NY Wholesale DT608 Series User manual

USER MANUAL
DT-ENG-608-V1 / 201708
• Please read this manual carefully to ensure safe and correct operation.
• Keep this manual well for future reference.
RF CARD
EP608-S12DT608/ID/FE-S8 DT60C-S8
DT608 Series
2 WIRE SYSTEM
Fisheye door station with proximity access control

CONTENTS
PARTS AND FUNCTIONS ..................................................................................... 3
Part Names............................................................................................................. 3
Mounting................................................................................................................. 3
Terminal Description............................................................................................... 4
BASIC FUNCTIONS .............................................................................................. 5
Unlock Operations.................................................................................................. 5
Fisheye Camera ..................................................................................................... 5
External Motion Detection ...................................................................................... 5
SETUP INSTRUCTIONS........................................................................................ 6
Functions Setting Up .............................................................................................. 6
Setting Door Station Address ................................................................................. 7
Setting Door Station Calling Mode ......................................................................... 7
Setting Camera N/P Standard................................................................................ 9
Setting Prompt Voice.............................................................................................. 9
Setting Prompt Voice Volume................................................................................ 10
Setting Unlock Mode ............................................................................................. 10
Setting Unlock Time............................................................................................... 11
Setting Nameplate Illumination Mode.................................................................... 11
Setting Night View LED Illumination Mode............................................................ 12
Setting Ring-back Tone ......................................................................................... 12
Setting Image Display Mode.................................................................................. 13
RAINY_COVER Congure .................................................................................... 14
Registering ID Card............................................................................................... 15
Restore To Default................................................................................................. 17
WIRING ................................................................................................................. 18
Connecting Electric Lock....................................................................................... 18
As The Villa System Door Stations........................................................................ 19
As The Apartment System Door Stations.............................................................. 20
APPENDIX ............................................................................................................ 21
Precautions............................................................................................................ 21
Specication .......................................................................................................... 21
Cables and Requirments....................................................................................... 22

-3-
Part Names
PARTS AND FUNCTIONS
[9]
[10]
[11]
[12]
[8]
[7]
[6]
[5]
[1]
[3]
[4]
[2]
[1] Microphone
[2] UNLOCK indicator
[3] CALL indicator
[4] Call button
[5] Nameplate
[6] Speaker
[7] Night view LED
[8] Camera lens
[9] Rainy cover
[10] Mounting hook
[11] Connection port
[12] External key module
Mounting
1 2 3 4 5
Rainy cover
The distance between
the top of main unit
and rain cover should
be not less than 3mm.
Main unit
≥3mm
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
Rainy cover
Main unit
1. Drill holes in the wall to match the size of screw stoppers, then attach the rainy cover to the
wall.
2. Connect the cable correctly, and attach the main unit to the rainy cover. The distance between
the top of main unit and rain cover should be not less than 3mm.
The installation height is suggested to 145~160cm.

-4-
PARTS AND FUNCTIONS
Lock Control Jumper: To select the lock type.
3P Connect Port: 1. If the external key module is detected online, the port will be
automatically as a communication port;
2. If there is no the external key module, it will check whether the PIR function is enabled. If the
PIR function is enabled, it will be as the detection port of the PIR;
3. If above cases are not activated, GND and PIR can be used as exit button port.
Main Connect Port: To connect the bus line and the electronic locks.
• L1,L2: Connect to the bus line, no polarity.
• PL: External lock power input, connect to the power positive(power +).
• S+: Lock power(+) output.
• S-: Lock power(-) output, connect to the power(-) input of locks(only when using the door
station to power the locks, if using the external power supply for the locks, the S- will not be
connected).
1 2 3
Lock Control Jumper
3P Connect Port
+12V
GND
PIR
L1 L2
PL
S+ S-
Main Connect Port
3. Install the name plate.
4. Attach the front panel to the rainy cover.
5. Use the special screwdriver and the screws to x the panel.
Terminal Description

