Okofen PELLETRONIC TOUCH User manual

OperatingManual
PELLETRONIC
TOUCH
TOUCHV2.00
ENGLISH
Europe’sspecialistinpelletheating
E1389EN2.0

Title:OperatingmanualPelletronicTouch
Articlenumber:E1389EN2.0
Version:2.0
Versionvalidfrom:05/2013
Approved:HumbergerStephan
Author:
ÖkoFENForschungs-undEntwicklungsgesmbH
Technicaleditorialdepartment
Gewerbepark1
A-4133Niederkappel
AUSTRIA
Tel.:0043(0)7286/7450
Fax:0043(0)7286/7450/10
www.oekofen.com
©byÖkoFENForschungs-undEntwicklungsgesmbH
Subjecttomodications

Contents
1DearCustomer.................................................................................................................................................5
2Useonlyforthepurposeintended...................................................................................................................6
3Typesofsafetywarningsign............................................................................................................................7
4Pelletronicheatingcontrollerandoperatingdevicewithtouchscreen............................................................8
4.1OperatingDevicewithTouchscreen.................................................................................................................8
4.2Openingwindow............................................................................................................................................8
4.3Chimneysweep...............................................................................................................................................9
4.4Usercontrolsandtheirfunction..................................................................................................................10
4.5MainMenu....................................................................................................................................................12
5Mode...............................................................................................................................................................13
6MeasuringValues...........................................................................................................................................14
7HeatingCircuit................................................................................................................................................16
7.1MeasuringvaluesHeatingcircuit....................................................................................................................17
7.2TimeprogrammeHeatingcircuit.....................................................................................................................17
7.3Party.............................................................................................................................................................19
7.4Vacation........................................................................................................................................................19
7.5HeatingcurveandHeatinglimits.....................................................................................................................20
7.6Screedprogramme........................................................................................................................................24
8Domestichotwater(DHW).............................................................................................................................25
8.1MeasuringvaluesDomestichotwater.............................................................................................................26
8.2TimeprogrammeDHW..................................................................................................................................26
9DHWReturnpump..........................................................................................................................................27
9.1MeasuringvaluesDHWReturnpump.............................................................................................................27
9.2TimeprogrammeDHWreturnpump...............................................................................................................28
10Solar.............................................................................................................................................................29
10.1MeasuringvaluesSolar................................................................................................................................29
10.2Solarcircuit.................................................................................................................................................30
10.3Yield-SolarEnergy....................................................................................................................................31
11Pellematic.....................................................................................................................................................32
11.1Permanentoperation....................................................................................................................................32
11.2MeasuringvaluesPellematic.........................................................................................................................33
11.3FullPower...................................................................................................................................................34
11.4De-ashingsystem........................................................................................................................................34
11.5FreshWaterModule.....................................................................................................................................35
11.6BoilerCleaning............................................................................................................................................35
11.7SuctionSystem............................................................................................................................................36
11.8Leveldetectionsystem.................................................................................................................................37
12HeatMainPump............................................................................................................................................38
13General.........................................................................................................................................................39
13.1Favorite1and2...........................................................................................................................................39
13.2LocalSettings..............................................................................................................................................40
13.3Malfunction..................................................................................................................................................41
13.4Information..................................................................................................................................................41
14Software.......................................................................................................................................................42
15CodeInput....................................................................................................................................................43
16Startup.........................................................................................................................................................44
17Descriptionoftheheatingcontrollermodule...............................................................................................45
17.1Settingtheaddressattheheatingcontroller..................................................................................................46
17.2Settingtheaddressattheburnercontroller....................................................................................................47
17.3SettingtheaddressattheboilercontrollerCMP.............................................................................................48
17.4Assemblyordisassemblyofthepowersupply...............................................................................................49
17.5Assemblyanddisassemblyoftheheatingcontrollerboard.............................................................................50
18DescriptionoftheOperatingdevicemodule................................................................................................51
18.1ReplacingaTouchoperatingdevice..............................................................................................................51
19Software.......................................................................................................................................................52
E1389EN2.0OperatingmanualPelletronicTouch

