Operation
Operating elements (see photo of front panel)
BAND - band selector switch (in MHz)
TUNE - Anode capacitor for tuning, tuning of higher frequencies to "0",
lower frequencies to „100“.
LOAD -Output capacitor tunes antenna load resistance to amplifier.
Capacity is low at „0“ and high at "100" on the scale.
OFF - You switch off the amplifier by pressing this button.
ON - You switch on the amplifier by pressing this button.
Heating of tube is on and after 3min of delay the amplifier will be
ready for operation.
OPR/STBY - „OPERATE“you will be ready for operation.
At STBY, if WAIT-LED is on or the amplifier is off your transceiver is in
bypass-mode directly connected to antenna. Maximum 400 Watts !
RF OUTPUT - Bar graph –shows output power .
REFLECTED POWER -Bar graph –shows reflected power of the antenna. 350W
maximum or amplifier switches to STANDBY-mode
Ig2 bargraph –measerus the currency of the second grid in the range from -20mA to
+80mA
HV/IP/TUNE bargraph –measure the anode voltage, anode currency or tuning of the amplifier
TUNING
The OM2000 HF amplifier is operated in class AB. Thus it’s possible to obtain a maximum
output power at an excellent linearity. For this purpose the amplifier has to be tuned carefully.
The operation of a mistuned PA will cause malfunctions, the increase of grid current (the GRID-
MAX-LED will light up) and problems with TVI/BCI.
The grid-current is shown with 2 LED diodes. It’s normal if the green LED is flashing or may be
shining a little bit during peak operation. If you overload the amplifier the output power increases the
grid current at very small rates and the red GRID-MAX-LED is shining and the safety devices switch
the PA to STBY. You must decrease the output power.
In SSB you will have a good output power if the green LED lights up a bit. The current of screen
grid is measured and shown in a Bar graph indicator. The amplifier has to be tuned in such a
way that the current is between - 20 mA to +50 mA. At currents beyond these values the
operating point will be shifted and IM-products will be rapidly increased.If a value of + 70mA is
exceeded, the safety devices will switch the amplifier to STBY mode.