-5-
BASIC FUNCTIONS
Unlock Operations
Unlocking of ID Card
When the registered user card has been shown to ID card window, the UNLOCK indicator lights
up, the buzzer sounds,and the electric door strike is unlocked.
• If show the authorized user card,the buzzer will sound of beep+,and the UNLOCK indicator
will light up.
• If show the unauthorized user card,the buzzer will sound of beep,beep,beep.
Fisheye Camera
External Motion Detection
Please note that this function requires the
monitor with sheye function to support.
The angle view is 1700,visitors in this angle
view can be seen clearly and can be zoomed
to see individuals up close via indoor monitor
with sheye function.
The door station is equipped with a terminal to
connect external motion detector.
If the external motion detector is connected
to the system,following functions will be effec-
tive:
If detect someone passing by, the door station
can be activated operation to unlock or turn
on light.
Standard
door station angle
DT608
1700door camera angle
(Wide angle view shown)
12V
Motion
detector
GND
PIR
* Please contact with supplier for more details about
detector connection.

-6-
SETUP INSTRUCTIONS
Functions Setting Up
KEY_1
KEY_2
KEY_3
KEY_4
KEY_SET
LED_UNLOCK
LED_CALL
LED_NAME
Main unit
RF CARD
This section explains the settings of each
function, please refer to the following table:
To perform the settings for the function
you want,you should move away the metal
front panel. Please refer to the sketch
map.
Each operation is indicated by the lighting
up of the LED indicator on the unit, and by
the sounding of the buzzer.
Order Setting items Setting range Default value
1 Setting door station address 0~3 0
2Setting door station
calling mode Standard/Group calling mode Standard calling mode
3 Setting camera N/P standard N/P standard P standard
4 Setting prompt voice Max. 9 voices Voice 1
5 Setting prompt voice volume 1~9 6
6 Setting the unlock mode 0:opened/1:closed 0:opened
7 Setting the unlock time 01 to 99 seconds 1 seconds
8Setting the nameplate
illumination mode On/Off/Auto On
9Setting night view LED
illumination mode On/Off/Auto Auto
10 Setting ring-back tone
Ringing one time
Ring continuously
No ring-back tone
Ringing one time
11 Setting image display mode
Alternate switching mode
Zoom mode
Full screen mode
Alternate switching mode
12 RAINY_COVER congure Provide / not Provide

-7-
Setting Door Station Address
Setting Door Station Calling Mode
Total 4 addresses can be congured. It can be modied either before or after installation.
0 is default, to change the setting, please follow the steps:
UNLOCK Indicator:OFF
TALK Indicator:OFF Buzzer Beep+, Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep+
In standby mode, press
KEY_SET button once
Press KEY_1 button to set
the first door station.
Press KEY_2 button to set
the second door station.
Press KEY_3 button to set
the third door station.
Press KEY_4 button to set
the fourth door station.
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep,Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep,Beep,Beep
ID=0,1st door station ID=1,2nd door station ID=2,3rd door station ID=3,4th door station
SETUP INSTRUCTIONS
• If setting mode has not been exited, you can change the address of door station by pressing KEY1~4
freely.
• The LED_NAME indicator will always blink until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press KEY_SET button four times to exit out the setting mode manually.
There are two calling modes for door station.
As apartment system door station, the calling mode is Standard calling mode.
As villa system door station, the calling mode is Group calling mode.
Please know that the door station work in Standard calling mode by default.

