Everypersoninvolvedwiththeinstallation,operationandmaintenanceofthisdeviceneedsto
● bequalified
● followtheinstructionsofthismanual
● considerthismanualtobepartofthetotalproduct
● keepthismanualfortheentireservicelifeoftheproduct
Passthismanualontoeveryfurtherowneroruseroftheproduct.
DownloadthelatestversionoftheusermanualfromtheOmniSistemwebsite.
Foryourownsafety,pleasereadthisusermanualcarefullybeforeyouinitiallystarttheproduct.
INTRODUCTION
Thank you for choosing an OmniSistem product. OmniSistem is a wholesaler of a large variety of lighting, sound,
truss, and effects. Since 1986, we have been providing quality and affordable lighting products to North America.
Weareconfidentthatourexcellentproductswillmeetyourexpectations.
Includedinthisboxyouwillfind:
1. OnyxPro75
2. UserManual
3. OmegaHolderwithQuickLockFastener
4. PowerSupplyCable
5. SafetyCable
SAFETYINSTRUCTIONS
This device left our facility after a thorough QC check. In order to maintain excellent condition and to ensure a safe
operation, it is absolutely necessary for the user to follow the safety instructions and warnings detailed in this user
manual.
Important:
Damagescausedbythedisregardofthisusermanualarenotsubjecttowarranty.Thedealer
willnotacceptliabilityforanyresultingdefectsorproblems.
2 of 18

(SafetyInstructionsContinued)
●Minimum distance from flammable materials to all surfaces of the unit is 0.3m (11.81”).
●If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it
on immediately. The arising condensation water might damage your device. Leave the device switched off
until it has reached room temperature.
●Please make sure that there are no obvious transport damages. Should you notice any damages on the A/C
connection cable or on the casing, do not take the device into operation and immediately consult your local
dealer.
●This device falls under Protection Class I. The power plug must only be plugged into a Protection Class I outlet.
The voltage and frequency must exactly be the same as stated on the device. Wrong voltages or power
outlets can lead to the destruction of the device and to mortal electrical shock.
●Always plug in the power plug last. The power plug must always be inserted without excessive force. Make
sure that the plug is tightly connected with the outlet.
●Never let the power cord come into contact with other cables! Handle the power cord and all connections with
the mains with caution! Never touch them with wet hands, as this could lead to mortal electrical shock.
●Never modify, bend, strain mechanically, put pressure on, pull or heat up the power cord. Never operate next
to sources of heat or cold. Disregarding this can lead to power cord damages, fire or mortal electrical shock.
●The cable insert or the female part in the device must never be strained. There must always be sufficient cable
to the device. Otherwise, the cable may be damaged which may lead to mortal damage.
●Make sure that the power cord is never crimped or damaged by sharp edges. Check the device and the power
cord from time to time.
●Do not connect more than 8 units together in a single power chain.
●If extension cords are used, make sure that the core diameter is sufficient for the required power consumption
of the device. All warnings concerning the power cords are also valid for possible extension cords.
●Always disconnect from the power source, when the device is not in use or before cleaning it. Only handle the
power cord by the plug. Never pull out the plug by tugging the power cord. Otherwise, the cable or plug can be
damaged leading to mortal electrical shock. If the power plug or the power switch is not accessible, the device
must be disconnected via the mains.
●If the power plug or the device is dusty, the device must be taken out of operation, disconnected and then be
cleaned with a dry cloth. Dust can reduce the insulation which may lead to mortal electrical shock. More
severe dirt in and at the device should only be removed by a specialist.
●There must never enter any liquid into power outlets, extension cords or any holes in the housing of the
device. If you believe even a minimal amount of liquid may have entered the device, it must immediately be
disconnected. This is also valid, if the device was exposed to high humidity. Also if the device is still running,
the device must be checked by a specialist if the liquid has reduced any insulation. Reduced insulation can
cause mortal electrical shock.
●There must never be any objects entering into the device. This is especially valid for metal parts. If any metal
parts like staples or coarse metal chips enter into the device, the device must be taken out of operation and
disconnected immediately. Malfunction or short-circuits caused by metal parts may cause mortal injuries.
3 of 18

