WIRING OPENING RELEASE SLOT
INSTALLATION
WARNING:To reduce the risk of fire, do not store or
use gasoline or other flammable vapors and liquids
in the vicinity of the heater.
CAUTION: High temperature, risk of fire, keep
electrical cords, drapery, furnishings, and other
combustibles at least 3 feet (0.9 m) from the front of
the heater and away from the side and rear.
STEP 8 - MODEL 658 ONLY
8. For best results, choose a location which allows
fan to be vented outside with the shortest possible
duct run and the fewest number of elbows.
9. Position unit between joists and extend mounting
brackets. Position brackets such that bottom edge
of housing will be flush with finished ceiling. Mark
the top of keyhole slot on all four mounting brackets.
(FIG. 6)
10. Remove unit temporarily, and pound nails partially
into joists at all four marked locations. (FIG. 7)
11. Hang unit from nails and use embossed measuring
guides to check if unit will be flush with finished
ceiling. Pound nails tight. For wide joist centers:
A #8 x 3/8 self-tapping screw can be used to join
extended brackets together and create a rigid mount.
To ensure a noise-free mount, crimp the bracket
channels tightly around mounting brackets. (FIG. 8)
STEP 12 - MODEL 658 ONLY
12. Snap the damper/duct connector onto housing.
Make sure that tabs on the connector lock in
housing slots. (Top of damper/duct connector
will be flush with top of housing.) (FIG. 9)
NOTE: Make sure damper flap is in place inside
of duct connector. If it is not: Squeeze top and
bottom of connector to snap flap back into place.
(FIG. 10)
Installation work and electrical wiring must be
done by a qualified person(s) in accordance with
all applicable codes and standards, including fire-
rated construction codes and standards.
13. Wire unit according to appropriate diagram. (FIG.11
or FIG.12)
NOTE
If the switch has not been wired properly and wires
need to be moved:
1. Each wire opening has a release slot.
2. Push a small nail or screwdriver into release slot
while gently removing wire.
3. DO NOT pull any wire out of the switch without
using the release slot. The switch may be dam-
aged.
14. Replace heater assembly removed in STEP 3 and
plug it into RED receptacle. Direct wires away from
blower inlet.
FIG. 6
FIG. 7
FIG. 8
FIG. 9
EMBOSSED
MEASURING
GUIDES
FLUSH
NIVEL
FIG. 10