-8-
• If setting mode has not been exited, you can change the calling mode by pressing KEY1 circularly.
• The LED_NAME indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press KEY_SET button three times to exit out the setting mode manually.
SETUP INSTRUCTIONS
* More details about code setting for monitor, please refer to corresponding user manual .
Each call button will respond different addresses when set in different calling mode. Refer to the
followings for more informations.
Call buttonA: call the monitor with address 01 by default.
Call buttonB: call the monitor with address 02 by default.
Call buttonC: call the monitor with address 03 by default.
Call buttonD: call the monitor with address 04 by default.
Call buttonE: call the monitor with address 05 by default.
Call buttonF: call the monitor with address 06 by default.
Call buttonG: call the monitor with address 07 by default.
Call buttonH: call the monitor with address 08 by default.
Call buttonA: Call all monitors in group address from
00~15.(one of the monitor should be set to 00)
Call buttonB,C,D,E,F,G,H: Call all monitors in group
address from 16~31. (one of the monitor should be set to
16)
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button twice.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+
Press KEY_1 button to
activate Standard calling
mode for door station.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep, Beep
Press KEY_1 button again
to activate Group calling
mode for door station.
Press KEY_1
A
B
C
D
E
F
Apartment system
door station
Villa system door station
B
A
G
H
RF CARD
RF CARD
1.Standard calling mode(Address range 01-08 by
default)
2.Group calling mode
To change this setting, please follow the steps:

-9-
Setting Camera N/P Standard
Setting Prompt Voice
The standard of the camera can be adjusted at any time, that means the quality of image on
screen can be set to differ.
P standard is default, to change the setting, please follow the steps:
Max. 9-languages voice to select, No voice, Voice 1 and Voice 2 ...
Voice 1 is default, to change the setting, please follow the steps:
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button twice.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+
Press KEY_2 button to set the
camera standard to P
standard.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep, Beep
Press KEY_2 button again
to set the camera standard
to N standard.
Press KEY_2
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button twice.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Play the voice 1
Press KEY_3 button to set the
prompt voice to Voice 1.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Play the voice 2
Press KEY_3 button again
to set the prompt voice to
Voice 2.
Beep+
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer
Press KEY_3 button again
and again to set the prompt
voice to No voice.
Press KEY_3
SETUP INSTRUCTIONS
• If setting mode has not been exited, you can change the camera standard by pressing KEY2 circularly.
• The LED_NAME indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press KEY_SET button three times to exit out the setting mode manually.
• If setting mode has not been exited, you can change the prompt voice by pressing KEY3 circularly.
• The LED_NAME indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• The voice can be customized.

-10-
SETUP INSTRUCTIONS
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button twice.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Play the volume
Press KEY_4 button to set the
volume level.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer
Press KEY_4
Play the volume level 9
Press KEY_4 button again
and again to set the volume
level you want.
Setting Unlock Mode
There are 2 unlock modes, Normally opened and Normally closed.
Normally opened is default, to change the setting, please follow the steps:
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+
Press KEY_1 button to set
the unlock mode to
Normally opened.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep, Beep
Press KEY_1 button again
to set the unlock mode to
Normally closed.
Press KEY_1
• If setting mode has not been exited, you can change the unlock mode by pressing KEY1 circularly.
• The LED_NAME indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press KEY_SET button twice to exit out the setting mode manually.
Setting Prompt Voice Volume
• If setting mode has not been exited, you can change the volume level by pressing KEY4 circularly.
• The LED_NAME indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
Total 9 level can be congured. It can be modied either before or after installation.
6 is default, to change the setting, please follow the steps:

-11-
Setting Nameplate Illumination Mode
Setting Unlock Time
There are 3 illumination modes for nameplate indicator, Normally on,Normally off and Auto.
Normally on is default, to change the setting, please follow the steps:
By default, the unlock time is 1s, but it can be changed,the setting range is 1s~99s.
Follow the steps:
SETUP INSTRUCTIONS
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep,Beep......
Press and hold on KEY_2
button. The time you holding
on is the new unlock time.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+
Press KEY_3 button to set
the nameplate illumination
mode to Normally on.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep, Beep
Press KEY_3 button again
to set the nameplate illumina-
tion mode to Normally off.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep, Beep,Beep
Press KEY_3 button again
and again to set the nameplate
illumination mode to Auto.
Press KEY_3
• When entering time delayed setting, the buzzer sound one time every second.
• The LED_NAME indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press KEY_SET button twice to exit out the setting mode manually.
• If setting mode has not been exited, you can change the nameplate illumination mode by pressing KEY3
circularly.
• The LED_NAME indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press KEY_SET button twice to exit out the setting mode manually.

