Ohlendorf SF T30V User manual

Instruction manual
The manual contains information and instructions that are necessary for safe
operation and maintenance of the instrument. Before using the device, the operating
instructions must be read carefully and follow all instructions. If you don´t follow the
instruction manual, or if you fail to comply with the warnings and instructions, you
may occur serious or fatal injuries or damage to the device.
Functionality
The equipment set consists of a transmitter OE - SF T30V with cable set and a
receiver OE - SF R30V. The transmitter supplies a modulated alternating voltage in
the affected line. This AC voltage generates an electric field in the line. If the
receiver is brought into proximity of the affected line with its search coil, the
modulated AC voltage is evaluated and displayed.
• Locating cables in the wall, line interruptions
• Line tracing in the ground, open circuit of wire loops for Robot - Lawnmowers
Safety guidelines
When working on electrical system, the respective accident prevention regulations of
the professional trade association for electrical equipment and utilities must be
followed. To avoid electrical shock, the valid safety and VDE regulations must be
strictly observed relative to excessive contact voltage when working with voltages

exceeding 120V (60V) DC or 50V (25V) rms. AC is working. The values in brackets
are valid for limited ranges (such as medicine and agriculture). Measurements in
dangerous proximity of electrical systems are only allowed directed by a qualified
electrician and never alone..
Check the meter and test leads before each use for exterior damage. Make sure that
the meter and the connecting cables are used in perfect condition. The instrument
may no longer be used if one or several functions fail or if no functional reliability can
be detected. If the operator's safety is no longer guaranteed, the device must be shut
down and be protected against use. This case finds application when the device:
• shows obvious damage.
• does not carry out the desired measurements.
• was stored under unfavourable conditions for a long period of time.
• has been exposed to mechanical stresses during transport.
If the device is exposed to an extremely high electromagnetic field, the function may
be affected.
Never attempt to disassemble a battery! The electrolyte in the cell is highly alkaline.
Burns! When it comes to contact with skin or clothing, these areas must be rinsed off
immediately with water.
If electrolyte gets in the eyes, immediately flush with clean water and consult a
doctor.
Never try to connect the two poles of a battery cell, for example, with a wire. Never
throw the batteries in a fire, as this could cause an explosion. Never expose batteries
to moisture. Note, when changing the battery to correct polarity. Wrongly polarized
batteries may destroy the device, furthermore, they may explode or ignite. Only use
the specified batteries! Avoid the instrument from direct sunlight and heat. Only then,
a proper function and a long service life are assured.
Normal use
The device may only be used under the conditions and for the purposes for which it
was designed. The operational safety is no longer guaranteed for modified or
adapted devices.
Connect the transmitter OE - SF T30V
(single pole application)
Connect the transmitter to only one conductor. The signal generated by the
transmitter is a high-frequency signal, even a single conductor can be searched or
tracked. The second circuit replaced the earth. With this arrangement, a high
frequency current flows through the conductor, over the air back to earth, very similar
to a radio transmitter and a radio receiver. We want to call this described mode from
now on “single pole application”.

Connect the red cord to the red socker of the transmitter and the black cord to the
black socket of the transmitter. Disconnect all lines from the lawnmover station.
Connect the red cable to one of the wires of the affected line. The black cable has an
attached spike, stick this spike into the ground. Turn on the transmitter by pressing
the button briefly. For control, the red LED lights. The transmitter will turn off after an
hour, but can be turned on when needed again. If the transmitter don´t stays on
again, the battery has undervoltage. The security level is activated to prevent deep
discharge. The transmitter must be charged using the AC adapter.
The receiver OE - SF R30V
Fitted is the receiver with a search coil and a high-sensitivity controlled RF amplifier.
The analysis is controlled by a processor. The signal strength of the received
modulated AC voltage is carried out visually and acoustically. To locate exactly the
break or interruption of the affected line, the near field key can be used.

For example, we are looking for the interruption of a line in the earth. The mode is the
single-ended application.
After the transmitter was taken as described above in operation, switch the receiver
with a short press on the power button. To check if the power is on the lowest red led
(it is the left Led in the picture) lights. As you approach the recipient of the affected
line, depending on the signal strength, the Leds shine red, yellow or green. The more
Led's light, the higher the received signal. In addition, they hear the beep, the speed
of which increases with increasing signal. Keep the receiver (as in the picture) and
rotate it through 90 °, you quickly identify the direction of the installed cable. Now you
can walk along the line until you cannot detect a received signal anymore. Now you
move slowly backwards until the signal can be seen again. You have the interruption
and want to locate the exact position. For this purpose press the button near field and
put the receiver close to the ground, check with slow movements where you can
receive the signal and from which point you cannot see the signal anymore. Now you
have found the exact interruption in the affected line.
The receiver will turn off after
one hour, but can be turned
on again. If the receiver is
not turned on, the battery
has under voltage and the
security level to prevent deep
discharge is working. The
transmitter must be charged
using the AC adapter. The
charging socket is
splashproof under the yellow
border..
This manual suits for next models
1
Table of contents
Popular Measuring Instrument manuals by other brands

tbs electronics
tbs electronics AROFLY Power Meter quick start guide

Steinberg Systems
Steinberg Systems SBS-SF-5000 user manual

DFM
DFM DFM 50 Operation manual

Danfoss
Danfoss AK-LM 330 Design guide

KROHNE
KROHNE IFC 090 Supplementary installation & operation instructions

S+S Regeltechnik
S+S Regeltechnik THERMASGARD RGTM1 Series Operating Instructions, Mounting & Installation