Nordis NDI-07ONF User manual

Thank you for choosing our product.
Please read this Owner’s Manual carefully before operation and
retain it for future reference.
Owner's Manual
Original Instructions
Split Air Conditioner
NDI-07ONF/NDO-07ONF
NDI-09ONF/NDO-09ONF
NDI-12ONF/NDO-12ONF
NDI-18ONF/NDO-18ONF
NDI-24ONF/NDO-24ONF


Content
Operation Notices
Safety precautions for installing and relocating the unit.......................................
This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Parts name ........................................................................................................... 6
1
Screen Operation Guide
Buttons on remote controller ................................................................................ 7
Precautions...........................................................................................................
Introduction for buttons on remote controller........................................................ 7
Function introduction for combination buttons...................................................... 9
Replacement of batteries in remote controller.....................................................10
10
11
12
15
16
17
17
18
19
23
26
26
27
27
Maintenance
Emergency operation ..........................................................................................
Malfunction
Clean and maintenance.......................................................................................
Installation Notice
Malfunction analysis ............................................................................................
Installation dimension diagram ...........................................................................
Tools for installation.............................................................................................
Selection of installation location ..........................................................................
Installation
Requirements for electric connection ..................................................................
Installation of indoor unit......................................................................................
Installation of outdoor unit ...................................................................................
Vacuum pumping.................................................................................................
Leakage detection ...............................................................................................
Test and operation
Check after installation ........................................................................................
Test operation......................................................................................................

Explanation of Symbols
After verification, the defect of product is directly caused by corrosive gas;
4.After verification, defects are due to improper operation during transportation of
product;
5.Operate, repair, maintain the unit without abiding by instruction manual or related
regulations;
6.
7.
Indicates a hazardous situation that, if not avoided, will
result in death or serious injury.
Indicates a hazardous situation that, if not avoided, could
result in death or serious injury.
Indicates a hazardous situation that, if not avoided, may
result in minor or moderate injury.
Indicates important but not hazard-related information,
used to indicate risk of property damage.
Indicates a hazard that would be assigned a signal word
WARNING or CAUTION.
Exception Clauses
After verification, the problem or dispute is caused by the quality specification or
performance of parts and components that produced by other manufacturers;
The damage is caused by natural calamities, bad using environment or force
majeure.
If it needs to install, move or maintain the air conditioner, please contact dealer
or local service center to conduct it at first. Air conditioner must be installed,
moved or maintained by appointed unit. Otherwise, it may cause serious
damage or personal injury or death.
When refrigerant leaks or requires discharge during installation, maintenance,
or disassembly, it should be handled by certified professionals or otherwise in
compliance with local laws and regulations.
Damage the product due to improper use or misuse of the product;
Alter, change, maintain or use the product with other equipment without abiding
Manufacturer will bear no responsibilities when personal injury or
property loss is caused by the following reasons.
1.
2.
by the instruction manual of manufacturer;
3.
DANGER
WARNING
CAUTION
NOTICE

Operation and Maintenance
1
Precautions

Precautions
Do not block air outlet or air inlet. It may cause
malfunction.
●
●
Power cord is overheating or damaged.
●Circuit break trips off frequently.
There’s abnormal sound during operation.
●
●
Air conditioner gives off burning smell.
Indoor unit is leaking.
When turning on or turning off the unit by emergency
operation switch, please press this switch with an insulating
object other than metal.
Do not spill water on the remote controller, otherwise the
remote controller may be broken.
When below phenomenon occurs, please turn off air
conditioner and disconnect power immediately, and then
contact the dealer or qualified professionals for service.
Do not extend fingers or objects into air inlet or air
outlet. It may cause personal injury or damage.
WARNING
If the air conditioner operates under abnormal conditions,
it may cause malfunction, electric shock or fire hazard.
Do not step on top panel of outdoor unit, or put heavy
objects. It may cause damage or personal injury.
Do not repair air conditioner by yourself. It may cause
electric shock or damage. Please contact dealer when
you need to repair air conditioner.
2
Maintenance must be performed by qualified
professionals. Otherwise, it may cause personal injury
or damage.