-12-
Setting Ring-back Tone
If allow ring-back tone, press the call button to call monitor, a ring-back call tone can be heard
from door station.
There are 3 ring-back call tones, Ringing one time, Ringing continuously and No ring-back
tone.
Ringing one time is default, to change the setting, please follow the steps:
Setting Night View LED Illumination Mode
There are 3 working modes for night view LED indicator, Normally on,Normally off and Auto.
Auto is default, to change the setting, please follow the steps:
SETUP INSTRUCTIONS
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+
Press KEY_4 button to set
the night view LED mode
to Normally on.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep, Beep
Press KEY_4 button again
to set the night view LED
mode to Normally off.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep, Beep,Beep
Press KEY_4 button again
and again to set the night
view LED mode to Auto.
Press KEY_4
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button four
times.
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep+
Press KEY_1 button to set
the ring-back call tone ringing
one time.
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep, Beep
Press KEY_1 button again
to set the ring-back call tone
ringing continuously.
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep, Beep,Beep
Press KEY_1 button again
and again to close ring-back
call tone.
Press KEY_1
• If setting mode has not been exited, you can change the night view LED illumination mode by pressing
KEY4 circularly.
• The LED_NAME indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press KEY_SET button twice to exit out the setting mode manually.
• If setting mode has not been exited, you can change the ring-back tone by pressing KEY1 circularly.
• The LED_NAME indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press KEY_SET button once to exit out the setting mode manually.

-13-
Setting Image Display Mode
Please know that this setting is only effective for monitors which does not support man-
ual operation for pan-tilt.
When door station calls monitor,the image will be displayed on screen,there are 3 modes for im-
age displayed, Alternate switching mode,Zoom mode and Full screen mode.
Alternate switching mode: when the monitor being called, switch at regular time(5s) between
Full screen and Zoom image.
Zoom mode: when the monitor being called, the image will be displayed on full screen for 5
seconds, then switch to Zoom image.
Full screen mode: when the monitor being called, the image will be always displayed on Full
screen.
Alternate switching mode is default, to change the setting, please follow the steps:
When answering the call, the image switching reminder can be activated or forbidden.
If set to activated mode, the image switching reminder will be different for different image display
mode.
Alternate switching mode: When answering the call, image switching reminder is not effective.
Zoom mode: When answering the call, the image will be displayed on full screen for 5 sec-
onds, then switch to Zoom image to remind to enter talking status.
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button four
times.
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep+
Press KEY_2 button to set
the image display mode
to Cycle switching.
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep, Beep
Press KEY_2 button again
to set the image display
mode to Zoom mode.
UNLOCK Indicator:ON
CALL Indicator:ON
Press KEY_2
Buzzer Beep, Beep,Beep
Press KEY_2 button again
and again to set the image
display mode to Full screen.
During setting mode, press KEY-2 to switch
Cycle switching mode, Zoom mode and Full screen mode in cycle.
SETUP INSTRUCTIONS
When the monitor being called
When answering the call
• If setting mode has not been exited, you can change the image display mode by pressing KEY2 circularly.
• The LED_NAME indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press KEY_SET button once to exit out the setting mode manually.

