Ocean Matrix OMX-12BTMX0001 User manual


Household entertainment sharing and Lecture room display and control
Showroom display and control
Meeting room presentation and control Classroom display and control
Compatible with the OMX-01HMHM0002 receivers
HDBaseT Transmitter
HDBaseT Receivers for Connecting to the HDBaseT out via CAT5e/6/7
Up to 3 HDMI Display (TV or Monitor)
The Ocean Matrix OMX-12BTMX0001 is the perfect device for further extending your HDBaseT
signal, while still supporting the highest quality of uncompressed 4K HD video over a single CAT5e/6
cable. The OMX-12BTMX0001 also features 3x HDMI outputs for sending video to local displays, and
supports uncompressed multi-channel audio, EDID management, and bi-directional IR and RS-232
control.
APPLICATIONS
INTRODUCTION
PACKAGE CONTENTS
SYSTEM REQUIREMENTS
Main unit
Operating instructions
24V1A Four countries DC power supply
1x IR TX unit
1x IR RX unit
1x Phoenix plugs for RS232 cable termination
1x USB AM to Micro 5P 0.8m cable
2x Mounting Ears
1
2
3
4
5
6
7
8
Operating Instruction

Operating Instruction
HDMI 2.0 Bandwidth Up To 18Gbps
Supports Resolutions Up To 4K @60hz YUV 4:4:4
Transmits 4K Up To 40m, 1080p Up To 70m
HDR10, 3D Support
1x HDBaseT In; 1x HDBaseT Out With 3x Looping HDMI Out
Bi-Directional Wide Band IR and RS232 Pass Through
Supports 7.1CH & Dolby True HD, DTS-HD Audio
HDCP2.2/ HDCP1.4 Compliant
Built-in EDID Management
Output Video
Output Audio
Power Supply
Power Consumption
Dimensions
Mass (Main unit)
Video Format Supported
Operating Temperature Range
Operating Humidity Range
Input Video Signal
Input DDC Signal
Maximum Transmission Distance
24 V1A
11 Watts
9.6in (L) X 5.5in (W) X .9in (H)
1.06Kg (2.3lbs)
70 meters for 1080P, 40 meters for 4K
-10 to +55°C (14 to +131 °F)
5 to 90 % RH (no condensation)
0.5-1.0 volts p-p
5 volts p-p (TTL)
DTV/HD TV:
4K/1080P/1080i/720P/576P/480P/576i/480i
UHDTV HDMI 2.0 + HDCP 2.2
Support 7.1ch DTS-HD, Dolby-HD
Features
Specifications
Supported Audio Rate Up to 48Khz

Operating Instruction
HDBaseT SPLITTER
HDBaseT
Equipped
Receiver
HDBaseT
Equipped
Receiver
HDBaseT
Equipped
Receiver

Operating Instruction
CONNECTION DIAGRAM
HDBaseT Equipped Receiver
HDBaseT
Equipped
Receiver

①
IR In: Connect the supplied IR Receiver cable for IR signal transmission. Place the IR blaster in direct
line-of-sight of the equipment to be controlled.
②
IR Out: Connect the supplied IR Emitter cable for IR signal transmission. Place the IR blaster in direct
line of sight of the equipment to be controlled.
③
RS-232: Connect a PC or laptop with phoenix terminal for the transmission of RS232 commands.
④
Factory use only.
⑤
EDID: DIP switches 1 and 2 are for EDID setting adjustments. DIP Switches 3 and 4 are for RS-232
ID settings.
ID: Through a 4 PIN DIP Switch, Set the ID number on the 3rd and 4th bits. Upper means 0, Lower
means 1.
⑥
RESET: press and release for EDID setting; press and hold power to reset the product.
Operating Instruction
OPERATION CONTROLS AND FUNCTIONS
Front Panel:
①
DC/24V: Plug the 24V DC power supply into the unit and connect adaptor to an AC outlet
②
HDBaseT Out: Connect to the receiver with a single CAT5e/6/7 cable
③
HDMI Out1: Connect to a HDMI equipped TV/Monitor
④
HDMI Out2: Connect to a HDMI equipped TV/Monitor
⑤
HDMI Out3: Connect to a HDMI equipped TV/Monitor
⑥
HDBaseT In: Connect to the transmitter with a single CAT5e/6/7 cable
Rear Panel
1 2 3 4 5 6
1 2 3 4 5 6

