to
automatically detect the type of wired wall switch (rocker or
push-button) wired at the input.
Note: The same configuration is applied for both inputs
( and ). It is not possible to combine a rocker switch
with a push-button. To perform a new auto-detection,
the ON/OFF Lighting Relay Switch must be manually reset
(see reset procedure).
AUTO-DETECTION OF SWITCH TYPE
PAIRING PROCEDURE
Note: if the LED blinks orange during the pairing procedure, it
means that more than 22 controllers are paired and that no more
controller can be paired. You must remove one controller to add
a new one.
Continue with steps 2 and 3a/3b to pair your controller.
USE OF YOUR SOFT BUTTON
The Soft Button will work as follows:
For more details on how to pair
a home automation gateway or
other compatible products, please
consult the “Support” section on
nodon.fr/en/
PAIRING
WITH A HOME AUTOMATION GATEWAY
UNPAIRING PROCEDURE
RESET PROCEDURE
DETAILED
USER GUIDE
Directly access the detailed user
guide on the Support section
on nodon.fr/en/technical-
support/
N L
N L
N L
N L N L
Types of press Action
Single press Reversal
Double press ON
Long press OFF
1 Cut the power supply
2 Dismantle the wired switch
controlling the light(s) you want
to connect.
3 Install the ON/OFF Lighting Relay
Switch according to diagram gure 1.
4 Reinstall the wired switch.
5 Turn the power supply back ON.
Figure 1
To add a remote or a wall switch or the Soft Button (EnOcean
compatible) you must enter the pairing mode, your light must be
switched OFF.
Relay switch must be power supplied.
Launch the pairing by doing 3 consecutive presses on
the relay switch button. The LED blinks red.
FOR CHANNEL 1 ( / )
Two modes:
1. From the module
You have now 30
seconds to pair your Soft
Button by doing 5 brief
consecutive presses on
the button.
You have 30 seconds to
pair your controller by briefly
pressing (in less than a second)
on the button of your choice,
this one will turn the light ON
for the channel 1, the opposite
button will turn it OFF.
Action the wired wall switch 3 times (in less than a
second). The lighting connected in blinks, meaning that
the channel 1 ( / ) is in “pairing/unpairing mode”.
2. From the wired wall switch
The LED of the relay
switch will blink green twice,
conrming the pairing of the
two devices.
The light stops to blink,
conrming the pairing of the
two devices.
Launch the pairing by doing 3 consecutive presses on the
relay switch button. The LED blinks red. Wait 1 second and do
a new press on the relay switch button.
FOR THE CHANNEL 2 ( / )
Two modes
1. From the relay switch
Press the wall switch 3 times (in less than a second).
Wait 1 second and do a new press on the wall switch. The light
connected in blinks, meaning that the channel 2 ( / )
is in “Pairing/Unpairing” mode.
2. From the wired wall switch
Do the same procedure as pairing (see “pairing procedure”) and
takes care of pressing the button chosen to control your gate/
garage door/electric latch or your electrical outlet.
Relay switch must be power supplied.
1 Press more than 5 seconds on your module’s button.
The LED blinks orange.
2 Press once again the button (short press) to conrm the
reset. If the reset is correct, the LED blinks alternatively in red
and green and stays green. Start again if necessary.
3 Your module has now its original settings.
TIP
N L
USER GUIDEEN APPROVALS AND CERTIFICATIONS
INSTALLATION
*
Or
Or
Reference: SIN-2-2-01
Power supply: 230V AC ~ 50Hz
Switching capabilities: 230V AC - 2 x 5A
Consumption: <1W
Maximum output power: 2 x 1150W (Resistive load)
List of compatible loads available on nodon.fr/loads
Radio frequency range: 868.0 to 868.6 Mhz
RF power max: +3dBm
Range: up to 30m indoor
Operational temperature: -10°C to 40°C
Protection rating: IP 30
Pairing: up to 22 controllers
EEP (EnOcean Prole): D2-01-12
Dimensions: 40 mm (l) x 44 mm (L) x 16.9 mm (h)
Weight: 34 g
Warranty: 2 years
ON/OFF LIGHTING
RELAY SWITCH
CONTACT AFTER SALES SERVICE
USE CAUTIONS
• Never use the device if it is not correctly installed and
placed inside a connecting box in conformity with the
current norms.
• Keep the product far away from liquids.
nodon.fr/en/“support” section
NodOn SAS
121 rue des Hêtres
45590 St CYR EN VAL
(FRANCE)
This product is conform to EnOcean radio protocol.
This product must be used indoor only.
The presence of this symbol on a product indicates
that this one is conform to the European directive
2012/19/UE. Find out more about the provisions in
force in your region regarding the separate collection
of electrical and electronical devices. Respect the local rules and
do not throw out the product with common domestic wastes.
The correct rejection of ancient products allows to preserve the
environment and health.
Hereby, NodOn SAS declares that this radio equipment
is conform to the RED directive 2014/53/UE. The
integral text of the EU declaration of conformity
is available at the following online address: nodon.fr/en/
”support” section.
