Nomura Engineering TS01 E 8sw User manual

Never use such a way that product malfunction or malfunction directly relates to human life.
Nomura Engineering Co.,Ltd. http://www.nomura-e.co.jp e-mail:info@nomura-e.co.jp
〒242-0023 Kanagawa prefecture Yamato shibuya 1 - chome 7-2
TEL: 046-244-0041 FAX: 046-244-3551
1/14
2017/12/04 Rev.2.0
TS01E 8sw communication system
TS01E 8sw
communication system
It is a communication system of 8 contacts
using TS01E (426MHzband 1 mW).
Nomura Engineering Co., Ltd.
Since 1997

Never use such a way that product malfunction or malfunction directly relates to human life.
Nomura Engineering Co.,Ltd. http://www.nomura-e.co.jp e-mail:info@nomura-e.co.jp
〒242-0023 Kanagawa prefecture Yamato shibuya 1 - chome 7-2
TEL: 046-244-0041 FAX: 046-244-3551
2/14
2017/12/04 Rev.2.0
TS01E 8sw communication system
table of contents
1.OVERVIEW ............................................................................................................................ 3
2.PRODUCT COMPOSITION ...................................................................................................... 4
3.FREQUENCY AND SETTING CHANNEL .................................................................................. 4
4.ABOUT THE TRANSMITTER (TS01ETX8SWBD).................................................................... 5
・TS01TX PIN ASSIGNMENT...................................................................................................... 5
・TRANSMITTER REFERENCE CIRCUIT DIAGRAM...................................................................... 7
5.ABOUT THE RECEIVER (TS01ERX8SW-*RXBD (S) -#) ...................................................... 8
・OUTPUT.................................................................................................................................. 8
・LED INDICATION................................................................................................................... 8
・CHANGE FREQUENCY CHANNEL............................................................................................ 8
・ID REGISTRATION.................................................................................................................. 9
・ID ERASE ............................................................................................................................... 9
・NOTES ................................................................................................................................... 9
・TS01RX -8SW PIN ASSIGNMENT......................................................................................... 10
・TS01RX-8SW RXBD(S)....................................................................................................... 11
・TS01RX-8SW RXBD(S) REFERENCE CIRCUIT DIAGRAM ..................................................... 12
6.PRECAUTIONS.................................................................................................................... 13
7.CHANGE HISTORY .............................................................................................................. 14

Never use such a way that product malfunction or malfunction directly relates to human life.
Nomura Engineering Co.,Ltd. http://www.nomura-e.co.jp e-mail:info@nomura-e.co.jp
〒242-0023 Kanagawa prefecture Yamato shibuya 1 - chome 7-2
TEL: 046-244-0041 FAX: 046-244-3551
3/14
2017/12/04 Rev.2.0
TS01E 8sw communication system
1.Overview
TS01E 8sw communication system is a remote control system of ON/OFF control of 8
switches by unidirectional communication, which is a combination of a transmitter
(TS01Etx8swBD) equipped with a specific low power radio 426 MHz band module TS 01
E and a receiver (TS 01 E rx 8 sw RXBD).
Register the ID of the transmitter in the receiver, pair it and use it. In addition, since
frequency channels can be selected from 7 channels, multiple systems can be used
within the same area.
The communication distance is about 100 m in the forecast. * There is also a long
distance type (LDM).
When the 8 switch input of the transmitter is grounded(GND), it enters the
transmission and the output of the corresponding receiver module goes to H level.
The receiver has a hold function that outputs H level for 2.5 seconds each time valid
data is received.
Therefore, when you instantly press the button of the transmitter, a pulsed output of 2.5
seconds is obtained from the receiver, and if you hold down the button of the transmitter,
the output of the receiver will remain on.
Since the transmitter has a transmission time limit of 5 seconds transmission and 2
seconds pause due to the Radio Law, transmission stops for 2 seconds, but this 2.5
second supplement enables continuous transmission operation.
The time it takes for the receiver to turn off after releasing the transmitter's button is
about 2.5 seconds.
The TS01E receiver application board is common to TS 02 E.

