manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. OBO Bettermann
  6. •
  7. Inverter
  8. •
  9. OBO Bettermann PKV-C1000ST100 User manual

OBO Bettermann PKV-C1000ST100 User manual

Uoc max:
Uoc max:
1000V DC
1000V DC
P
P
V
V
-pr
-pr
otection
otection
1
2
String 1
WR1
WR2 String 2
String 1
WR1
A
B
OUT IN
Uoc max:
Uoc max:
1000V DC
1000V DC
P
P
V
V
-pr
-pr
otection
otection
Uoc max:
Uoc max:
1000V DC
1000V DC
P
P
V
V
-pr
-pr
otection
otection
Uoc max:
Uoc max:
1000V DC
1000V DC
P
P
V
V
-pr
-pr
otection
otection
A
B
green ok
redreplace
replace
Technische Daten/Technical data/
Teknisk data
Typ /Type/Typ PKV-C1000ST100 PKV-C1000ST110
Artikel-Nr./Article no./Artikelnr 5088501 5088503
UC DC 1000 V
LPZ 1 -> 2
UP≤ 4,0 kV
In20 kA
Imax 40 kA
°C -40 °C - + 80°C
IP-Schutzart Gehäuse/
IP protection rating for housing/
IP klass kapsling
66
Trennschalter/Switch-disconnector/Brytare
U 1000 V
I 20 A
OUT 1IN 1
IN 1 OUT 1
IN 2OUT 2
OUT 2IN 2
IN OUT
A
B
DE PV-Systemlösung mit Trennschalter
Montageanleitung
EN PV system solution with switch-dis-
connector
Mounting instructions
SE PV-kapsling med DC brytare
Monteringsanvisning
OBO Bettermann
Holding GmbH & Co. KG
P. O. Box 1120
58694 Menden
Germany
Customer Service
Tel.: +49 23 73 89 - 17 00
Fax: +49 23 73 89 - 12 38
www.obo-bettermann.com
OBORD 200064 HAFA 49523515 Stand 02/2020
Building Connections
PKV-C1000ST100
PKV-C1000ST110
DE
PV-Systemlösung im Gehäuse, Art.-Nr. 5088501, 5088503
Produktbeschreibung
Vormontierte PV-Systemlösung mit Varistor-Ableiter
zum Potentialausgleich bei PV-DC-Systemen, steckbar
mit Abtrennvorrichtung in fehlerresistenter Y-Schaltung
nach VDE 0100-712 (50539-12). Mit Trennschalter zur
sicheren Abschaltung der DC-String-Leitung, ein PV-
String-Eingang (MC4-Steckverbinder) auf einen
MPP-Eingang.
– Für isolierte oder geerdete PV-Systeme mit oder
ohne getrennter Blitzschutzanlage
– Thermodynamische Abtrennvorrichtung
– Statusanzeige
Lieferumfang
A 5088501:
1 x V20-C 3-PH-1000, 1 x Trennschalter, MC4-Stecker
B 5088503:
2 x V20-C 3-PH-1000, 2 x Trennschalter, MC4-Stecker
Zielgruppe
Das Gerät darf nur durch eine Elektrofachkraft montiert
und angeschlossen werden.
Allgemeine Sicherheitshinweise
– Vor dem Arbeiten an Stromleitungen die Spannungsfrei-
heit herstellen und gegen Wiedereinschalten sichern.
– Gerät nicht bei Gewitter montieren.
Systemlösung montieren
ACHTUNG
Kondenswasserbildung!
Bei Gefahr von erhöhter Kondenswasserbildung durch
Wind, Eis, Temperatur oder Sonne sind gegebenen-
falls zusätzliche Maßnahmen erforderlich. Ein
Druckausgleichselement ist bereits verbaut.
1. Beiliegende Außenbefestigungen in die Halterungen
auf der Rückseite des Gehäuses stecken
1
.
2. Montagepunkte für die Außenbefestigung anzeich-
nen und vorbohren.
3. Gehäuse mit entsprechendem Befestigungsmaterial
montieren
2
.
4. PV-Systemlösung über MC4-Steckverbinder ge-
mäß Bild anschließen.
Systemlösung warten
Schutzgerät alle 2-4 Jahre und nach einem Blitzein-
schlag überprüfen:
– Ist die optische Statusanzeige rot, muss das Über-
spannungsschutzgerät ersetzt werden .
Systemlösung demontieren
Die Demontage der Systemlösung erfolgt in umgekehr-
ter Reihenfolge wie die Montage.
Systemlösung entsorgen
– Verpackung wie Hausmüll
– Kunststoffteile wie Kunststoff
– Elektronikteile wie Elektronikabfall
Die örtlichen Müllentsorgungsvorschriften beachten.
EN
PV system solution in the housing, article no. 5088501,
5088503
Product description
Pre-mounted PV system solution with varistor arrester
for equipotential bonding in PV-DC systems, plug-in
with cut-off unit in error-resistant Y circuit according to
VDE 0100-712 (50539-12). With switch-disconnector
for safe disconnection of the DC string cable, one PV
string input (MC4 plug connector) to one MPP input.
– For insulated or earthed PV systems with or without
isolated lightning protection system
– Thermodynamic cut-off unit
– Status display
Scope of delivery
A
5088501:
1 x V20-C 3-PH-1000, 1 x switch-disconnector, MC4
connector
B
5088503:
2 x V20-C 3-PH-1000, 2 x switch-disconnectors, MC4
connector
Target group
The device may only be mounted and connected by an
electrical engineer.
General safety information
– Before working on power cables, ensure that they are
de-energised and secure them against unintentional
switch-on.
– Do not mount the device during a thunderstorm.
Mounting a system solution
ATTENTION Condensation!
If there is a danger of increased condensation
forming through wind, ice, temperature or sunlight,
further measures may be necessary. A pressure com-
pensation element is already installed.
1. Insert the provided external fastenings into the bra-
ckets on the rear of the housing
1
.
2. Draw and pre-drill the mounting points for the exter-
nal fastening.
3. Mount the housing with appropriate fastening mate-
rial
2
.
4. Connect the PV system solution using the MC4
connector as shown in Figure .
Maintaining a system solution
Check the protection device every 2–4 years and after
lightning strikes:
– If the visual status display is red, the surge protecti-
on device must be replaced .
Dismantling a system solution
Dismantling the system solution takes place in the re-
verse order to mounting.
Disposing of a system solution
– Packaging as household waste
– Plastic parts as plastic
– Electronic parts as electronic waste
Comply with the local waste disposal regulations.
SE
PV kapsling, komplett solcellskapsling, artnr: 5088501,
5088503 (e-nr 5273768, 5273769)
Produktbeskrivning
Färdigkopplad solcellskapsling med överspänningss-
kydd för potentialutjämning i solcellsanläggningar DC,
utbytbara patroner med felsäker Y-koppling enligt SS
EN 50539-12. Med DC-brytare för säker frånkoppling
av DC-sträng, 1 stränganslutning per MC-4 kontakt.
– För PV-system utan yttre åskskydd, eller isolerade
åskskyddssystem
– Termisk bortkoppling
– Statusindikering
Innehåll vid leverans -
A
5088501:
1 x V20-C 3-PH-1000, 1 x brytare, MC4-kontakt
B
5088503:
2 x V20-C 3-PH-1000, 2 x brytare, MC4-kontakt
Hantering
Enheten får endast installeras och kopplas in av behö-
riga elektriker.
Allmänna säkerhetsanvisningar
– Bryt strömmen innan arbete påbörjas, låsbar brytare för
skydd mot återinkoppling.
– Installera inte enheten under pågående åskväder.
Systemlösning - montage
OBSERVERA
Kondens!
Vid risk för kondens från vind, is, temperatur eller sol
krävs eventuellt ytterligare åtgärder! Kapslingen är
försedd med dräneringsplugg.
1. Sätt i de medföljande externa fästena i konsolerna
på kapslingens baksida
1
.
2. Markera och förborra monteringspunkterna för fast-
sättning.
3. Montera kapslingen med lämpligt fastsättningsma-
terial
2
.
4. PV-kapslingen ansluts med MC4-kontakt enligt
bild .
Systemlösning revisionskontroll
Kontrollera skyddet var 2-4 år, eller efter ett blixtneds-
lag:
– Om den optiska indikeringen är röd måste överspän-
ningsskyddet bytas ut .
Systemlösning - demontering
Systemlösningen demonteras i omvänd monterings-
ordning.
Systemlösning kassering
– Förpackning: hushållsavfall
– Plast sorteras som plast
– Elektronik som elektronikavfall
Följ lokala regler för avfallshantering.