Contents
19.1Conguration...............................................................................................................................................52
19.2ActivatingthefunctionRoomthermostat........................................................................................................52
19.3UpdateHeatingController,TouchOperatingdeviceandRemoteControl.........................................................53
19.4SoftwareUpdate..........................................................................................................................................53
20PeripheryLearning.......................................................................................................................................54
21Heatingcircuitssettings...............................................................................................................................55
22DHWsettings................................................................................................................................................57
23DHWReturnPumpsettings..........................................................................................................................59
24Solarsettings...............................................................................................................................................60
24.1SolarEnergysettings...................................................................................................................................63
25Accumulatorsettings...................................................................................................................................64
26SystemControlling.......................................................................................................................................66
26.1Cascadesettings.........................................................................................................................................68
26.2ExistingBoiler..............................................................................................................................................71
27Pellematicsettings.......................................................................................................................................73
27.1Measuringvalues.........................................................................................................................................73
27.2Ignitionsettings............................................................................................................................................73
27.3Fullpowersettings.......................................................................................................................................74
27.4RunOnTimesettings...................................................................................................................................75
27.5OutputSettings............................................................................................................................................76
27.6De-ashingsystemsettings............................................................................................................................76
27.7Boilercleaning.............................................................................................................................................77
27.8Washing......................................................................................................................................................78
27.9Settings.......................................................................................................................................................79
27.10BoilerControlledPump...............................................................................................................................80
27.11FRTController...........................................................................................................................................81
27.12NegativeDraft............................................................................................................................................82
28HeatingMainPump.......................................................................................................................................83
29Generalsettings...........................................................................................................................................84
29.1SensorAdjust..............................................................................................................................................84
29.2OutputTest..................................................................................................................................................85
29.3Factorysetting.............................................................................................................................................85
29.4USB............................................................................................................................................................86
30Appendix......................................................................................................................................................87
30.1Calibration...................................................................................................................................................87
30.2Connectionplan...........................................................................................................................................89
30.3Wiringdiagrams...........................................................................................................................................93
30.4CablespecicationPelletronicTouch............................................................................................................95
30.5Hydraulicconnectingdiagrams.....................................................................................................................96
30.6Defaultvaluesandsettings.........................................................................................................................103
OperatingmanualPelletronicTouchE1389EN2.0

DearCustomer
5
1DearCustomer
ÖkoFENisEurope’sleadingspecialistinpelletheating.
Prociency,innovationandqualitycombined.ThisisthetraditiononwhichÖkoFENshapesthefuture.
WeareverypleasedthatyoutoohavedecidedtopurchaseaproductfromÖkoFEN.
•Thisinstructionmanualisintendedtohelpyouoperatetheproductsafely,properlyandeconomically.
•Pleasereadthisinstructionmanualrightthroughandtakenoteofthesafetywarnings.
•Keepalldocumentationsuppliedwiththisunitinasafeplaceforfuturereference.
Pleasepassonthedocumentationtothenewuserifyoudecidetopartwiththeunitatalaterdate.
•Pleasecontactyourauthoriseddealerifyouhaveanyquestions.
ÖkoFENattachesgreatimportancetothedevelopmentofnewproducts.OurR&DDepartmentrepeatedlychallenges
theeffectivenessoftried-and-testedsystemsandworkscontinuouslyonimprovements.Inthisway,wesecureour
technologicaladvantage.Wehavealreadyreceivedmanynationalandinternationalawardsforourproducts.
AllourproductscomplywithEuropeanstandardsinrespectofquality,efciencyandemissions.
E1389EN2.0OperatingmanualPelletronicTouch

Useonlyforthepurposeintended
6
2Useonlyforthepurposeintended
ThePellematicpelletheatingsystemisdesignedtoheatwaterforcentralorotherindirectheatingsystemsandhotwater
supplyforbuildings.ItisnotpermissibletousethePellematicpelletheatingsystemforanyotherpurpose.Reasonable
foreseeableinadvertentusesforthePellematicheatingsystemarenotknown.
ThePellematiccomplieswithallrelevantdirectives,guidelines,regulationsandstandardsaspartofthedeclarationof
conformitythatappliestothistypeofequipment.
EUguidelinesDesignation
2006/42/EGGuidelinesformachines
2006/95/EGLowvoltageguidelines
2001/95/EGProductsafetyguideline
2004/108/EGGuidelineforelectromagneticcompatibilityofcomponents(EMVG)
Thefollowingharmonisedstandardshavebeenapplied:
StandardsDesignation
EN303–5BoilersPart5
EN14961–2Pelletsfornon-industrialuse
ThefollowingAustrianstandards,guidelinesandspecicationshavebeenapplied:
StandardsDesignation
TRVBH118Technicaldirectiveonreprevention
OperatingmanualPelletronicTouchE1389EN2.0

