Norcross DS900SP User manual

NorCross®Sonic-Laser®Scale SP
Instruction Manual
The Sonic-Laser Scale has an accuracy of plus or
minus 3%. Therefore, it should only be used as a
guide to estimate a fish’s length. If the fish is close to
the legal size regulation in your fishing area, it is rec-
ommended that you use a tape measure or flat meas-
uring board to ensure that the catch is of legal size.
Safety Information:
• Read the following safety information carefully before
attempting to operate this scale.
• Only qualified personnel should perform repairs or serv-
icing not covered in this manual.
• Periodically wipe the case with a dry cloth. Do not use
abrasives or solvents on this scale.
• Do not store in a high temperature environment (auto-
mobile, vehicle or boat dashboard, direct sunlight, etc).
• Want to save yourself hours of aggravation? If so,
then read this manual entirely before attempting
the installation and/or use.
Installing the Battery
1. Using a “Flat Head” Screwdriver, turn the screws on the
battery door counterclockwise until loose.
2. Remove the Battery Cover from the Scale.
3. Attach a “9-Volt” battery (not included) to the battery
plug making sure that battery terminals are properly
aligned with the plug terminals.
4. Reinstall the Battery Cover and turn the screws on the
battery door clockwise until “Snug” (do not overtighten).
IMPORTANT:
To ensure the battery cover remains water tight,
coat the battery cover seal with petroleum jelly
(Vaseline®”) each time you replace the battery.
Warning:
Although the scale can be temporarily submerged in water with-
out damage, it does not float. Avoid allowing it to enter water
without having a firm grip on it.

Powering ON
1. Press and Release the “E” button (ENTER) to turn the scale ON.
The scale will perform a self-test by displaying “88.88” for two sec-
onds.
2. When “0.0” is displayed on the screen, the scale is zeroed-out and
ready for normal operation.
Powering OFF
1. Press and Hold the “E” button until “OFF” is displayed on the display.
2. Release the “E” button and the scale will turn OFF.
E
IMPORTANT:
The scale will automatical-
ly turn OFF after 2 minutes
of inactivity.
Changing the Units of Measure
1. Press and Hold “E” and “ ” for 3 seconds. The current unit of
measure will flash.
2. Press either “ ” or “ ” to Change the unit of measure.
3. Press “E” to save and return to normal operation (display will
return to normal operation automatically after 15 seconds).
Normal Operation
1. Press “ ” button to select the operation mode:
Weight Mode
The "WGT" mode is used to measure the weight of the fish. The
scale uses a solid state electronic scale which incorporates no mov-
ing parts.
To Measure the Weight of a Fish
1. Press “ ” button until “WGT” is illuminated.
2. The weight of the fish will be displayed.
E
AUTO Automatically weighs and measures fish
WGT Weighs the fish
LGT Measures the length of the fish
TARE Adjusts the weight readings to deduct the
weight of a bag, bucket, bin, etc.
WGT
IMPORTANT:
To obtain accurate weight readings the
scale must be held steady.
- 2 -
IMPORTANT:
The display will become sluggish below 20 oF (-
7 oC) and nonfunctional below 12 oF (-11 oC). If
you are using the scale under these conditions,
keep the unit warm in between uses.