Do install the circuit break. If not, it may cause malfunction.
According to the local safety regulations, use qualified
power supply circuit and circuit break.
WARNING
Must follow the electric safety regulations when installing
the unit.
Be sure to cut off the power supply before proceeding
any work related to electricity and safety.
Don't use unqualified power cord.
Make sure the power supply matches with the requirement
of air conditioner. Unstable power supply or incorrect wiring
may result in electric shock, fire hazard or malfunction.
Please install proper power supply cables before using the
air conditioner.
Properly connect the live wire, neutral wire and
grounding wire of power socket.
Installation must be performed by qualified professionals.
Otherwise, it may cause personal injury or damage.
Attachment
An all-pole disconnection switch having a contact separation
of at least 3mm in all poles should be connected in fixed
wiring.
Including an circuit break with suitable capacity, please
note
the following table. Air switch should be included
magnet buckle
and heating buckle function, it can protect
the circuit-short and
overload.
Air Conditioner should be properly grounded. Incorrect
grounding may cause electric shock.
Precautions
3

Precautions
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
The appliance must be positioned so that the plug is
accessible.
The air conditioner is the first class electric appliance. It
must be properly grounding with specialized grounding
device by a professional. Please make sure it is always
grounded effectively, otherwise it may cause electric shock.
If the length of power connection wire is insufficient, please
contact the supplier for a new one. Avoid extending the
wire by yourself.
All wires of indoor unit and outdoor unit should be
connected by a professional.
The appliance shall be installed in accordance with
national wiring regulations.
Installation must be performed in accordance with the
requirement of NEC and CEC by authorized personnel
only.
WARNING
The yellow-green wire in air conditioner is grounding
wire, which can't be used for other purposes.
The grounding resistance should comply with national
electric safety regulations.
The temperature of refrigerant circuit will be high, please
keep the interconnection cable away from the copper
tube.
Do not put through the power before finishing installation.
4

Precautions
The indoor unit should be installed close to the wall.
Instructions for installation and use of this product are
provided by the manufacturer.
WARNING
If you need to relocate the air conditioner to another
place, only the qualified person can perform the work.
Otherwise, it may cause personal injury or damage.
For the air conditioner without plug, an circuit break
must be installed in the line.
For the air conditioner with plug, the plug should be
reachable after finishing installation.
Select a location which is out of reach for children and
far away from animals or plants.If it is unavoidable,
please add the fence for safety purpose.
Working temperature range
NOTICE:
5
Indoor side DB/WB(ć)
Maximum cooling
Outdoor side DB/WB(ć)
32/23 43/26
Maximum heating 27/- 24/18
● The operating temperature range (outdoor temperature) for cooling only unit is
18ć ~ 43ć ; for heat pump unit is -7ć ~ 43ć .

Parts Name
Indoor Unit
Outdoor Unit
remote controller
air inlet
handle
air outlet
6
NOTICE:
Actual product may be different from above graphics, please refer
to actual products.
air inlet
panel
aux.button
horizontal louver
air outlet
(Display content or position may evobamorftnereffidfidebebyamnoitisoprotnetnocyalpsiD( ferent from above
graphics, please refer to actual products)graphics, please refer to actual products)
temp. indicator
power indicator
receiver window

Introduction for buttons on remote controller
Buttons on remote controller
7
1
2
5
4
6
7
8
11
12
9
On/Off button
▲/ button
3Fan button
Swing button
X-Fan button
Turbo button
Light button
10
Temp button
I Feel button
Timer button
Sleep button
Mode button
▲
Send signal
Turbo mode
8ćheating function
Set temperature
Set time
TIMER ON /TIMER OFF
Child lock
Up & down swing
Set fan speed
Light function
Temp. display type
:Set temp.
:Outdoor ambient temp.
:Indoor ambient temp.
Sleep mode
Heat mode
Fan mode
Dry mode
Cool mode
Auto mode
Operation mode
I feel function
X-fan mode
health function
ventilation operation
2
5
7
9
4
12
3
1
6
8
10
11
NOTICE: “ ” This is a general remote controller. Some models have this function while some
do not. Please refer to the actual models.