Keep away children and amateurs! Never leave this device running unattended.
OPERATINGPROCEDURES
Thisdeviceisamovingheadlightforcreatingdecorativeeffects.Thisproductisonlyallowedtobeoperatedwith
analternatingvoltageof100240V,50/60Hzandwasdesignedforindooruseonly.
Thisdeviceisdesignedforprofessionaluse,e.g.onstages,inclubs,bars,theatres,etc.
Lightingeffectsarenotdesignedforpermanentoperation.Consistentoperationbreakswillensurethatthedevice
willserveyouforalongtimewithoutdefects.
Donotshakethedevice.Avoidbruteforcewheninstallingoroperatingthedevice.
Neverliftthefixturebyholdingitattheprojectorhead,asthemechanicsmaybedamaged.Alwaysholdthe
fixtureatthetransporthandles.
Whenchoosingtheinstallationspot,pleasemakesurethatthedeviceisnotexposedtoextremeheat,moisture
ordust.Thereshouldnotbeanycableslyingaround.Pleasemakesurethattheunitcannotbetouchedor
bumped.
Thisdevicemustneverbeoperatedorstockpiledinsurroundingswherewatersplash,rain,moistureorfogmay
harmthedevice.Moistureorveryhighhumiditycanreducetheinsulationandleadtomortalelectricalshocks.
Whenusingsmokemachines,makesurethatthedeviceisneverexposedtothedirectsmokejetandisinstalled
inadistanceof0.5metersbetweensmokemachineanddevice.Theroommustonlybesaturatedwithanamount
ofsmokethatthevisibilitywillalwaysbemorethan10meters.
Theambienttemperaturemustalwaysbebetween15°Cand+45°C.Keepawayfromdirectheat(particularlyin
cars)andheaters.
Therelativehumiditymustnotexceed50%withanambienttemperatureof45°C.This
devicemustonlybeoperatedinanaltitudebetween20and2000moversealevel.
Neverusethedeviceduringthunderstorms.Overvoltagecoulddestroythedevice.Alwaysdisconnectthedevice
duringthunderstorms.
Thissymboldeterminestheminimumdistancefromlightedobjects.Theminimumdistance
betweenlightoutputandtheilluminatedsurfacemustbemorethanthisvalue.
Thehousingmustnevertouchsurroundingsurfacesorobjects.
Makesurethattheareabelowtheinstallationplaceisclearwhenrigging,deriggingorservicingthefixture.
Foroverheaduse(mountingheight>100cm),alwaysfixthefixturewithanappropriatesafetycable.Fixthesafety
cableatthecorrectfixationpointsonly.Thesafetycablemustneverbefixedatthetransporthandles!
Onlyoperatethefixtureafterhavingcheckedthatthehousingisfirmlyclosedandallscrewsaretightlyfastened.
ThemaximumambienttemperatureTa=45°Cmustneverbeexceeded.
Operatethedeviceonlyafterhavingbecomefamiliarizedwithitsfunctions.Donotpermitoperationbypersonsnot
qualifiedforoperatingthedevice.Mostdamagesaretheresultofunprofessionaloperation!
Pleaseusetheoriginalpackagingifthedeviceistobetransported.
Pleaseconsiderthatunauthorizedmodificationsonthedeviceareforbiddenduetosafetyreasonsand
willvoidyourwarranty.
Neverremovetheserialbarcodefromthedeviceasthiswouldvoidthewarranty.
Ifthisdevicewillbeoperatedinanywaydifferenttotheonedescribedinthismanual,theproductmaysuffer
damagesandtheguaranteebecomesvoid.Furthermore,anyotheroperationmayleadtodangerslikeshort
circuit,burns,electricshock,crashing,etc.
4 of 18