Never use such a way that product malfunction or malfunction directly relates to human life.
Nomura Engineering Co.,Ltd. http://www.nomura-e.co.jp e-mail:info@nomura-e.co.jp
〒242-0023 Kanagawa prefecture Yamato shibuya 1 - chome 7-2
TEL: 046-244-0041 FAX: 046-244-3551
4/14
2017/12/04 Rev.2.0
TS01E 8sw communication system
2. Product composition
Transmitter (module with board): TS01Etx8swBD
Input 8 contact ON / OFF input Active L power supply 2.1 to 7 V Flexible antenna
Receiver (module): TS 01 Elx 8 sw - *
Output 2 V CMOS level active H
*: Antenna selection F (flexible) ·S (whip)
P (Substrate) ·EXT (SMA Connector for External)
Receiver (application board): TS01E - 8swRXBD (S) - #
TS02E - 8sw receiving board is available.
#: Output selection P (when power supply output is on: + B output)
N (when open drain output is ON: ground)
The terminal block can be selected from the insertion type RXBD and the screw type
RXBDS.
There is also a type (RX - # - NWP) that entered the waterproof case.
3. Frequency and setting channel
Frequency (MHz) CH Designation
426.02500 0 channel
426.03750 1 channel
426.05000 2 channels
426.06250 3 channels
426.07500 4 channels
426.08750 5 channels
426.10000 6 channels
426.11250 7 channels
(426.12500 8 channels)
(426.13750 9 channels)

Never use such a way that product malfunction or malfunction directly relates to human life.
Nomura Engineering Co.,Ltd. http://www.nomura-e.co.jp e-mail:info@nomura-e.co.jp
〒242-0023 Kanagawa prefecture Yamato shibuya 1 - chome 7-2
TEL: 046-244-0041 FAX: 046-244-3551
5/14
2017/12/04 Rev.2.0
TS01E 8sw communication system
4. About the transmitter (TS01Etx8swBD)
Input 8 contacts active L
When the input of the transmitter is dropped to the ground(GND), the transmission
state is entered and the LED is lit.
The frequency channel can be changed from 0 to 6 channels with the rotary switch.
・TS01tx pin assignment
Terminal name function
1 Ready transmission data input enabled, active L (can be input with L)
2 TXdata transmission data input series.
3 Vccon power control, active L (power on
with L)
4 GND Ground
5 Vcc power supply input, 2.1 V to 7.0 V
6 GND Ground
7 NC
★Do not neither reverse supply of power supply nor apply absolute supply beyond 7.0 V.
If no logic is specified, 2 V CMOS logic (L: 0 to 0.3 V, H: 1.6 to 2 V) is assumed.

Never use such a way that product malfunction or malfunction directly relates to human life.
Nomura Engineering Co.,Ltd. http://www.nomura-e.co.jp e-mail:info@nomura-e.co.jp
〒242-0023 Kanagawa prefecture Yamato shibuya 1 - chome 7-2
TEL: 046-244-0041 FAX: 046-244-3551
6/14
2017/12/04 Rev.2.0
TS01E 8sw communication system
Please refer to the reference circuit diagram on the next page.

Never use such a way that product malfunction or malfunction directly relates to human life.
Nomura Engineering Co.,Ltd. http://www.nomura-e.co.jp e-mail:info@nomura-e.co.jp
〒242-0023 Kanagawa prefecture Yamato shibuya 1 - chome 7-2
TEL: 046-244-0041 FAX: 046-244-3551
7/14
2017/12/04 Rev.2.0
TS01E 8sw communication system
・Transmitter reference circuit diagram
htt 2015/02/23 Rev. 1.2!
!
送信機参考回路図
!
A
A
B
B
C
C
D
D
E
E
F
F
G
G
H
H
I
I
J
J
K
K
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
SIGNATURES DATE
APPROVED
DESIGNED
ISSUED
SIZE REM DWG NO
Nomura Engineering Co., Ltd.
Confidential Proprietary
A2
Note:
1) Unless otherwise indicated, all resistor values are in ohm,
all capacitor values are in microfarads, and all inductor
values are in microhenrys.
2) Components without value are not placed on the board.
REVISIONS
REV DESCRIPTION DATE APPROVED
11ts01tx8swJCI_r10.cct
ch
TS01tx 8SWBD
RC3
RC2
RC1
RC0
OSC2
OSC1
VSS
RA5
RA4
RA3
RA2
RA1
RA0
MCLR
RC4
RC5
RC6/TX
RC7/RX
VSS
VDD
RB0/INT
RB1
RB2
RB3
RB4
RB5
RB6/PGC
RB7/PGD
14
13
12
11
10
9
8
7
6
5
4
3
2
1
15
16
17
18
19
20
21
22
23
24
25
26
27
28
U3
PIC16LF870-I/SS
1 3
2
X1
4M
R4
1M
RDY
RxD
VCCON
GND
VCC GND
NC
1
2
3
4
5 6
7
U5
TS01tx
Vcc
R11
22k
R12
10k
ICSP6
VPP
VDD
GND
PGD
PGC
PGM
1
2
3
4
5
6
J2
VDD
OUT VSS
NC
2
1 4
3
U4
S-80818CLNB
R10
10k
C8
0.1
1
2
3 4
5
6
SW2
219-3MST
1
2
3
4
5
6
7
8
9
10
B10B-XH-A
J1
1
2
4
8
C
C
5
6
1
2
3
4
SW1
S-7010EA
10k
R1
10k
R2
10k
R3
10k
R5
Vcc
10k
R6
10k
R7
10k
R8
10k
R9
2
1 3
DTC114YE
Q1
220
R14
Vcc
RD 12
SML-010LT
D1
10k
R13
+2V
+2V
+2V
+2V
+2V
0.1
C5
0.1
C7
Vin
GND /CE
Vout
3
2 4
1
U2
R1122N201A
+B
OI G
3
21
TA78M05F
U1
0.1
C4
0.1
C2
+B
2 1
47u 25V
C1
2 1
10u 10V
C3
2 1
10u 10V
C6
2 1
C9
10u 10V
製品の故障や誤動作が直接人命に関わるような使い方は絶対にしないで下さい
http://www.nomura-e.co.jp e-mail:engineer@nomura-e.co.jp
242-0023 TEL:046-244-0041 FAX:046-244-3551
/418