5Swing button
Press this button to set up & down swing angle.
Introduction for buttons on remote controller
8
Note:
●
●
After putting through the power, the air conditioner will give out a sound.
Operation indicator " " is ON (red indicator). After that, you can operate the air
conditioner by using remote controller.
● Under off status, set temperature and clock icon will be displayed on the display
of remote controller (If timer on, timer off and light functions are set, the corre-
time); Under on status, the display will show the corresponding set function icons.
Under on status, pressing the button on the remote controller, the signal icon " "
on the display of remote controller will blink once and the air conditioner will give
out a “di” sound, which means the signal has been sent to the air conditioner.
sponding icons will be displayed on the display of remote controller at the same
▲
▲ / button
4
▲Press
▲
/ button to increase/decrease set temperature. In AUTO mode,
, to , then back to Auto.
3Fan button
This button is used for setting Fan Speed in the sequence that goes from AUTO,
1On/Off button
Press this button to turn on the unit. Press this button again to turn off the unit.
* Note: Only for models with heating function.
●
2Mode button
Each time you press this button,a mode is selected in a sequence that goes from
AUTO, COOL, DRY, FAN, and HEAT *, as the following:
AUTO COOL DRY FAN HEAT*
This is a general use remote controller, it could be used for the air conditioners
with multifunction; For some function, which the model doesn't have, if press
the corresponding button on the remote controller that the unit will keep the
original running status.
set temperature is not adjustable.
When setting Timer On or Timer Off, pres
▲
s "▲" or " " button to adjust the time.
6Sleep button
Under Cool, Heat or Dry mode, press this button to turn on Sleep function.
Press this button again to cancel Sleep function. Under Fan and Auto modes, this
function is unavailable.

Press this button to start I FEEL function and " " will be displayed on the remote
controller. After this function is set, the remote controller will send the detected
ambient temperature to the controller and the unit will automatically adjust the
indoor temperature according to the detected temperature. Press this button again
to close I FEEL function and " " will disappear.
Note:
●
Outdoor temperature display is not available for some models. At that time, indoor
unit receives " " signal, while it displays indoor set temperature.
will change quickly if holding " " or " " button). Time setting range is 0.5~24hours.
Press this button again to confirm timer setting and the characters of HOUR ON
(OFF)will stop flashing.
If the characters are flashing but you haven’t press timer button,timer setting
status will be quit after 5s.If timer is confirmer, press this button again to cancel
timer.
● Under ON status, press this button to set timer OFF; Under OFF status, press
this button to set timer ON.
● Press this button once and the characters of HOUR ON (OFF) will flash to be
displayed. Meanwhile, press " " button or " " button to adjust timer setting (time
Press this button, you can see indoor set temperature, indoor ambient temperature
on indoor unit’s display. The setting on remote controller is selected circularly as below:
no display
Turbo button
Press this button to activate / deactivate the Turbo function.
Introduction for buttons on remote controller
9
Press this button in COOL or DRY mode to turn on X-fan function.
Press this button to
turn on the display's light and press this button again to turn
off the display's
light.
When this function is started up, indoor fan will still operate at low fan speed for a
while after turning off the unit by remote controller.
Function introduction for combination buttons
Combination of " " and " " buttons: About lock
Press " " and " "
buttons simultaneously 3s to lock or unlock the keypad. If the remote
three times.
controller is locked, is displayed. In this case, pressing any button, blinks
▲
▲
▲
▲
▲
▲
▲
▲
7Temp button
8
10
9
12
11
Timer button
I Feel button
Light button
X-Fan button

