Norstar NT8B79FDE6 User manual

Doorphone
Installation
Guide
.


Norstar Doorphone Installation Guide
i
This digital apparatus does not exceed the Class B limits for radio noise emissions
from digital apparatus set out in the Radio Interference Regulations for the Canadian
Department of Communications.
FCC Regulations
Radio Frequency Interference
Warning: This equipment generates, uses, and can radiate radio frequency energy,
and if not installed and used in accordance with the instruction manual, may cause
interference to radio communications. It has been tested and found to comply with
the limits for a Class B computing device pursuant to Part 15 of the FCC Rules and
CSA specification C108.8, which are designed to provide reasonable protection
against such interference when operated in a commercial environment. Operation of
this equipment in a residential area is likely to cause interference in which case the
user will be required at his own expense to take whatever measures necessary to
correct the interference.
Note: When the Doorphone is powered by a Station Auxiliary Power Supply instead
of the KSU station port, the Doorphone does not exceed Class A limits for radio
noise emissions.
In the event of equipment malfunction, all repairs will be performed by
Northern Telecom or by one of its authorized dealers.
Address of repair facilities
USA: Canada:
NorthernTelecom NorthernTelecom
ProductService Center 30NorcelcoDrive
640Massman Drive Weston,Ontario
Nashville,Tennessee M9L2X6
37210 Attn: RepairsDepartment
Ph:1-800-466-7835 Ph:416-744-5201FAX: 416-744-5227

Norstar Doorphone Installation Guide
ii

Norstar Doorphone Installation Guide
1
About the Doorphone
What is the Doorphone?
The Doorphone connects to a digital Meridian Norstar™ telephone port to provide
call notification and handsfree communication from a premise entry location to other
stations on the system.
Door opening functionality can be achieved if installed with one of two optional
hardware devices. If an External Relay Module (ERM) is installed, the call will be
ended immediately after the door is opened. If a Door Opening Controller (DOC) is
installed, the call will continue until QUIT or
®
is pressed.
Before Installation
Check the following environment requirements:
For the Doorphone
Temperature -35°to 60°C (-31°to 140°F)
Relative humidity 5% to 95% non-condensing
Background noise up to 70 d BA
Package Check List
Make sure the package contains:
❏
the Doorphone unit with a surface
mount bracket
❏
documentation:
Doorphone Installation Guide
Doorphone User Card
❏
two gaskets Figure 1 – Package Contents
™
Meridian and Norstar are trademarks of Northern Telecom

Norstar Doorphone Installation Guide
2
Installation Overview
Doorphone Compatibility
The Doorphone is compatible with and supports the North American KSU platforms
for DR2, DR3, DR4, DR5, Modular ICS Release 1-T1, Centrex and greater, for 3X8,
Compact and Modular systems.
Installation Overview
The Doorphone will identify itself to the KSU as an M7208 Norstar telephone.
There are five steps to follow when installing a Doorphone:
1. Select a station port for the Doorphone and determine the Directory Number.
2. Program the Station Port Parameters.
3. Wire and Mount the Doorphone.
4. Program the Doorphone.
5. Test the Doorphone.
Ext. 23
Ext. 22
Ext. 21
Figure 2 – Installation Overview

Norstar Doorphone Installation Guide
3
Installation
Step 1: Determine the Doorphone Directory Number
Up to four Doorphones can be installed on a Norstar system. Each is assigned a
Directory Number (DN) by the KSU.
To determine the DN of the port to which the Doorphone will be connected, use the
Maintenance Port/DN Status facility (Modular systems only), or refer to the wiring
charts in the relevant Norstar Installer Guide, or:
1. Ensure Auto Set Relocation feature is turned off.
2. Connect a jack and Norstar telephone to the port.
3. Press
ƒ
•
‚
∆
and record the DN.
4. Disable voice calls by pressing
ƒ
°
°
.
5. Repeat steps 2 to 4 for each Doorphone Port.

Norstar Doorphone Installation Guide
4
Installation
Step 2: Program Station Ports
Norstar configuration must be performed before wiring the Doorphone. Startup
defaults can cause the Doorphone to automatically answer incoming calls which
were not intended to be heard over the Doorphone.
1. Enter Norstar Configuration programming from a Norstar M7310 or M7324
telephone. To do so,
• Press
ƒ••ÇØˆÏÈÌ
.
• Enter the configuration password.
• The default is
ÇØˆÏÈÌ
, or
¤flfl‹››
.