Typesofsafetywarningsign
7
3Typesofsafetywarningsign
Thewarningsignsusethefollowingsymbolsandtext.
Typesofsafetywarningsign
1.Riskofinjury
2.Consequencesofrisk
3.Avoidingrisk
1.Riskofinjury:
Danger-indicatesasituationthatcouldleadtodeathor
life-threateninginjury.
Warning-indicatesasituationthatcouldlead
life-threateningorseriousinjury.
Caution-indicatesasituationthatcouldleadtoinjury.
Note-indicatesasituationthatcouldleadtoproperty
damage.
2.Consequencesofrisk
Effectsandconsequencesresultingfromincorrect
operation.
3.Avoidingrisk
Observingsafetyinstructionsensuresthattheheating
systemisoperatedsafely
E1389EN2.0OperatingmanualPelletronicTouch

Pelletronicheatingcontrollerandoperating
devicewithtouchscreen.
8
4Pelletronicheatingcontrollerandoperatingdevicewithtouch
screen.
Theheatingcontrollercontrolstheheatingsystemandregulatestheoperatingmodes,heatingcircuits,domestichot
water,accumulator,existingboilerandthesolarthermalsystem.Allinputsandoutputsareconnectedwiththeheating
controller.Visualisationandoperationoftheheatingcontrollerisdonewiththeoperatingdevicewithtouchscreen.It
displaysallmenuoptionsandmeasuringvaluesoftheheatingcontroller.Allspecicsettingsoftheheatingsystemis
donewiththeTouchoperatingdevice.
4.1OperatingDevicewithTouchscreen
TheTouchoperatingdeviceismountedonthecontrolboardofPellematic.The4.7"colordisplayissurroundedby
adesignfoilwithlogo.ApplyngerpressuretooperatetheTouchscreen.
4.2Openingwindow
Thetouchpanelisdarkwheninstandbymode.Assoonasthesurfaceofthescreenistouched,itlightsupand
displaystheopeningwindow.
1Boilertemperature
2Outsidetemperature
3Hour
4Theiconhousetakestothemainmenu.
5Chimneysweep
6Favorite2
7Favorite1
OperatingmanualPelletronicTouchE1389EN2.0

Pelletronicheatingcontrollerandoperating
devicewithtouchscreen.
9
4.3Chimneysweep
ThefunctionChimneysweepisonlyforchimneysweeperorauthorisedservicetecnicians.Itisusedforexhaust
gasmeasurement.
MenuChimneysweepisintheopeningwindow.
Afterselectingthechimneysweepfunctionitwill
querywhethertoexecute.Ifyesthenpressthetick
box.
•Boilertemperaturesetis60°Cforthetotalrunning
timeof30minutes.
•Itdisplaystheactualboilertemperatureanddelay
time.
•ChimneysweepisstoppedwithCancel.
E1389EN2.0OperatingmanualPelletronicTouch

Pelletronicheatingcontrollerandoperating
devicewithtouchscreen.
10
4.4Usercontrolsandtheirfunction
1.Howtonavigatetotherightmenu
Navigation-icons
Icon-
view
chosen
Icon-
view
Ifyoutouchanicon,thaticonturnsgreen.Thisindicatesthattheitemisselectedand
enablesthatfunction.
Theyellowhomesymboltakesyoudirectlytothemainmenu.
Thehorizontalarrowtakesyouonestepback.
Withthebluedownarrowyougettoadditionallinesofinformationonthisitem.(Down
-scrolldown).
Withtheblueuparrowyougettoadditionallinesofinformationonthisitem.(Topof
page-scrollup)
Navigatetotherespectivemenuitem.
Oncetherespectiveitemhasbeenselectedthenparametersmaybeset.Itwilldisplay
eitheranumericortextkeypad.
2.Numerickeyboard
a.Nameofparameter
b.Valueofparameterwithunit
c.Min/maxvalue–Valuesoutsidethisrange
arenotaccepted.
d.Deleteinputofnumbers–touchonceto
deleteoneplace.
e.Cancel–Youreturntothemenuitem.Input
ofanewvaluewasnotaccepted.Theoriginal
valueisthenrestored.
f.Helpfunction–inactive
g.Conrm
h.Numerickeyboard–usedtoentervalues
withintheMin-Maxrange.
OperatingmanualPelletronicTouchE1389EN2.0