Emergency operation
If remote controller is lost or damaged, please use aux. button to turn on
or turn off the air conditioner. The operation in details is as below:
air conditioner. When the air conditioner is turned on, it will operate under
auto mode.
aux. button
panel
WARNING:
Use insulated object to press the auto button
Replacement of batteries in remote controller
10
Function introduction for combination buttons
Combination of "MODE" and " " buttons:
About switch between Fahrenheit and centigrade
Nixie tube on the remote controller displays
"
SE
"
. Repeat the operation to quit the function.
At unit OFF, press "MODE" and " " buttons simultaneously to
switch between ćand .
Combination of "TEMP" and "TIMER" buttons:
About Energy-saving Function
Press "TEMP" and "TIMER" simultaneously in COOL mode to start Hnergy-saving function.
(46if Fahrenheit is adopted). Repeat the operation to quit the function.
Combination of "TEMP" and "TIMER" buttons:
About 8
ć
Heating Function
Press "TEMP" and "
TIMER
" simultaneously in HEAT mode to start 8
ć
Heating Function
Nixie tube on the remote controller displays
"
"
and a selected temperature of
"
8ć
"
.
WIFI Function
Press "MODE" and "TURBO" button simultaneously to turn on or turn off WIFI
remote controller; Long press "MODE" and "TURBO" buttons simultaneously for
10s, remote controller will send WIFI reset code and then the WIFI function will be
turned on. WIFI function is defaulted ON after energization of the remote controller.
function. When WIFI function is turned on, the " " icon will be displayed on
1. Press the back side of remote controller marked
the cover of battery box along the arrow direction.
2. Replace two 7# (AAA 1.5V) dry batteries, and
make sure the position of "+" polar and "-" polar
are correct.
3. Reinstall the cover of battery box.
signal sender battery
Cover of battery box
remove
reinstall

NOTICE: Checking before use-season/Checking after use-season
■
■ After removing the filter, do not touch fins to avoid injury.
■
WARNING
The filter should be cleaned every three months. If there is much dust in the
operation environment, clean frequency can be increased.
Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard.
Clean and Maintenance
1
2
3
4
●
●
Remove the filter as indicated
in the fig.
Install the filter and then close the panel
cover tightly.
11
■
■
Use dust catcher or water to clean the filter.
When the filter is very dirty, use the water
(below 45ć) to clean it, and then put it in
a shady and cool place to dry.
Open panel
Pull out the panel to a certain
angle as shown in the fig.
■
■
●Do not remove the panel when cleaning it.
WARNING
NOTICE:
Clean surface of indoor unit
When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth
or wet cloth to wipe it.
Turn off the air conditioner and disconnect the power before cleaning the air
conditioner to avoid electric shock.
Do not wash the air conditioner with water to avoid electric shock.
Do not use volatile liquid to clean the air conditioner.
Do not use liquid or corrosive detergent clean the appliance and do not
splash
water or other liquid onto it, otherwise,it may damage the plastic
components, even cause electric shock.

Malfunction analysis
General phenomenon analysis
Please check below items before asking for maintenance. If the malfunction still
Phenomenon Check items Solution
● Whether it's interfered severely
(such as static electricity, stable
voltage)?
● Pull out the plug. Reinsert
the plug after about 3min, and
then turn on the unit again.
●
● Signal receiving range is 8m.
● ● Remove obstacles.
●●
Select proper angle and point
the remote controller at the re-
ceiving window on indoor unit.
● Check the batteries. If the
power of batteries is too low,
please replace them.
● No display when operating
remote controller?
● Check whether remote cont-
roller appears to be damaged.
If yes, replace it.
●
● Fluorescent lamp in room?
● Air inlet or air outlet of indoor
unit is blocked? ● Eliminate obstacles.
●
● ● In order to prevent blowing
out cold air, indoor unit will be
started after delaying for sev-
eral minutes, which is a nor-
mal phenomenon.
12
Whether remote controller is
within the signal receiving
range?
Whether there are obstacles?
Indoor unit
can’t receive
remote
controller’s
signal or
remote
controller
has no
action.
Whether remote controller is
pointing at the receiving
window?
Is sensitivity of remote contro-
Take the remote controller
close to indoor unit.
fluorescent
and then try it again.
Under heating mode, indoor
temperature is reached to set
temperature?
Heating mode is turned on just
now?
No air
emitted
from
indoor
unit
●
● After reaching to set temper-
ature, indoor unit will stop bl-
owing out air.
ller low; fuzzy display and no
display?

