nuair Lumina User manual

H/ERV
TERMINAL BLOCK
NAV-561
G
GND
A
A BUS
B
B BUS
12
+12V
Select a Mode of Operation
PRESS THE MODE BUTTON AND THE CURRENT MODE ICON AND MODE NUMBER (00-06) WILL FLASH.USE THE ARROW
BUTTONS TO SCROLL UP AND DOWN THE NUMBERED MENU CHOICES. TO INITIATE A DESIRED MODE, PRESS THE MODE
BUTTON ONCE MORE, OR SIMPLY WAIT 4 SECONDS AND THE MODE WILL AUTOMATICALLY ACTIVATE.
Important: Please read before installation.
1. LUMINA (NAV-561) IS COMPATIBLE WITH ANY NU-AIR H/ERV WHICH FEATURES AN ES SERIES CIRCUIT BOARD, RESIDENTIAL OR COMMERCIAL. THE ES SERIES
CIRCUIT BOARD IS EASILY IDENTIFIED BY THE PRESENCE OF ONE 4-WIRE AND ONE 10-WIRE REMOVABLE TERMINAL BLOCK USED FOR CONTROLS WIRING.
2. FOR UNITS WITHOUT A RECIRCULATION DAMPER, TURN OFF RECIRCULATION FUNCTIONS IN CUSTOM SETTINGS.
3. COMPATIBLE NU-AIR ACCESSORY CONTROLS: WIN-20 (20-MINUTE TIMER), ES-T1 (20/40/60-MINUTE TIMER) ONLY.
4. FOR RETROFIT APPLICATIONS: PLEASE REMOVE THE FOLLOWING ES CONTROLS: ES-M1, ES-M2, ES-M3, ES-M4, ES-DVC AS THEY ARE NOW REDUNDANT. USE
ONLY ONE (1) NAV-561 PER INSTALLATION.
5. ROUTE CONTROL WIRING ACCORDING TO LOCAL BUILDING CODES.
YOUR NAV-561 KIT INCLUDES: 1 WALL CONTROL WITH INSTALLATION/USER GUIDE AND 2 WALL-BOX MOUNTING SCREWS.
Lumina Wall Control Installation and User Guide (p/n NAV-561)
Version 1.5, November 2020
Mounting
MOUNT IN A CENTRAL LOCATION WITHIN THE BUILDING.
FITS A STANDARD 2X3” (NOMINAL) ELECTRICAL WALL BOX (NOT INCLUDED).
DRYWALL ANCHORS (NOT INCLUDED) MAY BE USED WHERE A WALL BOX IS NOT AVAILABLE.
Wiring
USING A 2 MM FLAT SCREWDRIVER AND 4-CONDUCTOR WIRE, CONNECT THE H/ERV
12 VDC TERMINAL BLOCK TO THE CORRESPONDING NAV-561 TERMINALS.
POWER. TURNS THE VENTILATOR ON/OFF.
MODE. USE THIS BUTTON TO ENTER THE MODE SELECTION MENU AND TO ACTIVATE A CHOSEN MODE OF
OPERATION.
TIMER. USE THIS BUTTON TO ACTIVATE THE VENTILATOR INTO HIGH SPEED FOR 20, 40 OR 60 MINUTES. THE TIMER
BUTTON CAN ALSO BE USED TO TURN OFF THE HIGH SPEED TIMER FUNCTION.
DOWN ARROW. USE THIS BUTTON TO DECREASE DESIRED HUMIDITY SETTING, OR TO SCROLL THROUGH
MODE/MENU OPTIONS.
UP ARROW. USE THIS BUTTON TO INCREASE DESIRED HUMIDITY SETTING, OR TO SCROLL THROUGH
MODE/MENU OPTIONS.
Use
BACKLIGHT: FIRST BUTTON PRESSED WILL TURN ON THE BACKLIGHT. THE BACKLIGHT WILL REMAIN ILLUMINATED FOR 10 SECONDS.

