manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. NuTone
  6. •
  7. Intercom System
  8. •
  9. NuTone LA-107 Series User manual

NuTone LA-107 Series User manual

Other NuTone Intercom System manuals

NuTone Communi-Center 2542-B User manual

NuTone

NuTone Communi-Center 2542-B User manual

NuTone LA223WH Manual

NuTone

NuTone LA223WH Manual

NuTone LA227WH User manual

NuTone

NuTone LA227WH User manual

NuTone IM-5000 series User manual

NuTone

NuTone IM-5000 series User manual

NuTone IM-303 Series Operating instructions

NuTone

NuTone IM-303 Series Operating instructions

NuTone IM-3103 User manual

NuTone

NuTone IM-3103 User manual

NuTone LA-174 User manual

NuTone

NuTone LA-174 User manual

NuTone IM-3303 Series Operating instructions

NuTone

NuTone IM-3303 Series Operating instructions

NuTone IM-313 Communicenter User manual

NuTone

NuTone IM-313 Communicenter User manual

NuTone IM-3204 Series User manual

NuTone

NuTone IM-3204 Series User manual

NuTone NM200AL User manual

NuTone

NuTone NM200AL User manual

NuTone 801T User manual

NuTone

NuTone 801T User manual

NuTone IK-25 series Manual

NuTone

NuTone IK-25 series Manual

NuTone IM-3003 Series User manual

NuTone

NuTone IM-3003 Series User manual

NuTone VSUC4RK User manual

NuTone

NuTone VSUC4RK User manual

NuTone LA-204WH Manual

NuTone

NuTone LA-204WH Manual

NuTone IM-323 User manual

NuTone

NuTone IM-323 User manual

NuTone NM100WH User manual

NuTone

NuTone NM100WH User manual

NuTone VSM4RK User manual

NuTone

NuTone VSM4RK User manual

NuTone IM-5006 User manual

NuTone

NuTone IM-5006 User manual

NuTone VSUC4SK User manual

NuTone

NuTone VSUC4SK User manual

NuTone IMA-3303 User manual

NuTone

NuTone IMA-3303 User manual

NuTone VSUC4RK User manual

NuTone

NuTone VSUC4RK User manual

NuTone im-406 User manual

NuTone

NuTone im-406 User manual

Popular Intercom System manuals by other brands

Videx VRDK1 (25H) Technical manual

Videx

Videx VRDK1 (25H) Technical manual

Auta COMPACT VISUALTECH manual

Auta

Auta COMPACT VISUALTECH manual

Aiphone LC-10S instructions

Aiphone

Aiphone LC-10S instructions

Aiphone PD-1 instructions

Aiphone

Aiphone PD-1 instructions

Aiphone JF-DVF-HID-I instructions

Aiphone

Aiphone JF-DVF-HID-I instructions

Comelit 4893M Technical manual

Comelit

Comelit 4893M Technical manual

MGL Avionics V16 manual

MGL Avionics

MGL Avionics V16 manual

SSS Siedle BVI 750-0 Installation & programming

SSS Siedle

SSS Siedle BVI 750-0 Installation & programming

urmet domus AIKO 1716/1 quick start guide

urmet domus

urmet domus AIKO 1716/1 quick start guide

urmet domus IPerVoice 1039 Installation

urmet domus

urmet domus IPerVoice 1039 Installation

Alpha Communications STR QwikBus TT33-2 Installation, programming, and  user's manual

Alpha Communications

Alpha Communications STR QwikBus TT33-2 Installation, programming, and user's manual