Pelletronicheatingcontrollerandoperating
devicewithtouchscreen.
11
3.Timeanddateblock
a.Nameofparameter
b.Adjustabletimeordate
c.Cancel
d.Helpfunction–inactive
e.Conrm
WiththePlusMinusblockyouchangenumbers.
4.Textselection
a.Nameofparameter
b.Statustexts
Thenumberofstatustextsdependsonthe
parameter.
Chooseastatustext.Thesetupmenucloses
automaticallyandthechosenstatustextis
displayedinthemenu.
Note
Althoughascrolldownmenuisopen,thenavigation/parametericonsbehindarestillactiveandcanbeused.
E1389EN2.0OperatingmanualPelletronicTouch

Pelletronicheatingcontrollerandoperating
devicewithtouchscreen.
12
4.5MainMenu
Inthemainmenuallsubmenusaredisplayed.Presstheiconrequiredtoaccessthatprogramme.
MenunavigationofPelletronicTouch
OperatingmanualPelletronicTouchE1389EN2.0

Mode
13
5Mode
InthemenuitemModesyoucanseetheoperatingmodeoftheheatingsystem,heatingcircuits,domestichotwater
andsolar.
ThemenuitemModeisintheMainmenu.
Overviewoftheoperatingmodes
•HeatingPlant
•Heatingsystem1-6.
•Domestichotwater1-3
•Solar1–3
Choosetheoperatingmodeandsetaccordingly.
OPERATINGMODESSYSTEM
OffTheadjustedoperatingmodeoftheheatingcircuitsandDHWisinactive.
Thefrostprotectionfunctionisactive.
AutoTheadjustedoperatingmodeoftheheatingcircuitsandDHWisactive.
Thefrostprotectionfunctionisactive.
DomestichotwaterTheadjustedoperatingmodeoftheDHWisactive.
Theadjustedoperatingmodeoftheheatingcircuitsisactive.
Thefrostprotectionfunctionisactive.
Theoperatingmodeheatingcircuits,domestichotwaterandsolararedescribedintherespectivechapters.
E1389EN2.0OperatingmanualPelletronicTouch

MeasuringValues
14
6MeasuringValues
InthemenuitemValuesyoucanviewcurrentsettingsorsetnewvaluesfortheheatingcircuit,domestichotwater,
accumulatororsolar.
ThemenuitemMeasuringValuesisintheMain
menu.
Selecttheappropriatesubmenu.
InthemenuitemHeatingcircuityouseeallactual
andsetvaluesoftheheatingcircuitsinyourheating
system.
InthemenuitemDomestichotwateryouseeall
actualandsetvaluesoftheDHWproduction.
InthemenuitemSolaryouseeallactualandset
valuesofthesolarthermalsystem.
InthemenuitemAccumulatoryouseeallactualand
setvaluesoftheaccumulator.
InthemenuitemSystemyouseeallactualandset
valuesoftheoverallheatingsystem.
InthemenuitemAllocationyouseewhich
heatingcircuitsareallocatedtotheboilerortothe
accumulatores.
OperatingmanualPelletronicTouchE1389EN2.0

MeasuringValues
15
SystemStatusisanoverviewofthewholeheating
system.
E1389EN2.0OperatingmanualPelletronicTouch

HeatingCircuit
16
7HeatingCircuit
HeatingCircuitcontainsallrelevantparametersandsettings.Itcanoperateupto6heatingcircuits.
HeatingCircuitisintheMainmenu.
HeatingCircuithasfollowingmenuitems:
•Mode
•RoomTempHeating
•RoomTempSetback
•TimeAllocation
•Values
•Time1
•Time2
•Party
•Vacation
•HeatingCurve
ModeOffOnlythefrostprotectionfunctionisactive.
AutoTheboilerstartsheatingautomaticallyaccordingtothesetroom
temperature.
HeatingTheboilerheatsconstantlyaccordinglytotheSetroomtemperature.
SetbackTheboilerheatsconstantlyaccordinglytotheSetbackroom
temperature.
Theoperatingmodeoftheheatingcircuitscanonlybechangediftheplantoperatingmode
issettoAUTO.
Theadjustedheatinglimitsandmaximumowtemperaturesareusedinalloperating
modes.
RoomTempHeatingChooseyourroomtemperature(Temperaturewithintheheatingtimes).
RoomTempSetbackChooseRoomT empSetback(=Minimumtemperaturebeyondtheheatingtimes).
TimeAllocationActivateTime1(=Timeprogramme1)andTime2.
OperatingmanualPelletronicTouchE1389EN2.0