PRODUCTFEATURES&SPECIFICATIONS
Light
● Lightsource:75WWhiteLED
● Lamplife:60,000hours
● LuminousFlux:6400lumen,6990lux@2.5m
● Control:Remoteon/offviaDMX
● Ballast:switchingmodepowersupply
● Beamangle:13°to18°
X/Y
● Pan:630°(4.0sec)or540°(3.58sec),Tilt:265°(2.8sec)
● 16bitresolution
● Autorepositioning
Colors
● 8+open,interchangeable,indexableandbidirectionalrainboweffect
● Colorbounce
Gobos
● Outside¢23mm,inside¢18mm
● 7+open,custominterchangeablepositionforrotatinggobowheel
● Realindexableandgoboshaking
● Distinctivegoboanimationeffect
Features
● DMXchannels:11/14
● Colorwheel:8+1colors
● Staticgobowheel:7+1gobos
● Manualzoomfrom13°to18°
● Motorizedfocus
● Fullrange0100%dimmer
● Variousstrobe
● 3facetprism
● SoftwareupgradeviaDMX
● HibernationwhenlostDMXforpresettime
● Fanspeedautochangeaccordingtotemperature
Display
● LEDDisplay
● Flip
● BackupcommunicatingIC
Power
● Maxpowerconsumption:160W
● Powersupply:Electronicautoranging
● Inputvoltagerange:100–240V,5060Hz
5 of 18

OVERVIEW
(1) Objectivelens
(2) Arm
(3) Base
(4) Handle
(5)Wirelessindicator
(6) Display
(7) MODE/ESC
(8) DownButton
(9) UpButton
(10) Enterbutton
(11) 3PINDMXinputsocket
(12) 3PINDMXoutputsocket
(13) Powerinput
(14) Poweroutput
6 of 18

INSTALLATION
Inserting/ExchangingGobos
Ifyouwishtouseothergobos,orifgobosaretobeexchanged,pleasefollowtheinstructionsbelow:
Removethefixationringwithanappropriatetool.Removethegoboandinsertthenewgobo.Pressthefixation
ringtogetherandinsertitinfrontofthegobo.
Rigging
The installation of the projector has to be built and constructed in a way that it can hold 10 times the weight for 1
hourwithoutanyharmingdeformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net. This
secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main
attachmentfails.
When rigging, derigging or servicing the fixture staying in the area below the installation place, on bridges, under
highworkingplacesandotherendangeredareasisforbidden.
The operator needs to make sure that safetyrelated and machine technical installations are approved by an expert
beforetakingintooperationforthefirsttimeandafterchangesbeforetakingintooperationanothertime.
The operator needs to make sure that safetyrelated and machine technical installations are approved by an expert
aftereveryfouryearsinthecourseofanacceptancetest.
The operator needs to make sure that safetyrelated and machine technical installations are approved by a skilled
persononceayear.
7 of 18

Procedure:
Theprojectorshouldbeinstalledoutsideareaswherepersonsmaywalkbyorbeseated.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to)
calculating working load limits, installation material being used, and periodic safety inspection of all installation
material and the projector. If you lack these qualifications, do not attempt the installation yourself, but instead use
aprofessionalstructuralrigger.Improperinstallationcanresultinbodilyinjuryand/ordamagetoproperty.
Theprojectorneedstobeinstalledoutofreachofpeople.
If the projector shall be lowered from the ceiling or high joists, professional trussing systems need to be used. The
projectormustneverbefixedswingingfreelyintheroom.
Caution: Projectors may cause severe injuries when crashing down! If you have doubts concerning the safety of a
possibleinstallation,doNOTinstalltheprojector!
Before rigging make sure that the installation area can hold a minimum point load of 10 times the projector's
weight.
Theunitcanbeplaceddirectlyonthestagefloororriggedinanyorientationonatrusswithoutalteringits
operationcharacteristics(seethedrawing).
Thefixturebaseenablesmountingintwo
ways.
Foroverheaduse(mountingheight>100cm),
alwaysinstallanappropriatesafetybond.
Pleasenote:foroverheadrigginginpublicor
industrialareas,aseriesofsafetyinstructions
inthismanualneedtobefollowed.The
operatormustinformthemselvesonthe
currentsafetyinstructionsandconsiderthem.
8 of 18