-14-
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button four
times.
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep+
Press KEY_3 button to
activate image switching
when answering the call.
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep, Beep
Press KEY_3 button again
to forbid image switching
when answering the call.
Press KEY_3
SETUP INSTRUCTIONS
• If setting mode has not been exited, you can change the image display mode by pressing KEY3 circularly.
• The LED_NAME indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press KEY_SET button once to exit out the setting mode manually.
Full screen mode: When answering the call, the image will be displayed on Zoom mode for 5
seconds, then switch to Full screen to remind to enter talking status.
If set to forbidden mode, there is no image switching reminder at any image display mode.
Activated is default, to change the setting, please follow the steps:
RAINY_COVER Congure
If can be set the rainy cover mode.
Mounting the rainy cover is default, to change the setting, please follow the steps:
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button four
times.
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep+
Press KEY_4 button to set
the rainy cover mode.
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep, Beep
Press KEY_4 button again
to set the no rainy cover
mode.
Press KEY_4
• If setting mode has not been exited, you can change rainy cover mode by pressing KEY4 circularly.
• The LED_NAME indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press KEY_SET button once to exit out the setting mode manually.

-15-
Registering ID Card
• Up to 320 user cards can be registered by the door station.
• Easy management with LED status and sound hints.
• There are two master cards, one MASTER CARD ADD card
and one MASTER CARD DELETE card, When registered new
master cards, the old master cards are invalid automatically.
• Card reading distance is less than 3cm.
• The master cards are necessary when you add or delete user
cards. Please keep it well for future use.
• EM card, 125kHz.
Authorizing master cards:
By default,there are two master cards marked MASTER CARD ADD and MASTER CARD
DELETE ,but you should know that the master card can be authorized by users at any time.
That means any two user cards can be authorized to master cards,When registered new master
cards, the old master cards will be invalid automatically.
SETUP INSTRUCTIONS
UNLOCK Indicator:Blink two times
CALL Indicator:OFF
Buzzer Beep,Beep
Show the first card to ID
card window, set the card
of MASTER CARD ADD.
UNLOCK Indicator:Blink three times
CALL Indicator:OFF
Buzzer Beep,Beep,Beep
Show the second card to ID
card window, set the card of
MASTER CARD DELETE.
UNLOCK Indicator:OFF
CALL Indicator:OFF
Buzzer Beep+, Beep
When power on in 10s,press
and hold on KEY_SET button
for 3s.
UNLOCK Indicator:Blink one time
CALL Indicator:OFF
Buzzer Beep+
Press KEY_2 button.
• The LED_NAME indicator will blink twice per second until exit out the master card authorized mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• It will exit out setting mode automatically after showing these two cards,the UNLOCK&CALL indicator will be
turned off.

-16-
SETUP INSTRUCTIONS
Switching Access Control:
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+, Beep
Show the master card of
MASTER CARD ADD to ID
card window in standby.
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep+, Beep
Show the master card of
MASTER CARD DELETE
to ID card window.
UNLOCK Indicator:OFF
CALL Indicator:OFF
Buzzer Beep+
Show the master card of
MASTER CARD DELETE
again to switch as a door
station access control.
UNLOCK Indicator:OFF
CALL Indicator:OFF
Buzzer Beep,Beep
Show the master card of
MASTER CARD DELETE
again to switch to DT-ACC
controlled.
The access can be controlled by door station or DT-ACC,so it’s available to switch the access
function.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• If current access is controlled by door station, next access switching setting is controlled by DT-ACC.
Adding User Cards:
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+, Beep
Show the master card of
MASTER CARD ADD to ID
card window in standby.
UNLOCK Indicator:OFF
CALL Indicator:Blink one time
Buzzer Beep+
Show user cards to be
added in sequence.
UNLOCK Indicator:OFF
CALL Indicator:OFF
Buzzer Beep, Beep+
Show the master card of
MASTER CARD ADD again
to exit.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• To add user card, the access must be controlled by door station.

