ii HD272 Installation Instructions HD272 Installation Instructions iii
BEFORE YOU BEGIN TO INSTALL YOUR AUTOMATIC GATE OPERATOR:
Watch the enclosed video and read these instructions carefully and completely to become
familiar with all parts and installation steps. The video is only designed as an overview of the
installation procedure. You must read the installation manual for detailed instructions on gate
operator safety and proper use of the gate operator.
NOTE: Substitute a Pin Lock for the clevis pin on the front mount
of the gate operator to prevent unauthorized removal of the operator
from the gate (see accessory pages in back of this book).
Please Read This First!
Thank you for purchasing a Mighty Mule Gate
Operator—the "do-it-yourself" automatic gate
operator! When correctly installed and properly used,
your Mighty Mule Gate Operator will give you many
years of reliable service. Please read the following
information and watch the enclosed video to ensure
you have the correct system for your particular
needs. Furthermore, this manual and the DVD will
enable you to properly install your Mighty Mule Gate
Operator.
The HD272 Operator is designed for installation on
a pull-to-open dual leaf gates (gates that open into
the property). By purchasing the accessory brackets,
the Mighty Mule Gate Operator can accommodate a
push-to-open dual leaf gates (gates that open out from
the property). The gate must not exceed 12 feet in
length and weigh more than 300 pounds (please see
Technical Specications on page 1). The Mighty Mule
Gate Operator can be used on vinyl, aluminum, chain
link, farm tube, and wrought iron gates. Use on solid
surface gates is not recommended. Solid surface gates
have a high resistance to the wind. If the wind is strong
enough, the operator will obstruct and stop, and may
damage the opener.
The Mighty Mule Gate Operator accommodates
extra transmitters, digital keypads, solar panels,
push buttons, automatic gate locks, and other access
control products. These optional accessories (see the
Mighty Mule Accessory Catalog) are available at most
stores. Your store should be able to special order any
accessory not in stock. If your store cannot special
order accessories, please call the Mighty Mule Sales
Department (800-543-GATE).
The Mighty Mule Gate Operator features Dual Sense
Technology™. This feature makes the gate stop and
reverse direction when it comes in contact with an
obstruction. This is factory set to the most sensitive
setting and must be adjusted during installation.
The Mighty Mule Gate Operator also has an adjustable
auto-close feature. After the gate reaches the fully
open position, it can be set to remain open up to 120
seconds before automatically closing. Pressing the
transmitter button at any time after the gate opens fully
will cause it to close immediately. OFF is the factory
setting; meaning the gate will stay open until you press
the transmitter (or keypad, etc.) again.
Go to www.mightymule.com or call (800) 543-4283
to nd a retailer near you. For information about our
professional line of gate operators and accessories,
visit www.linearproaccess.com.
CAUTION
The gate will move freely and uncontrolled when the gate operator is removed from the gate. ONLY disconnect
the operator when the control box power switch is OFF and the gate is NOT moving.
Because automatic gate operators produce high levels
of force, consumers need to know the potential hazards
associated with improperly designed, installed, and
maintained automated gate operator systems. Keep in
mind that the gate operator is just one component
of the total gate operating system. Each component
must work in unison to provide the end user with
convenience, security, and safety.
This manual contains various safety precautions and
warnings for the installer and end user. Because there
are many possible applications of the gate operator,
the safety precautions and warnings contained in
Disconnecting the Operator
1. Turn control box power switch OFF.
2. Remove hairpin clip, clevis pin, and bushing from either the
front or rear mounting point.
3. Remove the operator from the mount.
The gate can be opened and closed manually when the operator is
disconnected.
this manual cannot be completely exhaustive in
nature. They do, however, provide an overview of
the safe design, installation, and use of this product.
CAREFULLY READ AND FOLLOW ALL
SAFETY PRECAUTIONS, WARNINGS, AND
INSTALLATION INSTRUCTIONS TO ENSURE
THE SAFE SYSTEM DESIGN, INSTALLATION,
AND USE OF THIS PRODUCT.
Warnings in this manual are identied with
this warning symbol. The symbol identies
conditions that can result in damage to the operator or
its components, serious injury, or death.
Manually Opening and Closing Gate
Because Mighty Mule automatic gate operators are only part of the total gate operating system, it is the
responsibility of the installer and end user to ensure that the total system is safe for its intended use.
Important Safety Information
Clevis Pin
Hairpin Clip
Gate Bracket
Front Mount