DANGER OF ELECTROCUTION
BEFORE ANY INSTALLATION MAKE SURE
THE POWER SUPPLY IS DISCONNECTED
TO AVOID ANY RISK OF ELECTROCUTION.
Directly cut the power supply from the breaker box to avoid
any risk of electrocution. This relay switch is designed to
be used power up, a wrong installation can create a re or
an electric shock. If you are not condent about electrical
installation, please ask a professional.
The relay switch must be installed and connected carefully
following the instructions of this user guide. We will not be
responsible for any loss or damage resulting from a non-
respect of the instructions of this user guide. Cut the power
supply before any operation and don’t do any modication
if the LED is still ON.
Thanks to its small size, the ON/OFF Lighting
Relay Switch can be installed anywhere in the
wall or the ceiling (behind an existing wall
switch, in a false ceiling, etc…).
Add the ON/OFF Lighting Relay Switch to the
electric panel with NodOn DIN Rail Box*.
*Optional accessory
RELAY SWITCH INPUT/OUTPUT
Each terminal can accept a cable of 2.5mm² maximum, stripped
of 8mm.
NTerminal for the Neutral
LTerminal for the Line
Input terminal
for the wired switch 1*
Input terminal
for the wired switch 2*
Output 1 (controlled by )
Output 2 (controlled by )
*Wired switch optional (see the installation diagrams section)
INSTALLATION DIAGRAM FOR ONE
OR TWO LIGHTS
Wiring with one or two ways
*Wired switch optional (see the installation diagrams section)
After turning the power supply ON, do a single push on the wired
wall switch. The relay switch has an auto-detection system to
automatically detect the type of wired wall switch (rocker or
push-button) wired at the input.
Note: The same configuration is applied for both inputs
( and ). It is not possible to combine a rocker switch
with a push-button. To perform a new auto-detection,
the ON/OFF Lighting Relay Switch must be manually reset
(see reset procedure).
AUTO-DETECTION OF SWITCH TYPE
PAIRING PROCEDURE
Note: if the LED blinks orange during the pairing procedure, it
means that more than 22 controllers are paired and that no more
controller can be paired. You must remove one controller to add
a new one.
Continue with steps 2 and 3a/3b to pair your controller.
USE OF YOUR SOFT BUTTON
The Soft Button will work as follows:
For more details on how to pair
a home automation gateway or
other compatible products, please
consult the “Support” section on
nodon.fr/en/
PAIRING
WITH A HOME AUTOMATION GATEWAY
UNPAIRING PROCEDURE
RESET PROCEDURE
DETAILED
USER GUIDE
Directly access the detailed user
guide on the Support section
on nodon.fr/en/technical-
support/
N L
N L
N L
N L N L
Types of press Action
Single press Reversal
Double press ON
Long press OFF
1 Cut the power supply
2 Dismantle the wired switch
controlling the light(s) you want
to connect.
3 Install the ON/OFF Lighting Relay
Switch according to diagram gure 1.
4 Reinstall the wired switch.
5 Turn the power supply back ON.
Figure 1
To add a remote or a wall switch or the Soft Button (EnOcean
compatible) you must enter the pairing mode, your light must be
switched OFF.
Relay switch must be power supplied.
Launch the pairing by doing 3 consecutive presses on
the relay switch button. The LED blinks red.
FOR CHANNEL 1 ( / )
Two modes:
1. From the module
You have now 30
seconds to pair your Soft
Button by doing 5 brief
consecutive presses on
the button.
You have 30 seconds to
pair your controller by briefly
pressing (in less than a second)
on the button of your choice,
this one will turn the light ON
for the channel 1, the opposite
button will turn it OFF.
Action the wired wall switch 3 times (in less than a
second). The lighting connected in blinks, meaning that
the channel 1 ( / ) is in “pairing/unpairing mode”.
2. From the wired wall switch
The LED of the relay
switch will blink green twice,
conrming the pairing of the
two devices.
The light stops to blink,
conrming the pairing of the
two devices.
Launch the pairing by doing 3 consecutive presses on the
relay switch button. The LED blinks red. Wait 1 second and do
a new press on the relay switch button.
FOR THE CHANNEL 2 ( / )
Two modes
1. From the relay switch
Press the wall switch 3 times (in less than a second).
Wait 1 second and do a new press on the wall switch. The light
connected in blinks, meaning that the channel 2 ( / )
is in “Pairing/Unpairing” mode.
2. From the wired wall switch
Do the same procedure as pairing (see “pairing procedure”) and
takes care of pressing the button chosen to control your gate/
garage door/electric latch or your electrical outlet.
Relay switch must be power supplied.
1 Press more than 5 seconds on your module’s button.
The LED blinks orange.
2 Press once again the button (short press) to conrm the
reset. If the reset is correct, the LED blinks alternatively in red
and green and stays green. Start again if necessary.
3 Your module has now its original settings.
TIP
Table of contents
Other nodon Switch manuals