Themanufacturercannotbemadeliablefordamagescausedbyincorrectinstallationsorinsufficientsafety
precautions!
Installthesafetybondbyinsertingthequicklinkintheholeonthebottomofthebase.Pullthesafetybondover
thetrussingsystem.Inserttheendinthequicklinkandtightenthefixationscrew.
Themaximumdropdistancemustneverexceed20cm.
Asafetybondwhichalreadyholdsthestrainofafallorwhichisdefectivemustnotbeusedagain.
ScrewtheclampviaaM12screwandnutontotheOmegaholder.
InsertthequicklockfastenersoftheOmegaholderintotherespectiveholeson
thebottomofthedevice.Tightenthequicklockfastenersfullyclockwise.
9 of 18

DMX512connection/connectionbetweenfixtures
Pleasenote,thestartingaddressdependsuponwhichcontrollerisbeingused.
OnlyuseaDMXcableand3pinXLRplugsandconnectorsinordertoconnectthecontrollerwiththefixtureor
onefixturewithanother.
OccupationoftheXLRconnection:
If you are using controllers with this occupation, you can connect the DMX output of the controller directly with
the DMX input of the first fixture in the DMX chain. If you wish to connect DMX controllers with other XLR
outputs,youneedtouseadaptercables.
BuildingaserialDMXchain:
Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture. Always
connectoneoutputwiththeinputofthenextfixtureuntilallfixturesareconnected.
Caution: At the last fixture, the DMX cable needs to be terminated. Plug the terminator with a 120Ωresistor
betweenSignal(–)andSignal(+)intheDMXoutputofthelastfixture.
10 of 18

ConnectionwiththeMains
Connectthedevicetothepowersourcewiththeenclosedpowersupplycable.
Theconfigurationoftheconnectioncablesisasfollows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Ground
Groundneedstobeconnected!
Ifthedevicewillbedirectlyconnectedwiththelocalpowersupplynetwork,adisconnectionswitchwitha
minimumopeningof3mmateverypolehastobeincludedinthepermanentelectricalinstallation.
The device must only be connected with an electric installation carried out in compliance with the IEC standards.
The electric installation must be equipped with a Residual Current Device (RCD) with a maximum fault current of
30mA.
Devicemustnotbeconnectedtodimmingpacks.
The device is equipped with a lockable power input connector. Plug in the power cord and turn it to the right until it
locks.Plugthepowercordintoagroundedelectricaloutletthatmatchestheratedvoltageofthemachine.
OPERATION
Withthepowerswitch,youcanswitchthedeviceonandoff.
Afterbeingconnectedtothepowersupply,thefixturestartsrunning.Duringthereset,themotorsaretrimmedand
thedeviceisreadytouse.
StandAloneoperation
IntheStandAlonemode,thedevicecanbeusedwithoutcontroller.
Disconnectthefixturefromthecontrollerandcalltheinternalprogram.
PleaserefertotheinstructionsunderControlBoard.
DMXControlledoperation
YoucancontroltheprojectorsindividuallyviayourDMXcontroller.EveryDMXchannelhasadifferentoccupation
withdifferentfeatures.TheindividualchannelsandtheirfeaturesarelistedunderDMXprotocol.
Addressing
TheControlBoardallowsyoutoassigntheDMXstartingaddress,whichisdefinedasthefirstchannelfromwhich
thefixturewillrespondtothecontroller.
If you set, for example, the address to channel 20, a fixture in 18 channel mode would use channels 20 to 38
forcontrol.
Pleasebesurethatyoudon’thaveanyoverlappingchannelsinordertocontroleachfixturecorrectlyand
independentlyfromanyotherfixtureontheDMXchain.Ifseveralfixturesareaddressedsimilarly,theywillwork
synchronically.
PresstheUp/Downbuttonsforsettingthedesiredstartingaddress.Nowyoucanstartoperatingthefixturevia
yourlightingcontroller.
11 of 18