Select a Humidity Setting
PRESS THE UP OR DOWN ARROW KEY UNTIL THE PRESENT HUMIDITY SETTING AND % SYMBOL ARE FLASHING. USE THE UP/DOWN
ARROW BUTTONS TO ADJUST HUMIDITY SETTING IN 5% INCREMENTS. AFTER 4 SECONDS OF NO BUTTON ACTIVITY, SELECTED
HUMIDITY SETTING (SETPOINT) WILL BE PROGRAMMED.THE CURRENT AMBIENT HUMIDITY WILL THEN BE DISPLAYED.
WHEN AMBIENT HUMIDITY EXCEEDS THE CHOSEN SETPOINT A WATER DROP ICON WILL APPEAR AND THE VENTILATOR WILL
OPERATE IN HIGH SPEED UNTIL THE HUMIDITY LEVEL DROPS BELOW SETPOINT. AVAILABLE HUMIDITY SETTING RANGE: 20-80%.
TO TURN OFF HUMIDITY-ACTIVATED HIGH SPEED IF DESIRED, USE THE ARROW KEYS TO TOGGLE THE HUMIDITY SETPOINT TO
ONE CLICK ABOVE 80% OR ONE CLICK BELOW 20%. ALSO USE ARROW KEYS TO REACTIVATE HUMIDITY CONTOL.
00: OFF. VENTILATOR IS OFF, BUT THE CONTROL ITSELF IS ON AND WILL DISPLAY AMBIENT HUMIDITY
LEVEL.
01: STANDBY. VENTILATOR IS IDLE. DURING THIS MODE, A STATIC PAUSE ICON WILL DISPLAY. DURING STANDBY MODE THE VENTILATOR WILL
TEMPORARILY SWITCH TO HIGH SPEED ON DEMAND FROM THE LUMINA HUMIDITY SENSOR OR A TIMER.
02: LOW SPEED. VENTILATOR RUNS IN LOW SPEED CONTINUOUSLY. DURING THIS MODE, AN ANIMATED 3-BLADE FAN WILL DISPLAY. DURING
LOW SPEED MODE THE VENTILATOR WILL TEMPORARILY SWITCH TO HIGH SPEED ON DEMAND FROM THE LUMINA HUMIDITY SENSOR OR A TIMER.
03: HIGH SPEED. VENTILATOR RUNS IN HIGH SPEED CONTINUOUSLY. DURING THIS MODE, AN ANIMATED 6-BLADE FAN WILL DISPLAY. VENTILATOR
WILL REMAIN IN HIGH SPEED ON DEMAND FROM THE LUMINA HUMIDITY SENSOR OR A TIMER AND CONTINUE IN HIGH SPEED AFTER THE
HUMIDITY/TIMER DEMAND IS MET.
04: 20 LO/40 STANDBY. VENTILATOR CYCLES CONTINUOUSLY BETWEEN 20 MINUTES OF LOW SPEED OPERATION AND 40 MINUTES OF STANDBY
OPERATION. DURING LOW SPEED CYCLE, THE FAN 3-BLADE FAN ICON WILL ANIMATE AND THE PAUSE SYMBOL WILL FLASH TWICE EVERY 5 SECONDS.
DURING THE STANDBY CYCLE, THE PAUSE ICON WILL BE STATIC AND THE FAN ICON WILL FLASH TWICE EVERY 5 SECONDS. DURING 20 LO/40 STANDBY
MODE THE VENTILATOR WILL TEMPORARILY SWITCH TO HIGH SPEED ON DEMAND FROM THE LUMINA HUMIDITY SENSOR OR A TIMER.
05: RECIRCULATION. VENTILATOR CONTINUOUSLY RECIRCULATES AIR WITHIN THE HOME AND DOES NOT BRING IN AIR FROM OUTSIDE, I.E. AIR
EXCHANGE DOES NOT OCCUR. DURING THIS MODE AN ANIMATED CYCLING ARROW WILL DISPLAY. DURING RECIRCULATION MODE THE
VENTILATOR WILL TEMPORARILY SWITCH TO HIGH SPEED ON DEMAND FROM THE LUMINA HUMIDITY SENSOR OR AN EXTERNAL TIMER.
Recirculation Modes
NOTE TO INSTALLER: FOR MODELS OF VENTILATOR THAT DO NOT HAVE RECIRCULATION COMPONENTS, TURN OFF RECIRCULATION FUNCTIONS THE
OPTIONS MENU (SEE CUSTOM SETTINGS).
06: 20 LO/40 RECIRCULATION. VENTILATOR CYCLES CONTINUOUSLY BETWEEN 20 MINUTES OF LOW SPEED OPERATION AND 40 MINUTES OF
RECIRCULATION OPERATION. DURING THE LOW SPEED CYCLE, THE FAN WILL ANIMATE AND THE RECIRCULATION RING WILL FLASH TWICE
EVERY 5 SECONDS. DURING THE RECIRCULATION CYCLE, THE RECIRCULATION ARROW WILL ANIMATE AND THE FAN ICON WILL FLASH TWICE
EVERY 5 SECONDS. DURING 20 LO/40 RECIRCULATION MODE THE VENTILATOR WILL TEMPORARILY SWITCH TO HIGH SPEED ON DEMAND
FROM THE LUMINA HUMIDITY SENSOR OR A TIMER.
OPERATING HINT. GENERALLY, A HUMIDITY SETTING OF 40-60% IS DESIRABLE. WHILE YOUR VENTILATOR IS NOT A DEHUMIDIFIER, VENTILATION CAN
HAVE THE EFFECT OF REDUCING INDOOR HUMIDITY WHEN EXCHANGING MOISTURE-LADEN AIR FROM THE INTERIOR SPACE WITH LESS HUMID, FRESH
AIR FROM OUTSIDE, ESPECIALLY DURING COLDER MONTHS.
Modes