Norstar Doorphone Installation Guide
5
Installation
Step 2: Program Station Ports (cont’d)
2. Perform the following configuration assignments. Refer to the
Norstar Installer Guide for details.
A. Configuration
1.Trunk/Line Data
❏ensure the Doorphone is not the prime set for any line
2. Line Access
❏remove all line appearances and line ringing assigned to the Doorphone. If you
do not remove all line appearances, incoming calls will automatically be
answered by the Doorphone.
❏ensure no answer DNs are assigned to the Doorphone
❏remove all line pools assigned to the Doorphone
❏assign only one intercom button to the Doorphone
❏assign the intercom (I/C) as the Doorphone’s prime line
Note: Two intercom buttons is acceptable, if this is the minimum offered in
**CONFIG programming. Prime line “none” is acceptable if Intercom is not
offered. This is dependent on your system software release.
B. General admin
2. Names
❏assign a name to each Doorphone (e.g., Front, Gate, etc.)

Norstar Doorphone Installation Guide
6
Installation
Step 2: Program Station Ports (cont’d)
4. Direct Dial
❏ensure the Doorphone is not assigned as a Direct Dial telephone
5. Capabilities
❏enable Full Handsfree
❏disable Auto Handsfree
❏enable Paging
Note: The Doorphone may be used as a paging device by assigning a page
zone, but it should not be assigned the page zone used for its own door chimes.
❏disable the Auxiliary Ringer
❏ensure the Doorphone does not Call Forward on Busy
❏ensure the Doorphone does not Call Forward on No Answer
❏ensure the Do not disturb feature (DND) is turned off
❏ensure Hotline is assigned “None”
6. Service Modes
❏ensure the Doorphone is not a control set
❏ensure the Doorphone is not assigned as an extra-dial set
❏ensure the Doorphone is not assigned as a ringing set
Note: Configuration headings may not be exactly as shown, depending on the KSU
software version.

Norstar Doorphone Installation Guide
7
Installation
Step 2: Program Station Ports (cont’d)
3. Ensure that all telephones to receive Doorphone call chimes are included in the
desired page zone and those for which Doorphone chimes are not desired are
excluded. Valid page zones for Doorphone chimes are zones 1, 2 and 3.
Note: The Norstar Page feature may be used to deliver the Doorphone chime
immediately or after a prescribed number of rings. It is good practice to assign more
than one telephone to the page zone used by the Doorphone.
4. Exit Norstar Programming by pressing
®
.

Norstar Doorphone Installation Guide
8
Installation
Step 3: Wire and Mount the Doorphone
The Doorphone can be mounted in a standard recessed double-gang electrical box
for flush mounting or surface mounted using the enclosed optional surface mount
bracket.
The Doorphone should be mounted at approximately shoulder height in the absence
of other specifications, such as compliance with local handicapped access
regulations, if required.
To wire and mount the Doorphone on a wall:
1. Select a location within 300 m (1000 ft) of the KSU. This distance can be
increased to 780 m (2600 ft) with the connection of a Station Auxiliary Power
Supply (SAPS) to the Doorphone.
2. Remove the Doorphone’s face plate.
If the wiring between the Doorphone and the KSU is routed outside a building
such as aerial or buried cable then protection devices must be installed at each
end of the exposed cable for safety and protection. Northern Telecom
recommends the ITW LINX MP1A–90–27 secondary protector for this purpose.

Norstar Doorphone Installation Guide
9
Installation
Step 3: Wire and Mount the Doorphone (cont’d)
3. Surface Mounting/Flush Mounting Options:
If the Doorphone is mounted in a location that is unprotected from precipitation
then moisture must be prevented from entering between the Doorphone and wall
surface. Gaskets are supplied for both flush and wall mount installations. No
gasket is required between the Doorphone and surface mount bracket.
For Surface Mounting, first verify the correct orientation of the gasket, thread the
wires through the center hole, then through the surface mount bracket and fasten
the surface mount bracket at the desired location on the wall. Discard the flush
mount gasket.
For Flush Mounting (into an electrical box embedded in the wall), discard the
surface mounting gasket and the surface mount bracket. Slide the flush mounting
gasket onto the main housing assembly.
Wall
Face
Plate
Main
Housing
Assembly
Figure 5 – Flush MountFigure 4 – Surface Mount
Surface Mount
Gasket
Surface Mount
Bracket
Flush Mount
Gasket
Face
Plate
Main
Housing
Assembly

Norstar Doorphone Installation Guide
10
Installation
Step 3: Wire and Mount the Doorphone (cont’d)
4. Run standard 3-pair cable from the KSU to the Doorphone location. Use one pair
to connect the "KSU" terminals of the Doorphone to a vacant station port of the
KSU. The second pair can be used to connect an optional DOC, leaving an
available spare pair.
All Doorphone connections are polarity insensitive. Strip wires 6 mm ( 1/4")
before inserting them in the terminal block and tightening.
5. When the surface mount bracket is used, secure the wiring with a cable tie
through the round hole in the rear of the bracket as a strain relief. Fasten the
main housing assembly to the surface mount bracket or electrical box (customer
supplied), then fasten the faceplate to the main housing assembly.
Figure 3 – Doorphone TCM Connector Screw Terminals
KSU SAPS DOC