Note:
Afterswitchingon,thedevicewillautomaticallydetectwhetherDMX512dataisreceivedornot.Ifthere
isnodatareceivedattheDMXinput,thedisplaywillflash.
Thissituationcanoccurif:
● theXLRplug(cablewithDMXsignalfromcontroller)isnotconnectedwiththeinputofthedevice.
● thecontrollerisswitchedoffordefective,ifthecableorconnectorisdefectiveorthesignalwires
areswappedintheinputconnector.
Note:
It’snecessarytoinserttheXLRterminationplug(with120Ohm)inthelastlightinginthelinkinorderto
ensurepropertransmissionontheDMXdatalink.
DMXProtocol
St
Ex
Name
Function
DMX
1
1
Pan
Pan Coarse
0-255
2
Pan Fine
Pan Fine
0-255
2
3
Tilt
Tilt Coarse
0-255
4
Tilt Fine
Tilt Fine
0-255
3
5
Movement Speed
Fast to Slow
0-255
6
Movement Function
Normal
Movement with Blackout
No Function
0-15
16-31
32-255
4
7
Shutter
Shutter Closed
Shutter Open
Strobe Effect (Slow to Fast)
Shutter Open
Pulse Effect in Sequences
Shutter Open
Random Strobe Effect (Slow to Fast)
Shutter Open
0-31
32-63
64-95
96-127
128-15
9
160-19
1
192-22
3
224-25
5
5
8
Dimmer
Dimmer (Closed to Open)
0-255
6
9
Color
Indexed:
Open
Color 01 - White Red
Color 02 - Red
Color 03 - Red/Blue
Color 04 - Blue
Color 05 - Blue/Green
Color 06 - Green
0-2
3-5
6-8
9-11
12-14
15-17
18-20
12 of 18

Color 07 - Green/Yellow
Color 08 - Yellow
Color 09 - Yellow/Pink
Color 10 - Pink
Color 11 - Pink/Cyan
Color 12 - Cyan
Color 13 - Cyan/Orange
Color 14 - Orange
Color 15 - Orange/Magenta
Color 16 - Magenta
Color 17 - Magenta/White
Indexed w/ Blackout:
Open
Color 01 - White Red
Color 02 - Red
Color 03 - Red/Blue
Color 04 - Blue
Color 05 - Blue/Green
Color 06 - Green
Color 07 - Green/Yellow
Color 08 - Yellow
Color 09 - Yellow/Pink
Color 10 - Pink
Color 11 - Pink/Cyan
Color 12 - Cyan
Color 13 - Cyan/Orange
Color 14 - Orange
Color 15 - Orange/Magenta
Color 16 - Magenta
Color 17 - Magenta/White
Indexed w/ Bounce:
Color 01 - White Red
Color 03 - Red/Blue
Color 05 - Blue/Green
Color 07 - Green/Yellow
Color 09 - Yellow/Pink
Color 11 - Pink/Cyan
Color 13 - Cyan/Orange
Color 15 - Orange/Magenta
Color 17 - Magenta/White
Forward Wheel Spin (Stop to Fast)
Reverse Wheel Spin (Stop to Fast)
21-23
24-26
27-29
30-32
33-35
36-38
39-41
42-44
45-47
48-50
51-53
54-56
57-59
60-62
63-65
66-68
69-71
72-74
75-77
78-80
81-83
84-86
87-89
90-92
93-95
96-98
99-101
102-10
4
105-10
6
107-11
9
120-13
2
133-14
5
146-15
8
159-17
1
172-18
4
185-19
7
198-21
0
211-22
3
224-23
13 of 18