-17-
SETUP INSTRUCTIONS
Initializing Access (delete all user cards):
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+, Beep
Show the master card of
MASTER CARD DELETE to
ID card window in standby.
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep+, Beep
UNLOCK Indicator:Blink for some time
CALL Indicator:Blink for some time
Buzzer Beep
Show the master card of
MASTER CARD ADD again,
format is activated.
Show the master card of
MASTER CARD ADD to ID
card window.
Deleting User Cards:
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+, Beep
Show the master card of
MASTER CARD DELETE to
ID card window in standby.
UNLOCK Indicator:Blink one time
CALL Indicator:OFF
Buzzer Beep+
Show user cards to be
deleted in sequence.
UNLOCK Indicator:OFF
CALL Indicator:OFF
Buzzer Beep, Beep+
Show the master card of
MASTER CARD DELETE
again to exit.
• .If without any operation in 10 seconds, it will exit out setting mode automatically.
• To add user card, the access must be controlled by door station.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• To add user card, the access must be controlled by door station.
• At step3, the UNLOCK & CALL indicator will blink all time until formatting is nished.
• When formatting is nished, UNLOCK & CALL indicator will be turned off and sound “ Beep+ ”, and exit out
setting mode automatically.
Restore To Default
The restore to default function allows the user to recover the settings to factory setting.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+, Beep
When power on in 10s,press
and hold on KEY_SET button
for 3s.
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep+
Press KEY_3 button.
• The LED_NAME indicator will blink twice per second until exit out the restore to default mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• When restoring is finished, UNLOCK & CALL indicator will be turned off, and exit out setting mode
automatically.

-18-
Connecting Electric Lock
Door Lock Controlled with Internal Power
Door Lock Controlled with Dry Contact
1.Electronic lock of Power-on-to-unlock
type should be used.
2.The door lock is limited to 12V, and hold-
ing current must be less than 250mA.
3.The jumper should be placed on position
2 and 3 before connecting.
4.The door lock control is not timed from
Exit Button(EB).
5.The Unlock Mode must be set to 0 (by
default).
1.The external power supply must be used
according to the lock.
2.The inside relay contact is restricted to
230Vac 1A or 24Vdc 1A.
3.The jumper must be taken off before
connecting.
4.Setup the Unlock Mode according to
different lock types.
• Power-on-to-unlock type:Unlock
Mode=0 (by default)
• Power-off-to-unlock type:Unlock
Mode=1
EB
*
LOCK
Jumper position on 2&3
1 2 3
L1 L2 PL S+ S-
Take off the jumper
1 2 3
L1 L2 PL S+ S-
LOCK
POWER
SUPPLY
WIRING
* DT-RLC relay actuator is needed for 2nd lock connection.

-19-
WIRING
• Door stations were congured as the villa system door stations.
• Max.4 door stations can be connected to the system.
• Ensure to set the correct address for each door station, Refer to Page 8 for more details
about the address setting of door stations.
As The Villa System Door Stations
100~240VAC
DBC4A1
A B C D
OFF
ON
Impedance
switch
BUS(IM) BUS(DS)
PC6A
AC~
ID=0
1st door station
ID=1
2nd door station
ID=2
3rd door station
ID=3
4th door station
L1 L2 PL S+ S- L1 L2 PL S+ S- L1 L2 PL S+ S- L1 L2 PL S+ S-
RF CARD RF CARD RF CARD RF CARD
Code=0,DIP6=offCode=30,DIP6=offCode=31,DIP6=on

-20-
As The Apartment System Door Stations
• Door stations were congured as the apartment system door stations.
• The door station is also compatible with other monitors which are provided by our company.
WIRING
RF CARD
A B C D
DBC4A1
2 Wire cable
CAT5 cable
Common
Door Station
BUS(IM) BUS(DS)
PC6A
AC~
IPG
BUS(DS) BUS(IM)
RF CARD
LAN Switcher
Guard Unit
BUS(IM) BUS(DS)
PC6A
AC~
BUS(IM) BUS(DS)
PC6A
AC~
IPG
BUS(DS) BUS(IM)
This manual suits for next models
3
Table of contents
Other NY Wholesale Intercom System manuals