Using External Timers (ES-T1 Timer and/or Win-20 Timer)
THE ES-T1 AND WIN-20 STYLE TIMERS ARE COMPATIBLE WITH YOUR LUMINA CONTROL, HOWEVER, THE LUMINA WILL NOT INDICATE THAT THESE EXTERNAL TIMERS
ARE ACTIVE (I.E. IT WILL CONTINUE TO DISPLAY PRESENT MODE OF OPERATION ONLY). YOU CAN CHANGE THE DESIRED MODE OF OPERATION DURING A TIMER CYCLE;
IT WILL COMMENCE AFTER THE TIMER CYCLE HAS EXPIRED.
Maintenance Indicator/Resetting Maintenance Clock
YOUR LUMINA CONTROL HAS A MAINTENANCE RUN CLOCK (IT ONLY COUNTS TIME WHEN THE VENTILATOR IS TURNED ON). FACTORY
DEFAULT FOR THE MAINTENANCE CLOCK IS 3 MONTHS, AT WHICH TIME A WRENCH ICON WILL APPEAR IN THE UPPER RIGHT OF THE LCD
SCREEN AND A YELLOW LED TURN ON BELOW THE SCREEN. THIS INDICATES THAT IT IS TIME TO CHECK YOUR VENTILATOR TO SEE IF IT
NEEDS CLEANING AND IF YOUR FILTERS NEED TO BE CLEANED OR REPLACED. PRESS AND HOLD THE POWER BUTTON FOR 5 SECONDS TO
RESET THE MAINTENANCE CLOCK. NAV-561B (2017-) units feature a RED LED which will light after 3 months if the initial service
reminder is not turned off.
Using the High Speed Timer
FOR TIMED HIGH SPEED OPERATION, PRESS THE HOURGLASS BUTTON ONCE FOR 20 MINUTES, TWICE FOR 40 MINUTES, OR THREE
TIMES FOR 60 MINUTES. AFTER 3 SECONDS THE HIGH SPEED CYCLE WILL BEGIN. AS EACH 20 MINUTE CYCLE EXPIRES, ONE HOURGLASS
ICON WILL DISAPPEAR FROM RIGHT TO LEFT. YOU CAN TURN OFF THE TIMER CYCLE BY PRESSING THE HOUR GLASS BUTTON UNTIL ALL
THE HOURGLASS ICONS DISAPPEAR.
YOU CAN STILL VIEW OR CHANGE OPERATION MODES DURING TIMER FUNCTION IF DESIRED. CHOSEN MODE WILL
RESUME/COMMENCE AFTER THE TIMER FUNCTION STARTS.
Operation Following a Power Interruption
IF THE ELECTRICAL SERVICE TO THE VENTILATOR IS INTERRUPTED, THE MODE OF OPERATION ACTIVE IN THE WALL CONTROL AT THE TIME OF THE INTERRUPTION WILL
RESUME WHEN THE ELECTRICAL SERVICE TO THE VENTILATOR RESUMES. ANY CUSTOM SETTINGS WILL HAVE BEEN SAVED.
TO OPEN CUSTOM SETTINGS MENU, SIMULTANEOUSLY PRESS AND HOLD THE UP AND DOWN ARROW BUTTONS FOR 15 SECONDS (THE BACKLIGHT
TURNS ON AFTER 10 SECONDS). USE THE ARROW BUTTONS TO NAVIGATE CHOICES FOR EACH SETTING. PRESS THE MODE BUTTON TO PRESERVE