9
240-25
5
7
10
Gobo
Indexed:
Open
Gobo 1
Gobo 2
Gobo 3
Gobo 4
Gobo 5
Gobo 6
Gobo 7
Indexed w/ Blackout:
Open
Gobo 1
Gobo 2
Gobo 3
Gobo 4
Gobo 5
Gobo 6
Gobo 7
Open
Indexed w/ Shake:
Gobo 1
Gobo 2
Gobo 3
Gobo 4
Gobo 5
Gobo 6
Gobo 7
Forward Wheel Spin (Stop to Fast)
Reverse Spin (Stop to Fast)
0-5
6-11
12-17
18-23
24-29
30-35
36-41
42-47
48-53
54-59
60-65
66-71
72-77
78-83
84-89
90-95
96-97
98-115
116-13
3
134-15
1
152-16
9
170-18
7
188-20
5
206-22
3
224-23
9
240-25
5
8
11
Gobo Rotation
Positioning 0-360°
Forward Animated Rotation
Reverse Animated Rotation
Forward Rotation
Reverse Rotation
0-191
192-20
7
208-22
3
224-23
9
14 of 18

240-25
5
9
12
Prism & Prism Rotation
No Function
Prism Rotation Forward (Slow to Fast)
Prism Rotation Stop
Prism Rotation Reverse (Slow to Fast)
0-3
4-127
128-13
1
132-25
5
10
13
Focus
Focus In to Focus Out
0-255
11
14
Control
Normal
Reset All
Reset Pan & Tilt
Reset Color
Reset Gobos
No Function
Reset Others
Display Off
Display On
No Function
Hibernate
No Function
0-7
8-15
16-23
24-31
32-39
40-47
48-55
56-63
64-71
72-87
88-95
96-255
ControlBoard
The Control Board offers several features. You can simply set the starting address, run the preprogrammed
program,orperformareset.
MainMenu
Browse through the menu by pressing the Mode, Down, Up, and Enter keys. Press Enter in order to select the
desired menu. You can change the selection by pressing the Up and Down buttons. Press Enter in order to
confirm selection, then exit back to the main menu to save changes. The functions provided are described in the
followingsections.
BoldSelectionValues=DefaultSetting
MENU
SUBMENU
SELECTION
FUNCTION
Mode
Addr
XXX
DMXAddressSetting
Slav
Slav
ChooseSlaveMode
Sequ
Alon/Mast
ChooseSequence
Mode
Sund
Alon/Mast
ChooseSoundMode
Lamp
Temp
80~139°C,90°C
Setinternal
temperaturetoshutthe
15 of 18