This manual suits for next models

1

Popular Inverter manuals by other brands

AIMS Power PWRI8K22050 instruction manual

AIMS Power

AIMS Power PWRI8K22050 instruction manual

SUNTAO SD Series Product user manual

SUNTAO

SUNTAO SD Series Product user manual

Xantrex 807-1055 owner's guide

Xantrex

Xantrex 807-1055 owner's guide

TECO A510s instruction manual

TECO

TECO A510s instruction manual

SAJ AS1-3KS-5.1 user manual

SAJ

SAJ AS1-3KS-5.1 user manual

Kloben SKY 8 CPC 58 manual

Kloben

Kloben SKY 8 CPC 58 manual

Suaoki SM-P1818B user manual

Suaoki

Suaoki SM-P1818B user manual

Advanced Energy AE 3TL 600 Series Installation and operation manual

Advanced Energy

Advanced Energy AE 3TL 600 Series Installation and operation manual

GeBe POWERMAN 2000i manual

GeBe

GeBe POWERMAN 2000i manual

Signal Forge 1000 user manual

Signal Forge

Signal Forge 1000 user manual

ZIEHL-ABEGG ZA dyn 4C Original operating instructions

ZIEHL-ABEGG

ZIEHL-ABEGG ZA dyn 4C Original operating instructions

Draper 28814 user manual

Draper

Draper 28814 user manual

Western Co Leonardo System 3000 12V Technical manual

Western Co

Western Co Leonardo System 3000 12V Technical manual

FJC 53300 instruction manual

FJC

FJC 53300 instruction manual

Hoymiles HM-300 Quick installation guide

Hoymiles

Hoymiles HM-300 Quick installation guide

Epever LS-B Series manual

Epever

Epever LS-B Series manual

Voltech ISC1500 Installation and operating instructions

Voltech

Voltech ISC1500 Installation and operating instructions

Senci SC4000C instruction manual

Senci

Senci SC4000C instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.