FACTORY SETTINGS, INITIATE ANY CHANGE, AND MOVE TO THE NEXT MENU ITEM. AFTER 5 SECONDS OF NO BUTTON ACTIVITY, CURRENT SETTINGS
WILL BE WRITTEN AND THE CONTROL WILL RESUME REGULAR OPERATION.
Custom Settings
THE NAV-561 ALLOWS ADJUSTMENTS TO CUSTOMIZE ITS USE. THESE CHANGES CAN BE DONE/UNDONE AN INFINITE NUMBER OF TIMES. IT IS RECOMMENDED THAT
ONLY A QUALIFIED TECHNICIAN MAKES THESE ADJUSTMENTS AS THEY CAN AFFECT THE NATURE OF THE VENTILATOR’S PERFORMANCE. THE CUSTOMIZABLE FEATURES
WILL APPEAR IN SEQUENCE AND INCLUDE:
1. ADJUSTING THE RUN TIME OF THE MAINTENANCE CLOCK
2. CALIBRATING THE HUMIDITY SENSOR
3. TURNING OFF/ON RECIRCULATION FUNCTIONS.
Adjustment Setting 2: Calibrating the Humidity Sensor
IF CALIBRATION IS NOT DESIRED, SIMPLY PRESS THE MODE BUTTON. IF CALIBRATION IS DESIRED, USE THE UP AND DOWN ARROW KEYS TO
CALIBRATE THE HUMIDITY SENSOR IN 5% INCREMENTS. TO PROGRAM ANY CHANGES, PRESS THE MODE BUTTON. MENU ADVANCES TO
RECIRCULATION.
Adjustment Setting 3: Turn OFF/ON Recirculation Functions (default is ON)
AN ANIMATED RECIRCULATING ARROW INDICATES THAT RECIRCULATION IS ENABLED. USE THE UP AND DOWN ARROW KEYS TO TURN OFF
RECIRCULATION (STATIC ARROW) OR ON (ANIMATED ARROW). TO PROGRAM ANY CHANGES, PRESS THE MODE BUTTON. CUSTOM MENU CLOSES.
NOTE: IF RECIRCULATION IS NOT TURNED OFF FOR VENTILATORS NOT EQUIPPED FOR RECIRCULATION, THE VENTILATOR WOULD OPERATE IN LOW
SPEED WHEN RECIRCULATION MODE IS SELECTED.
Adjustment Setting 1: Run Time Maintenance Clock
MAINTENANCE CLOCK FACTORY SETTING: 3 MONTHS. TO KEEP FACTORY SETTING, PRESS THE MODE BUTTON OR USE THE UP AND DOWN ARROW
BUTTONS TO CHANGE 1-12 MONTHS. ONCE ANY DESIRED CHANGE IS MADE (IF ANY), PRESS THE MODE BUTTON. MENU ADVANCES TO HUMIDITY
SENSOR.
This manual suits for next models
1
Table of contents
Popular Controllers manuals by other brands

LU-VE
LU-VE R2PR instructions

HighPoint
HighPoint R1000 Series Quick installation guide

Trane
Trane Tracer AH541 Installation sheet

National Instruments Corporation
National Instruments Corporation FieldPoint cFP-20 Series quick start guide

Unitronics
Unitronics Vision V120 user guide

Miller
Miller RHC-TP owner's manual