Never use such a way that product malfunction or malfunction directly relates to human life.
Nomura Engineering Co.,Ltd. http://www.nomura-e.co.jp e-mail:info@nomura-e.co.jp
〒242-0023 Kanagawa prefecture Yamato shibuya 1 - chome 7-2
TEL: 046-244-0041 FAX: 046-244-3551
8/14
2017/12/04 Rev.2.0
TS01E 8sw communication system
5. About the receiver (TS01Erx8sw- * RXBD (S) - #)
When the transmitter is turned on, the receiver application board of TS01E (common
with TS 02 E) activates the corresponding output terminals IO 1 to IO 8 and the LED
lights up.
The output can handle loads up to 1A, but when multiple IO1 to IO8 are on, the total
should not exceed 2A.
5 V to 30 V can be supplied to power supply B +. The power supply contains anti-reverse
diode and ignition noise absorbing element.
・output
Output 8 contact ON / OFF Active "H"
"H" period is 2.5 seconds. However, when a valid signal can be received, it is updated
and the "H" period continues.
"L" after 2.5 seconds from receiving OFF
・LED indication
Operating: LED flashing
Received: LED lit
When registering ID: Flashing LED flashing →Blinking
・Change frequency channel
Change with DIP SW 1, 2, 3.
channel
DIP SW1
DIP SW2
DIP SW3
0
OFF
OFF
OFF
1
ON
OFF
OFF
2
OFF
ON
OFF
3
ON
ON
OFF
4
OFF
OFF
ON
5
ON
OFF
ON
6
OFF
ON
ON
DIP SW 4 is the power switch of the TS 02 E wireless module (circuits other than the
module are turned ON / OFF externally).

Never use such a way that product malfunction or malfunction directly relates to human life.
Nomura Engineering Co.,Ltd. http://www.nomura-e.co.jp e-mail:info@nomura-e.co.jp
〒242-0023 Kanagawa prefecture Yamato shibuya 1 - chome 7-2
TEL: 046-244-0041 FAX: 046-244-3551
9/14
2017/12/04 Rev.2.0
TS01E 8sw communication system
・ID registration
Change with DIP SW 1, 2, 3.
ID registration
DIP SW1
DIP SW2
DIP SW3
ON
OFF
ON
ON
1) With the DIPSW 1, DIPSW 2, DIPSW 3 ON, turn on the receiver.
2) The LED flashes 4 times rapidly. Then it will slowly blink.
3) Place the transmitter in the transmit state.
4) The LED repeatedly flashes rapidly. (Temporary registration)
5) Turn off the power of the receiver after turning off DIPSW 1, DIPSW 2, and DIPSW 3.
(Completion of registration)
Up to 10 ID registration.
6) Turn on the power again.
・ID erase
1) With the DIPSW 1, DIPSW 2, DIPSW 3 ON, turn on the receiver.
2) The LED flashes 4 times rapidly. Then it will slowly blink.
3) Turn off DIPSW1, DIPSW2, DIPSW3.
4) The LED flashes 10 times rapidly. Then it will slowly blink.
5) Turn off the power of the receiver.
・Notes
To cancel ID registration / erasing procedure, please turn OFF the receiver power while
turning on DIPsw 1, DIPsw 2, DIPsw 3.

