REGULATED
MEDIUM
VOLTAGE
OLTRONIX
POWER
SUPPLIES
GENERAL
These
19"
Rack
-
models
are
multiple
voltage
high
stability
D.
C.
Power
Supplies
for
uni-
v
ersal
use,
when
D.
C.
vo
ltage
of
excellent
regulation
is
needed.
The
y .
are
co
nservatively
constructed
wi
th
electron
tube
regulation.
The
amplifier
heaters
in
the
major
unit,
0-500
V,
are
fed
wi
th
regulated
D .
C.
current
providing
lm-
proved
regulation
and
low
ripple.
Regulated
Output
Ripple
Regulation
Model
mV
Line
Load
No.
V
rnA
r.
m.
s.
mV mV
A
0-500
250
l
40
200
B
-1
50
100
0,5
10
150
LS120R
C
0--150
h i g h
im
p.
10
-
D 0
-170
100
2
300
600
A
0-500
500
l
40
250
LS122R
B
-1
50
100
0,5
15
150
C 0
--1
50
h i g h i m
p.
15
-
A 0
-5
00
250
l
40
200
B
-1
50
100
O,
5
10
150
LS124RS
D
0-170
100
l
300
600
E O
-l
70
100
l
300
600
OUTPUTS
A.
Continuously
variable
in
two
ranges
0-
230
Vand
230
-
500
V.
B .
Fixed
voltage,
connected
to
A.
C.
High
impedance,
continuously
va
riable,
derived
from
B.
D.
Continuously
va
riable,
iso
l
ated
from
A,
B,
C
and
E.
E .
Continuously
va
riable,
isolated
from
A,
B,
C
and
D.
Binding
posts
are
provided
on
the
front
panel,
in
addition
a
connector
is
located
at
the
rear.
This
connector
also
inc1udes
terminals
for
remote
programming
.
INPUT
VOLTAGE
220
V
50-60
Hz
may
fluctuate
bet
wee
n
200
V
and
240
V.
Other
input
vo
lta
ge
and
frequency
on
spe
cial
r
eque
s
t.
SWITCHES
Separate
switches
are
used
for
"LINE
ON"
and
"D
.
C.
ON".
LS120R
and
LS122R
has
one
"D.C.
ON"
switch
for
all
D.C.
output
termi-
nals,
LS124R
has
one
swi
tch
for
output
A
and
B
and
one
for
D
and
E.
SVENSKA AB OLTRONIX -Jämtlandsgatan 125 -
LS120R
LS122R
LS124R
Heater
Meters
Di
mensions
Weight
6,3V
for
A,
50
Hz
D&E
H W D
kgs
6A
t
wo
132
19"
350
15
2A
V+A
6A
two
132
19"
350
19
6A
V+A
6A
one
221
19"
348
17
2A
V/ A
REGULATION
The
specifications
above
refer
to:
a
10
0/'0
line
voltage
variation
and
a
no
load
to
full
load
c
hange.
METERS
One
volt
-
and
one
amp-meter
can
be
switched
for
measurin
g
voltage
and
current
from
out
-
put
A,
D
and
E.
ADJUSTABLE
PROTECTION
The
different
outputs
are
ordinarily
fused
with
thermal
fuses,
but
on
special
order
the
output
A
can
be
provided
with
a
transistori
zed
protecting
circuit
adjustable
w
ithin
10-100
%
of
ma
x.
current.
This
feature
is
recognized
by
the
l
et
ter
S
af
ter
the
model
number,
as
in
LS
120
RS.
REMOTE
PROGRAMMING
The
output
A
on
LS
120
R
and
LS
122
R
can
be
controlled
externallyby
connecting
a
resistor
bet
ween
the
connectors
E
and
F
in
the
rear
contact.
The
programming
constant
is
200
ohms
per
volt,
and
it
is
possible
to
cover
the
whole
voltage
range
w
ithout
switching
or
other
adjustment,
if
a
reduction
of
the
output
curr-
ent
is
permissible.
This
is
described
In
detail
in
our
manual.
Stockholm-Vällingby -Sweden • Phone
870330
OLTRONIX-NEDERLAND N. V. - Vredenburgweg 7 - Hoogezand -Holland -Phone: 05980·
2301
Febr.
-
66