Page : 3
INSTALLATION
PRECAUTIONS.- Theinstallationandthe
future use of this unit
must be done by suit-
able qualified person-
nel.TheunithasnotAC
(mains)switch,itwillbe
inoperationassoonas
power is connected.
The installation must
incorporateanexternalmainswitch.
The unit has a protection fuse incorporated on the AC socket, if it is
necessarytochangeor replace,usethetimelagfuseaccordingIEC
127/2andthevaluesindicatedbelow.
200 mA when the unit is operating at 230 Vac
400 mA when the unit is operating at 115 Vac.
Install also the necessary devices to protect the operator and the
process when using the unit to control a machine or process where
injurytopersonnelordamagetoequipmentorprocess,mayoccuras
a result of failure of the unit.
Seeparagraph8,WIRINGandparagraph10,CONFIGURATIONand
checkthatalljumpersareonthe correct position.
SAFETY PRESCRIPTIONS.-
TheunithasbeendesignedandtestedunderEN-61010-1rulesand
isdeliveredingoodcondition.Thisopera-
tor's manual contains useful information
for electrical connections. Do not make
wiring signal changes or connections
whenpoweris
applied to the unit. Make signal connec-
tionsbeforepowerisappliedand,ifrecon-
nection is required, disconnect the AC
(mains) power before such wiring is at-
tempted.
Installtheunitin placeswithagoodventilationtoavoidtheexcessive
heating.Andfarfromelectricalnoisesourceormagneticfieldgenera-
torssuchaspower relays, electricalmotors,speedcontrolsetc...
The unit cannot be installed in open places. Do not use until the
installationisfinished.
POWERSUPPLY.-
Thepowersupplymustbeconnectedtotheadequateterminals (see
theconnectioninstructions).Thecharacteristicsofthepowersupply
areshowedonthelabelontherearpart.Pleasemakesurethattheunit
is correctly connected to a power supply of the correct voltage and
frequency.
Donotuseotherpowersupplyotherwisepermanentdamagemaybe
causedtotheunit.
Donotconnecttheunittopowersourcesheavilyloadedortocircuits
which power loads in cycle ON-OFF or to circuits which power
inductiveloads.
SIGNALWIRING.-
Certainconsiderationsmustbegivenwheninstallthesignalinputand
control wires. If the wires are longs can act like an antenna and
introducetheelectrical noisetothe unit,therefore:
Donotinstallthesignalinputorcontrolwiresinthesameconduitwith
power lines, heaters, solenoids, SCR controls etc....and always far
fromtheseelements.
When shielded wires are used, connect the shield to the common
terminalandleaveunconnectedtheotherendoftheshieldanddonot
connecttothemachineground.
1.- IMPORTANT SAFETY CONSIDERATIONS
SAFETY CONSIDERATIONS
PRESCRIPTIONS.-
Before starting any operation of adjustment, replacement,
maintenanceorrepair,theunitmustbedisconnectedfromanykind
ofpowersupply.
Keeptheunitclean,toassure goodfunctioning andperformance.
Use for it a clean and humid rag. Do not use for the frontal lens
abrasiveproducts,solvents,alcohol,etc...becauseitstransparence
couldbedamagedand this may causedifficultyfora correct vision
ofthereading. Topreventelectricalor
fire hazard, do not ex-
posetheunittoexces-
sivemoisture.
Donotoperatetheunit
inthepresenceofflam-
mablegasesorfumes,
suchasenvironment
constitutes a definite
safetyhazard.Theunit
isdesignedtobe mounted inametalpanel.
Iftheunitshowssignsofdamage,orisnotabletoshowtheexpected
measures, or has been stored in a bad conditions or a protection
failurecanoccur,thendonotattempttooperateandkeeptheunitout
ofservice.
IN CASE OF FIRE
1.- Disconnect the unit from the power supply.
2.-Givethealarmaccordingtothe local rules.
3.-Switchoffalltheairconditioningdevices.
4.-Attackthefirewith carbonicsnow,donotuse waterinanycase.
WARNING : In closed areas do not use systems with
vaporizedliquids.
CONNECTIONS
All wiring connections are made using push-in and Sub-D cable
connectors.
There is a separate connector block for power supply and
input&controlsignal.Pleasemakesurethateachconnectorblockis
connectedontheadequateplace.
Thewirecrosssection recommendedforpowersupply is2.5mm2.
PANEL MOUNTING
Verifythatthepanelcut-outiscorrectlyaccordingtothedimensions
indicated on page 13 with a minimum depth of 150 mm. (5.9").
Install the fixation pieces in the lateral guides of the unit by its rear
partandthenturnthescrew firmlyagainstthepanel,untiltheunitis
totallyholdon.
Seeparagraph12 onpage13.