Never use such a way that product malfunction or malfunction directly relates to human life.
Nomura Engineering Co.,Ltd. http://www.nomura-e.co.jp e-mail:info@nomura-e.co.jp
〒242-0023 Kanagawa prefecture Yamato shibuya 1 - chome 7-2
TEL: 046-244-0041 FAX: 046-244-3551
10/14
2017/12/04 Rev.2.0
TS01E 8sw communication system
・TS01rx - 8SW pin assignment
This shows the name and function of the J2 terminal of TS01rx.
Logic is 2 V CMOS logic (L: 0 to 0.3 V, H: 1.6 to 2 V) unless otherwise
specified.
J2 terminal name function
1 IO1 output, active H
2 IO2 output, active H
3 IO 3 output, active H
4 IO4 output, active H
5 IO5 output, active H
6 IO6 output, active H
7 IO7 output, active H
8 IO8 output, active H
9 MCLR (external reset input active L), unused open
10 SYS1 (output H during transmission), unused open
11 unused open
12 IND status display output, active H
13 Vdd in Power supply 2.0 V input 14 short and short
14 Vdd out Power supply 2.0 V output external use 10 mA or less
15 B + Power supply input 2.1 V to 7.0 V ★Inverse contact
Caution
16 GND Ground
17 SET 1 setting switch 1 input, active L
18 SET 2 setting switch 2 input, active L
19 SET 3 setting switch 3 input, active L
20 SYS 4 use prohibited open
★Vdd out can be use the regulated 2.0 V power supply externally.
★B + should never supply reverse voltage or voltage exceeding 7V.
★Connect the DIP switch from SET 1 to SET 3.
★In addition to B + of 15 pins, please never supply 2.0 V or more.
★Be sure to short-circuit 13 and 14 pins and use them. Please note that it will not
operate unless a short circuit is made.

Never use such a way that product malfunction or malfunction directly relates to human life.
Nomura Engineering Co.,Ltd. http://www.nomura-e.co.jp e-mail:info@nomura-e.co.jp
〒242-0023 Kanagawa prefecture Yamato shibuya 1 - chome 7-2
TEL: 046-244-0041 FAX: 046-244-3551
11/14
2017/12/04 Rev.2.0
TS01E 8sw communication system
・TS01rx-8SW RXBD(S)
You can use TS02E's 8sw reception board.
Besides this, there is also an NWP type (RX - # - NWP) which is in a
waterproof case.
* For details, please refer to each 8sw reception board specification sheet of
TS02E.
To connect the cable to the plug-in type
terminal block, insert the thin (-)
adjustment screwdriver into the
horizontal square hole and lock / unlock
it. (Corresponding to AWG 26 - 20)