Operating Instruction
Pressing and releasing: Prompts three different EDID modes; Default EDID,
Copy EDID and Priority mode
2). Copy EDID mode: HDMI1, HDMI2, HDMI3 and HDBT Out can be copied
according to the DIP switch. After setting, the HDBT IN indicator will slowly flash for
3 seconds and then return to normal operation.
3). Priority mode: Prioritizes HDMI outputs starting with HDMI 1, then HMDI 2, and
HDMI 3. EDID will copy the highest priority and send that EDID data to the lower
priority outputs. After setting, HDBT IN light will flash quickly then revert back to normal
after 3 seconds.
Press and hold the reset / EDID button for about 3 seconds to restart the product. All
the blue indicators will flash 3 times, and the TV will re-read the EDID.
Note: After setting the EDID mode, when indicator returns to normal, restart the
product to get the EDID mode.
1). Default EDID mode: 4 different EDID types can be set according to the DIP
switch. After setting, the HDBT IN indicator light will turn off and then return to
normal operation.
00
01
10
11
00
01
10
11
HDBT Out
HDMI 1 Out
HDMI 2 Out
HDMI 3 Out
4k60-4:4:4-2.0
(
Default)
4K60-4:4:4-5.1-HDR
4K30-3D-2.0
1080p60-3D-2.0
Button instructions:
DIP Switch
DIP Switch
EDID
EDID

Operating Instruction
For example: Repeater’s ID: 00; TX sends command to the Repeater,
the command will be: #bypass id1 baud=115200 str=#down.
Then the repeater will get “#down”.
When paired with different devices, the commands are slightly different.
ID: Through a 4 PIN DIP Switch, Set the ID number on the 3rd and 4th bits. Upper means 0,
Lower means 1. Then send the command to achieve RS-232 dual way transmission. The ID
number corresponds to the following instruction table:
Two way IR pass though is only supported between Transmitter and Receiver units. Two way
IR pass through between multiple repeaters is not supported.
IR pass through instruction:
RS-232 pass through instruction:
#bypass
0
:
all
1: ID 00
2: ID 01
3: ID 10
4: ID 11
id%
ID number
baud=%d
Baud rate
115200
57600
38400
19200
14400
9600
4800
2400
Clean with a soft, dry cloth. Never use alcohol, paint thinner of benzine to clean this unit.
MAINTENANCE
1 Year
WARRANTY

Operating Instruction
The unit should be serviced by qualified service personnel if:
(a) The DC power supply cord or AC adaptor has been damaged
(b) Objects or liquids have gotten into the unit
(c) The unit has been exposed to rain
(d) The unit does not operate normally or exhibits a marked change in performance; The unit has
been dropped or the cabinet is damaged.
(2) Servicing Personnel: Do not attempt to service the unit beyond that described in these operating
instructions. Refer all other servicing to authorized servicing personnel.
(3) Replacement parts: When parts need replacing ensure the servicer uses parts specified by the
manufacturer. Unauthorized substitutes may result in fire, electric shock, or other hazards.
(4) Safety check: After repairs or service, ask the servicer to perform safety checks to confirm that the
unit is in proper working condition.
Damage requiring service:
PRODUCT SERVICE
Always follow basic safety precautions to reduce the risk of fire, electrical shock and
injury to persons.
To prevent fire or shock hazard, do not expose the unit to rain, moisture or install this
product near water.
Never spill liquid of any kind on or into this product.
Never push an object of any kind into this product through any openings or empty slots
in the unit, as you may damage parts inside the unit.
Do not attach the power supply cabling to building surfaces.
Use only the supplied power supply unit (PSU). Do not use the PSU if it is damaged.
Do not allow anything to rest on the power cabling or allow any weight to be placed
upon it or any person walk on it.
To protect the unit from overheating, do not block any vents or openings in the unit
housing that provide ventilation and allow for sufficient space for air to circulate around
the unit
Please read all instructions before attempting to unpack, install or operate this equipment
and before connecting the power supply.
Please keep the following in mind as you unpack and install the unit:
SAFETY PRECAUTIONS
812 Kings Highway | Saugerties, NY 12477 | 845-246-7500 | www.oceanmatrix.com
100% Employee Owned Division of Tower Products Incorporated
Table of contents