Monacor ICM-20H instruction manual

Monacor

Monacor ICM-20H instruction manual

Logenex A202CR Installation & programming

Logenex

Logenex A202CR Installation & programming

Quantum QR5 Installation and programming manual

Quantum

Quantum QR5 Installation and programming manual

EVGA XR1 quick guide

EVGA

EVGA XR1 quick guide

CyberData 011211 series Installation quick reference

CyberData

CyberData 011211 series Installation quick reference

Vidos duo M1021 user manual

Vidos

Vidos duo M1021 user manual

Savant DOR-SMS-00 Deployment guide

Savant

Savant DOR-SMS-00 Deployment guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
Viking Door Chime
MODEL: LA-107 SERIES
• For use with either a transformer or batteries
LOCATION
TRANSFORMER: Mount a 10 or 16-volt transformer to a
conveniently located junction box. Attic location is not
recommended. For best performance, a 16 volt transformer is
recommended.
PUSHBUTTON: The chime is designed for two-note
operation. Select pushbutton locations at front and rear (or side)
doors. Do not use lighted pushbuttons with battery-operated
chime.
NEW INSTALLATION
INSTALLING TRANSFORMER
Disconnect house power until installation is complete. All
wiring must comply with local codes.
1. Use a NuTone transformer (16 volts, 10 watts).
2. Refer to Figure 1. Mont transformer to a conveniently located
junction box. Do not mount transformer in attic.
3. Use approved wire connectors to connect supply wires to
transformer leads: white to white; black to black.
FIGURE 1
FIGURE 2
FIGURE 3
SUPPLY WIRE
REPLACEMENT OR NEW INSTALLATION
USING TRANSFORMER
NEW INSTALLATION USING BATTERIES
FRONT DOOR
PUSHBUTTON
FRONT DOOR PUSHBUTTON
REAR DOOR PUSHBUTTON
120vAC
TRANSFORMER
16 VOLT 10VA OR
10 VOLT 5VA
FOR ONE DOOR
OR TWO DOORS
CHIME BASE
TERMINAL BOARD
TO 120
HOUSE
WIRING
R
T
C
F
R
T
C
F
DO NOT OIL
C - BAT. COMMON
T - TRANSFORMER
F - FRONT DOOR PB
R - REAR DOOR PB
DO NOT OIL
C - BAT. COMMON
T - TRANSFORMER
F - FRONT DOOR PB
R - REAR DOOR PB
REAR DOOR
PUSHBUTTON
FOR ONE DOOR
OR TWO DOORS
CHIME BASE
TERMINAL BOARD
“D” SIZE
BATTERY
“D” SIZE
BATTERY
“D” SIZE
BATTERY
“D” SIZE
BATTERY
WIRES TO
CHIME
CHIME
BASE
MAKE SURE
KEYHOLE
MOUNTING HOLE
IS AT THE TOP
PUSHBUTTON
AND
TRANSFORMER
WIRING FIGURE 4
INSTALLING THE WIRING
1. Use standard bell/chime wire (20 gauge, two-conductor).
2. Run wires as shown in Figure 2 for installation using transformer.
3. Run wires as shown in Figure 3 for installation using batteries.
MOUNTING CHIME BASE
Refer to Figure 4.
1. At chime location, cut a 1" diameter hole (for pushbutton and
transformer wiring) in the wall.
2. Pull wiring through two holes in chime base.
3. Use two provided screws to mount chime base to wall. Make sure
keyhole mounting hole is at top.
WIRING CONNECTIONS
1. Use wire nuts to make connections. Insulate all connections with
electrical tape.
2. INSTALLATION USING TRANSFORMER.
Refer to Figure 2. Connect pushbutton and transformer wires to
terminal screws marked Front, Transformer, and Rear.
3. INSTALLATION USING BATTERIES.
Refer to Figure 3. Connect pushbutton wires to terminal screws
marked Front, Common, and Rear.
WIRING HINTS
1. Carefully fasten wiring to wall studs
and ceiling joists. Avoid short circuits
caused by staples or clops cutting
through the wiring's insulation.
2. Loop wire around terminal screws.
3. When connecting more than one wire
to a single terminal screws, twist the wires together before looping
them around the terminal screw.
4. Make sure all terminal screws are tightened securely.
BATTERY INSTALLATION
1. Install four (4) “D” size batteries as shown in Figure 4.
2. For longer life, alkaline batteries are recommended.
ATTACHING CHIME COVER
1. Place cover over base.
2. Refer to Figure 5. Secure cover by placing mounting tab into slot at
back of base.
CHIME
COVER
CHIME
BASE
MOUNTING TAB
MOUNTING SLOT
FIGURE 5
REPLACEMENT INSTALLATION
1. Turn off house power until installation is complete.
2. Remove cover from existing chime and disconnect wires from
terminal screws. Label all wires (Front, Transformer, Rear) as you
remove them. NOTE: Any additional wires (for example: common
or side) should be individually capped with wire nuts or sealed with
electrical tape and pushed back into the wall cavity. These wires
are not needed.
3. Remove existing chime base from wall.
4. Pull wires through holes in new chime base.
5. Use provided screws to mount base to wall.
6. Connect wires to terminal screws marked Front, Transformer, and
Rear on the chime base.
7. Place chime cover securely over the base.
8. Restore house power to chime.
4820 Red Bank Road, Cincinnati, Ohio 45227
Printed in U.S.A., Rev. 3/01 Part No. 83527
Product specifications subject to change without notice.
One Year Limited Warranty
WARRANTY OWNER: NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period
of one (1) year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one year period, NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES
FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident,
improper maintenance or repair (other than by NuTone), faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty
lasts, so the above limitation may not apply to you.
NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS
WARRANTY. NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH
PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may
not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.
WARRANTY SERVICE: To qualify for warranty service, you must (a) notify NuTone at the address stated below or telephone 1/800-543-8687, (b) give the model
number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present
evidence of the original purchase date.
Date of Installation Builder or Installer
Model No. and Product Description
IF YOU NEED ASSISTANCE OR SERVICE:
For the location of your nearest NuTone Independent Authorized Service Center:
Residents of the contiguous United States Dial Free 1-800-543-8687
Please be prepared to provide:
Product model number • Date and Proof of purchase • The nature of the difficulty
Residents of Alaska or Hawaii should write to: NuTone Inc. Attn: Department of National Field Service, 4820 Red Bank Road, Cincinnati Ohio 45227-1599.
Residents of Canada should write to: Broan-NuTone Canada, 1140 Tristar Drive, Mississauga, Ontario, Canada L5T 1H9.
Rev. 03/2001