Malfunction analysis
13
● Power failure?
● Is plug loose?
● Air switch trips off or fuse is
burnt out?
● Wiring has malfunction?
● Unit has restarted immediately
after stopping operation?
● Whether the function setting
for remote controller is
correct?
● Reset the function.
● Wait for 3min, and then turn
on the unit again.
● Ask professional to replace it.
● Ask professional to replace
air switch or fuse.
● Reinsert the plug.
● Wait until power recovery.
Air condit-
ioner can’t
operate
Mist is em-
itted from
indoor unit’s
air outlet
● Indoor temperature and hum-
idity is high?
● Because indoor air is cooled
rapidly. After a while, indoor
temperature and humidity will
be decrease and mist will
disappear.
Phenomenon Check items Solution
Set temper-
ature can’t
be adjusted
● Unit is operating under auto
mode?
● Temperature can’t be adju-
sted under auto mode.
Please switch the operation
mode if you need to adjust
temperature.
● Your required temperature
exceeds the set temperature
range?
● Set temperature range:
16ć~30ć.
Cooling
(heating)
effect is
not good.
V● oltage is too low? ● Wait until the voltage
resumes normal.
● Filter is dirty?
● Set temperature is in proper
range?
● Adjust temperature to proper
range.
● Door and window are open? ● Close door and window.
Odours are
emitted
● Whether there’s odour source,
such as furniture and cigarette,
etc.
● Eliminate the odour source.

f
Malfunction analysis
14
E1/E5/E8/U8/H3/H6
C5/F0/F1/F2
T
Error Code
’ f
f
WARNING
f
“
A
f
A
f

15
Installation dimension diagram
Drainage pipe
At least 250cm
At least 15cm
At least 50cm
At least 50cm
At least
30cm
At least 300cm
Space to the obstruction
Space to the
obstruction
Space to the
obstruction
Space to the ceiling
Space to the obstruction
Space to the obstruction
At least 30cm
At least 15cm
At least 15cm
Space to the wall
Space to the wall
Space to the wall
At least 200cm

16
Safety precautions for installing and relocating the unit
To ensure safety, please be mindful of the following precautions.
Warning
When installing or relocating the unit, be sure to keep the refrigerant
circuit free from air or substances other than the specified refrigerant.
Any presence of air or other foreign substance in the refrigerant circuit will cause
system pressure rise or compressor rupture, resulting in injury.
When installing or moving this unit, do not charge the refrigerant which
is not comply with that on the nameplate or unqualified refrigerant.
Otherwise, it may cause abnormal operation, wrong action, mechanical
malfunction or even series safety accident.
When refrigerant needs to be recovered during relocating or repairing the
unit, be sure that the unit is running in cooling mode.Then, fully close the
valve at high pressure side (liquid valve).About 30-40 seconds later, fully
close the valve at low pressure side (gas valve), immediately stop the unit
and disconnect power. Please note that the time for refrigerant recovery
should not exceed 1 minute.
If refrigerant recovery takes too much time, air may be sucked in and cause
pressure rise or compressor rupture, resulting in injury.
During refrigerant recovery, make sure that liquid valve and gas valve are
fully closed and power is disconnected before detaching the connection pipe.
If compressor starts running when stop valve is open and connection pipe is not
yet connected, air will be sucked in and cause pressure rise or compressor
rupture, resulting in injury.
When installing the unit, make sure that connection pipe is securely
connected before the compressor starts running.
If compressor starts running when stop valve is open and connection pipe is not
yet connected, air will be sucked in and cause pressure rise or compressor
rupture, resulting in injury.
Prohibit installing the unit at the place where there may be leaked corrosive
gas or flammable gas.
If there leaked gas around the unit, it may cause explosion and other accidents.
Do not use extension cords for electrical connections. If the electric wire
is not long enough, please contact a local service center authorized
and ask for a proper electric wire.
Poor connections may lead to electric shock or fire.
Use the specified types of wires for electrical connections between the
indoor and outdoor units. Firmly clamp the wires so that their terminals
receive no external stresses.
Electric wires with insufficient capacity, wrong wire connections and insecure
wire terminals may cause electric shock or fire.
This manual suits for next models
9
Table of contents
Other Nordis Air Conditioner manuals
Popular Air Conditioner manuals by other brands

GE
GE AGM24DH Owner's manual and installation instructions

Toshiba
Toshiba TCB-SIR41U-E installation manual

Haier
Haier HBU-18CA03T3 Operation & installation manual

Panasonic
Panasonic S-M20PY3E installation instructions

dirna Bergstrom
dirna Bergstrom bycool green Series Troubleshooting

Gree
Gree Ultra Heat GMV-VQ72W/A-F owner's manual