Norstar Doorphone Installation Guide
11
Installation
Step 4: Program Doorphone
Once you have finished programming Norstar Station Port parameters and
connecting the Doorphone, you must specify parameters for the Doorphone's Chime
Type, Volume and, if applicable, Door Opening Capabilities.
Note: It may take up to four minutes for the Doorphone to initialize. The Doorphone
will not initialize or allow programming during an active **CONFIG session. Once
initialization is complete, from a Norstar M7310 or M7324 telephone:
1. Press
ƒ
·
•
›
.
The display shows:
Please wait
momentarily then
Doorphone codes
SHOW QUIT
2. Press
SHOW
.
The display shows:
F9XX
NEXT ADMIN DONE

Norstar Doorphone Installation Guide
12
Installation
Step 4: Program Doorphone (cont’d)
3. Press
ADMIN
.
The display shows the intercom number of Doorphone 1:
DN = XX
OK
Note: The
“
XX
”
represents a
DN
which may be up to seven digits in length. The
NEXT
display button will be presented if more than one Doorphone is installed. If the
Doorphone is not connected or fails, the display shows:
F9XX: inactive
NEXT REMOVE
Use the
REMOVE
display button to remove
F9XX
from the system’s memory
if a Doorphone is permanently removed.

Norstar Doorphone Installation Guide
13
Installation
Step 4: Program Doorphone (cont’d)
4. Press
OK
.
The display shows:
Volume: medium
CHANGE OK
5. Press
OK
to accept the Volume level or press
CHANGE
to select low or high
then
OK
.
The display shows:
Call DN: 21
CHANGE OK
6. Press
OK
to select the default
DN
or press
CHANGE
to enter another
telephone’s
DN
. This will be the telephone which rings when the Doorphone’s
Call button is pressed .
The display shows:
Rings: 5
CHANGE OK
Note: To program the Doorphone to ring several telephones (for example:
telephones 21, 22 and 23):
1. Select an unequipped station port DN (for example: DN 36) as the Call DN in
step 6 above.
2. Enter **CONFIG programming. Navigate to
A.Configuration
,
2. Line Access
for telephone 21. Add an Answer DN for DN 36.

Norstar Doorphone Installation Guide
14
Installation
Step 4: Program Doorphone (cont’d)
3. Repeat step 2 for telephones 22 and 23.
When the Doorphone Call button is pressed, telephones 21, 22 and 23 will ring
because they have a ringing Answer DN for DN 36.
4. Navigate to
B.General admin
,
2. Names
for telephone 36. Change the name
of telephone 36 to “DOOR”. Now change the name of the Doorphone’s DN to
“FRONT”.
Telephones 21, 22 and 23 will display
FRONT>DOOR
when the Doorphone’s Call
button is pressed.
Refer to the Norstar Installer Guide for more details.
7. Press
OK
to accept the number of rings before page chimes are presented, or
press
CHANGE
to select the number of rings. When
none
is selected, the Door-
phone will not ring any telephones when the Call button is pressed.
The display shows:
Page zone: 3
CHANGE OK
8. Press
OK
to accept page zone 3 for chimes presentation, or press
CHANGE
to
select Zone 1, 2 or none. If none is selected, no page chimes will be presented
after ringing the
Call DN
telephone.

Norstar Doorphone Installation Guide
15
Installation
Step 4: Program Doorphone (cont’d)
Note: For a special application where no alerting capability is desired from the
Doorphone, select:
Rings: none
CHANGE OK
and
Page zone: none
CHANGE OK
The display shows:
Chime type: 1
CHANGE OK
9. Press
OK
to accept the Chime type or press
CHANGE
to select 2, 3,
4, or none, then
OK
.
The display shows:
Opener type:none
CHANGE OK
10.Press
OK
if no door opening capabilities are required for this application. Refer
to the next page if door opening capabilities are required.
11.Press
DONE
if no other Doorphones need to be programmed.
12.Press
QUIT
or
®
to end this session. Pressing
®
at any time during the
programming session will save any changes before quitting.

Norstar Doorphone Installation Guide
16
Installation
Step 4: Program Doorphone (cont’d)
Door Opening Control
Two options are available for convenient door opening control, both requiring
optional equipment:
• External Relay Module (ERM)
• Door Opening Controller (DOC)
Note: The ERM and DOC provide convenient control of locked mechanisms but are
not intended for sole premise security. In high security environments, backup
systems should be used for added protection. Power failure, device failure, wiring
faults and unauthorized equipment access can all contribute to a failed locked or
unlocked situation. Refer to the installation documents for the relevant equipment
option.
The ERM connects to the KSU’s external page port contacts to provide high current
switching capability. Choose the DOC if external paging is to be used on the system.
Note: When an ERM is installed, invoking an external page (
ƒ
fl
¤
) from
any station will activate the release mechanism.
The DOC screw terminals are connected to the Doorphone using one pair of wire.
The DOC receives data from the Doorphone and must be dip-switched for proper
operation.