CONTENTS
2 www.ochsner.com | BA-982018-AIR FALCON-ih-EN
PLEASE NOTE
1. Information on documentation 4
1.1 Safety information 5
1.1.1 Arrangement of safety information 5
1.1.2 Symbols and possible dangers 5
1.1.3 Keywords 5
1.2 Other symbols 5
1.3 Units of measurement 5
1.4 Specied performance gures 5
2. Safety 5
2.1 Intended use 5
2.2 General safety information 5
3. How split systems work 8
4. Appliance description 10
4.1 Scope of delivery 10
4.2 Indoor unit hydraulics 10
4.3 Appliance components 10
4.3 .1 Indoor unit 10
4.3.2 Outdoor unit 11
4.3.3 Heat pump control unit 11
4.4 Name plate 11
5. Running costs 12
5.1 Flow temperatures 12
5.2 Ventilation 12
5.3 Heating setback program 12
6. Maintenance and care 12
6.1 General 12
6.2 Testing the safety valve 13
6.3 Installation in coastal areas 13
6.4 Maintenance contract 13
7. Problem solving 14
7.1 Problem solving by appliance user 14
7. 2 Problem solving by qualied contractor 14
7. 2 .1 Resetting the high limit safety cut-out 14
8. Shutdown 15
OPER ATION
9. Controller description 16
9.1 System components 16
9.2 LED display on user interface 16
9.3 Main screen 16
9.3 .1 Main screen for heating circuits 16
9.3.2 Main screen for DHW circuits 17
9.3.3 Name 17
9.3.4 Current temperature of heating circuit/DHW circuit 17
9.3.5 Current relative humidity 17
9.3.6 Status of heat pump 17
9.3.7 Menu 17
9.3.8 Current DHW temperature 17
10. OTS app 18
10.1 Download the app and register 18
10.2 App management 18
10.2.1 Opening app management 18
10.3 Test mode 18
10.3.1 Setting up test mode 19
11. Heating circuit 19
11.1 Setting the room temperature 19
11. 2 Operating program 20
11. 2.1 Switching the heating circuit on/o 20
11.3 Setpoints 21
11. 3.1 Heating mode 21
11.3.2 Cooling mode 21
11.3.3 Setting target values 22
11.4 Seasonal operation 22
11.4.1 Setting seasonal operation 22
11.5 Weather-compensated controller 23
11. 5.1 Heating curve 23
11.5.2 Cooling curve 26
11.6 Enabling heating/cooling 29
11.7 Room temperature compensation 29
11.8 Frost protection 29
11.9 Operating data 29
11.9.1 Viewing operating data 30
12. DHW circuit 30
12.1 Setting the DHW temperature 30
12.2 Operating program 31
12.2.1 Setting the operating program 31
12.3 Target values and switching dierentials 32
12.3.1 Setting target values and switching dierentials 32
12.3.2 Switching o the DHW circuit 33
12.4 Anti-legionella mode 33
12.5 DHW heat input 34
12.6 Frost protection 34
12.7 Operating data 34
12 .7.1 Viewing operating data 35
13. Time program 35
13.1 Setting a time program 35
13.1.1 Example of a DHW time program 37
14. Electric auxiliary heater 38
14.1 Position of the auxiliary heater 38
14.2 Operating program 38
14. 2.1 Setting the operating program 38
14.3 Operating data 38
14. 3.1 Electric auxiliary heater internal 38
14.3.2 Buer tank electric auxiliary heater 39
14.3.3 DHW tank electric auxiliary heater 39
14.3.4 Viewing operating data 39
15. Bivalent point 39
16. Smart grid 40
16.1 Smart grid operating status 40
16.1.1 Viewing the operating status 40
16.2 Congurations 40
16.3 Smart grid in the heating circuit 40
16.3.1 Priority mode 40
16.3.2 Forced draw-o 40
16.4 Smart grid in DHW mode 40
16.4.1 Priority mode 40
16.4.2 Forced draw-o 41
16.5 Buer tank 41
16.5.1 Priority mode 41
16.5.2 Forced draw-o 41
17. Heat management 42
17.1 Operating data 42
17.1.1 Viewing operating data 42
17. 2 Output demand 42
17. 3 Statistics 42
17. 3.1 Overview 43
17. 3 . 2 Total values 43
17.3.3 Viewing statistics 44
18. Modbus communication 44
18 .1 Integration 44
18 .1.1 Control via building management system 44
18 .1. 2 Transfer of information to the heat pump 44
18 .1.3 Transfer of information to the building management sys-
tem 44
19. Standby protection 44
20. Status 45
20.1 Viewing the status 45
21. Rectifying faults 45
21.1 Fault messages 45
21.1.1 Charge aborted 47
21.2 Acknowledging faults 47
21.3 Appliance reset 48
21.4 Re-inputting available elements 48
21.5 System lockout 48
21.5 .1 Emergency mode 48
21.5.2 System failure 49
21.6 Reporting errors and faults 49