Never use such a way that product malfunction or malfunction directly relates to human life.
Nomura Engineering Co.,Ltd. http://www.nomura-e.co.jp e-mail:info@nomura-e.co.jp
〒242-0023 Kanagawa prefecture Yamato shibuya 1 - chome 7-2
TEL: 046-244-0041 FAX: 046-244-3551
12/14
2017/12/04 Rev.2.0
TS01E 8sw communication system
・TS01rx-8SW RXBD(S) reference circuit diagram
htt!2010.9.28 Rev. 1.2"
!TS01rx8swBD
A
B
C
D
E
F
G
H
1234567891011
A
B
C
D
E
F
G
H
1234567891011
220
220
220
220
220
220
220
220
SML-310VT
SML-310VT
220
SML-310VT
SML-310VT
SML-310VT
SML-310VT
SML-310VT
SML-310VT
SML-310VT
219-4MST
10n
CN-1771130-6P_P
CN-1771130-6P_P
CCF1N5T
RB081L-20
ZS-1039
TA78M15F TA48M033F
0.1 0.1
0.1 0.1
47u25V 33u10V
NDS9948PCH
NDS9948PCH
NDS9948PCH
NDS9948PCH
47k
47k
1k
1k
10k 10k
10k 10k
SMA-J-RA
DTC114YE
DTC114YE
DTC114YE
DTC114YE
DTC114YE
DTC114YE
DTC114YE
DTC114YE
220
SML-310VT
0
0
0
0
0
0
0
0
R24
R26
R27
R28
R29
R30
R31
R32
12
34
56
78
910
11 12
13 14
15 16
17 18
19 20
21
22
U6
TS02A-8SW-SMDS
D1
D9
R33
D2
D3
D4
D5
D6
D7
D8
1
2
3
45
6
7
8
SW1
C1
1
2
3
4
5
6
J1
1
2
3
4
5
6
J2
F1 A C
D10
12
D11
1
3
2
U7
1
3
2
U8
C2 C3
C4 C5
C6 C7
1
2
3
45
6
7
8
U3
1
2
3
45
6
7
8
U2
1
2
3
45
6
7
8
U9
1
2
3
45
6
7
8
U10
R11
R12
R1
R2
R3 R4
R5 R6
TP1TP3
J3
1
23
Q1
1
23
Q2
1
23
Q3
1
23
Q4
1
23
Q5
1
23
Q6
1
23
Q7
1
23
Q8
R7
D12
R34
R35
R36
R37
R8
R9
R10
R13
Note:
1) Unless otherwise indicated, all resistor values are in ohm,
all capacitor values are in microfarads, and all inductor
values are in microhenrys.
2) Components without value are not placed on the board. TS02E-8swRXBD_p3-12010/09/15 11:42:37 1/1
Nomura Engineering Co., Ltd.
DWG NO.SIZE A3
ISSUED
DESIGNED
APPROVED
SIGNATURES DATE
Confidential Proprietary
io1
io4
io8
MCLR SYS1
cnt1
VDDi VDDo
+B GND
chg1 chg2
sys3 sys4
GND
io3
io5
io2
io7
io6
cnt2
VCC
VCC
I
G
O I
G
O
S1
S2
G1
G2
D1
D2
D1
D2
S1
S2
G1
G2
D1
D2
D1
D2
S1
S2
G1
G2
D1
D2
D1
D2
S1
S2
G1
G2
D1
D2
D1
D2
+3.3V
+3.3V
+3.3V
J1-1 out1
J1-2 out2
J1-3 out3
J1-4 out4
J1-5 out5
J1-6 out6
J2-1 out7
J2-2 out8
J2-3,4 Vcc
J2-5,6 GND
BDD-P :U2,3,9,10 NDS9948 R5,6 unmount R3,4 10k
R8,9 mount R10,13 unmount
R34,36 0ohm R35,37 unmount
BDD-N :U2,3,9,10 FDS9945 R3,4,5,6 100k
JP1 open JP2 short
R8,9 unmount R10,13 mount
D1-D9 A-K rotate
EXT ANT
RSSI IND RX IND
製品の故障や誤動作が直接人命に関わるような使い方は絶対にしないで下さい
http://www.nomura-e.co.jp e-mail:engineer@nomura-e.co.jp
242-0023 TEL:046-244-0041 FAX:046-244-3551
/
910

Never use such a way that product malfunction or malfunction directly relates to human life.
Nomura Engineering Co.,Ltd. http://www.nomura-e.co.jp e-mail:info@nomura-e.co.jp
〒242-0023 Kanagawa prefecture Yamato shibuya 1 - chome 7-2
TEL: 046-244-0041 FAX: 046-244-3551
13/14
2017/12/04 Rev.2.0
TS01E 8sw communication system
6. Precautions
★Precautions on Radio Law
Never remove the antenna, open the case and remodel the device as it is prohibited by law
Do not peel off certification label conforming to technical standards. Those without a label
are prohibited to use.
Since it does not conform to the radio wave law outside Japan, please use it in Japan.
★Handling precautions
Never use such a way that product malfunction or malfunction directly relates to human
life.
Never reverse the power supply as doing such will cause the equipment to malfunction.
Never put the device in strong shock or dipping it in water or other solution as doing that
will cause damage.
Please do not disassemble and remodel it.
Please do not pull the antenna strongly.

Never use such a way that product malfunction or malfunction directly relates to human life.
Nomura Engineering Co.,Ltd. http://www.nomura-e.co.jp e-mail:info@nomura-e.co.jp
〒242-0023 Kanagawa prefecture Yamato shibuya 1 - chome 7-2
TEL: 046-244-0041 FAX: 046-244-3551
14/14
2017/12/04 Rev.2.0
TS01E 8sw communication system
7. Change history
2016/08/09 Rev 2.0 Contents major revision
Table of contents
Popular Conference System manuals by other brands

Vocera
Vocera B3000 Quick reference guide

Q-SYS
Q-SYS NV-32-H Hardware user manual

Lucent Technologies
Lucent Technologies MERLIN LEGEND manual

Audio Technica
Audio Technica ATUC-50 instruction manual

Edin
Edin Univox IR 1411 user guide

Lenovo
Lenovo ThinkSmart Hub 500 User guide and hardware maintenance manual

Clear One
Clear One Collaborate installation guide

Clear One
Clear One COLLABORATE Room Installation and setup manual

Talkaphone
Talkaphone EC-6 Installation and operation manual

Vanguard
Vanguard V25-70 Series quick start guide

Clear-Com
Clear-Com trilogy Mercury quick start guide

Clear One
Clear One Chat 50 quick start guide