Length Mode
The "LGT" mode is used to measure the length of the fish. The direc-
tion of the measurement is indicated by a laser pointer and the meas-
urement is calculated using Ultrasound.
To Measure the Length of a Fish
1. Press “ ” button until “LGT” is illuminated.
2. Hold the fish’s tail so that it barely touches a solid object (boat deck, ground, dock,
calm/flat water, etc).
3. The length of the fish will be displayed.
Tare Mode
The "TARE" feature is used to compensate weight readings for weigh bags or containers.
The "TARE" icon will always be ON when the TARE weight is not “0.00”.
Automatic Tare Setup
1. Press “ ” button until “TARE” is illuminated.
2. Pickup the bag or container and press “E”.
3. This weight is now saved as the Zero weight.
Manual Tare Setup
1. Press “ ” button until “TARE” is illuminated.
2. Press and Hold “ ” for 3 seconds. The current TARE setting will
flash.
3. Press “ ” to decrease the setting or “ ” to increase the setting.
4. Press and Hold “E” for 3 seconds to save the setting and return to
normal operation.
5. To reset the Tare weight to “0.00” simply repeat steps 1 through 4.
LGT
TARE
IMPORTANT:
To reset the Tare weight to “0.00”, sim-
ply repeat steps 1 through 3 without
picking up the bag or container
- 3 -
IMPORTANT:
To obtain accurate length readings the Laser pointer can not
have anything blocking it from touching the solid surface that
the tail of the fish is touching. If necessary, slide the laser
pointer away from the body of the scale to give the beam a
clear line of sight.
Trying to obtain length readings over a non-solid surface
(carpeting, choppy water, grass, weeds, soft sand, etc.)
may produce inaccurate readings. The area must be flat
and solid for at least 1 square foot (.3 Meter) around the laser
beam. You MUST hold the scale steady while using the length
measurement feature.
THE LENGTH MEASUREMENT FEATURE WILL NOT
FUNCTION PROPERLY IF THIS IS NOT FOLLOWED.

AUTO Mode
The "AUTO" feature is used to calculate the weight and length
of the fish and review the results upon completion.
1. Press “ ” button until “AUTO” is illuminated and “WGT” flashes
on the LCD.
2. Pick up the fish.
3. Once a steady reading is obtained, press and release “E”.
4. “LGT” will flash on the LCD.
5. Hold the fish’s tail so that it barely touches a solid object (boat
deck, ground, dock, calm/flat water, etc).
6. Press and release “E”.
7. “WGT” will flash on the display along with the weight of the fish.
8. Press and release “E”.
9. “LGT” will flash on the display along with the length of the fish.
10. Press and release “E” to return to normal operation.
Service & Warranty
If you have questions about this product please visit our Customer Service Center on
our website at www.norcrossmarine.com (You may also call us toll free at 888-667-
2767) where you can find information relating to:
• Warranty Details
• Warranty Registration
• Troubleshooting
• Product Knowledgebase
• Product Specifications
• Parts & Accessories
FCC Notice
This device complies with FCC Part 15 Rules and Industry Canada RSS210 Issue 2
Regulations. Operation is subject to the following tow conditions:
• this device may not cause harmful interference; and,
• this device must accept any interference received, including interference that may
cause undesired operation
Changes or modifications not expressly approved by NorCross Marine Products, Inc,
could void the user’s authority to operate the equipment.
E
WGT
AUTO
LGT
Made in China. Tested to comply with FCC, CE
and ROHS standards. Visit our website for compli-
ance and warranty information. All Specifications
and Prices Subject to Change Without Notice.
NorCross Marine Products, Inc
Phone: 888-NorCross (888-667-2767)
www.norcrossmarine.com
Warning:
© 2006 NorCross Marine Products Inc., All Rights Reserved. ALL
unauthorized copying of the content of this manual without the
expressed written consent of NorCross Marine Products, Inc will be
prosecuted to the fullest extent of the law.
To be eligible for the 2 year product warranty, you must register
your product within 15 days of purchase. Please visit our
Customer Service Center on our website to register. Make a copy
of your original purchase receipt and store it in a safe place. You
will need to present it in the rare occurrence that you need to send
your product in for service.
Table of contents
Popular Measuring Instrument manuals by other brands

Omicron Lab
Omicron Lab Bode 100 Detailed Functional & Calibration Check

Doran
Doran SMARTLINK 360SLT2 manual

S+S Regeltechnik
S+S Regeltechnik PREMASGARD 711 Series Operating Instructions, Mounting & Installation

SAS
SAS LUMIRANK X2 RACELINK installation guide

Hach
Hach DR 6000 user manual

Leonard
Leonard LMS-188-4P operating instructions