unitoff.(Activatesafter
5minutes.)
Adju
CHXX=XXX
AdjustValueofEach
Channel
Info
DriT
XXXC
DriverTemperature
Set
Rest
Rest
Reset
Move
RPanON/OFF
RTiltON/OFF
Degr630/540
EncoON/OFF
ModeMod1/Mod2
ReversePan
ReverseTilt
ChoosePanDegree
EncoderWheel
ChoosePan/TiltMode
UI
Mic0~99%,60%
SignClose/Hold/Auto/Music
FanAutoSpeed/HighSpeed
HibeOFF,01M~99M,15M
Back02~60M,02M
FlipON/OFF
UserUse1/Use2
MicSensitivity
SignalMode
FanMode
HibernateTime
BacklightTime
FlipDisplay180°
DMXMode(St/Ex)
Cali
CodeXXX
CHXXXXX
Password(050)
CalibrateChannel
Ver
X1.0.0
ICVersion
load
ON/OFF
ReloadDefault
CLEANINGANDMAINTENANCE
Theoperatorneedstomakesurethatsafetyrelatedandmachinetechnicalinstallationsareinspectedbyan
expertaftereveryfouryearsinthecourseofanacceptancetest.
Theoperatorneedstomakesurethatsafetyrelatingandmachinetechnicalinstallationsareinspectedbya
skilledpersononceayear.
Thefollowingpointsmustbeconsideredduringtheinspection:
1) Allscrewsusedforinstallingthedevicesorpartsneedtobetightlyconnectedandnotcorroded.
2) Theremustnotbeanydeformationsonhousings,fixations,andinstallationspots(ceiling,suspension,
trussing).
3) Mechanicallymovingpartslikeaxlesmustnotshowanytracesofwearing(e.g.materialabradingor
damages)andmustnotrotateunbalanced.
4) Theelectricpowersupplycablesmustnotshowanydamages,materialfatigue(e.g.porouscables),or
sediments.Furtherinstructionsdependingontheinstallationspotandusageneedtobeadheredbyaskilled
installerandanysafetyproblemshavetoberemoved.
Werecommendafrequentcleaningofthedevice.Pleaseuseamoist,lintfreecloth.Neverusealcoholor
solvents!
16 of 18

Theobjectivelenswillrequireweeklycleaningasfog/smokemachinefluidtendstobuildupresidues,reducing
thelightoutputveryquickly.Thecoolingfansshouldbecleanedmonthly.
Theinteriorofthefixtureshouldbecleanedatleastannuallyusingavacuumcleaneroranairjet.
Therearenoserviceablepartsinsidethedevice.Maintenanceandserviceoperationsareonlytobecarriedout
byauthorizeddealers.
ReplacingtheFuse
Onlyreplacethefusebyafuseofsametypeandrating.
Procedure:
Step1: Removethefuseholderontherearpanel.
Step2: Removetheoldfusefromthefuseholder.
Step3: Installthenewfuseinthefuseholder.
Step4: Replacethefuseholderinthehousing.
Shouldyou needanyspareparts,pleaseusegenuineparts.
Ifthepowersupplycableofthisdevicebecomesdamaged,itneedstobereplacedwithaspecialpowersupply
cableavailableatyourdealer.
Shouldyouhavefurtherquestions,pleasecontactyourdealer.
TECHNICALSPECIFICATIONS
PowerSupply:
100240VAC,~50/60Hz
PowerConsumption:
160W
DMXControlChannels:
11/14
DMX512Connection:
3pinXLR
SoundControl:
BuiltinMicrophone
LightSource:
75WWhiteLED
BeamAngle:
Approx.13°to18°
ColorWheel:
8DichroicFilters+Open
RotatingGoboWheel:
7Gobos+Open
17 of 18

OutsideDiameterofGobos
23mm
ImageDiameterofGobos
18mm
MaximumPANMovement:
630°or540°(Selectable)
MaximumTILTmovement:
265°
Dimensions(LxWxH):
343x262x455mm
(13.5”x10.3”x17.9”)
Weight:
10kg(30.9lbs)
MaximumambienttemperatureTa:
45°C113°F
MaximumhousingtemperatureTB(steadystate):
60°C140°F
Min.distancefromflammablesurfaces:
0.5m
Min.distancetolightedobject:
0.3m
Fuse:
T2A,250V
Pleasenote:Allinformationissubjecttochangewithoutpriornotice.05.13.2014
18 of 18
Table of contents
Other OmniSistem Floodlight manuals

OmniSistem
OmniSistem Rocket Laser AL04 Series User manual

OmniSistem
OmniSistem LED Dancer User manual

OmniSistem
OmniSistem Spark 7 Zoom User manual

OmniSistem
OmniSistem LED Shot X4 User manual

OmniSistem
OmniSistem Magic Box Wide Beam BR AL20 Series User manual

OmniSistem
OmniSistem Can Can User manual

OmniSistem
OmniSistem Magic Box Wide Beam User manual