GENERATOR FEATURES
Reference 1 - Air Cleaner. Refer to your Kohler
enginemanual forair cleaner care.
Reference 2 - Circuit Breakers. This portable
single phase generator has 1 - 60 amp (A) thermal
magnetic 2 pole breaker, 1 - 30 amp (A) thermal
magnetic2 polebreaker 1 - 30 amp (A)push to reset
circuitbreaker, and 2 - 20 amp(A) push to reset circuit
breakers. Circuit breakers protect against electrical
overloads.
Reference 3 - 120/240V Receptacle. This
receptacle is a 120/240V 60A NEMA 14-60R
receptacle. This receptacle accepts a NEMA plug
number 14-60P, which is supplied with the generator.
Use this receptacle if installing a transfer switch.
Compatible with Gentran transfer switch, item
#164117.
Reference 4 - 120/240V Twistlock Receptacle.
This twistlock is a 120/240V 30A NEMA L14-30R
receptacle. This receptacle accepts a NEMA plug
numberL14-30P, which issupplied with thegenerator.
Reference 5 - 120V Twistlock Receptacle. This
twistlock is a 120V 30A NEMA L5-30R receptacle.
Thisreceptacleacceptsa NEMAplugnumber L5-30P,
whichissuppliedwith the generator.
Reference 6 - 120V Receptacle. The generator
hasa control panelwith two duplex(two receptaclesin
a commonhousing) receptacles. Each duplexis a 120
volt(V) 20 amp(A) straight blade receptacle, National
Electrical Manufacturer’s Association (NEMA) number
5-20R. This receptacle accepts NEMA plug numbers
5-15Pand 5-20P. Each duplex is capable of drawing
20Aat120V.
ALWAYS use grounded male plugs. The neutral
line of the generator is mechanically grounded to the
frame. Matching NEMA male plugs must always be
used.
WARNINGContact a licensed electrician
to wire electrical plugs and/or cordsets. Improper
wiring could resultinafireor electrical shock.
Reference 7 - Oil Drain Valve. Refer to your
Kohler engine manual for oil change
recommendations.
Reference 8 - Vibration Isolation Mounts. The
engine and generator head are mounted on rubber
cylinders that absorb most of the engine vibration.
Thisfeatureeliminatesthe tendencyofthe machine to
“walk” which is common in engine powered equipment.
Reference 9 - Starting/Stopping Instructions.
Reference 10 - Wheel Kit. Heavy duty wheel kit
(Item #165919).
Reference 11 - 10.0 Gallon Gas Tank. Large
tank allows for extended run capabilities. Always
allow room for gasolineexpansion bynot filling the gas
tankcompletely full.
Reference 12 - Engine Key. The engine key
switch is located on the front of the engine. Always
locate this switch and be familiar with its location
before operating thegenerator.
Reference 13 - Choke Lever. Used during cold
starts. Refer to the starting/stopping instructions and
theKohler Command 25 engine manual for usage.
Reference 14 -Muffler andSparkArrestor.
Reference 15 - Oil Filter. Kohler oil filter number
12-050-01 or equivalent.
Reference 16 - Battery Box and Battery.
Battery isshipped withoutelectrolyte. Fill each battery
cell to the fill line with locally purchased electrolyte
(sulfuricacid and water).
WARNING Sulfuric acid is a corrosive
poison. Avoid contact with skin, eyesor clothing.
Reference 17 - Gas Line Valve. The generator
tank has an ON-OFF valve mounted underneath the
tank. Always keep this valve closed when the
generator isnotin use.
Reference 18 - Generator Head. The electricity
producing partof thegenerator.
Reference 19 - Gas Drain Valve. The generator
isequipped withauniquefeature. Agasdrain valve is
installed to drain gasoline from the tank without
disconnecting the gas line feeding the engine. This
valve is intended to be used to drain gas prior to
extended periodsofnon use. It is recommended that
if theperiod of non use islonger than 30 days, the gas
should be drained, and the engine run until all the gas
is evacuated from the carburetor. ALWAYS make
sure thisvalveisclosed prior tofilling the gastank.
Reference 20 - Gas Capwith Gauge. The gas
cap is extra large, creating a large hole for refilling and
a comfortable grip. You can always monitor the fuel
level without removing the cap by using the fuel level
indicator builtintothe gascap.
Low Oil Shutdown. The Kohler engine is
protected against damage resulting from low oil level.
As the oil falls below the safe level, the engine
automatically shutsoff (the engine stop switch remains
in the on position). The engine will not start until the
oil isrefilled to above the safelevel.
INTRODUCTION
Before starting your generator, thoroughly study
the instructions and cautions in this manual to assure
you are fully acquainted with the operation of all
components of this generator. Proper preparation,
operation and maintenance will result in operator
safety, best performanceand longlifeofthegenerator.
For detailed engine operation andmaintenancealways
refer to the Kohler engine owner’s manual furnished
with the generator.
North Star is constantly improving its products.
The specifications outlined herein are subject to
change without prior notice or obligation. The
purchaser and/or user assumes liability of any
modification and/or alterations on this equipment from
original design and manufacture.
Before using, the user shall determine the
suitability of this product for its intended use and
assumesliabilitytherein.