manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. NuTone
  6. •
  7. Fan
  8. •
  9. NuTone RF-79RP User manual

NuTone RF-79RP User manual

Other NuTone Fan manuals

NuTone 8310 User manual

NuTone

NuTone 8310 User manual

NuTone PFKB52 Series User manual

NuTone

NuTone PFKB52 Series User manual

NuTone QTREN070C User manual

NuTone

NuTone QTREN070C User manual

NuTone ZN80L User manual

NuTone

NuTone ZN80L User manual

NuTone 656 User manual

NuTone

NuTone 656 User manual

NuTone 770F User manual

NuTone

NuTone 770F User manual

NuTone QT150 User manual

NuTone

NuTone QT150 User manual

NuTone QTXEN050 User manual

NuTone

NuTone QTXEN050 User manual

NuTone ULTRA SILENT QTRN Series User manual

NuTone

NuTone ULTRA SILENT QTRN Series User manual

NuTone 6714 User manual

NuTone

NuTone 6714 User manual

NuTone VENT-A-LITE 668RP User manual

NuTone

NuTone VENT-A-LITE 668RP User manual

NuTone PFOB-52 User manual

NuTone

NuTone PFOB-52 User manual

NuTone 765hl User manual

NuTone

NuTone 765hl User manual

NuTone EZ80NC User manual

NuTone

NuTone EZ80NC User manual

NuTone ULTRA Pro RB80L User manual

NuTone

NuTone ULTRA Pro RB80L User manual

NuTone Heat-A-Vent 605RP Guide

NuTone

NuTone Heat-A-Vent 605RP Guide

NuTone ZN80 User manual

NuTone

NuTone ZN80 User manual

NuTone QTREN080 Series User manual

NuTone

NuTone QTREN080 Series User manual

NuTone 8814R User manual

NuTone

NuTone 8814R User manual

NuTone ZN110HL  sheet User manual

NuTone

NuTone ZN110HL sheet User manual

NuTone 9960 User manual

NuTone

NuTone 9960 User manual

NuTone 754RBNT User manual

NuTone

NuTone 754RBNT User manual

NuTone LS80LF User manual

NuTone

NuTone LS80LF User manual

NuTone HEAT-A-VENT 9905 User manual

NuTone

NuTone HEAT-A-VENT 9905 User manual

Popular Fan manuals by other brands

Minka Group minkaAire Wave F843 instruction manual

Minka Group

Minka Group minkaAire Wave F843 instruction manual

Airflow Adroit DV50 instruction manual

Airflow

Airflow Adroit DV50 instruction manual

Vornado 270 Series owner's guide

Vornado

Vornado 270 Series owner's guide

comfort air TH-10D instruction manual

comfort air

comfort air TH-10D instruction manual

Livoo DOM386 instruction manual

Livoo

Livoo DOM386 instruction manual

Holmes BLIZZARD HAOF-90 owner's guide

Holmes

Holmes BLIZZARD HAOF-90 owner's guide

Taurus GRECO 16 ELEGANCE manual

Taurus

Taurus GRECO 16 ELEGANCE manual

Quorum PINNACLE installation instructions

Quorum

Quorum PINNACLE installation instructions

Monte Carlo Fan Company 3DIR58RBD-V1 Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company 3DIR58RBD-V1 Owner's guide and installation manual

Craftmade UH52 installation guide

Craftmade

Craftmade UH52 installation guide

Jocel JVA030658 instruction manual

Jocel

Jocel JVA030658 instruction manual

MIKA MFB1211/GR user manual

MIKA

MIKA MFB1211/GR user manual

Harbor Breeze RLG52NWZ5L manual

Harbor Breeze

Harbor Breeze RLG52NWZ5L manual

Allen + Roth L1405 instruction manual

Allen + Roth

Allen + Roth L1405 instruction manual

ViM KUBAIR F400 ECOWATT Technical manual

ViM

ViM KUBAIR F400 ECOWATT Technical manual

HIDRIA R10R-56LPS-ES50B-04C10 user guide

HIDRIA

HIDRIA R10R-56LPS-ES50B-04C10 user guide

BLAUBERG Ventilatoren CENTRO-M 100 L user manual

BLAUBERG Ventilatoren

BLAUBERG Ventilatoren CENTRO-M 100 L user manual

Triangle Engineering HEAT BUSTER SPL Series owner's manual

Triangle Engineering

Triangle Engineering HEAT BUSTER SPL Series owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Architectural & Engineering Specifications
August 2001
Exterior-Mounted
Power Attic Ventilator
with Automatic Thermostat
MODEL: RF-79RP
DESCRIPTION
•Pulls hot air out of larger attics automatically. Exhausts
moisture and condensation that can cause premature
deterioration of attic insulation, shingles, roof, rafters,
wiring and outside paint.
• Efficient PSC type motor.
•Trim silhouette with 22" diameter by 9" high housing.
•23" square, aluminum, one-piece self-flashing flange and
venturi design provide complete rain seal. Includes
birdguard.
• Polymeric dome is UV protected.
•Automatic thermostat turns the fan on at selected
temperature setting from 60°F to 120°F or, may be
used with a general use On/Off switch for manual control.
•14
1
⁄
2
" diameter roof cutout between rafters. Install on
flat or pitched roof. When used on flat roofs, fan should
be mounted on built-up curb so that unit is raised above
standing water level.
DESIGN FEATURES
Air Delivery: 1400 CFM at .03" S.P.
2000 sq. ft. attic floor area.
Dimensions: 9" high, dome 22" diameter,
23" square flashing plate.
Motor: PSC type, sleeve bearing, thermally
protected (auto-reset with one-shot
fuse backup protector).
Material & Finish: Flashplate is plated steel with brown,
powder coat paint finish. Dome is dark
gray, UV protected, polymeric
material. Bird guard is UV protected
polymeric material.
Fan Blade: 5 Fins, 14" diameter, 4" pitch,
galvanized steel.
Thermostat: Adjustable from 60° to 120°F. Preset
to 110°F.
Electrical Rating: 120V, 60Hz, 3.9A.
ARCHITECT'S SPECIFICATIONS
Attic Cooling Fan shall be Model RF-79RP as
manufactured by NuTone, according to product
specifications listed: 9" high, dome 22" diameter,
flashing 23" square; contains automatic, adjustable
thermostat; 1400 CFM at .03" S.P.
CERTIFIED TEST DATA
Air delivery rating is certified by the Home Ventilating
Institute Division of AMCA, based on testing performed
by an independent third party testing laboratory, in
accordance with HVI standards. This NuTone model
is listed by Underwriters' Laboratories Inc.
Product specifications subject to change without notice.
4820 Red Bank Road, Cincinnati, Ohio 45227
Printed in U.S.A
SELECTION DATA
To determine fan size needed, measure square footage
of attic floor and multiply footage by .70. The result will be
the minimum air delivery required.
INSTALLATION
Mounts on a pitched or flat roof between 16" O.C.
rafters. Roof cutout minimum of 141⁄2" diameter.
IMPORTANT: On a flat roof installation, fan must be
mounted on curb build-up above the waterline. The Outlet
Box containing thermostat attaches to nearest roof rafter .
Thermostat preset at 110°F; calibrated dial settings from
60° to 120°F. May be used with standard on/off toggle
switch for manual control (must be purchased separately.)
Installation Instructions packaged with each unit.
DIMENSIONS
24" DIA.
107⁄8"
23"
23"
22" DIA.
9"