HeatingCircuit
17
7.1MeasuringvaluesHeatingcircuit
MeasuringvaluesHCisintheMainmenu.
Thisdisplaysallcorrespondingheatingcircuitvalues:
•Actualvalue
•Setvalue
•Inputs(sensores)
•Outputs(pumps,mixerandmotors)
7.2TimeprogrammeHeatingcircuit
Theheatingcircuitprogrammeisusedtosettheheatingtimes.
Time1(=Timeprogramme1)andTime2areinthemenuHeatingcircuit.
1
SelectTime
programme1
6
Mo-Frwereassigned
heatingtimes
Withyougettothe
remainingdaysSa-Su.
2
Selecttheheating
days.
Theactivateddaysare
displayedingreen.
7
Sa-Suwereassigned
toheatingtimes.
3
Entertheheatingtimes
fortheseheatingdays
(Mo-Th).
8
Withand
youswitchbetween
theheatingblocks.
Youcanactivateor
deactivateheating
daysintheheating
block.
E1389EN2.0OperatingmanualPelletronicTouch

HeatingCircuit
18
4
Theheatingtimesfor
Mo-Thareassigned.
Withyouassign
thedaysheatingtimes
further.
9
Withyousetallthe
heatingtimesintheline
andbelowto0.
5
Fridayisactivated
andheatingtimes
assigned.
10
Gobackwith.
SelectTime2.
Foreachcircuitaretwo
timeprogrammes.You
canselecttwo-time
programs.Inthemenu
itemTimeAllocation
youcanactivateTime
programme1or2.
OperatingmanualPelletronicTouchE1389EN2.0

HeatingCircuit
19
7.3Party
Thepartyfunctionextendstheheatingtimeonce,withoutchangingtheheatingtimes.
PartyisintheMainmenu.
Thepartyfunctionisbasicallyinactive.Enterthe
requiredstoptimethattheroomshouldbeheated
until.ActivatethePartyfunction.
Theheatingtimeisextendeduptotheindicated
time.Thenthepartyfunctiondeactivatesitself
automatically.
7.4Vacation
Theholidayprogrammecancelstheheatingtimesandheatsfortheenteredperiodonthesettemperaturelevel.
VacationisintheMainmenu.
Entertheroomtemperatureonwhichinyourabsence
thebuildingshouldbeheated.Enterthedeparture
(starttime)andreturn(nishdate)andactivatethe
vacationprogramme.
Note
Toreturntoanalreadytemperatebuilding
youshouldenterthedaybeforeyourreturn
asthenishdate.
E1389EN2.0OperatingmanualPelletronicTouch

HeatingCircuit
20
7.5HeatingcurveandHeatinglimits
Startingupforthersttime,theauthorisedtechnicaladviseradjuststheheatingcurve,thebasepointandtheheating
limitsonthebuildingsituationandthehydraulics.IftheSetroomtemperatureisnotreachedorexceeded,adjustthe
heatcurvewiththeowtemperaturesaccordingtooutsidetemperatures.
HeatingcurveisinthemenuHeatingcircuit.
Heatingcurve0.0–4,0
Theheatingcurvedescribesthecombination
betweenoutdoortemperatureandtheassociatedow
temperatureforaheatingcircuit.
Basepointadjustablefrom20-45
Withthechangetheofbasepoint,youprovidea
parallelshiftoftheheatingcurve.
Hlimitheating
Iftheaverageoutsidetemperatureishigherthanthe
settemperature,theheatingcircuitswitchesoffinthe
heatingmode.
Hlimitsettemperature
Iftheaverageoutsidetemperatureishigherthanthe
settemperature,theheatingcircuitswitchesoffinthe
Setbackmode.
OperatingmanualPelletronicTouchE1389EN2.0